PERFORMANCE ANALYSIS OF WDM PONS BASED ON FP-LD USING RZ-OOK AND NRZ-OOK

Similar documents
Wavelength Division Multiplexing Passive Optical Network (WDM-PON) technologies for future access networks

Mahendra Kumar1 Navneet Agrawal2

ANALYSIS OF BIDIRECTIONAL LONG REACH WDM PON

Colorless Amplified WDM-PON Employing Broadband Light Source Seeded Optical Sources and Channel-by-Channel Dispersion Compensators for >100 km Reach

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

A HIGH SPEED WDM PON FOR DOWNSTREAM DPSK ASK SIGNALS AND UPSTREAM OOK SIGNAL WITH BROADCAST CAPABILTY

A WDM passive optical network enabling multicasting with color-free ONUs

Colorless Components for WDM-based Optical Access Networks

Utilizing Self-Seeding RSOA with Faraday Rotator Mirror for Colorless Access Network

Downstream Transmission in a WDM-PON System Using a Multiwavelength SOA-Based Fiber Ring Laser Source

PERFORMANCE EVALUATION OF GB/S BIDIRECTIONAL DWDM PASSIVE OPTICAL NETWORK BASED ON CYCLIC AWG

WDM-PON Delivering 5-Gbps Downstream/2.5-Gbps Upstream Data

Optical Fiber Technology. Using 10 Gb/s remodulation DPSK signal in self-restored colorless WDM-PON system

Optical Fiber Technology

Performance Comparison of Pre-, Post-, and Symmetrical Dispersion Compensation for 96 x 40 Gb/s DWDM System using DCF

Novel Design of Long Reach WDM-PON by using Directly Modulated RSOA

80 GBPS DOWNSTREAM TRANSMISSION USING DQPSK AND 40 GBPS UPSTREAM TRANSMISSION USING IRZ/OOK MODULATION IN BIDIRECTIONAL WDM-PON

Design and Performance Evaluation of 20 GB/s Bidirectional DWDM Passive Optical Network Based on Array Waveguide Gratings

Free Space Optical Communication System under all weather conditions using DWDM

DESIGN OF BIDIRECTIONAL PASSIVE OPTICAL NETWORK USING DIFFERENT MODULATIONS

International Journal of Emerging Technology and Advanced Engineering Website: (ISSN , Volume 2, Issue 6, June 2012)

Radio over Fiber Technology for Investigation of Hybrid Passive Optical Networks

Comparative Analysis Of Different Dispersion Compensation Techniques On 40 Gbps Dwdm System

Visible to infrared high-speed WDM transmission over PCF

A Long Haul Carrier Generated Ultra Dense Passive Optical Network Incorporating Low Cost VCSEL

Microwave and Optical Technology Letters. Minhui Yan, Qing-Yang Xu 1, Chih-Hung Chen, Wei-Ping Huang, and Xiaobin Hong

Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration

Implementation and analysis of 2 Tbps MDRZ DWDM system at ultra narrow channel spacing

SIMULATIVE INVESTIGATION OF SINGLE-TONE ROF SYSTEM USING VARIOUS DUOBINARY MODULATION FORMATS

22-Channel Capacity of 2.5Gbit/s DWDM-PON ONU Transmitter by Direct-Modularly Side-Mode Injection Locked FPLD

Implementing of High Capacity Tbps DWDM System Optical Network

RADIO-OVER-FIBER TRANSPORT SYSTEMS BASED ON DFB LD WITH MAIN AND 1 SIDE MODES INJECTION-LOCKED TECHNIQUE

To generate a broadband light source by using mutually injection-locked Fabry-Perot laser diodes

Mitigation of Mode Partition Noise in Quantum-dash Fabry-Perot Mode-locked Lasers using Manchester Encoding

Enhanced 10 Gb/s operations of directly modulated reflective semiconductor optical amplifiers without electronic equalization

Provision of IR-UWB wireless and baseband wired services over a WDM-PON

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG

Implementation of Extended Reach Hybrid TDM-PON for 1:128 split ratio

Performance of A Multicast DWDM Network Applied to the Yemen Universities Network using Quality Check Algorithm

1.25 Gb/s Broadcast Signal Transmission in WDM-PON Based on Mutually Injected Fabry-Perot Laser Diodes

JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 28, NO. 16, AUGUST 15, /$ IEEE

Part III Optical Communications

Interoperability of CWDM-routed reflective PONs. This chapter presents a complete multi-pon access network infrastructure by means of

Performance Evaluation of Post and Symmetrical DCF Technique with EDFA in 32x10, 32x20 and 32x40 Gbps WDM Systems

ANALYSIS OF FWM POWER AND EFFICIENCY IN DWDM SYSTEMS BASED ON CHROMATIC DISPERSION AND CHANNEL SPACING

Bidirectional WDM Access Architecture Employing Cascaded AWGs and RSOAs.

20-Gb/s Transmission Over 25-km in Wavelength Division Multiplexing Passive Optical Network with Centralized Light Source

1.6 Tbps High Speed Long Reach DWDM System by incorporating Modified Duobinary Modulation Scheme

Performance Analysis of Chromatic Dispersion Compensation of a Chirped Fiber Grating on a Differential Phase-shift-keyed Transmission

Investigation of Performance Analysis of EDFA Amplifier. Using Different Pump Wavelengths and Powers

TRANSMISSION OF NG-PON FOR LONG HAUL NETWORKS USING HYBRID AMPLIFIER

Simulative Analysis of 40 Gbps DWDM System Using Combination of Hybrid Modulators and Optical Filters for Suppression of Four-Wave Mixing

Performance Analysis of OFDM FSO System using ODSB, OSSB and OVSB modulation scheme by employing Spatial Diversity

Evolution from TDM-PONs to Next-Generation PONs

Elements of Optical Networking

RSOA BASED 10G WDM FOR LONG REACH PON USING MANCHESTER CODING FOR REMODULATION.

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. FINAL EXAMINATION, April 2017 DURATION: 2.5 hours

Performance Evaluation of 32 Channel DWDM System Using Dispersion Compensation Unit at Different Bit Rates

All-Optical Clock Division Using Period-one Oscillation of Optically Injected Semiconductor Laser

Life Science Journal 2013;10(4)

MULTICHANNEL COST EFFECTIVE FULL DUPLEX RADIO OVER FIBER COMMUNICATION SYSTEM USING FIBER BRAGG GRATING FILTER

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA

1150 JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 34, NO. 4, FEBRUARY 15, Xiang Chen, Student Member, IEEE, and Jianping Yao, Fellow, IEEE, Fellow, OSA

Risk Reduction in Operations, Maintenance and Application for Customer Access Network

Performance evaluation for optical backhaul and wireless front-end in hybrid optical-wireless access network

Coexistence of 10G-PON and GPON Reach Extension to 50-Km with Entirely Passive Fiber Plant

Design and Simulation of Fiber to the Home (FTTH) Network

Performance Evaluation of Gbps (1.28 Tbps) FSO Link using RZ and NRZ Line Codes

70km external cavity DWDM sources based on O-band Self Seeded RSOAs for transmissions at 2.5Gbit/s

Long Haul Communication using Hybrid Optical Amplifiers.

Performance Evaluation of Hybrid (Raman+EDFA) Optical Amplifiers in Dense Wavelength Division Multiplexed Optical Transmission System

SEMICONDUCTOR lasers and amplifiers are important

Effect of Signal Direct Detection on Sub-Carrier Multiplexed Radio over Fiber System

Performance Analysis of Optical Time Division Multiplexing Using RZ Pulse Generator

Design and Performance Analysis of Optical Transmission System

BER Evaluation of FSO Link with Hybrid Amplifier for Different Duty Cycles of RZ Pulse in Different Conditions of Rainfall

Simulation of RoF Using Wavelength Selective OADM

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Optical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p.

Wavelength-division-multiplexed passive optical network (WDM-PON) technologies for broadband access: a review [Invited]

Design of Ultra High Capacity DWDM System with Different Modulation Formats

Optical Communications and Networks - Review and Evolution (OPTI 500) Massoud Karbassian

Optical Communications and Networks - Review and Evolution (OPTI 500) Massoud Karbassian

Enhanced Reflection Tolerance of Upstream Signal in a RSOA-based WDM PON by using Manchester Coding

Simultaneous Four-Wave Mixing and Cross-Gain Modulation for Implementing All Optical Full Adder without Assist Light

I.INTRODUCTION. Neeru, IJECS Volume 6 Issue 7 July 2017 Page No Page 21884

Dr. Monir Hossen ECE, KUET

Analysis of Transmitting 40Gb/s CWDM Based on Extinction Value and Fiber Length Using EDFA

Chirped Bragg Grating Dispersion Compensation in Dense Wavelength Division Multiplexing Optical Long-Haul Networks

Performance analysis of terrestrial WDM-FSO Link under Different Weather Channel

Wavelength-Enhanced Passive Optical Networks with Extended Reach

1.25-Gb/s Millimeter-Wave Band Wired/Wireless Radio-over-Fiber System based on RSOA using an Injection-Locked FP-Laser

Compensation of Dispersion in 10 Gbps WDM System by Using Fiber Bragg Grating

Teknologi Malaysia (UTM), 81310, Johor Bahru, Malaysia

Design & investigation of 32 Channel WDM-FSO Link under Different Weather condition at 5 & 10 Gb/s

Performance Investigation of RAMAN-EDFA HOA for DWDM System (Received 17 September, 2016 Accepted 02 October, 2016)

Comparison of Advance Data Modulation Formats in 4 10Gbps WDM Optical Communication System using YDFA, EDFA and Raman Amplifier

THE WAVELENGTH-division multiplexed passive optical

Design of Multiband RoF-PoN for Down Stream and Wavelength Reuse to Upstream

Transcription:

PERFORMANCE ANALYSIS OF WDM PONS BASED ON FP-LD USING RZ-OOK AND NRZ-OOK Mukesh Kumar 1, Dr. Ajay Pal Singh 2 Department of Electronics and Communication Engineering, Sant Longowal Institute of Engineering and Technology (Deemed University), Punjab (India) ABSTRACT Transmission medium used for communication of signal from one point to another point are copper wire, coaxial cables, wave-guides and radio links. All these mediums have their own advantages and disadvantages. Wavelength Division Multiplexing Passive Optical Networks (WDM PONs) is optical based communication which introduces a good data transmission rate and large bandwidth. WDM PON is bidirectional PON system based on a Fabry-Perot laser diode (FP-LD) with two cascaded array waveguide gratings (AWGs). The downstream data rate equals to 10 Gbps and the upstream data rate equals to 2.5 Gbps. In downstream, CW laser with frequency (193.1 THz) is modulated by AM modulator using 10 Gbps non-return to zero (NRZ) downstream data to generate the desired downstream signal. The generated signal is sent over the bidirectional Optical Fiber. A circulator is used in the CO to separate the downstream and upstream traffic. The modulated signal is sent to ONU. At the ONU, using optical splitter/coupler, portion of the modulated signal is fed to a balanced receiver. For upstream other portion of the downstream modulated signal from the splitter/coupler is re-modulated using 2.5 Gbps NRZ upstream data by FP-LD in the ONU. The re-modulated OOK signal repasses through the bidirectional Optical Fiber. Performance of WDM PONs system using different modulation techniques such as NRZ-OOK, RZ-OOK has been analyzed and in the last comparison between different modulation techniques has been done. The performance of the system is analyzed by calculating bit error rate and quality factor. Keywords: FP-LD, RZ-OOK, NRZ-OOK, AWGs, Colorless Transmission I. INTRODUCTION WDM PONs is optical based communication which introduces a good data transmission rate and large bandwidth. WDM PON is bidirectional PON system based on a Fabry-Perot laser diode (FP-LD). FP-LD is considered as low cost optical source, it is less costly than other sources like distributed feedback (DFB) laser, vertical cavity surface emitting lasers (VCSELs) and reflective semiconductor optical amplifier (RSOA).AM Modulator is used at central office and AWGs are used at CO and ONU. Our proposed systems are low cost system and the injection locked FP-LD is used as low cost colorless transmitters for high speed optical access exploiting WDM technology. WDM PON architecture is categorized into three main parts which are Central Office (CO), bidirectional fiber channel and Optical Network Unit (ONU) as shown in Fig. 1. Central Office is a 179 P a g e

place of convergence where data arrives from one or more directions and is forwarded out in one or more directions. Optical network unit (ONU) is the user side equipment. Fig.1 WDM-PON architecture II DESIGN OF WDM PONS BASED ON FP-LD USING RZ-OOK The first proposed PON architecture includes two cascaded AWGs at both CO and Remote Node RN with RZ- OOK as shown in Fig.2. In downstream, CW laser with 193.1 THz frequency is modulated by AM modulator using 10 Gbps NRZ downstream data to generate the desired downstream signal. The generated signal is sent to the first AWG at CO which multiplexed it and is sent over the bidirectional Optical Fiber. It passes through the second AWG at RN which multiplexed the input signal again. The multiplexed signal is sent to ONU. At the ONU, using optical splitter/coupler, portion of the multiplexed signal is fed to a balanced receiver. For upstream, other portion of the downstream multiplexed signal from the splitter/coupler is re-modulated using 2.5 Gbps NRZ upstream data by FP-LD in the ONU. The re-modulated signal repasses through the AWG which demultiplexed the upstream signal then it is sent over Bidirectional Optical Fiber. The upstream demultiplexed signal passes through the first AWG then it is received by CO. Circulator is used to avoid influencing the downstream signal, the upstream signal is sent to a PD is used to receive the upstream signal in the CO. Fig.2 Block diagram of first bidirectional PON system model with RZ-OOK 180 P a g e

2.1 Central Office Fig.3 CO part in WDM PON with RZ-OOK Transmitter includes PRBS generator, RZ generator, CW laser and AM modulator. Receiver contains PD, LPBF, 3R regenerator and BER analyzer. 2.2 Bidirectional channel Part Fig.4 Bidirectional channel in WDM-PON with two cascaded AWGs The channel includes bidirectional optical fiber as shown in Fig.4. A bidirectional single mode fiber of 10 km is used to forward the signal and to backward it with an optical delays of 1 unit in order to separate the upstream and downstream signals. The fiber cable has an attenuation loss of 0.2dB/km and length of 10 km, this means there is a 0.2 db/km 10 km which equals to 2 db power losses. 181 P a g e

2.3 ONU Part The transceiver at ONU includes two parts, first part is used to receive the signal from CO and second part is used to send signal to CO as shown in Fig.4. ONU includes many components for receiving downstream signal and for transmitting upstream signal. Received signal components include Splitter, optical attenuator, PIN PD, LPBF, 3R regenerator and BER analyzer. Transmitted signal components include FP-LD, NRZ generator and PRBS generator. Fig.5 ONU part in WDM PON network III DESIGN OF WDM PONS BASED ON FP-LD USING NRZ-OOK The second proposed PON architecture includes two cascaded AWGs at both CO and RN with NRZ-OOK.as shown in Fig.6. In downstream, CW laser with 193.1 THz frequency is modulated by AM modulator using 10 Gbps NRZ downstream data to generate the desired downstream signal. The generated signal is sent to the first AWG at CO which multiplexed it and is sent over the bidirectional Optical Fiber. 182 P a g e

Fig.6 Block diagram of first bidirectional PON system model with NRZ OOK Fig.7 CO part in WDM PON with NRZ OOK Modulation Bidirectional channel and ONU part used here is same as Fig.4 and Fig.5 and also working principle is same. IV SIMULATION AND RESULTS OptiSystem software is used for simulation. Optisystem software is an innovative optical communication system simulation package that designs, tests, and optimizes virtually any type of optical link in the physical layer of a broad spectrum of optical network. 4.1 Comparison on the results of the two proposed models with CW laser power variation Effect of variation in CW laser power on the BER at CO and end user (ONU) for the two systems when the input power is fixed and it is equals to 0 dbm. All systems include FP-LD at end user for sending upstream 183 P a g e

signal. First model WDM PON System based on FP-LD with RZ-OOK have minimum BER of downstream signal equals to 2.35371e-011while second model WDM PON System based on FP-LD with NRZ-OOK have minimum BER for downstream signal 2.85646e-017. Also for first model minimum upstream BER is 3.3747e- 009 and for second model minimum BER with upstream is 1.7609e-013. Table 1 Comparison between two proposed PON models S.No. CW Laser WDM PON with RZ-OOK WDM PON with NRZ-OOK Power Downstream BER Upstream BER Downstream Upstream BER (dbm) BER 1. 0 2.35371e-011 3.3747e-009 2.85646e-017 1.7609e-013 2. 1 3.03521e-015 1.4251e-012 1.25056e-021 8.66847e-017 3. 2 1.17618e-016 6.24379e-014 5.51024e-024 7.07996e-018 4. 3 1.51232e-019 1.01232e-018 5.03655e-029 2.15411e-023 5. 4 8.9804e-023 1.1805e-022 2.62801e-033 2.11451e-025 6. 5 7.78229e-024 2.79583e-026 2.88596e-030 1.057e-029 7. 6 8.35113e-025 2.85363e-027 8.7651e-036 1.71036e-030 8. 7 4.65699e-030 4.80838e-029 4.74592e-041 1.51062e-031 So second proposed model WDM PON System based on FP-LD with NRZ-OOK is better than first model WDM PON System based on FP-LD with RZ-OOK because the downstream and upstream BER values are good in second proposed system. Fig. 6 shows variation of Quality factor with different value of laser power. There is rise in the value of quality factor when laser power increases but NRZ gives better result. Fig.8 Graph shows variation of Quality Factor at ONU with different value of Laser Power for RZ-OOK and NRZ-OOK 184 P a g e

4.2 Comparison on the results of the two proposed models with fiber length variation Effect of variation in fiber length on the BER at end user (ONU) for the two systems when parameter of FP-LD is fixed.. First model WDM PON System based on FP-LD with RZ-OOK have minimum BER of downstream signal equals to 1.2537e-013 while second model WDM PON System based on FP-LD with NRZ-OOK have minimum BER for downstream signal equal to 1.68183e-026. Table 2 shows required comparison. Table 2 Comparison between two proposed PON models S.No. Fiber Length WDM PON with RZ-OOK WDM PON with NRZ-OOK (km) Downstream BER Downstream BER 1. 10 1.2537e-013 1.68183e-026 2. 12 3.9672e-014 1.37136e-024 3. 13 3.0561e-014 7.06577e-021 4. 14 3.52432e-011 6.22754e-017 5. 16 3.46068e-009 1.9318e-016 6. 18 1.54475e-008 7.14164e-014 7. 19 1.57333e-007 3.15471e-014 8. 20 7.74542e-006 1.92478e-012 So second proposed model WDM PON System based on FP-LD with NRZ-OOK is better than first model WDM PON System based on FP-LD with RZ-OOK because the downstream BER values are good in second proposed system. V CONCLUSION Optical fiber based communication is modern medium of transmission which provide high bit rate that fulfill the demand of high speed internet. Performance of WDM PONs system using different modulation techniques such as NRZ-OOK, RZ-OOK has been analyzed by Optisystem software and in the last comparison between different modulation techniques has been done. First model WDM PON System based on FP-LD with RZ- OOK have minimum BER of downstream signal equals to 2.35371e-011while second model WDM PON System based on FP-LD with NRZ-OOK have minimum BER for downstream signal 2.85646e-017. Also for first model minimum upstream BER is 3.3747e-009 and for second model minimum BER with upstream is 1.7609e-013.So second proposed model WDM PON System based on FP-LD with NRZ-OOK is better than first model WDM PON System based on FP-LD with RZ-OOK because the downstream and upstream BER values are good in second proposed system than first model.also by using FP-LD cost of Optical Network Unit (ONU) reduces. 185 P a g e

REFERENCES [1] F. El-Nahal and A. Husein, Bidirectional WDM-PON architecture using a reflective filter and cyclic AWG, Optik Int. J. Light Electron Opt., 122(19), 2011, 1776-1778. [2] H. Bakarman, S. Shaari, and M. Ismail, Simulation of 1.25 Gb/s Downstream Transmission Performance of GPON-FTTx, International Conference On Photonics, 2010, 1-5. [3] A. Banerjee, Y. Park, F. Clark, H. Song, S. Yang, G. Kramer, K. Kim, and B. Mukerjee, Wavelengthdivision-multiplexed passive optical network (WDM-PON) Technologies for broadband access: a review, Journal of Optical Networking, 4(11), 2005, 737 756. [4] C. Arellano, C. Bock, and J. Prat, RSOA-based Optical Network Units for WDM-PON, Optical Fiber Communication Conference, 2005, 1-3. [5] J. Yu, B. Kim, N. Kim, Wavelength Re-use Scheme with Reflective SOA for WDM-PON Link, 10th International Conference, 2008, 1704 1710. [6] L.Y. Chan, C. K. Chan, D. T. K Tong, E Tong and L.K. Chen, Upstream traffic transmitter using injectionlocked Fabry-Perot laser diode as modulator for WDM access networks, electronics letters, 38(1), 2002, 43-45. [7] Nguyen QT, Bramerie L, Girault G, Vaudel O, Besnard P, Simon JC, Shen A, Duan GH, Kazmierski C., 16x2.5 Gbit/s Downstream Transmission in Colorless WDM-PON based on Injection-Locked Fabry-Perot Laser Diode using a single Quantum Dash mode-locked Fabry Perot laser as multi-wavelength seeding source, Optical Fiber Communication Conference, 2009. 186 P a g e