GE Critical Power. GTX Series. Automatic Transfer Switch (ATS)

Similar documents
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

SECTION AUTOMATIC TRANSFER SWITCH

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

2. INSPECTION PROCEDURES, COMPONENTS IDENTIFICATION AND STANDARD SPECIFICATIONS

MAJORSINE Power Inverter

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

0E4343-F LOAD CIRCUIT BREAKER ACCESS DOOR P/N 0E4708 REV.- TVSS STATUS UTILITY FAULT ( RED - SURGE FAILURE )

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

TOSHIBA International Corp

Orbital GFI Inverter Series

Owner s Manual POWER SYSTEMS, INC. GENERACR. Automatic Transfer Switch. Model Numbers , , ,

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

PACSystems* RX3i IC695MDL765

O & M Manual for 1600A (480 Vac) ATC-300+/800 & Non-Automatic, 3-Position Fixed Mount Contactor Based Transfer Switch

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

SUGGESTED SPECIFICATION DUAL OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

Technical Data Sheets

O & M Manual for the EATON ATC-300 Automatic Transfer Switch Controller

REX12 Electronic Circuit Protector

INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

StatiVolt. Inverter UPS Systems. Features. Contents

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

APS M1P Single-phase Micro-inverter Installation and User Manual

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

SECTION 16496G CONTACTOR BASED AUTOMATIC TRANSFER SWITCHES LOW VOLTAGE

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

JBus/Modbus Communication Card

SPECIFICATION, CONTROLS AND ACCESSORIES

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

REDKOH INDUSTRIES SWITCH MODE POWER SUPPLY DEMO UNIT

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Page/Talk Hazardous Area Paging Amplifier

APS M1P Single-phase Micro-inverter Installation and User Manual

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Phoenix DX Clean Power (18 Pulse) AC Drive

Solectria Renewables Modbus Level 5 For models PVI KW

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

RDV-X/RDV-P Robot driver Only for pulse train control

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

SPECIFICATION, CONTROLS AND ACCESSORIES

Fluke 3540 FC Three-Phase Power Monitor

Explosion Proof Page/Talk Paging Amplifier

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

ø30 ARN/ARNS Series Mono-lever Switches Switches

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

PACSystems* RX3i IC695MDL664-BB

Oil & Gas / Heavy Industry Type 2REX-A-NA-SSI

Power Processor - Series 700F 10KVA to 150KVA

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

BC145 SIGNAL ISOLATOR BOARD

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

VIP Current & Power Multimeter

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

Pressure Transmitter SIL

Level Lance Model 5100

Installation and Operating Instructions. Power IT Power Factor Controller RVC

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

VersaMax* Analog Input, 16-Bit RTD Module

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

MIT415 Insulation tester

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

DM-45 Digital Multimeter

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Computer-14d - xx - 144a

Always there to help you. Register your product and get support at AJ3232. Question? Contact Philips.

Shaft Absolute Vibration Monitor Specifications

DeltaV SIS Logic Solver

To be automatically connected to the nearest North American Technical Sales Office:

Technical Instructions Document No EA GQD June 23, OpenAir

RuggedNet GPoE+/Si Unmanaged 4 and 8-Port PoE/PoE+ Switch. User Manual. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

R4850G1 Rectifier User Manual V1.3

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

MIT400/2 CAT IV Insulation testers

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

SENTINEL XR PLUS 5-10kVA

Material: Weight: Shaft Loads:

Model 25B-F/S/L Solid Shaft Low Line Incremental Optical Rotary Encoder

Solectria Renewables Modbus Level 6 For models SGI 500XT

REX12 Electronic Circuit Protector

Fluke 3540 FC Three-Phase Power Monitor

Speed and Key Monitor Specifications

Transcription:

GE Critical Power GTX Series Automatic Transfer Switch (ATS)

GTX Series GE has been providing customers with reliable ATS power switching systems since the 1920 s. GE s GTX Series Automatic Transfer Switches (ATS) are used to provide a continuous source of power for critical loads by automatically transferring from source1 power to source2 power in the event that source1 voltage encounters undervoltage, phase loss or under frequency. Voltage sensing and system control can be performed via an optional state-of-the-art MX70 microprocessor providing highly accurate control. GE transfer switches are designed for use in emergency or standby systems supporting all types of loads at fully rated current, delivering reliability and ease of operation. Performance Features and Construction True double throw operation where the single Solenoid Design is inherently inter-locked and prevents contacts from inadvertently stopping between sources or from being in contact with both sources at the same time. Highly reliable, Low MTBF (mean time between failure) Special wiring plug design prevents incorrect installation Smart diagnostic program and inphase monitor (available in the MX70 option) Arc quenching grids, enclosed arc chamber, and wide contact air gap Neutral pole break-last-close-first design,neutral contact is on the same shaft as other poles Ease of operation Fast contact transfer speed 120ms Technical Data RATED CURRENT (IN) 40A, 63A, 80A 100A, 125A 160A, 200A, 250A 320A, 400A Standard Voltage, Frequency Enclosure IEC60947-6-1: 2013 Revision; GB14048.11-2008 Revision 120/240V for 2 poles; 208/220/240/380/400/416V for 3 Poles, 4 Poles; 50&60Hz Power panel only, Open style, IP20 (Nema1), IP24 (Nema3R) options Utilization Category AC-33A AC-33A AC-32A AC-32A Making Breaking Capability (x time rated amperage In, number of operations (cycles)) 10 In, 50 cycles 10In, 50 cycles 3In, 50 cycles 3In, 50 cycles Endurance 3000 cycles at 2x rated current 3000 cycles at 2x rated current 6000 cycles at 1x rated current 4000 cycles at 1x rated current Rated conditional short circuit current 35kA @ 416V 35kA @ 416V 50kA @ 416V 65kA @ 416V Contact transfer time 85ms 90ms 90ms 120ms Transfer time with MX70 controller option 1100ms 1500ms 1500ms 2000ms Product size (2 Poles) HxWxD Power Panel Only 209x172.8x115mm (8.23x6.8x4.53in) 230x222x114mm (9.06x8.74x4.49in) 230x238x114mm (9.06x9.37x4.49in) 287x303x152mm (11.30x11.93x5.98in) Product size (3 Poles) HxWxD Power Panel Only 209x194x115mm (8.23x7.65x4.53in) 230x252x114mm (9.06x9.92x4.49in) 230x278x114mm (9.06x10.94x4.49in) 287x363x152mm (11.30x14.29x5.98in) Product size (4 Poles) HxWxD Power Panel Only 209x216x115mm (8.23x8.50x4.53in) 230x282x114mm (9.06x11.10x4.49in) 230x318x114mm (9.06x12.52x4.49in) 287x423x152mm (11.30x16.65x5.98in) Operating Temp. / Humidity -5 o C to +40 o C / 5%-95% (non-condensing) Recommended Cable Size (Cu) * 10mm 2, 16mm 2, 25mm 2 35mm 2, 50mm 2 70mm 2, 95mm 2, 120mm 2 185mm 2, 240mm 2 * For aluminum cable sizing please reference IEC 60228 2 GE GTX Brochure www.gecriticalpower.com

Power Panel 2 3 9 4 5 6 1. Main transfer operator 2. Nameplate (includes serial number) 3. Switch position indication 7. Source2 terminals 8. Load terminals 9. Voltage sensing terminals 10 1 4. Source1 terminals 5. Arc chamber 10. Manual operating maintenance handle 7 6. A3/A4 limit switches 8 6 Electrical Schematic Diagram BR = Bridge Rectifier SN = Normal position limit switch SE = Emergency position limit switch CNE = Main transfer operator SCN/SCE = Operator limit switch Switch on Normal Source Description Method of Operation: If source1 fails, a circuit is closed to start the generator. When source2 reaches a predetermined output, the controller will signal to connect the load to source2. When source1 is restored to the preset point, the controller will send command to reconnect load to source1. Utility-Utility configuration: Both source1 and source2 are from utility feeds. Utility-Genset configuration: Source1 is from utility and source2 is from a generator. Notice For GTX installation please reference operation manual. Warning! Turn off source1 and source2 power before using the handle to manually operate the GTX, or possibly cause severe injury. To keep GTX structure lubricated, regular maintenance is necessary (reference operation manual). 3 GE GTX Brochure www.gecriticalpower.com

MX70 Microprocessor Control Panel D C E A B F G H I A. S1 (Utility) Available Green LED. - When on, indicates source is acceptable. B. S1 (Utility) Position Green LED. - When on, indicates ATS is connected to Utility C. S2 (Generator) Available Red LED. - When on, indicates source is acceptable. D. S2 (Generator) Position Red LED. - When on, indicates ATS is connected to Generator. F. TEST: Press and hold for one second to simulate a power outage, start Generator and transfer the ATS to source2 G. EXERCISE SET: Sets an automatic exerciser H. BYPASS TIMER: Press while timing is in process, bypass any remaining countdown timer I. CANCEL: Depending on the current state of the GTX operation, ends specific functions or indications E. Timing/In-phase Amber LED. - When blinking, indicates the ATS is timing a Delay - When on steady, indicates the ATS is waiting for both sources to synchronize with each other. - When off and other lights are on, indicates the ATS is working without active time delays or alarms. Optional MX70 Controller Dimensions Unit: mm/in 4 GE GTX Brochure www.gecriticalpower.com

Power Panel Product Dimensions 40-80Amps 100-125Amps 160-250Amps 260-400Amps 40-80 Amps Unit: mm/in 2 POLE 3 POLE 4 POLE A 172.8 / 6.80 194.4 / 7.65 216 / 8.50 B 66.2 / 2.61 87.8 / 3.46 109.4 / 4.31 100-125 Amps Unit: mm/in 2 POLE 3 POLE 4 POLE A 222 / 8.74 252 / 9.92 282 / 11.10 B 83 / 3.27 113 / 4.45 143 / 5.63 160-250 Amps Unit: mm/in 2 POLE 3 POLE 4 POLE A 238 / 9.37 278 /10.94 318 / 12.52 B 103 / 4.06 143 / 5.63 183 / 7.20 260-400 Amps Unit: mm/in 2 POLE 3 POLE 4 POLE A 303 / 11.93 363 / 14.29 423 / 16.65 B 276.5 / 10.89 336.5 / 13.25 396.5 / 15.61 5 GE GTX Brochure www.gecriticalpower.com

Enclosure Dimensions (mm) F-2000MP -- 40-250Amp, IP20 (NEMA 1) F-2001MP -- 40-250Amp, IP24 (NEMA 1) F-2002MP -- 320-400Amp, IP20 (NEMA1) F-2003MP -- 320-400Amp, IP24 (NEMA 3R) CABINET NUMBER DIMENSION UNIT: mm/in F-2000MP -- 40-250Amp, IP20 (NEMA 1) F-2001MP -- 40-250Amp, IP24 (NEMA 1) F-2002MP -- 320-400Amp, IP20 (NEMA1) F-2003MP -- 320-400Amp, IP24 (NEMA 3R) 457x259x610 / 18x10.2x24 470x268.5x612 / 18x10.6x24.1 610x363.5x1168 / 24x14.3x46 610x385x1170 / 24x15.2x46 6 GE GTX Brochure www.gecriticalpower.com

Shipping Weights and Packing Dimensions Power Panel Only FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) DIMENSION H x W x L UNIT: mm/in 80A 5.76 / 12.70 6.38 / 14.07 7 / 15.43 300 x 275 x 205 / 11.8x10.8x8.1 125A 7.9 / 17.42 9 / 19.84 10 / 22.05 366 x 300 x 205 / 14.4x11.8x8.1 250A 8.72 / 19.22 10.11 / 22.29 11.5 / 25.35 400 x 275x 205 / 15.7x10.8x8.1 400A 17.34 / 382.15 20.42 / 45.02 23.5 / 51.8 547 x 400 x 272 / 21.5x15.7x10.7 Open Style FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) DIMENSION H x W x L UNIT: mm/in 80A 7.1 / 15.65 7.64 / 16.84 8.18 / 18.03 480 x 265 x 190 / 18.9x10.4x14.4 125A 9.94 / 21.91 10.86 / 23.94 11.78 / 25.97 520 x 295 x 190 / 20.5x11.6x7.5 250A 11.94 / 26.32 13.16 / 29.01 14.38 / 38.32 560 x 295 x 190 / 22.0x11.6x7.5 400A 19.22 / 42.37 22.3 / 49.16 25.38 / 55.95 690 x 410 x 270 / 27.2x16.1x10.6 Enclosure Style IP20 (Nema 1) FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) DIMENSION H x W x L UNIT: mm/in 80A 7.1 / 15.65 7.64 / 16.84 8.18 / 18.03 690 x 530 x 330 / 27.2x20.9x13.0 125A 9.94 / 21.91 10.86 / 23.94 11.78 / 25.97 690 x 530 x 330 / 27.2x20.9x13.0 250A 11.94 / 26.32 13.16 / 29.01 14.38 / 38.32 690 x 530 x 330 /27.2x20.9x13.0 400A 19.22 / 42.37 22.3 / 49.16 25.38 / 55.95 1400 x 870 x 450 / 55.1x34.3x17.7 Enclosure Style IP24 (Nema 3R) FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) DIMENSION H x W x L UNIT: mm/in 80A 8.46 / 18.65 9 / 19.84 9.54 / 21.03 690 x 530 x 330 / 27.2x20.9x13.0 125A 11.3 / 24.91 12.22 / 26.94 13.14 / 28.97 690 x 530 x 330 / 27.2x20.9x13.0 250A 13.3 / 29.32 14.52 / 32.01 15.74 / 34.70 690 x 530 x 330 / 27.2x20.9x13.0 400A 25.58 / 56.39 28.66 / 63.18 31.74 / 69.98 1400 x 870 x 450 / 55.1x34.3x17.7 7 GE GTX Brochure www.gecriticalpower.com

Order Code DIGIT 1,2,3 SERIES DIGIT 4 AMPERE RATING DIGIT 5 #SWITCHED POLES DIGIT 6 APPLICATION DIGIT 7 MICROPROCESSOR CONTROLLER DIGIT 8 ENCLOSURE TYPE DIGIT 9 ACCESSORIES DIGITS 10,11 VOLTAGE, # PHASES, # WIRES, FREQUENCY DIGITS 12-18 OTHER OPTIONS GTX D E S S A S 30 XXXXXXX A 40 A B 63 A C 80 A D 100 A E 125 A F 160 A G 200 A H 250 A I 320 A J 400 A B 2 Pole E 3 Pole F 4 Pole S Utility - Generator Switching U Utility - Utility Switching X *None (Power Panel Only) S MX70 X *None (Power Panel Only) *Digit 8 for Enclosure must = X X *None (Power Panel Only) A Enclosure IP20 (NEMA 1) B None (Open Style) C Enclosure IP24 (NEMA 3R) S Standard X *None (Power Panel Only) For 400V with MX70 microprocessor controller, the operating sensing fail voltage = 85% nominal, and return voltage = 95% nominal. 10 120V, 1PH, 2W, 60HZ 11 120V, 1PH, 2W, 50HZ 20 120/240V, 1 PHASE, 3 WIRE, 60HZ 21 120/240V, 1 PHASE, 3 WIRE, 50HZ 30 240V, 3PH, 3W, 60HZ 31 240V, 3PH, 3W, 50HZ 40 120/208V, 3 PHASE, 4 WIRE, 60HZ 41 127/220V, 3 PHASE, 4 WIRE, 60HZ 42 120/208V, 3 PHASE, 4 WIRE, 50HZ 43 127/220V, 3 PHASE, 4 WIRE, 50HZ 72 400V, 3PH, 3W, 60Hz 73 400V, 3PH, 4W, 60Hz 90 240/416V, 3 PHASE, 4 WIRE, 60HZ 91 220/380V, 3 PHASE, 4 WIRE, 60HZ 92 220/380V, 3 PHASE, 4 WIRE, 50HZ 93 240/416V, 3 PHASE, 4 WIRE, 50HZ 94 400V, 3PH, 3W, 50Hz 95 400V, 3PH, 4W, 50Hz 96 416V, 3PH, 3W, 60HZ 97 380V, 3 PHASE, 3 WIRE, 60HZ 98 380V, 3PH, 3W, 50HZ 99 416V, 3PH, 3W, 50HZ None(Std) XXXXXXX Others TBD Example GTXDESSAS30 This number string shows the correct format for a GTX module that is 100Amps with 3 poles, utility to generator switching configuration, MX70 with an enclosure style IP20 (NEMA 1), that has a 240V, 3PH, 3W, 60HZ operating voltage. GE Critical Power 601 Shiloh Road Plano, TX USA 75074 Toll Free +1 877 546 3243 Direct +1 972 244 9288 www.gecriticalpower.com *Registered trademark of the General Electric Company. The GE brand, logo, and lumination are trademarks of the General Electric Company. 2015 General Electric Company. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. PB-GTXATS, Rev. 06/2015