Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Similar documents
Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

MiniMe 2-Wire Ultrasonic Level Transmitter Model LU12/LU13/LU14 Owner s Manual

Ultrasonic Level Transmitter Model LU30 Owner s Manual

Ultrasonic Level Transmitter Model LU20 Owner s Manual

MiniMe Two-Wire Ultrasonic Level Transmitter Model LU11/12/13/14 Owner s Manual

EchoSonic II Manual 09 JUL 08 Revision A

EchoSonic Two-Wire Ultrasonic Level Transmitter Model LU05/11/12/13 Owner s Manual

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual

EchoNet Wireless Level Transmitter Model LN20 Owner s Manual

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

EchoSwitch Multi-Point Ultrasonic Level Switch Model LU71/72/73/75 Owner s Manual

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

EchoSonic II Manual. LU23-0, LU27-0, LU28-0, LU29-0, LU23-1, LU27-1, LU28-1, LU29-1 Series

LPU-2127 User Manual

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Ultrasonic level transmitter, non-contact

Princo MagneLevel Model LML

2-wire level transmitter

Echotel Model 910 Ultrasonic Level Switch

Table of Contents. Safety Notices

TRANSDUCER IN-LINE AMPLIFIER

742A Series Resistance Standards

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Non-Submersible Industrial Pressure Transducer

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

80i-600A AC Current Probe

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

TRANSDUCER IN-LINE AMPLIFIER

Instruction Manual. HB Series Mini Level Sensor

Kotron Sentinel Model 804 RF Level Transmitter

Instruction Manual. LD/LA Level Transmitter. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Model 113 Scintillation Preamplifier Operating and Service Manual

OPERATING INSTRUCTIONS

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

LT3000 ULTRASONIC LEVEL TRANSMITTER

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Echotel Model 910 Ultrasonic Level Switch

Kotron Sentinel Model 804 RF Level Transmitter

2.75" x 2.20" x 3.70" 70mm x 56mm x 94mm lb. / kg.

Keychain Radio Remote Control System

User s Guide Instructions for Installation and Operation

The transducer component converts the measured signal and displays the actual value.

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

Kotron Model 82 CE RF Level Transmitter

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

C5000 & C5000NF PULSE INITIATOR. Introduction

BC145 SIGNAL ISOLATOR BOARD

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Model 9305 Fast Preamplifier Operating and Service Manual

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

INSTRUCTION MANUAL INF Fax: (503)

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Global Water Instrumentation, Inc.

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Programmable K-Factor Scaler B and Programming Software Kit B

DM-46 Instruction Manual

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

K-FACTOR SCALER B & B

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

TABLE OF CONTENTS WARRANTY

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

GPI Wireless Receiver

PULSE OXIMETRY SIMULATOR

Bulk Current Injection Probe Test Procedure

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Echotel Trident 91S/92S Ultrasonic Level Switches

INSTRUCTION MANUAL UTL260

Broadband Step-Up Transformer. User Manual

CURATED CARTESIAN VANITY

POWER TRACE TM TASCO, INC.

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

MP Series Radar Transmitter Installation & Operation Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Explosion Proof Page/Talk Paging Amplifier

Questions? Call Toll-Free

Log Periodic Antenna

Soil Moisture Smart Sensors (S-SMx-M005)

4. CONNECTIONS. Make sure all connections to and in your Universal Rectifier are tight.

SSR-150xxx-40VL-12P-xC-xxxCS

10 Ton Pull Back Ram

Planishing hammer stand For use with SKU Planishing hammer

Angular Rate Sensor. Owner's Manual

Classic Series Public Address Amplifiers C10 & C20 Models

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

OWNER S MANUAL. Distributed by ASLI, 1011 Centre Road, Wilmington, DE Tools Required: Allen Wrench

User Guide. Digital AC/DC Clamp Meter Model 38394

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Model 9302 Amplifier-Discriminator Operating and Service Manual

Top Mount. See Installation 2 on page 2

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

Transcription:

Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If for some reason your product must be returned for factory service, contact Flowline Inc. to receive a Material Return Authorization number (MRA) first, providing the following information: 1. Part Number, Serial Number 2. Name and telephone number of someone who can answer technical questions related to the product and its application. 3. Return Shipping Address 4. Brief Description of the Symptom 5. Brief Description of the Application Once you have received a Material Return Authorization number, ship the product prepaid in its original packing to: Flowline Factory Service MRA 10500 Humbolt Street Los Alamitos, CA 90720 To avoid delays in processing your repair, write the MRA on the shipping label. Please include the information about the malfunction with your product. This information enables our service technicians to process your repair order as quickly as possible. Ricochet Level Model LA15 Owner s Manual Version 1.2A 1999 FLOWLINE Inc. All rights reserved. Manual # LA900002 5/99 WARRANTY Flowline warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service for a period which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products. This warranty covers only those components of the products which are non-moving and not subject to normal wear. Moreover, products which are modified or altered, and electrical cables which are cut to length during installation are not covered by this warranty. Flowline s obligation under this warranty is solely and exclusively limited to the repair or replacement, at Flowline s option, of the products (or components thereof) which Flowline s examination proves to its satisfaction to be defective. FLOWLINE SHALL HAVE NO OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSON- AL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON. This warranty does not apply to products which have been subject to electrical or chemical damage due to improper use, accident, negligence, abuse or misuse. Abuse shall be assumed when indicated by electrical damage to relays, reed switches or other components. The warranty does not apply to products which are damaged during shipment back to Flowline s factory or designated service center or are returned without the original casing on the products. Moreover, this warranty becomes immediately null and void if anyone other than service personnel authorized by Flowline attempts to repair the defective products. Products which are thought to be defective must be shipped prepaid and insured to Flowline s factory or a designated service center (the identity and address of which will be provided upon request) within 30 days of the discovery of the defect. Such defective products must be accompanied by proof of the date of purchase. Flowline further reserves the right to unilaterally wave this warranty and to dispose of any product returned to Flowline where: a. There is evidence of a potentially hazardous material present with product. b. The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and liabilities of Flowline under it are exclusive and instead of, and the original purchaser hereby waives, all other remedies, warranties, guarantees or liabilities, express or implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTIC- ULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF MERCHANT ABILITY OF THE PRODUCTS. This warranty may not be extended, altered or varied except by a written instrument signed by a duly-authorized officer of Flowline, Inc.

SPECIFICATIONS Step One : 3.6" to 6' (9 cm to 1.8 m) Accuracy: ±.25% of span in air Resolution: 0.125 (3 mm) Frequency: 83 khz (nominal) Pulse rate: 2 pulses per second Beam width: 8 conical Dead band: 3.6 (9 cm) voltage: Max loop resistance: 600 Ohms @ 36 VDC Signal output: 4-20, Fail-safe diagnostics: Reverts to 22 LED flashing Temperature rating: F: -40º to 140º C: -40º to 60º Temp. compensation: Automatic over entire range Pressure rating: 30 psi (2 bar) @ 25 C., derated @ 1.667 psi (0.113 bar) per C. above 25 C. Enclosure rating: NEMA 4X / IP65 Enclosure material: Polypropylene, U.L. 94VO Transducer materials: PVDF Mounting threads: 3/4 NPT (3/4" G) Mounting gasket: Viton (3/4" G) metric only Conduit connection: 1/2 NPT CE compliance: EN 50082-2 immunity EN 55011 emission (pending) About Technology: An ultrasonic sound wave is pulsed five times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor based electronics measures the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below. 6 8 Cone 4-20 Feet Radius Inches Radius Radius cm 1 2 3 4 5 6 1.2 2.1 2.9 3.7 4.9 5.4 3.1 5.2 7.3 9.5 11.6 13.7 Operating Pressure (psi) Temperature/Pressure Derating 35 Unacceptable 30 25 20 15 Acceptable 10 05 00-40 -20 00 20 40 60 Temperature ( C) Ambient Sensor Temperature ( C) Maximum Temperature/Voltage Derating Continuous 20 Curve 100 80 60 40 20 Unacceptable Acceptable 0 12 16 20 24 28 32 36 Operating Voltage (VDC) Max. Series Resistance (Ohms) 700 600 500 400 300 200 100 000 Flowline Ricochet Electrical Loading Limits Unacceptable Acceptable 12 18 24 30 36 Volyage (VDC)

SAFETY PRECAUTIONS Step Two About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on the Ricochet continuous non-contact level transmitter from FLOWLINE: LA15-5001 and LA15-5061. Please refer to the part number located on the sensor label to verify the exact model which you have purchased. User s Responsibility for Safety: FLOWLINE manufactures a wide range of liquid level sensors and technologies. While each of these sensors is designed to operate in a wide variety of applications, it is the user s responsibility to select a sensor model that is appropriate for the application, install it properly, perform tests of the installed system, and maintain all components. The failure to do so could result in property damage or serious injury. Proper Installation and Handling: Because this is an electrically operated device, only properlytrained staff should install and/or repair this product. Use a proper sealant with all installations. Note: Always install the 3/4 Viton gasket with the LA15-5061. The G threaded version of the Echotouch will not seal unless the gasket is installed properly. Never overtighten the transmitter within the fitting. Always check for leaks prior to system start-up. Wiring and Electrical: A supply voltage of is used to power the LA15 transmitter. The sensor systems should never exceed a maximum of 36 volts DC. Electrical wiring of the sensor should be performed in accordance with all applicable national, state, and local codes. Material Compatibility: The Ricochet enclosure is made of Polypropylene (PP). The transducer is made of Polyvinylidene Fluoride (PVDF). Make sure that the model which you have selected is chemically compatible with the application liquids it will contact. Enclosure: While the transmitter housing is liquid-resistant when installed properly, it is not designed to be immersed. It should be mounted in such a way that the enclosure and diaphragm do not come into contact with fluid. Make a Fail-Safe System: Design a fail-safe system that accommodates the possibility of transmitter or power failure. In critical applications, FLOWLINE recommends the use of redundant backup systems and alarms in addition to the primary system. Flammable, Explosive and Hazardous Applications: The LA15 transmitter systems should not be used within flammable or explosive applications. WIRING Step Three Wiring to Terminal: The Ricochet arrives from the factory pre-calibrated and preassembled. Use the following instructions below for wiring to the LA15. 1. First, remove the cap of the transmitter: 4-20 2. Look for the terminal block with two terminals. 3. Remove the terminal block to wire the LA15. The terminal to the right is positive and the terminal to the left is negative. 4. When finished attaching the wires, assemble the LA15 using steps 1-3 in reverse. Warning Always install the 3/4" Viton gasket with all versions of the LA15-5061. The G threaded version of the Ricochet will not seal unless the gasket is installed properly.

WIRING Step Four Follow the instructions in Step 3 for wiring to the Ricochet. 1. Wiring to a FLOWLINE Continuous Controller (LC52): Connect the (+) terminal to the positive 24 VDC, 25 terminal on the LC52 controller. Connect the (-) terminal to the terminal on the LC52 continuous controller (See illustration below). Check LC52 instruction manual for setting the LC52 for loop powered operation. 4-20 PWR PROPORTIONAL CONTROLLER LATCH ON OFF INVERT RELAY 1 DELAY OFF SET SPAN RLY1 RLY2A RLY2B 0% INPUT 100% INVERT RELAY 2 EASY CAL DELAY 4 20 OP UP DOWN SET INSTALLATION Step Five FLOWLINE s LA15 transmitter may be installed through the top wall of a tank. Installation requires a 3/4" NPT fitting or blind flange. 1. Install the appropriate 3/4" fitting in the top wall of the tank. Prior to installation, make sure that the fitting has been installed properly and checked for leaks. Use a proper sealant at the time of installation to ensure a liquid-tight seal. Secondly, make sure that the fitting s threads are not damaged or worn. 2. Insert the into the fitting and tighten to hand tight. 3. Always check for leaks prior to system start-up. To ensure proper installation, a complete leak test and simulation of actual process conditions should be preformed. Flange Fitting Installation Installation 2. Wiring to a Two-Wire Loop Powered Indicator: The LA15 requires power and an indicator which receives a 4-20 current input. Connect the (+) terminal of the LA15 transmitter to the positive VDC terminal on the power supply. Connect the (-) terminal on the LA15 to the (+) terminal on the loop indicator. Connect the (-) of the loop indicator to the (-) of the power supply (See illustration below). 4-20 DC Power + - 3. Wiring to a Typical PLC: The LA15 requires a PLC which provides a excitation and receives a 4-20 current input. Connect the (+) terminal of the LA15 transmitter to the positive VDC power terminal. Connect the (-) terminal on the LA15 to the (+) channel on the PLC. Connect the (-) of the PLC to the (-) of the power terminal (See illustration below). 4-20 DC Power + - * 250 Ω resistor typically internal to PLC 6 5 4 3 2 1 0 A Typical PLC 250Ω Warning Do not install the Ricochet in pressurized applications above 30 psi. Always install the 3/4" Viton gasket with all versions of the LA15-5061. The G threaded version of the Ricochet will not seal unless the gasket is installed properly.erly and checked for leaks. Use a proper sealant at the time of installation to ensure a liquidtight seal. Secondly, make sure that the fitting s threads are not damaged or worn. Avoid Interference from side of tank Avoid Interference from obstructions in tank Do not install LA15 at an angle LA15 will not operate in vacuum VACUUM

CALIBRATION Step Six The Ricochet is factory calibrated with a fixed measurement span of 6 feet. The 4 position is located 72" from the transducer face of the LA15. The 20 position is located 3.6 from the transducer face. Refer to the current to distance and distance to current conversion charts in step seven for reading the current output. 1. Connect a multimeter in series to read the current output. 2. Verify that as the distance from the liquid to the LA15 increases, the current signal decreases. 3. Verify that as the distance from the liquid to the LA15 decreases, the current signal increases. Power 4 com 5 6 (+) Power 19 20 21 com (+) CALIBRATION Step Seven to Conversion Chart (Nominal) 20 19 18 17 16 15 to Conversion Chart (Nominal) 3.6 06 12 18 24 03.6 07.9 12.1 16.4 20.7 25.0 20.0 19.4 18.0 16.6 15.2 14 13 12 11 10 09 30 36 42 48 54 29.2 33.5 37.8 42.1 46.3 50.6 13.8 12.4 11.0 09.6 08.2 08 07 06 05 04 60 66 72 54.9 59.2 63.5 67.7 72.0 06.8 05.4 04.0 20 3.6" 72" 20 3.6" 4 LED Indication The Ricochet features a single LED indicator which is used for power and fail-safe indication. During normal operation, the LED will be ON continuously to indicate that the transmitter has power and a strong echo signal return strength. Should the LED begin to FLASH, it indicates that the transmitter has no signal return strength and the device has gone into a fail-safe condition. During the fail-safe condition, the current will increase up to 22 and hold until the acoustic signal is reacquired. Once reacquired, the LED will turn back ON continuously and the current will indicate the appropriate measured value. 4 68.4" 72" LED 4-20

MAINTENANCE Step Eight Step Nine General: The LA15 series level transmitter itself requires no periodic maintenance except cleaning as required. It is the responsibility of the user to determine the appropriate maintenance schedule, based on the specific characteristics of the application liquids. Cleaning Procedure: 1. Power: Make Sure that all power to the transmitter, controller and/or power supply is completely disconnected. 2. Sensor Removal: In all through-wall installations, make sure that the tank is drained well below the sensor prior to removal. Carefully, remove the sensor from the installation. 3. Cleaning the Sensor: Use a soft bristle brush and mild detergent, carefully wash the transducer of the LA15. Do not use harsh abrasives such as steel wool or sandpaper, which might damage the transmitter's surface. Do not use incompatible solvents which may damage the PVDF transducer or the transmitters PP body. 4. Sensor Installation: Follow the appropriate steps of installation as outlined in the installation section of this manual.