Miniaturized Spectroradiometer

Similar documents
Spectroradiometer specbos 1201

Broadbandradiometer specbos 1211

JETI Specbos Instruments

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Achieving 100,000 : 1 contrast measurement

Chameleon Spectroradiometer

We bring quality to light. MAS 40 Mini-Array Spectrometer

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

LED Tester BTS256-LED

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

specification display & lighting hera spectrometer

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

GL spectis 1.0 Touch The world s first smart spectrometer.

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

JETI SCPI commands schematic and in examples

CS-2000/2000A. Spectroradiometer NEW

BTS2048-VL-CP-ILED-B-IS-1.0-HL

LED Lighting Flux and Color Measurement System (LFC)

We bring quality to light. CAS 140CT Array Spectrometer

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Luminous Flux (lumens) System LM-ISP-XXXX

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

Imaging Photometer and Colorimeter

Spectroradiometer series NEW

Instruction Manual of Luminance and Spectral Radiance Calibrations

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Gamma Scientific Display Measurement Systems

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

operating manual iliad for Windows & Mac OS X software application rc81

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

GL SPECTIS 1.0 Touch The world s first smart spectrometer

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

illumia Plus Temperature Controlled Light Measurement Systems

Application Note (A16)

MK350 Portable Spectrometer

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

SPECTRAL SCANNER. Recycling

We bring quality to light. CAS 120 CCD Array Spectrometer

PR-655 PR-670 PR-680 and PR-680L SpectraScan

Microscope-Spectrometer

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

Application Note (A19)

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

The Right Tool for a Spectrum of Applications

ILLUMINANCE METER LUMINANCE METER CHROMA METER T-10A /T-10MA/ T-10WSA/T-10WLA CL-200A CL-500A LS-100/LS-110 CS-100A CS-200

Solid State Luminance Standards

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometry for Traffic Engineers...

In sum the named factors cause differences for multicolor LEDs visible with the human eye, which can be compensated with color sensors.

Properties of LED considering museum lighting

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

specification light bulb cronus bhaskar spectrometer & colorimeter for light bulb measurements

Company synopsis. MSU series

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

VIDEO-COLORIMETRY MEASUREMENT OF CIE 1931 XYZ BY DIGITAL CAMERA

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration



High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

ILLUMINANCE METER T-10 Series

Photometry for Traffic Engineers...

Photometry and Light Measurement

Zenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!



Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

Novel Approach for LED Luminous Intensity Measurement

NVLAP LAB CODE:

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Illuminance Meter. series

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Ultimate and Versatile 2D Spectroradiometer is finally released!

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Development of 2 Total Spectral Radiant Flux Standards at NIST

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Transcription:

Miniaturized Spectroradiometer Thomas Morgenstern, Gudrun Bornhoeft, Steffen Goerlich JETI Technische Instrumente GmbH, Jena, Germany Abstract This paper describes the basics of spectroradiometric instruments as well as criteria for their choice. Special attention is turned to the recent development of miniaturized spectroradiometers which are suitable for use in quality control processes, even directly at the production line. The requirements for such instruments as well as their advantages and drawbacks are discussed. 1. Introduction New types of lamps, optical displays, signals and the design of indoor and outdoor illumination play a more and more increasing role in modern technology. Examples are LCD, plasma and LED screens, electroluminescent displays, fluorescent materials, LED illumination of airfields, LED traffic lights, Metal halide lamps etc. Fig. 1 Selection of measuring objects Therefore the need for appropriate light measurement instrumentation also increases. This concerns especially instruments, which are suitable for use in the production process. Such instruments have to have the following main properties: Sufficient measurement precision, small size, easy integration into the control system, simple handling, little amount of maintenance and recalibration and an economic price. They can be used for quality control even at assembly lines. Radiometric and colorimetric measurements can be done with two different set ups with filter instruments or with spectrometer based instruments. Filter instruments use three detectors with their sensitivities adapted to the three color receptors of the human eye. Advantages are fast measurements and high sensitivity, but they cannot resolve the detailed spectrum. Therefore they provide only a limited range of measuring values as integral luminance and chromaticity. Spectrometer based instruments (spectroradiometers) can deliver more information, e.g. spectral luminance, radiance and Color rendering indeces. If these values are of interest such instruments have to be used. In the past only laboratory spectroradiometer with well-engineered parameters and equipment were available. Compact miniaturized instruments are also on the market for a short time. JETI Technische Instrumente GmbH has developed such spectroradiometers fulfilling the requirements listed above [1].

2. Applications Fig. 2 shows spectra obtained from different light sources and measured with the new JETI spectroradiometer specbos 1200. Irradiance[W/(m²*nm)] 0,225 0,200 0,175 0,150 0,125 0,100 0,075 0,050 0,025 0,000 Wavelength [nm] Philips TLD 58W/965 Osram L58W21-840 Radiance[W/(sr*m²*nm)] 0,25 0,20 0,15 0,10 0,05 0,00 wavelength [nm] Radium NL 18W/11-830 Radium NL 18W/11-860 0,016 0,014 0,008 0,007 Irradiance[W/(m²*nm)] 0,012 0,010 0,008 0,006 0,004 iradiance [W/(m 2 *nm)] 0,006 0,005 0,004 0,003 0,002 0,002 0,001 0,000 wavelength [nm] Monitor Red 0,000 wavelength [nm] denní Daylight svetlo Fig. 2 Spectra of fluorescent lamps, a red CRT screen and daylight Radiometric and colorimetric measuring values can be obtained from these spectra by the classical calculation schemes. Such values are: Integral radiance, spectral and integral luminance Chromaticity x y and u v Dominant wavelength and color purity Color rendering index CRI Correlated color temperature CCT Examples for light sources which can be characterized by spectroradiometers are listed in the following table: Production CRT displays Flat panel displays (LCD, Plasma, Electroluminescent, OLED, ) Phosphors Metal Halide lamps Surgery illumination Discrete LED classification Digital projectors Research/ Monitoring/ Education Daylight measurement Traffic lights Room illumination Illumination in architecture models Practical courses Tab. 1 Applications of spectroradiometers - 2 -

3. Principle of Spectroradiometers The basic component of a spectroradiometer is the spectrograph. It determines the primary optical parameters of the instrument, e.g. wavelength range, optical resolution and measuring time. Fig. 3 Scheme of a spectroradiometer The main difference of a spectroradiometer to a standard spectrometer is the absolute intensity (y) axis of the spectrum. Standard spectrometers have normally only a calibrated wavelength (x) axis. The relation between the pixel numbers of the array and the real wavelengths is usually given in a polynomical equation up to the 4 th order. Additionally spectroradiometers have to be calibrated with a traceable standard lamp. The spectral sensitivity, which is calculated during this calibration procedure at the manufacturer, is used for the transformation of the measured raw data into the absolute spectrum. This calibration has to be repeated at least every two years to maintain the measurement precision. Furthermore the following extensions, compared to a standard spectrometer, are arranged to adapt the instrument to radiometric applications: - special measuring optics (see table 2 below) - mechanical shutter for dark signal compensation - calculation of radiometric and colorimetric values The instrument can be designed as a stand alone or as a PC based version. At present stand alone instruments mainly contain an alphanumeric display for the measuring results. An additional PC software gives the possibility to show the full spectrum, furthermore it is possible to manage the measuring results and to proceed special calculations. The following figure shows a typical radiometric software from JETI specbos 1200. There can be seen the spectrum as well as several colorimetric and light measuring values. - 3 -

Fig. 4 Sceenshot of a radiometric software The radiometric software of specbos 1200 has the following additional functions: storage of spectra and measuring values in Excel TM storage of reference spectra in GRAMS and ASCII formate basic mathematical operations for the spectra 4. Peculiarities of compact spectroradiometers The main aim in the development of compact spectroradiometers is to design a precise instrument, which has only the essential features for the measurement. This idea will be demonstrated considering specbos 1200 as example. The basic unit of specbos 1200 is a small spectrograph with a line array on a read out electronics. It is used the smallest array spectrometer of Jobin Yvon HORIBA (CP 20). The unit is fitted out with a fixed measuring optics generating a diverging field of view of 1.5. Fig. 5 Array spectrograph with driver electronics This basic set up can be used for the measurement of luminance and radiance data. The measuring area is not identified by a telescopic system (Pritchard mirror) as in laboratory instruments, but by a simple pilot laser circle on the object, which is projected during the adjustment phase. A mechanical shutter is used for the dark correction. The integration time is adapted automatically to the level of the light source under test. If illuminance and irradiance have to be measured, a diffuser cap used as cosine corrector can be attached to the measuring head. Furthermore the instrument can be attached to an integrating sphere for luminuous flux measurements. The radiometric calculations are proceeded on a PC, connected via USB interface. No extra power supply is needed. So the instrument can be used with a laptop for field measurements. - 4 -

There is also available another version, where the measuring data are provided directly by the instrument. It can be easily integrated to host computer systems in production facilities. The main advantages of specbos 1200 are its compactness and the easy handling. Furthermore it is much less costly than laboratory instruments. These advantages make it suitable for quality control in production, but also for usage in education, e.g. in light technical practical. Of course such compact instruments have not the same flexibility as laboratory instruments, e.g. no exchangeable or focusable optics and apertures and no detector cooling. Therefore some parameters, as the minimal detectable intensity or the minimal measuring area, are limited, compared with other spectroradiometers (see table 3 in paragraph 5). 5. Criteria for Instrument Choice In general spectroradiometers are designed for different applications. A main issue is the light measuring value, which is of interest. From the following table can be seen which value is used for the characterization of a specific measuring object. Tab. 2 Light measuring values for different applications - 5 -

Not every spectroradiometer is suited for all applications. Some instruments are only designed for luminance measurements, others include an additional front end (e.g. diffusor) for illuminance measurements and again others are dedicated for Luminous flux measurements (fitted out with integrating sphere). Another main criterion for the choice of a certain type of instrument are the attributes wavelength range, optical resolution, sensitivity and of course the price. The following table shows selected parameters for three instruments in comparison: Laboratory instruments Compact Instrument Parameter Photo Research PR-705 Minolta CS-1000 JETI specbos 1200 Spectral range 380 780 nm 380 780 nm 380 780 nm Standard lenses one, variable focus two, variable focus fixed, divergent Operation Stand alone or with PC Stand alone or with PC only with PC Optical resolution 2.5 20 nm 5 nm 9 nm (FWHM) Optical system Variable focus lens and 4 different lenses Aspherical lens, f=4 mm 4x fixed focus lenses Target finder system Eyepiece, through the lens (Pritchard), CCD camera and monitor option) Eyepiece, through the lens (Pritchard), monitor option Circle marking by internal pilot laser Acceptance angles 2 / 1 / 0.5 / 0.25 / 0.125 (1 and 0.25 with standard MS-55 lens, others extra costs) 1 (0.14 with special lens) Smallest target diameter 1 mm with 1 aperture, 7.9 mm (standard lens) at 36 cm Measurement modes Spectral radiance (irrad., Spectral radiance flux, intensity optional) Computed values Lowest luminance level, standard lens Measurement range luminance Lv, Le, 1931 CIE x,y, 1976 CIE u v, XYZ, CCT, delta Lv, delta xy, delta u v, delta CCT, L*u*v*, L*a*b*, delta E 0.1 cd/m2 @ 1 aperture, 1 cd/m2 @ 0.25 aperture 0.003 1700 cd/ m 2 @ 2, 0.16 110 000 cd/ m 2 @ 0.25 Lvxy, Lvuv, Lvu v, Tduv, Le, dom. Wl, purity (2 and 10 observer switchable) 1.5 < 0.25 cd/m2 2 cd/m 2 0.01. 80 000 cd/ m 2 (illum. A), 5 mm at 20 cm distance Spectral radiance, spectral irradiance (optional spectral luminous flux) Lv, Le, Ev, Ee, CIE x,y, u,v, CCT, dominant WL, color purity, CRI (all in PC software) 2 70 000 cd/m 2 Accuracy Luminance +/- 2 % to NIST @ 2856 K +/- 2 % +/- 1 digit +/- 5 % (@ 1000 cd/ m 2 ) (illum.a) Repeatability Chromaticity +/- 0.0005 @ 2856 K x, y 0.0002 (illum. A) +/- 0.0005 x,y Dimensions 233 mm x 124 mm x 163 mm 146 mm x 148 mm x 256 mm 150 mm x 58 mm x 34 mm Weight 5.6 kg 4.7 kg 300 g Price of basic unit (approx.) EUR 43 000 EUR 23 200 EUR 4 500 Tab. 3 Parameter comparison for different spectroradiometers - 6 -

Fig. 6 Laboratory (CS-1000 of Minolta) and compact (specbos 1200 of JETI) spectroradiometer An additional criterion is the volume and handling of the instrument, especially if the application is under production environmental conditions. In such cases small instruments as specbos 1200 are a good choice, because they can be handled like a sensor. They can be arranged directly at the production line, e.g. for individual inspection of metal halide lamps. 6. Summary The paper deals with the operation and parameters of spectroradiometers. Furthermore the criteria for the choice of a spectroradiometer type for a certain application are discussed. A new compact instrument using a miniaturized spectrograph is described. The small dimensions make it especially suitable for the quality control in production, and, in combination with a laptop, for field measurements. Additionally the instrument is interesting for applications in the educational sector due to its easy handling and economic price. Literature: [1] Web site www.jeti.com - 7 -