Keysight Technologies Solid State Switches. Application Note

Similar documents
Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies USB Preamplifiers

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies U9400A/C Solid State FET Transfer Switches

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies N4985A System Amplifiers

Keysight Technologies Power of Impedance Analyzer

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight U9397A/C FET Solid State Switches (SPDT)

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies Waveguide Power Sensors. Data Sheet

Introduction. Part 1. Introduction...2

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight N9310A RF Signal Generator

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies HMMC-3002 DC-16 GHz GaAs HBT MMIC Divide-by-2 Prescaler

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Technologies HMMC-3008 DC-16 GHz GaAs HBT MMIC Divide-by-8 Prescaler

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Automotive ECU Transient Testing Using Captured Power System Waveforms. Application Note

Keysight Technologies Alliance for Wireless Power (A4WP) Measurements Using an Oscilloscope (Part 3)

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies Isolating Problems and Optimizing Wireless Designs with Digital Demodulation and EVM

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Keysight Technologies PXI Programmable Step Attenuator Module

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies Photodiode Test Using the Keysight B2980A Series

Keysight Technologies Characterizing Random Noise in CMOS Image Sensors

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Transcription:

Keysight Technologies Solid State Switches Application Note

Introduction Selecting the right switch technology for your application RF and microwave switches are used extensively in microwave systems for signal routing between instruments and devices under test (DUT). Incorporating a switch into a switch matrix system lets you route signals from multiple instruments to single or multiple DUTs. This enables multiple tests to be performed with the same setup, eliminating the need for frequent connect and disconnects. The entire testing process can then be automated increasing throughput in a high volume production environment. Abstract Selecting the right switch technology (in terms of RF performance, reliability, switching time, power handling, etc.) to accessorize and/or complement your system set-up requires an investment of time and resources. This application note will not only enhance your core knowledge of the various switch technologies, but will also provide a selection of products currently offered by Keysight Technologies, Inc. to serve as a platform of comparisons for the technologies explained. The two mainstream switch technologies in use today, namely solid state and electro-mechanical (EM), will be discussed. The primary focus will be on the theory of operation, coupled with detailed explanation on some of the typical performance details.

Types of Switches Before selecting a switch, it is important to understand the fundamental differences between switches. There are two major types of connectorized RF and microwave switch modules: a) Electro-mechanical switches. They rely on mechanical contacts as their switching mechanism. b) Solid state switches. There are two main types of solid state switches: field-effect transistors (FETs) and PIN diodes. FET switches create a channel (depletion layer) that allows the current to flow from the drain to the source of the FET. The PIN diode consists of a high resistivity intrinsic (I) layer sandwiched between highly doped positively (P) charged material and negatively (N) charged material. Solid State Switch Overview FETs and PIN diodes have long been used for switching applications. A brief overview of their characteristics will be helpful in understanding how switches operate. Using FETs for switching Source R ( on) V > 0 volts Gate Drain n + GaAs n-type GaAs Depletion layer Channel Semi-insulating GaAs substrate a) Low channel resistance (maximum cross-section) R (off) Source n + n-type GaAs Semi-insulating GaAs substrate V < V p Gate Depletion layer No Channel Drain b) High channel resistance (punch-through) Figure 1. On and Off states in a field-effect transistor 3

Using FETs for switching (continued) FET switches are very stable and repeatable due to good control of the drainto-source resistance (RDS). Figure 1(a) shows the low channel resistance (RDS = RON) which allows these switches to operate at low frequencies (down to DC). In the off state, as shown in Figure 1(b), the conduction channel is depleted (pinched off), which causes the FET to exhibit very high resistance (ROFF). This mechanism ensures that FETs provide excellent isolation at low frequencies. The isolation of FET degrades at higher frequencies due to the effect of drain-to-source capacitance (CDS). Figure 2 shows a GaAs MESFET schematic, with Equation 1 showing the drain-to-source impedance as equal to 320 Ω at 10 GHz. This is equivalent to an isolation of 10.5 db between the drain and the source. Therefore, FET switches do not have good isolation at high frequencies. D G C DS = 0.05 pf S Figure 2. GaAs MESFET schematic Equation 1 Using PIN diodes for switching P N Metal pin Glass Intrinsic layer L R s C T Rp (a) Cross selection of basic diode (b) Forward bias (c) Reverse bias Figure 3. PIN diode equivalent circuits PIN diodes are another mainstream switching technology. The PIN diode structure consists of an intrinsic (I) layer with very high resistivity material sandwiched between regions of highly doped positively (P) charged and negatively (N) charged material as shown in Figure 3(a). 4

Using PIN diodes for switching (continued) When the PIN diode is forward biased, positive charges from the P region and negative charges from the N region are injected into the I-layer increasing its conductivity and lowering its resistance. Figure 3(b) shows the equivalent circuit with the PIN diode forward biased. L is the parasitic inductance and RS is the series resistance, approximately 1 depending on the biasing applied and the PIN diode structure. With reverse or zero biasing, the I layer is depleted of charges and the PIN diode exhibits very high resistance (R P ) as shown in Figure 3(c). CT is the total capacitance of the PIN diode which is the sum of the diode junction capacitance (C J0 ) and the parasitic capacitance (C P ). Capacitance limits switch performance at high frequencies in the form of isolation roll-off and increased insertion loss. A low capacitance diode may help improve performance at higher frequencies. The most important feature of the PIN diode is its basic property as an almost pure resistor at RF and microwave frequencies. Its resistance value varies from 10 KΩ to less than 1 Ω depending on the amount of current flowing through it. Two key PIN diode characteristics are: The lowest operating frequency of PIN diode is given by Equation 2. The PIN diode will behave like a PN diode if it operates below this frequency. The RF signal will be rectified by the diode. Equation 2 where equals the minority carrier life time The PIN diode impedance (forward bias) at RF and microwave frequencies depends primarily on DC forward bias, not on the RF or microwave signal. Hybrid switches It is clear that both PIN diodes and FETs provide distinctive advantages. However, neither exhibit superior bandwidth and isolation requirements at the same time. So, hybrid switches using FET and PIN diode technology were created to provide wide bandwidth and high RF performance switching. The theory of operation of hybrid switches is summarized below. Hybrid switches use: Series FETs to extend the frequency response down to DC. (Series FETs provide excellent low frequency isolation.) Shunt PIN diodes at λ/4 spacing to provide good isolation performance at the high-end frequencies. The utilization of series FETs instead of PIN diodes also provides better repeatability performance because the R DS ON is well controlled. 5

Switch Selection It is important to know how to select the right switch for your application. This section provides useful guidelines for this purpose. Table 1 shows the key performance comparison of electro-mechanical versus solid state switches. Table 1. Mechanical and solid state switch performance comparison (typical) Table 1. Mechanical and solid state switch performance comparison (typical) Solid state Switch type Frequency range Electromechanical (FET) (PIN) (Hybrid) from DC from DC from MHz from khz Insertion loss low high medium high Isolation good across all frequencies good at lowend frequencies good at highend frequencies Return loss good good good good good at high-end frequencies Repeatability good excellent excellent excellent Switching speed slow fast fast fast Power handling high low low low Operating life medium high high high ESD immunity high low medium low Sensitive to vibration RF power overstress, temperature RF power overstress, temperature RF power overstress, temperature Table 2 shows the performance comparison of Keysight electro-mechanical and solid state switches. The key parameters and typical performances will be discussed in the following sections. Table 2. Mechanical and solid state switch performance comparison (typical) Switch type Electromechanical N1810TL Solid state (hybrid) U9397C Solid state (PIN) 85331B Frequency range DC 26.5 GHz 300 khz 18 GHz 45 MHz 50 GHz Insertion loss < 0.6 db < 6.5 db < 15.5 db Isolation 120 db @ 26.5 GHz 100 db @ 8 GHz 100 db @ 0.5 GHz Switching speed 10 50 ms < 350 µs < 1 µs Power handling 30 W @ 4 GHz (cold switching) 0.8 W @ 8 GHz 0.5 W Operating life > 5 million cycles infinite infinite 6

Insertion loss Insertion loss plays an important role in many applications. In receiver applications, the effective sensitivity of the system is reduced by the amount of insertion loss. In system applications where the additional power needed to compensate for the loss (e.g. using amplifiers) may not be readily available, possibly due to cost or space constraints, low insertion loss will be the crucial element. Different switch technologies exhibit different insertion loss performance. Electro-mechanical switches, which have the lowest loss (up to 26.5 GHz), are suitable for these types of applications. Refer to Figure 4. 0-2 0 10 20 30 40 50-4 -6 db -8-10 -12-14 GHz N1810TL 26.5 GHz electro-mechanical switch U9397C 18 GHz solid state switch (hybrid) 85331B 50 GHz solid state (PIN) Figure 4. Electro-mechanical versus solid state switch insertion loss (typical) 7

Isolation High isolation in switches is crucial in most measurement applications. Good isolation prevents stray signals from leaking into the desired signal path. In other words, an unwanted signal needs to be attenuated before it has an opportunity to reach a particular test port. High isolation is especially crucial in measurement systems where signals are consistently being routed to and from a variety of sources and receivers through various switch test ports. If these stray signals are allowed to filter through, measurement integrity is severely compromised. Figure 5 shows that the Keysight N1810TL electro-mechanical switch provides the best isolation performance (typically greater than 120 db from DC to 26.5 GHz) compared to the solid state switches. The 85331B 50 GHz solid state (PIN) switch provides excellent isolation performance from 4 to 50 GHz, whereas the U9397C 18 GHz solid state (hybrid) switch offers typically > 100 db of isolation up to 6 GHz. 0-20 0 10 20 30 40 50 db -40-60 -80-100 -120-140 -160-180 GHz N1810TL 26.5 GHz electro-mechanical switch U9397C 18 GHz solid state switch (hybrid) 85331B 50 GHz solid state (PIN) Figure 5. Electro-mechanical versus solid state switch isolation (typical) 8

Switching speed The measurement of switching speed is based on 10% to 90% RF, using a high speed generator and an oscilloscope. Switching speed has been and will continue to be one of the main strengths of GaAs FET switches. With ideal driver circuits, GaAs FET IC switches have been shown to to switch within < 1 ns (die level). Looking into the future, the emergence of InGaAs material is expected to push the switching speed well into the sub-nanosecond region. Fast switching speed is important in ATE industries where product (testing) through-put is of paramount importance. It is especially important in applications that require the stacking of multiple switches in series. Another new technology usage is in the automotive industry, namely for Adaptive Cruise Control (ACC) and Collision Avoidance Systems (CAS), where high-frequency transmitting and receiving switching rates need to be thoroughly analyzed. As can be seen from Table 2 on page 6, the switching time for U9397C 18 GHz solid state (hybrid) switch is the fastest, followed by the 85331B 50 GHz solid state (PIN) switch and N1810TL 26.5 GHz electro-mechanical switch, respectively. Operating life The switch operating life is specified as the minimum number of cycles (the number of times it switches from one position to another and back) before the switch starts to fail (i.e. where it no longer performs up to the minimum specifications). Switch operating life is crucial when the switch is being integrated into test and measurement instruments or systems which require thousands of switching cycles for a single round of measurements. In this context, solid state switches would be the preferred choice. Other key parameters Besides the four key parameters discussed above, there are a few other aspects that need to be considered in the switch selection process. Electro-mechanical switches are sensitive to vibration due to a switching mechanism that relies solely on mechanical contacts. On the other hand, solid state switches are sensitive to RF overstress and temperature due to the limitation of the solidstate devices. In addition, solid state FET switch ICs are very sensitive to ESD, in comparison to their electro-mechanical counterparts. Conclusion This application note illustrated the multiple aspects of the various switch technologies and their respective usage. The selection guide and switch overview sections have been specially tailored to assist you in selecting the right Keysight switch to optimize test performance and throughput for your applications. 9

10 Keysight Solid State Switches - Application Note Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) www.keysight.com/find/mta DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, December 2, 2017 5989-5189EN www.keysight.com