PA0688 Microphone Pre-Amplifier Module

Similar documents
TOA 500 SERIES MIXER POWER AMPLIFIER

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

PLE 2CS Plena Two-zone Call Station

Mixing Amplifier MA 247MR

PERMA Series Revision 2 Amplifiers

3.Avoid spilling liquids or allowing materials to enter the cabinet

bhi bhi DSP Noise Cancelling Products DSP Noise Cancelling Products NEDSP1061-PCB bhi ltd PO Box 318 Burgess Hill West Sussex RH15 9NR

Model 7000 Low Noise Differential Preamplifier

THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN

User Manual. MA 21 Two zone mixing amplifier

3050 Stereo Power Amplifier

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C

MPU 2120 MPU Monoblock unit 60W to 480W Same features as the MPU 2120 model except for the following difference: Configurations: 4x60W, 2x120W

PS 260T DUAL CHANNEL AUDIO INTERFACE USER MANUAL

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Model 901 HEADPHONE AMPLIFIER OWNERS MANUAL. PO Box 204 Boulder, CO tel: fax:

Boulder 810 Preamplifier

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

GCX. Guitar Audio Switcher OWNER S MANUAL

BS 17 SINGLE CHANNEL BELTPACK. User Manual. January 2017 V1.0

Model 1791 VHF Radio User's Manual

KXB800 BASS AMPLIFIER

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

bhi bhi Sound Engineering Solutions from bhi Sound Engineering Solutions NEDSP1061-PCB bhi ltd 22 Woolven Close Burgess Hill West Sussex RH15 9RR

Integrated mixer amplifier PA-60/120/240

P.I.P.-RPA P.I.P.-RPAT

PA240 ORDERCODE D6113

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

TOA NEW 900 SERIES POWER AMPLIFIER

PS 19 AM SINGLE CHANNEL BELTPACK IN METAL CASE WITH PGM (AUX) INPUT

ACCESSORY CONNECTOR KIT

ELECTRONIC COMPONENTS LP4 32 USER MANUAL

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

MA80FT Mini Amplifier

HX-3. Headphone Distribution Amplifier User Guide and Technical Information

STORE BACKGROUND AUDIO SYSTEM. commercial media systems. MOOD: Amplifier Pre-amplifier MOOD: Ceiling Speakers* For use by trained installers only

Boulder W Mono Power Amplifier

T-link8. SPLITTER/MIXER T-link8. T-link8

TOA 900 SERIES POWER AMPLIFIER P-924A

FISCHER AMPS MANUAL. In Ear Amp 2

F O R T H E L O V E O F M U S I C LP100 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A. General Description. TOA Corporation. Operation Instruction Manual

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

VENUE Full Isolation D.I.

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content

PB 700 PB 1000 PB 1100 PB 1500 PB 2600 PB 1200 PB 1700 PB 2200 PB 2700 USER'S MANUAL.

User Manual. MA 240 Mixing amplifier

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

IMPORTANT SAFETY INSTRUCTIONS

Model WM1000/WM2000. Wall Mount Intercom Stations. User Instructions

KSM9. User Guide Guide de l'utilisateur Bedienungsanleitung Guía del Usuario Guida dell'utilizzatore. 2006, Shure Incorporated 27B3192 (Rev.

Operation Instruction Manual - SVMP2-8 Media Player

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

Z4MK3/Z8MK3 : Zone Mixers

1160 Stereo Power Amplifier

Q-Tech Commercial Series. 86 Derby St. Pascoe Vale VIC 3055 ( : *

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

Synthesized Base Station Transmitter

Cross-Connect Interface

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual

HARP EFFECTS BY MARKO BALLAND [1]

Ai1 OWNER S MANUAL. Getting Started:

Chameleon Labs Model 7602

F O R T H E L O V E O F M U S I C SERIES 218 DPS200 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER

LT-800 Stationary FM Transmitter

ILD252 INDUCTION LOOP DRIVER

The following examples explore some of the possible uses of these preamps.

Ambient Level Controller

Callouts 1. INPUT 2. THRU 3. GROUND LIFT 4. BALANCED OUTPUT

Program Input Equipment. Promotional Information

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

MANUAL MA200

ADSworldwide (AUDIO DESIGN SERVICES LIMITED)

AUTOMATIC MIXER AX-1OOOA

PM7400MKII. Instruction manual

ELECTRONIC COMPONENTS LP444 USER MANUAL

NV-P2100. Audio Amplifier Owner s Manual

Registration 3. Owners Record Setup 4. Unit Connections 6. Front Panel Controls 8. Remote Control 9. Unit Care Technology 10. Designer s Note 12.

Bosch Communications Systems Get your message across, effectively.

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

i3speakers LX503 MK2 User Manual

ANI-F-KW1. Multi-Format ANI Encoder For Kenwood Radios. Manual Revision: Covers Software Revisions: ANI-F: 1.

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

PAM-240/360 Public Address Amplifier

CMA-100. Counter Measures Amplifier. Owner s Guide

INTRODUCTION. Please read this manual carefully for a through explanation of the THETA Head and its functions. PRECAUTIONS

VX-3000 Series Voice Alarm and Public Address System

Microphone audio, from the MFJ-1278B to your transmitter. Ground, audio and PTT common. Push-to-talk, to allow the MFJ-1278B to key your transmitter.

12V MINI AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

PLENA SOLUTIONS F E A T U R E S PUBLIC ADDRESS GUIDE

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

M-300 Mono power amplifier User s guide

MAINTENANCE MANUAL AUDIO AMPLIFIER BOARD 19D904025G1 (MDR) AUDIO AMPLIFIER BOARD 19D904025G2 (MDX)

Modbus communication module for TCX2: AEX-MOD

The Aleph 2 is a monoblock 100 watt audio power amplifier which operates in single-ended class A mode.

Transcription:

PA0688 Microphone PreAmplifier Module Installation and Operating Instructions Description The PA0688 Microphone Preamplifier board is intended to provide emergency and nonemergency microphone preamplification to line level with or without PTT function. Overview The PA0688 Microphone Preamplifier Module is designed for use with Vigilant EWIS systems; TGen2, TGEN 50 and QE90. It contains a microphone preamplifier with automatic level control, and two relays which are operated by the PTT switch on the microphone. Refer to Figure 1. The first relay switches the line level output between (a) line level input terminals () and (b) the output of the preamplifier, and can be used to allow several PA0688 preamps to be connected in series to the same panel input. The second relay is a twopole changeover relay which can, for example, be used to disconnect speakers in close proximity to the microphone when the microphone is in use to prevent audio feedback. It can also be used for various other functions, e.g. to provide a switch input to a QE90 to indicate that Paging is required. Audio transformers should be used in conjunction with the PA0688: for isolation, e.g. where the module is to feed multiple TGEN units for balancing, in order to reduce noise pickup in situations where long lines are to be used to feed unbalanced inputs. Refer to Figures 2, 6 and 7 for details. IN Relay Coils SPEAKER IN PTT Switch PTT Out SPEAKER OUT SPARE Figure 1 PA0688 Preamp Block Diagram Connection and Operation QE90 The PA0688 microphone preamplifier can be connected to the QE90 in many ways. One example is to provide local paging to several QE90 amplifiers, using the QE90 amplifier local inputs. Refer to Figure 2. In Figure 2 there are two preamps connected in a daisy chain so that either may be used. In the event of PTT being pressed on both at the same time, the one closest to the QE90 will have priority. The connection to the QE90 amplifier local inputs has been isolated by a transformer as these inputs are unbalanced and the use of the transformer will provide a reduction in hum and noise. The SPKR IN and SPARE terminals on the PA0688 have been used to obtain clean contacts which close when PTT is operated, and these have been wired to a GP or FIP input on the QE90 that has been programmed by the manufacturer to disable background music to the relevant amplifiers when the local paging is in use. LT0371 Issue 1.10 7 February 2018 Page 1 of 6

All audio cables should be shielded and the shields connected to ground at the QE90. PTT PA0688 SPKR IN SPARE SUPPLY GP or FIP Input PTT PA0688 SPKR IN SPARE QE90 Amplifier local input SUPPLY 600 Ohm Line Isolating Transformer Possible second amplifier local input Figure 2 Using PA0688 Preamp with QE90 Local Inputs Note An ALIM9706 could be used for the 600 Ohm Isolating Transformer. Refer to Figure 5. Another example is shown in Figure 3. In this case the output of the preamp is connected to the QE90 MUSIC input, with the zones requiring paging fieldprogrammed into the QE90. This example also shows how the PA0688 can be used to disconnect speakers near the microphone to prevent feedback. Other Speakers SPEAKER OUTPUT Speaker Near Microphone Speaker Matching Transformer SPKR OUT SPKR IN QE90 PTT PA0688 MUSIC IN SUPPLY Figure 3 Using PA0688 Preamp with QE90 Music Input NONEMERGENCY ROPHONE ON TGen2 TGen2 EWS has two audio inputs for connecting nonemergency background music sources or paging facilities. The PA0688 microphone PreAmp can be used to boost a remote microphone voltage to feed into the TGen2 Audio Input for remote paging. The PreAmp needs to be located with the microphone and is supplied with 24Vdc power. Figure 4 shows the wiring arrangement. LT0371 Issue 1.10 7 February 2018 Page 2 of 6

Note: Screened cable should be used for the audio connections between preamp modules and the T Gen2, with the screen connected to the input at the TGen2. The paging microphone closest to the TGen will have priority if both microphone PTT buttons are pressed at the same time. The 24V feed for the PreAmps should be separately fused so a fault does not remove power to the TGen2. PA0688 ROPHONE PREAMP TGen2 SPEAKER OUT SPARE 24V AUD IN AUD IN GP IN PA0688 ROPHONE PREAMP SPEAKER OUT SPARE 24V Figure 4 Microphone PreAmp to TGen2 TGEN 50 Output Level The PA0688 can be used for paging facilities to boost the voltage from a microphone to the TGEN's music input. In standard form, the PA0688 s output does not provide the 2.53V RMS signal level required by the Music Input of TGEN 50. To solve this, resistor R28 on the PA0688 Microphone Preamp should be changed to 10k. Wiring NonEmergency Microphone One or more PA0688 Microphone Preamps can be wired to the TGEN as in Figure 5. Screened cable should be used for the audio connections between preamp modules and the TGEN, with the screen connected to the input (Pin 2) of J9 at the TGEN. The paging microphone closest to the T GEN will have priority if both PTT buttons are pressed at the same time. PA0688 ROPHONE PREAMP OUT IN 1 2 MUSIC J9 TGEN R28=10k 24V POWER PA0688 ROPHONE PREAMP OUT IN R28=10k OPTIONAL (REPEAT FOR FURTHER ROPHONES) Figure 5 Unbalanced Configuration, PA0688 to TGEN 50, Nonemergency Microphone LT0371 Issue 1.10 7 February 2018 Page 3 of 6

If the TGEN and preamp(s) are not mounted close together then to increase immunity to any ambient electrical noise, it is recommended that screened cable should be used and an ALIM9706 should be located at the TGEN input. This is shown in Figure 6. Note that the segments of screened cable connecting the preamp modules to the TGEN must have their shields wired together and connected to the input of J9 (Pin 2) or J1 at the TGEN. Again the paging microphone closest to the TGEN will have priority if both PTT buttons are pressed at the same time. Note that there are volume controls on both the ALIM and preamps(s), we recommend setting the ALIM volume to maximum and adjusting each microphone separately at its preamp. Figure 6 Balanced Configuration, PA0688 to TGEN 50, Nonemergency Microphone Emergency Microphone For TGEN In the above arrangements, the remote microphone will not override tones, digitised speech, or PA messages generated by the emergency microphone plugged into connector J1. For an emergency microphone located at the TGEN a suitable prewired handheld microphone with PTT switch and plug is available (ME0290). For remotely located emergency microphone(s) we suggest the arrangement shown in Figure 7. Note that the segments of screened cable connecting the preamp modules to the TGEN must have their shields wired together and must be connected to the input of J9 (Pin 2) or J1 at the TGEN. Again, the microphone closest to the TGEN will have priority if both PTT buttons are pressed at the same time. Note that there are volume controls on both the ALIM and preamps(s). We recommend setting the ALIM volume to maximum and adjusting each microphone separately at its preamp. SHIELD PA0688 ROPHONE PREAMP SPEAKER IN SPARE PA0846/646 ALIM 47k A A 47k A A INPUT OUTPUT LK1A, LK2A NOT FITTED, LK3A FITTED 23 TGEN J1 PA0688 ROPHONE PREAMP OPTIONAL (Repeat for further microphones) 24V Power SPEAKER IN SPARE Figure 7 Remote Emergency Microphone(s) for TGEN 50 LT0371 Issue 1.10 7 February 2018 Page 4 of 6

PA0688 Specifications Board Dimensions: Shipping Weight: 157 x 93 x 25mm (lwh) 0.25kg Temperature: Operating 0 º C 45 º C Humidity: Operating Voltage: Operating Current: Output: (1 khz test tone) Nominal Output Impedance: Inputs: Storage 0 º C 70 º C. <95% relative humidity (noncondensing) 24V (1728V) from panel. 35mA (55mA PTT operated) 500700 mv RMS for 1mV in @<10% distortion 600800 mv RMS for 10mV in @<1% distortion 6001000 mv RMS for 40mV in @<1% distortion 600 Ohm,,, (supply) Microphone Input: Suitable for dynamic microphone, 600 Ohm nominal @ 1kHz Accessories included with PA0688 None. ME0290 is a suitable PTT microphone (ordered separately). LT0371 Issue 1.10 7 February 2018 Page 5 of 6

Manufactured Johnson Controls Distributed by: 17 Mary Muller Drive, PO Box 19545 by: Christchurch, New Zealand Tel 643389 5096 Fax 6433895938 2017. Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. LT0371 Issue 1.10 7 February 2018 Page 6 of 6