TARAsens AS2 / AS3. Data Sheet. indicator

Similar documents
TARAline CS4. Data Sheet

TARAtec P9. Data Sheet

Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm. Ambient temperature: C

Measuring and Controlling Unit Multronic OC

OPTISYS CL 1100 Technical Datasheet

Measuring and Controlling Unit Multronic

Drinking water monitoring

OPTISENS CL 1100 Technical Datasheet

Technical Information Memosens CCS50D

ph or ORP Transmitter

OPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

OPTISENS ORP 8590 Technical Datasheet

Rosemount TM 498CL ph-independent Free Chlorine Sensor

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

OPTISENS PH 8100 Technical Datasheet

Magnetic Inductive Flow Sensors VMI Series

dtrans Az 01 µp Indicator/Controller for analytical measurement

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Inductive Conductivity Meter ILM

Process displays For standard signals, temperature, resistance measurement

Conductivity / Temperature Transmitter LMIT 09

Condumax CLS21 and CLS21D

OPTISENS PH ph sensor. Technical Datasheet

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Condumax CLS15 and CLS15D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

SILICon IrrADIAnCe SenSor

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

20 General technical data XI/ON

Screw-in resistance thermometers with plug connector

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

WALLACE & TIERNAN MULTI-FUNCTION-CONTROLLER MFC from version V:2.00

OPTISENS PH 8390 Technical Datasheet

DIGEM f 96 x 48 EK. Applications. Description

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Magnetic Inductive Flow Sensors induq. Series VMI

SMARTPAT PH 1590 Technical Datasheet

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

High-precision process calibrator Model CED7000

JUMPFLEX 857 Series ma ma V. Signal Conditioning/Relay and Solid State Modules

Seapoint Rhodamine Fluorometer

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Condumax W CLS15 and CLS15D

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

LINEAR POTENTIOMETER. LZW Series. Key-Features:

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Instruction Manual. TT1000 Tower Earth Tester. Rev 01

User Manual. PolyGard ADT and ADT Electrochemical Ammonia Transmitter Serial No. AT April 2008

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Inductive conductivity transmitter JUMO CTI-Junior

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Wind Transmitter First Class

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Chlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Mouth Pressure Meter Service Manual

ma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

SMARTPAT ORP 8510 Technical Datasheet

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

DissolvedOxygenMonitor

DMS Insert Module MSR 282

C4E NUMERICAL SENSOR User manual

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

SC-4/M User manual 4-channel measuring amplifier

The transducer component converts the measured signal and displays the actual value.

P5201 Universal Programmable Transmitters with Galvanic Isolation

Technical Information Condumax CLS21D/CLS21

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Please enter the identity code of your device here!

General Specifications

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

WATERFLUX 3000 Quick Start

Conductivity Transmitter

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276

1000TR. Instructions

Metal Finishing. W600 Series Controllers. Summary of Key Benefits

Inductive Standard Displacement Transducers

Digital ORP sensor for the water and wastewater industry

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Condumax CLS15 and CLS15D

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

User Manual. PolyGard ADTD Infrared Carbon Dioxide Transmitter Serial No. SM03_00X. October, 2011

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

B850 Boiler House Energy Monitor

Ultra-Low Power Analog Sensor Module for Sulfur Dioxide

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

ED701 General Industry Pressure Transmitter

Digital inductive conductivity transmitter

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

R S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.

Conex DIA-1, -2, -2Q. Measuring amplifiers and controllers, preassembled systems. One or two parameters (Cl 2, ClO 2, O 3, H 2 O 2, PAA, ph, ORP)

Safe Measurements in High-Voltage Environments CSM GmbH Computer-Systeme-Messtechnik

GRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

Transcription:

TARAsens AS2 / AS3 indicator Application Chlorination agents appropriate chlorine dioxide production methods Measuring system Electronic Information about the measuring range of sensors with 4-20 ma Working temperature AS -CL: AS -CD: Free chlorine Chlorine dioxide drinking water cold, hot until max. 70 C inorganic chlorine compounds: NaOCl (=sodium hypochlorite), Ca(OCl) 2, chlorine gas, electrolytically generated chlorine e. g.: Acid/Chlorite-method Chlorine/Chlorite-method amperometric potentiostatic 3-electrode system Analog version: Digital version: ma-version: - voltage output - not galvanically isolated electronics - analog internal data processing - output signal: analog (analog-out/analog) - electronic is completely galvanically isolated - digital internal data processing - output signal: analog (analog-out/digital) or digital (digital-out/digital) - current output analog - not galvanically isolated electronics - output signal: analog (analog-out/analog) Slope of a sensor can vary production-related or application-related between 65% and 150% of the nominal slope -> Recommendation to determine the suitable measuring range or the suitable sensor: Concentration to be measured x factor 1.5 = measuring range of the sensor Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm Measuring water temperature: AS2 : 0 +50 C AS3..: 0 +70 C (no ice crystals in the measuring water) Ambient temperature: 0 +55 C page 1 / 12

TARAsens AS2 / AS3 Temperature compensation Max. allowed working pressure Cleaning equipment RV1 Flow chamber Automatically, by an integrated temperature sensor Response time t 90 = approx. 10 min. Max. change in temperature: 30 C per hour, sudden temperature changes must be avoided Operation without retaining ring: 0.5 bar Operation with retaining ring: 8 bar Use is recommended for AS -CL (chlorine) Advantages: - significant extension of maintenance intervals - considerably more stable signal over long term TARAflow FLC (separate data sheet available) Flow rate : With RV1: min. 15 l/h, in TARAflow FLC 45-90 l/h, in TARAflow FLC ph-range Run-in time Response time Zero point adjustment Slope calibration AS -CL: ph 5 ph 9, pay attention to the dissociation equilibrium HOCL (see diagram AS-sensors, relative dependence on ph, p. 11) AS -CD: ph 1 ph 12 or the beginning of decomposition of chlorine dioxide at/over ph 12 First start-up approx. 1 h up to 2 days, depending on the water quality T 90: approx. 30 sec. Not necessary Chlorine: At the device, by analytical determination, DPD-1-Method Chlorine dioxide: At the device, by analytical determination, (without chlorine) DPD-1-Method Interferences Absence of the disinfectant AS -CL: AS -CD: Max. 24 h Ozone, chlorine dioxide, chlorite are measured Chlorine, chlorite are measured with less than 2 % of their value analog-out/analog version: 4-pole plug adapter analog-out/digital version: 4-pole plug adapter digital-out/digital version: 5-pole M12, plug-on flange 4-20 ma version: 2-pole terminal or 5-pole M12, plug-on flange page 2 / 12

TARAsens AS2 / AS3 material Size AS2: AS3: PVC-U PEEK diameter: approx. 25 mm Length: analog-out/analog version approx. 175 mm analog-out/digital version approx. 195 mm digital-out/digital version approx. 205 mm 4-20 ma version approx. 220 mm (2-pole-terminal) approx. 190 mm (5-pole-M12) Transport +5 +50 C (Sensor, electrolyte) storage maintenance Sensor: - wet up to one year at +5 +35 C (filled with electrolyte and electrolyte-filled protection-cap) - only for AS2: dry no limit at +5 +40 C (without electrolyte) Electrolyte: in original bottle protected from sunlight at >+5 - <+35 C min. 1 year or until specified EXP-Date Regularly control of the measuring signal, min. once a week The following specifications depend on the water quality: Cleaning of the gold electrodes: without RV1 every 4 12 weeks every 6-12 months Change of the electrolyte: every 3-6 months Option: Factory service/maintenance (return the sensor to the manufacturer) EMV-Prüfung DIN EN 61326-1, 61326-2-3 RoHS konform page 3 / 12

Cleaning equipment RV1-M Option direct installation on the sensor approaching flow to the sensor through RV1 cleaning effect of RV1 is moderate, i. e. weak deposits on the electrodes will be removed, e. g. weak rust films for a correct and proper operation of sensor with cleaning equipment RV1 flow chamber FLC-3 has to be used!! flow rate min. 45 l/h Sensor can be upgraded at any time Advice: Using with AS -CL: => slope is approx. 3 times higher (see diagram AS-Chlorine Sensor with and without RV1, p. 11) Using with AS -CD: => slope is approx. 2 times higher Accessories Component Art. No. Cleaning equipment RV1-M Cleaning equipment RV1 2 bags with each 3 cleaning balls emery S3 12112 Spare Parts Type Hull Electrolyte Emery O-ring All AS2 All AS3 Hull AS2 Art. No. 11103 Hull AS3 Art. No. 11019 EAS1/GEL, 50 ml Art. No. 11905 S3 Art. No. 11904 20 x 1.5 silicone Art. no. 11803 page 4 / 12

Technical Data A) Chlorine 1. AS CL (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. resolution Nominal slope (at ph 7.2) in mv/ppm Voltage AS2H-CL 0.005 2.000 0.005 0.700 0.001 analog -1000-3000 0-2000 mv AS2N-CL 0.03 20.00 0.03 7.00 0.01 1 kω -100-300 AS2Up-CL 0.03 20.00 0.03 7.00 0.01 analog 0 +2000 mv 1 kω +100 +300 AS3H-CL 0.005 2.000 0.005 0.700 0.001 analog -1000-3000 0-2000 mv AS3N-CL 0.03 20.00 0.03 7.00 0.01 1 kω -100-300 ±5 - ±15 VDC 10-30 VDC ±5 - ±15 VDC 4-pole screw connector AS3Up-CL 0.03 20.00 0.03 7.00 0.01 analog 0 +2000 mv 1 kω +100 +300 10-30 VDC 2. AS CL (analog output, digital internal signal processing) analog-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Nominal Slope (at ph 7.2) Power Connectio n in mv/ppm AS2H-CL-An 0.005 2.000 0.005 0.700 0.001-1000 -3000 analog AS2N-CL-An 0.03 20.00 0.03 7.00 0.01 0-2 V -100-300 (max. -2.5 V) AS3H-CL-An 0.005 2.000 0.005 0.700 0.001-1000 -3000 1 k AS3N-CL-An 0.03 20.00 0.03 7.00 0.01-100 -300 AS2H-CL-Ap 0.005 2.000 0.005 0.700 0.001-1000 -3000 analog AS2N-CL-Ap 0.03 20.00 0.03 7.00 0.01 0 +2 V -100-300 (max. +2.5 V) AS3H-CL-Ap 0.005 2.000 0.005 0.700 0.001-1000 -3000 1 k AS3N-CL-Ap 0.03 20.00 0.03 7.00 0.01-100 -300 9-30 VDC approx. 56-20 ma 4-pole screw connector page 5 / 12

3. AS CL (digital output, analog internal signal processing) digital-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Power AS2H-CL-M0c 0.005 2.000 0.005 0.700 0.001 AS2N-CL-M0c 0.03 20.00 0.03 7.00 0.01 AS3H-CL-M0c 0.005 2.000 0.005 0.700 0.001 Modbus RTU There are no terminating resistors in the sensor. 9-30 VDC approx. 56-20 ma 5-pole M12 plug-on flange AS3N-CL-M0c 0.03 20.00 0.03 7.00 0.01 4. AS CL 4-20 ma (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. 4.1 Electrical connection: 2 pole terminal clamp resolution Nominal slope (at ph 7.2) in ma/ppm Voltage AS2MA1-CL 0.003 1.000 0.003 0.400 0.001 16.0 48.0 AS2MA2-CL 0.003 2.000 0.003 0.700 0.001 8.0 24.0 AS2MA5-CL 0.03 5.00 0.03 1.70 0.01 3.2 9.6 AS2MA10-CL 0.03 10.00 0.03 4.00 0.01 1.6 4.8 AS2MA20-CL AS3MA1-CL 0.03 20.00 0.003 1.000 0.03 7.00 0.003 0.400 0.01 0.001 4 20 ma uncalibrated 0.8 16.0 2.4 48.0 AS3MA2-CL 0.003 2.000 0.003 0.700 0.001 8.0 24.0 AS3MA5-CL 0.03 5.00 0.03 1.70 0.01 3.2 9.6 12 30 VDC R L 50Ω R L 900Ω 2-pole terminal (2 x 1 mm²) Recommend ed: Round cable 4 mm 2 x 0.34 mm² AS3MA10-CL 0.03 10.00 0.03 4.00 0.01 1.6 4.8 AS3MA20-CL 0.03 20.00 0.03 7.00 0.01 0.8 2.4 page 6 / 12

4.2 Electrical connection: 5 pole M12 plug-on flange resolution Nominal slope (at ph 7.2) in ma/ppm Voltage Connectio n AS2MA1-CL-M12 0.003 1.000 0.003 0.400 0.001 16.0 48.0 AS2MA2-CL-M12 0.003 2.000 0.003 0.700 0.001 8.0 24.0 AS2MA5-CL-M12 0.03 5.00 0.03 1.70 0.01 3.2 9.6 AS2MA10-CL-M12 0.03 10.00 0.03 4.00 0.01 1.6 4.8 AS2MA20-CL-M12 AS3MA1-CL-M12 0.03 20.00 0.003 1.000 0.03 7.00 0.003 0.400 0.01 0.001 4 20 ma uncalibrated 0.8 16.0 2.4 48.0 AS3MA2-CL-M12 0.003 2.000 0.003 0.700 0.001 8.0 24.0 12 30 VDC R L 50Ω R L 900Ω 5-pole M12 plugon flange Function of wires: PIN2: +U PIN3: -U AS3MA5-CL-M12 0.03 5.00 0.03 1.70 0.01 3.2 9.6 AS3MA10-CL-M12 0.03 10.00 0.03 4.00 0.01 1.6 4.8 AS3MA20-CL-M12 0.03 20.00 0.03 7.00 0.01 0.8 2.4 page 7 / 12

B) Chlorine Dioxide 1. AS CD (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. resolution Nominal slope in mv/ppm Voltage Connectio n AS2H-CD 0.005 2.000 0.005 1.000 0.001 0-2000 mv -1000-2000 1 kω AS2N-CD 0.03 20.00 0.03 10.00 0.01-100 -200 AS2Up-CD 0.03 20.00 0.03 10.00 0.01 0 +2000 mv 1 kω +100 +200 AS3H-CD 0.005 2.000 0.005 1.000 0.001 0-2000 mv -1000-2000 1 kω AS3N-CD 0.03 20.00 0.03 10.00 0.01-100 -200 ±5 - ±15 VDC 10-30 VDC ±5 - ±15 VDC 4-pole screw connector AS3Up-CD 0.03 20.00 0.03 10.00 0.01 0 +2000 mv 1 kω +100 +200 10-30 VDC 2. AS CD (analog output, digital internal signal processing) analog-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Nominal Slope in mv/ppm Power AS2H-CD-An 0.005 2.000 0.005 1.000 0.001-1000 -2000 analog AS2N-CD-An 0.03 20.00 0.03 10.00 0.01 0-2 V -100-200 (max. -2.5 V) AS3H-CD-An 0.005 2.000 0.005 1.000 0.001-1000 -2000 1 k AS3N-CD-An 0.03 20.00 0.03 10.00 0.01-100 -200 AS2H-CD-Ap 0.005 2.000 0.005 1.000 0.001 +1000 +200 analog AS2N-CD-Ap 0.03 20.00 0.03 10.00 0.01 0 +2 V +100 +200 (max. +2.5 V) AS3H-CD-Ap 0.005 2.000 0.005 1.000 0.001 +1000 +2000 1 k AS3N-CD-Ap 0.03 20.00 0.03 10.00 0.01 +100 +200 9-30 VDC approx. 56-20 ma 4-pole screw connector page 8 / 12

3. AS CD (digital output, analog internal signal processing) digital-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Power AS2H-CD-M0c 0.005 2.000 0.005 1.000 0.001 AS2N-CD-M0c 0.03 20.00 0.03 10.00 0.01 AS3H-CD-M0c 0.005 2.000 0.005 1.000 0.001 Modbus RTU There are no terminating resistors in the sensor. 9-30 VDC approx. 56-20 ma 5-pole M12 plug-on flange AS3N-CD-M0c 0.03 20.00 0.03 10.00 0.01 4. AS CD 4-20 ma (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. 4.1 Electrical connection: 2 pole terminal clamp resolution Nominal slope in ma/ppm Voltage AS2MA1-CD 0.003 1.000 0.003 0.500 0.001 16.0 32.0 AS2MA2-CD 0.003 2.000 0.003 1.000 0.001 8.0 16.0 AS2MA5-CD AS3MA1-CD 0.03 5.00 0.003 1.000 0.03 2.50 0.003 0.500 0.01 0.001 4 20 ma unkalibriert 3.2 16.0 6.4 32.0 AS3MA2-CD 0.003 2.000 0.003 1.000 0.001 8.0 16.0 AS3MA5-CD 0.03 5.00 0.03 2.50 0.01 3.2 6.4 12 30 VDC R L 50Ω R L 900Ω 2-pole terminal (2 x 1 mm²) Recommended : Round cable 4 mm 2 x 0.34 mm² page 9 / 12

4.2 Electrical connection: 5 pole M12 plug-on flange resolution Nominal slope in ma/ppm Voltage Connectio n AS2MA1-CD-M12 0.003 1.000 0.003 0.500 0.001 16.0 32.0 AS2MA2-CD-M12 0.003 2.000 0.003 1.000 0.001 8.0 16.0 AS2MA5-CD-M12 AS3MA1-CD-M12 0.03 5.00 0.003 1.000 0.03 2.50 0.003 0.500 0.01 0.001 4 20 ma unkalibriert 3.2 16.0 6.4 32.0 AS3MA2-CD-M12 0.003 2.000 0.003 1.000 0.001 8.0 16.0 12 30 VDC R L 50Ω R L 900Ω 5-pole M12 plug-on flange Function of wires: PIN2: +U PIN3: -U AS3MA5-CD-M12 0.03 5.00 0.03 2.50 0.01 3.2 6.4 Reiss GmbH Elektrochemische Messtechnik Eisleber Str. 5 D 68469 Weinheim Germany page 10 / 12

AS-Sensoren, relative ph-abhängigkeit AS-sensors, relative dependence on ph 250 Cl 2 200 Steilheit / slope [%] (ph7 = 100 %) 150 100 50 0 4 5 6 7 8 9 10 K:\Technik\Serienprodukt e_we\as\as2\1_05_01_ph_abhängigkeit ph-wert / ph-value 11.03.2004 page 11 / 12

Sensor AS2 / AS3 Abhängigkeit vom Durchfluß, Dependence on the flow rate 200 Durchflussarmatur, Flow Chamber: PEF1/E or ph-wert: 1_02_01_Durchfluss 25.08.2005 190 180 170 Sensor signal mv 160 150 140 130 120 110 100 0 20 40 60 80 100 120 Durchflußmenge, Flow rate (Liter/hours) page 12 / 12