A Novel 12-bit Grayscale Topology PACSmate Revolutionary GrayBoost Technology

Similar documents
Things you may want to know

SUSPENSION CRITERIA FOR IMAGE MONITORS AND VIEWING BOXES.

Image Display and Perception

White Paper. The Advantages of Hybrid Gamma PXL. 1 Introduction Outline of Hybrid Gamma PXL Study Results...

Technical Paper CONSISTENT PRESENTATION OF MEDICAL IMAGES

Barco medical display systems. Product catalog

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Digital Image Management: the Basics

DICOM Conformance. DICOM Detailed Specification for Diagnostic Labs and Radiology Center Connectivity

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage

HP DREAMCOLOR USE CASES

K ODAK D RYV IEW 8900 LASER IMAGER

CXDI-70C WIRELESS SPECIFICATIONS

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

IHE Radiology Technical Framework Supplement. Stereotactic Mammography Image (SMI) Trial Implementation

Chin J Radiol 2004; 29:

SIMPLE. VERSATILE. VERSATILE PRINTING ON FILM OR PAPER. DRYVIEW CHROMA Imaging System

Think Digital. ddr Modulaire A quantum leap in radiography workflow and efficiency.

DELWORKS DR MEDICAL. take the next step

Outline. Digital Radiography. Understanding Digital Modalities: Image Quality and Dose. Image Quality. Dose Control

Quantum Medical Imaging

A Module for Visualisation and Analysis of Digital Images in DICOM File Format

For Your Diagnostic Confidence. Product Brochure

Computer applications, PACS, Instrumentation, Equipment, Technology assessment /ecr2012/C-0655

Open. the Digitized world. Fuji Computed Radiography

Digital radiography (DR) post processing techniques for pediatric radiology

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

Get more from your images with Symphony Image Processing

Ultimate DR flexibility

ddr Compact Series Setting a new benchmark in digital radiography.

DR Retrofit Kit Package Configuration DICOM

The Versatile and Powerful ACLxy. ACLxy

On the Performance of Lossless Wavelet Compression Scheme on Digital Medical Images in JPEG, PNG, BMP and TIFF Formats

CR Retrofit Kit Package Configuration Integrated PACS

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5

Small Animal Radiographic Techniques and Positioning COPYRIGHTED MATERIAL

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

A comparison between medical-grade liquid crystal display (LCD) and ipad color imaging

DICOM Implementations for Digital Radiography

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget

UP-D74XRD. DICOM Digital Imager.

Segmentation of Liver CT Images

DR Retrofit Kit Package Configuration Integrated PACS

DICOM Implementations for Digital Radiography

Get more from your images with Symphony Image Processing

Instant DR in Jordan

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

ABSTRACT 1. PURPOSE 2. METHODS

MEDICAL X-RAY 2D AND 3D IMAGE VIEWER:ROLE FOR THE MEDICAL IMAGE IN DICOM STANDARD

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Increasing the Number of Gray Shades in Medical Display Systems How Much is Enough?

Classic Image Suite. Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP

1 PLANMECA ProSensor. ProSensor Digital Intraoral Systems

Clinical and management aspects of digital imaging and PACS

Acquisition, Processing and Display

Digital Imaging CT & MR

Scalable Data Storage Analysis and Solution for Picture Archiving and Communication Systems (PACS)

2 PLANMECA. PLANMECA ProSensor. ProSensor

MEDICAL DISPLAYS. NEC 90 Series. NEC MD Series

CONSOLE ADVANCE The He art of Your FDR/ FCR System

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

CR Basics and FAQ. Overview. Historical Perspective

DICOM Correction Item

K ODAK D IRECTV IEW CR 950 SYSTEM

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

VISION u UNIVERSAL AUTOPOSITIONING

Grubstr- 6-8 D Vörstetten Tel.: +49(0) Fax: +49(0) Steinhart Medizinsysteme GmbH

efficiency ddrcompact Series

DR _ solutions. We understand that customers don t need just products, they want. solutions

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania

Practical guidelines for color calibration and quality assurance of medical displays

Outline ASRT Changes Impact on current curriculum Potential new courses WECM Changes Last update Resources and needs

Cutting-edge image quality

General Hospital Catalog

DirectView CR 850 System. A fast, premium single-cassette CR system

Digital Film Imager UP-DF550

An Improved Phantom for Quality Control of Laser Scanner Digitizers in Picture Archival and Communications Systems

DICOM Conformance Statement

ISO 4090 INTERNATIONAL STANDARD. Photography Medical radiographic cassettes/screens/films and hard-copy imaging films Dimensions and specifications

Acceptance Testing of a Digital Breast Tomosynthesis Unit

SmartRAD. Advanced Digital Radiography System

REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

Conformance Statement for DICOM Viewer

Simultaneous geometry and color texture acquisition using a single-chip color camera

8/2/2017. Radiologist Responsibilities. Radiologist Responsibilities. Medical Physicist Mammography Equipment Evaluation and Annual Survey

Digital Imaging Considerations Computed Radiography

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

Best and Worst Practices and Software Development Tools DICOM

HIGH-RESOLUTION DIGITAL PHOTOSPOT SYSTEM years, CMT s technology is today proven in more than 4,500 clinical installations PRODUCT SPECIFICATION

C506-E064. Full digital system. Printed in Japan A-NS

ISO INTERNATIONAL STANDARD

VISION V FLOOR MOUNTED ТUBE SYSTEM

of sufficient quality and quantity

GE Healthcare. Senographe 2000D Full-field digital mammography system

VISION u UNIVERSAL AUTOPOSITIONING

DICOM3.0 Conformance Statement

Transcription:

A Novel 12-bit Grayscale Topology PACSmate Revolutionary GrayBoost Technology Author: Kenny Jan Date: August 3, 2009 Presented by PACSmate Technology Inc. Table of Contents 1. Introduction... 2 2. GrayBoost Simultaneous Grayscale Topology... 3 3. Elimination of the posterization in a 12-bit grayscale image... 5 4. Conclusion... 7 5. Reference... 8 All product names are trademarks of their respective owners. Copyright 2009 PACSmate Technology Inc. All rights reserved.

1. Introduction With Picture Archiving and Communication System (PACS) introduced in early 1990 s, the LCD monitor-based imaging has grown dramatically to create a film-less diagnostic environment. To be perfectly used for diagnostic applications, a medical monitor must have the ability to display more than 10-bit grayscale images accurately without any image data loss. There is growing number of images which are more than 10-bit generated by image modalities including X-Ray, CR (Computed Radiography) and MR (Magnetic Resonance) modalities. In figure 1, 12-bit grayscale image for mammography is required to display on a LCD monitor for radiologists to view and to diagnose. In order to keep the precision of acquired radiographic images, the optimal medical image system should retain the 12-bit data flow during the process from image acquired, application software applied, graphic controller processed to monitor displayed. This white paper introduces a novel 12-bit grayscale topology, the GrayBoost topology developed by PACSmate. Figure 1 12-bit mammography image 2

2. GrayBoost Simultaneous Grayscale Topology What is the traditional grayscale topology? Figure 2 illustrates the traditional topology of a display system which is commonly used for displaying more than 8-bit grayscale images. In conventional grayscale topology, it needs a specified medical graphic card and a graphic card dedicated image viewer to display a grayscale image which is more than 8 bits. While being processed by an image viewer, the raw image is converted into a 10-bit or 12-bit packed format specified by a medical graphic controller in a medical graphic card. In addition, the display unit needs to be able to process the specific packed format of grayscale data with a corresponding look-up-table (LUT). In the conventional grayscale topology, DICOM calibration is performed through either the LUT in a medical graphic card or the one in a display unit. Figure 2 Conventional grayscale topology of a display system 3

In comparison, the GrayBoost topology maintains a 12-bit input to 12-bit output grayscale data flow with a standard 24-bit RGB graphic controller. Figure 3 shows the process of the novel GrayBoost grayscale topology. While the image is transferred from a computer to a monitor, the GrayBoost dedicated image viewer firstly packs the 12-bit grayscale image to a standard 24-bit RGB format which could be processed by a commercial 24-bit RGB dual-link DVI graphic board. Secondly, the image is unpacked by the PACSmate display unit to the original 12-bit grayscale data and displayed through the embedded 12-bit to 12-bit LUT. During the process, the input image data is retained in 12-bit grayscale without any image degradation when displayed on a monitor. Theoretically the GrayBoost topology is able to process as high as 24-bit and practically 16-bit grayscale when a commercial grade 24-bit RGB graphic controller is applied. Since there is usually no LUT in a commercial grade graphic card, the DICOM calibration is always performed through the LUT built in the display unit. Figure 3 Novel GrayBoost grayscale topology of a display system 4

3. Elimination of the posterization in a 12-bit grayscale image When displaying a 12-bit grayscale image in an 8-bit display system, the four least significant bits (LSB) of the 12-bit grayscale levels will be rounded into the same gray level which creates the posterization effect on the 12-bit grayscale image. Figure 7 shows the posterization effect of a 8-bit monitor displaying a 12-bit gradient image. Figure 7 Posterization of a 12-bit image on a 8-bit display system By applying the novel GrayBoost 12-bit grayscale topology to a display system, the PACSmate 12-bit monitor renders the same 12-bit image much smoother than a 8-bit one and eliminate the posterization visible by human eyes. Figure 8 shows the elimination of the posterization effect of the 12-bit image. 5

Figure 8 Elimination of the posterization effect of the 12-bit image in the GrayBoost display system 6

4. Conclusion By applying the GrayBoost topology to the display system, 12-bit grayscale images are successfully and precisely reproduced on the PACSmate monitor using a commercial grade 24-bit RGB graphic card instead of a medical graphic card which requires special packed data format. The Grayboost 12-bit display system eliminates the posterization effects in conventional 8-bit display systems and reaches the optimal conformance to the DICOM Grayscale Standard Display Function (GSDF.) 7

5. Reference [1] H.K. Huang, D.Sc. FRCR, Image Acquisition Gateway, in PACS and IMAGING INFORMATICS: BASIC PRINCIPLES AND APPLICATIONS, NY: John Wiley & Sons, 2004, pp. 214-215. [2] DICOM Supplement 28: Grayscale Standard Display Function. Available: http://medical.nema.org/dicom/final/sup28_ft.pdf 8