Optical laser distance sensors. Dimensioned drawing

Similar documents
Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing

Laser light scanner with background suppression. Dimensioned drawing

Throughbeam photoelectric sensors. Dimensioned drawing. Transmitter/receiver Optical axis LED yellow 90 turning connector. Electrical connection

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Leuze electronic. 3 Series. Product description

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Retro-reflective sensors for bottles and tape. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing. Electrical connection. see remarks!

Leuze electronic. Throughbeam photoelectric sensor. Dimensioned drawing. Electrical connection. Accessories: ISO 9001 IP 67

Electrical connection

Laser contrast scanner. Dimensioned drawing

Sensors for PET, glass and foil PRODUCT DESCRIPTION

Electrical connection

Diffuse reflection light scanner with background suppression. Dimensioned drawing

laser sensors through-beam sensor switching output / analog output high precision repeatability

5-step-switch for adjustment of sensitivity (switching threshold) LED (super-bright, yellow) for switching state indication.

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Retro-reflective sensors with polarizing filters, M18 housing

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

Contrast scanners detect the little differences

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

SI-JET Series SI-JET3-CON8 A-LAS-M C A-LAS-M C. Design. SI-JET Series Spray Jet Control Sensors. Product name:

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

D-LAS Series D-LAS2-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-(aperture)*-T

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

D-LAS Series D-LAS2-LC-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-LC-T.

Retro-reflective ultrasonic sensor. Dimensioned drawing

SPECTRO Series SPECTRO-3-FIO-UV-SL. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 8-11)

QL50 Luminescence Sensor

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**

MLV40 Series Miniature Sensors

QL55 Series Luminescence Sensor

WL 4-2 Photoelectric reflex switches, red light, dark-switching -- DC

SPECTRO Series SPECTRO-3-UV-SL. Design. SPECTRO-3 Series True Color Sensors. Product name:

MLV12 Series Dura-Vue TM Sensors

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

V 18 Laser No frills performance: long ranges, high speeds with precision

INTRODUCTION 提夫自控技术 ( 上海 ) 有限公司 LAS laser sensors cover measurement ranges from 1 to mm. The integrated micro-controller delivers an accur

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

V 12-2 Miniature photoelectric switches: innovations in M12 housings

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Ultramini clever reliability in confined quarters. Simple installation and operation

Inductive switches. Dimensioned drawing

DS500/DT500 Laser sensor measures distances to 30 m on black material in proximity mode

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

WT190T: The convenient, reliable proximity switch precisely the right one for challenging applications

Inductive switches. Dimensioned drawing

Parallel Beam Linear Sensor

SPECTRO Series SPECTRO COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

Pulse Scaler for DIN Rail Attachment

Example: ZX-BGS-DS300P-2M ZX Series - Diffuse Background Suppression Type - Distance Settable, 300mm Sensing Distance, PNP - 2m Cable

M18 DC Photoelectric Switches FA

Distance sensors. System description. Distance measurement using triangulation

Smart Power Relay E I...

M70LL Laser Distance Sensor

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

INPROX sensors. displacement MLS compact ccd-laser distance sensor

Luminescence Sensors. Operating Instruction

LASER. Analog Laser Displacement Transducer. LAS Series. Key-Features:

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Type CP-S, CP-C & CP-A Switch mode

W 2: Sub-Miniature Photoelectric Switch Range: Super-Small and Powerful

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Distance sensors. System description. Distance measurement using triangulation

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Absolute encoders - SSI Shaft with clamping or synchro flange Optical multiturn encoders 14 bit ST / 12 bit MT

SPECTRO Series SPECTRO-3-30-POL. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p )

V 18 Laser No frills performance: long ranges, high speeds with precision

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Sturdy aluminium housing, anodized in blue. Connection

Operating instructions Measured signal converter for temperature sensors TP / / 2010

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

Laser diffuse reflection sensor with background suppression. Dimensioned drawing

Electrical connection

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

CS Colour sensors: When it s the colour that counts

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

Contrast Sensors. SICK The pioneer in contrast sensors for more than 60 years

Technical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv

Operating instructions. PosCon OXE7 Edge measurement in a new dimension.

W 23-2: Focussing on what is essential and economic

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

W 250: Compact photoelectric switch series for a broad range of applications

Technical data. General specifications. Measurement range min max. 360

Online data sheet NT NT8 CONTRAST SENSORS

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Analogue temperature controllers

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance measurement

PHOTOELECTRIC SENSORS. Online data sheet

Operating instructions Contrast sensor O5K / / 2016

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Transcription:

Dimensioned drawing en 02-2012/11 50112361 150 800mm 10-30 V DC We reserve the right to make changes DS_ODSL96BS800_en_50112361.fm Small laser light spot for measurements on small, structured or metallic objects Reflection-independent distance information Highly insensitive to extraneous light PC/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Configurable measurement mode Configurable measurement data preprocessing and filter IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) Configuration software A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) 150 800mm Resolution 2) 0.1 0.8mm Light source laser Wavelength 655nm (visible red light) Light spot approx. 1x1mm² at 800mm Laser warning notice see remarks Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±1.5% Repeatability 3) ±0.5% b/w detect. thresholds (6 90% rem.) 1% Temperature compensation yes 4) Timing Measurement time 1 5 ms 1) Response time 1) 15ms Delay before start-up 300ms Electrical data Operating voltage U B C6/V6 18 30VDC (incl. residual ripple) D26/D36 10 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 5), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analog output V6 voltage 1 10V, R L 2k C6 current 4 20mA, R L 500 Serial interface D26/D36 RS 232/RS 485, 9600 57600Bd, 1 start bit, 8 data bits, 1 stop bit, no parity Transmission protocol 14 bit, 16 bit, ASCII, Remote Control Indicators teach-in on GND teach-in on +U B Green LED continuous light ready flashing fault teaching procedure no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teaching procedure object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67, IP 69K 8) Laser class 2 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Reflectivity 6% 90%, complete measurement range, at 20 C, medium range U B, measurement object 50x50mm², depending on the measurement transmission type and the baud rate 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) The push-pull switching outputs must not be connected in parallel 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC, with cover closed 8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test. Order guide Designation Part No. RS 232 interface ODSL 96B M/D26.S-800-S12 50111035 RS 485 interface ODSL 96B M/D36.S-800-S12 50112065 Analogue current output ODSL 96B M/C6.S-800-S12 50106728 Analogue voltage output ODSL 96B M/V6.S-800-S12 50106729 Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose: The ODSL 96B distance sensors are optoelectronic sensors for the optical, contactless measurement of the distance to objects. This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons.

Analog output: characteristic curve for factory setting A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Serial output: transmission protocol for factory setting 9600Bd, 1 start bit, 8 data bits, 1 stop bit, transmission protocol ASCII measurement values Transmission format: MMMMM<CR> MMMMM = 5-digit measurement value in mm (resolution 1mm) <CR> = ASCII character "Carriage Return" (x0d) Further information about available transmission protocols may be found in the technical description "Optical distance sensors ODSL9/ODS96B".

Dimensioned drawing en 01-2013/06 50122746 150 1500mm 18-30 V DC We reserve the right to make changes DS_ODSL96BMCV6C1S1500_en_50122746.fm Reflection-independent distance information Red light laser diode with laser class 1 Analog current or voltage output PC/OLED display and membrane keyboard for configuration Measurement value display in mm on OLED display Configurable measurement range and measure mode Teachable switching output and analog output IEC 60947... IEC 60947... Accessories: (available separately) Mounting systems Cable with M12 connector (K-D ) Configuration software IP 69K IP 67 A Green indicator diode B Yellow indicator diode C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and membrane keyboard I Reference edge for the measurement (cover glass) Electrical connection

Specifications Optical data Measurement range 1) 150 1500mm Resolution 2) 0.1 2mm Light source laser Wavelength 655nm (visible red light) Light spot approx. 1x1mm² at 800mm Max. output power 0.6mW Pulse duration 22ms Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±1.5% Repeatability 3) ±0.5% B/W detection thresh. (6 90% rem.) 1% Temperature compensation yes 4) Timing Measurement time 12 60ms 1) 5) Response time 1) 180ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 6), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analog output voltage 1 10V, R L 2k current 4 20mA, R L 500 Indicators Teach-in on GND Teach-in on +U B Green LED continuous light ready flashing fault teach event no voltage Yellow LED continuous light object inside teach-in measurement distance flashing teach event object outside teach-in measurement distance Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C/-30 C +70 C Protective circuit 7) 1, 2, 3 VDE safety class 8) II, all-insulated Protection class IP 67, IP 69K 9) Laser class 1 (in accordance with EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, complete measurement range, at 20 C, medium range of U B, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) Typ. ± 0.02 %/K 5) Measurement time in factory setting (ambient light measure mode), operation in other measure modes is not recommended 6) The push-pull switching outputs must not be connected in parallel 7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 8) Rating voltage 250VAC, with cover closed 9) IP 69K test in accordance with DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Remarks Measurement time depends on the reflectivity of the measurement object and on the measurement mode. Approved purpose This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Order guide Designation Part no. With M12 connector Current output ODSL 96B M/C6.C1S-1500-S12 50123687 Voltage output ODSL 96B M/V6.C1S-1500-S12 50123686