Arc Sensor User Manual

Similar documents
MN026004EN. EAFR-101 Arc Point Sensor Relay User Manual

MN026005EN. EAFR-101S Arc Point Sensor Relay User Manual

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

COOPER POWER SERIES. Upgrade instructions for CL-6 series control firmware. Voltage Regulators MN225071EN

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

MN E. Waveform Viewer: Power Xpert Software 2.2

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

Effective November 2017 Supersedes May 2017

INSTRUCTION LEAFLET IL17537B F FRAME IQ ENERGY SENTINEL TM INSTALLATION INSTRUCTIONS FOR F FRAME IQ ENERGY SENTINEL TM

A1800 ALPHA meter special installation instructions DANGER

COOPER POWER SERIES. Slip-On bushing current transformer kits KA712L1S, KA712L2S, KA712L3S, and KA712L5S installation instructions and technical data

4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Planning and Installing the EnergyAxis System Starter Kit. Introduction. Related Documents

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Fiber Optic Expansion Interface

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

WSA 8 BOX RELE Installation Manual

UM Slim proximity touch sensor demo board OM Document information

60 V, N-channel Trench MOSFET

Contents. Warranty and Disclaimer 2 Introduction 3

PMZB350UPE. 1. Product profile. 20 V, single P-channel Trench MOSFET 1 August 2012 Product data sheet. 1.1 General description

Logic level compatible Very fast switching Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM

Relay driver High-speed line driver Level shifter Power management in battery-driven portables

NX3020NAK. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

20 V, 2 A P-channel Trench MOSFET

75 MHz, 30 db gain reverse amplifier

NX3008PBKMB. 30 V, single P-channel Trench MOSFET

PMXB360ENEA. Relay driver Power management in automotive and industrial applications LED driver DC-to-DC converter

NX7002AK. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

60 V, 320 ma N-channel Trench MOSFET

LX Series Part-Sensing Light Screen

Relay driver Power management in automotive and industrial applications LED driver DC-to-DC converter

20 V, single P-channel Trench MOSFET

OPERATION MANUAL LDM-1000

PMZ950UPEL. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

Trench MOSFET technology Low threshold voltage Enhanced power dissipation capability of 1200 mw ElectroStatic Discharge (ESD) protection: 2 kv HBM

50 V, 160 ma dual P-channel Trench MOSFET

20 V dual P-channel Trench MOSFET

Low threshold voltage Very fast switching Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM

60 V, 340 ma dual N-channel Trench MOSFET

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

PMZ550UNE. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

60 V, 310 ma N-channel Trench MOSFET

3M Power Clamp Wiremount Connectors

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

PMV50UPE. 1. Product profile. 20 V, single P-channel Trench MOSFET 20 July 2012 Product data sheet. 1.1 General description. 1.2 Features and benefits

40 V N-channel Trench MOSFET

30 V, 230 ma P-channel Trench MOSFET

Trench MOSFET technology Low threshold voltage Very fast switching Enhanced power dissipation capability: P tot = 1000 mw

BSS138AKA. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

TABLE OF CONTENTS. Sliver Cable Assemblies. TE Connectivity Technical Datasheet

Logic level compatible Very fast switching Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM

20 V, 800 ma dual N-channel Trench MOSFET

Sheet Metal Design Guidelines

20 V, P-channel Trench MOSFET

...Your environment is our business

Broadband Current Probe Series Operation Manual

AN Replacing HMC625 by NXP BGA7204. Document information

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

PMGD290UCEA. 1. General description. 2. Features and benefits. 3. Applications. Quick reference data

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Charging switch for portable devices DC-to-DC converters Power management in battery-driven portables Hard disk and computing power management

PMPB27EP. 1. Product profile. 30 V, single P-channel Trench MOSFET 10 September 2012 Product data sheet. 1.1 General description

Low power DC-to-DC converters Load switching Battery management Battery powered portable equipment

Interfacing Virtex-6 FPGAs with 3.3V I/O Standards Author: Austin Tavares

Flat Sample Holder Part Number

DATA SHEET. BGE MHz, 17 db gain push-pull amplifier DISCRETE SEMICONDUCTORS. Product specification Supersedes data of 1999 Mar 30.

UM User manual for di2c demo board. Document information

LED Series Sealed High-Intensity Area Lights

DATA SHEET. BGY MHz, 21.5 db gain push-pull amplifier Nov 15. Product specification Supersedes data of 1999 Mar 30. book, halfpage M3D252

Wireless 900 MHz Receiver

Analog Rectilinear Displacement Sensor

SSI-4 PLUS User Manual

8 Channel, DMX to 0 10 volt, Decoder board

PTN5100 PCB layout guidelines

Low threshold voltage Ultra small package: mm Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM

Specification for Lightning Sensor

DATA SHEET. BGY MHz, 15 db gain push-pull amplifier DISCRETE SEMICONDUCTORS. Product specification Supersedes data of 1997 Apr 14.

PMV250EPEA. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

The I-2532 CAN to Fiber Converter

DATA SHEET. BGY1085A 1000 MHz, 18.5 db gain push-pull amplifier DISCRETE SEMICONDUCTORS. Product specification Supersedes data of 1997 Apr 15

Broadband Current Probe Series Operation Manual

Logic level compatible Very fast switching Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM AEC-Q101 qualified

Z-5652 plus Series. 2D Image Hands-Free Scanner

Broadband LDMOS driver transistor. A 5 W LDMOS power transistor for broadcast and industrial applications in the HF to 2500 MHz band.

USER MANUAL Table of Contents

Logic level compatible Very fast switching Trench MOSFET technology ElectroStatic Discharge (ESD) protection > 2 kv HBM AEC-Q101 qualified

Taurus CP-300 Single Pump

Advanced Test Equipment Rentals ATEC (2832)

R_ Driving LPC1500 with EPSON Crystals. Rev October Document information. Keywords Abstract

E3X-DRT21/SRT21/CIF11

Transcription:

MN026008EN Arc Sensor User Manual EAFR-01 EAFR-06 EAFR-08 EAFR-07

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

MN026008EN Contents 1. ARC SENSORS...1 1.1 Arc Light Point Sensor Group: EAFR-01-A, EAFR-01-B, and EAFR-01-C...1 1.2 Arc Light Fiber Optic Loop Sensor (Plastic) EAFR-06...2 1.3 Arc Light Fiber Optic Loop Sensor (Glass) EAFR-07...3 1.4 Arc Light Fiber Optic Loop Sensor (High Temperature) EAFR-08...3 1.5 Sensor Type Dependencies...4 2. SENSOR CONNECTION... 4 2.1 Arc Light Point Sensor EAFR-01 Connection..............................4 3. ORDERING CODES... 7 iii

MN026008EN iv

1. Arc Sensors 1. Arc Sensors This manual describes only the EAFR-0x series sensors for Eaton arc flash relays arc protection system. It is important to read through instruction manuals of Eaton arc flash relays. The Eaton arc flash relays (EAFR) series provides the choice of different types of arc sensors to be utilized in different units and different switchgear types according to specific application requirements. Available sensor types are arc light point sensors and arc light fiber optic loop sensors. Arc light point sensors are typically installed in metal clad compartments providing quick, accurate location of the faulted area. Arc light fiber loop sensors are typically installed to cover a wider protected area with one fiber when no need for more exact fault locations exists. Figure 2. EAFR-01 Point Sensor Mounted to the Compartment Wall. 1.1 Arc Light Point Sensor Group: EAFR-01-A, EAFR-01-B, and EAFR-01-C The EAFR-01 arc light point sensors have a light sensitive photodiode element activated by receiving arc light. The EAFR-01 arc sensors should be mounted in the switchgear cubicles in such a way that the light sensitive part can receive light from the protected area. Typically, one sensor per closed metal clad compartment is used. In open spaces, such as the bus bar section, arc sensors should be mounted at a maximum of two meters (6.56 ft) apart. The fixed light sensitivity of the EAFR-01-A sensor is 8,000 Lux, the EAFR-01-B sensor is 25,000 Lux and the EAFR-01-C sensor is 50,000 Lux. The sensor does not require user settings. The point sensor s light detection radius is 180 degrees. Figure 1. Arc Point Sensor EAFR-01. The same screw pattern is utilized in a through the wall mounting arrangement. In this arrangement, the unit is turned around and the point of the photodiode sensor protrudes through a small hole cut in the wall. The point of the sensor now faces the compartment to be protected. This allows for the body of the sensor and cabling to be located outside the compartment (see Figure 3). For both types of installation, two screws are attached from the back side of the sensor. No external mounting plates are needed in any case. 1.1.1 EAFR-01 Installation and Wiring The EAFR-01 point sensors can be installed either on or through the compartment wall. An example of on the wall mounting is seen in Figure 2. The EAFR-01 sensor is fixed against the wall using two screws. 1

1. Arc Sensors Table 1. Suggested 100 Ω Compatible Shielded, Twisted Pair Cables. Manufacturer Part No. Atten. db/100' @ 1 MHz Data AWG Cable Diameter mm (in.) Temp. Rating C ( F) Voltage Rating Belden 3074F 0.34 18 11.68 (0.46) -40/+75 (-40/+167) Belden 9841 0.60 24 5.89 (0.23) -30/+80 (-22/+176) Belden 89841 0.60 24 5.13 (0.20) -70/+200 (-94/+392) 600 V 300 V 300 V Figure 3. EAFR-01 Point Sensor Mounted Outside Compartment. The cable to be used for wiring to the sensor should be a shielded, twisted pair cable. Table 1 lists several cables that can be used. Equivalent cable styles are acceptable to be used for the dielectric and temperature requirements of the application. Cable connectors are located beneath the covers on each end of the EAFR-01 sensors. The covers can be conveniently detached for fastening the sensor wires. Reattach the covers after installing the wires. Cable connectors are located at both ends of the sensor for series connecting a maximum of three sensors in one line (see Figure 4). 1.1.2 EAFR-01 Point Sensor Technical Data Table 2. Technical Data for the EAFR-01 Group of Point Sensors. Light Intensity Threshold Detection Radius Mechanical Protection IP 64 Sensor Wiring Arrangement Sensor Cable Specification Maximum Sensor Cable Length per Sensor Channel Operating Temperature 8,000 Lux/25,000 Lux/50,000 Lux 180 Degrees Two Wires and Shield Shielded Twisted Pair 0.75 mm2 (0.03 in.2) 200 m (656.2 ft) -20 to 85 C (-4 to 185 F) 1.2 Arc Light Fiber Optic Loop Sensor (Plastic) EAFR-06 The EAFR-06 is an arc light fiber optic loop sensor. The EAFR-06 fiber is a plastic fiber optic cable. EAFR-06 arc light fiber optic loop sensors can be ordered in pre-manufactured lengths of 10, 15, 20, 25, 30, 35, 40 m (32.81, 49.21, 65.62, 82.02, 98.43, 114.83, 131.23 ft). The EAFR-06 loop sensor fiber optic cable should be distributed throughout the protected switchgear cells. The EAFR-06 is not recommended to be cut and/or spliced on site. If accidental breakage of the loop sensor occurs, Eaton recommends replacing the loop sensor. Contact your nearest Eaton representative for more information. The fixed light sensitivity of the EAFR-06 sensor is 8,000 Lux. The sensor does not require user settings. The loop sensor s detection radius is 360 degrees (see Figure 4). 2

1. Arc Sensors Figure 4. EAFR-06 Arc Light Fiber Optic Loop Sensor (Plastic). Figure 5. EAFR-07 Arc Light Fiber Optic Loop Sensor (Glass). Table 4. Technical Data for the EAFR-07 Arc Light Fiber Optic Loop Sensor (Glass). Table 3. Technical Data for the EAFR-06 Arc Light Fiber Optic Loop Sensor (Plastic). Light Intensity Threshold Detection Radius Maximum Length Diameter Bending Radius Operating temperature 8,000 Lux 360 Degrees 40 m (131.23 ft) 1 mm (0.039 in.) 5 cm (2 in.) -10 to 85 C (14 to 185 F) 1.3 Arc Light Fiber Optic Loop Sensor (Glass) EAFR-07 The EAFR-07 is an arc light fiber optic loop sensor. The EAFR-07 fiber is a robust fiber optic cable providing practically unlimited bending radius. EAFR-07 contains hundreds of glass fiber drains covered by a plastic tube making it extremely strong. The EAFR-07 sensors can be ordered in pre-manufactured lengths of 10, 15, 20, 25, 30, 35, 40, 45, 50 m (32.81, 49.21, 65.62, 82.02, 98.43, 114.83, 131.23, 147.64, 164.04 ft). The EAFR-07 loop sensor fiber optic cable should be distributed throughout the protected switchgear cells. The EAFR-07 is not recommended to be cut and/or spliced on site. If accidental breakage of the loop sensor occurs, Eaton recommends replacing the loop sensor. Contact your nearest Eaton representative for more information. The fixed light sensitivity of the EAFR-07 sensor is 8,000 Lux. The sensor does not require user settings. The loop sensor s detection radius is 360 degrees (see Figure 5). Light Intensity Threshold Detection Radius Maximum Length Diameter Bending Radius Operating Temperature 8,000 Lux 360 Degrees 50 m (164 ft) 1.2 mm (0.047 in.) 1 cm (0.394 in.) -40 to 85 C (-40 to 185 F) 1.4 Arc Light Fiber Optic Loop Sensor (High Temperature) EAFR-08 The EAFR-08 is an arc light fiber optic loop sensor used for high temperature applications. It is developed to withstand temperatures of up to 125 C (257 F) and is therefore suitable for installation in wind turbine windings. The EAFR-08 fiber is a robust fiber optic cable providing practically unlimited bending radius. The EAFR-08 contains hundreds of glass fiber drains covered by a plastic tube making it extremely strong. EAFR-08 loop sensors can be ordered in premanufactured lengths of 10, 15, 20, 25, 30, 35, 40, 45, 50 m (32.81, 49.21, 65.62, 82.02, 98.43, 114.83, 131.23, 147.64, 164.04 ft) The EAFR-08 loop sensor fiber optic cable should be distributed throughout the protected switchgear cells. The EAFR-08 is not recommended to be cut and/or spliced on site. If accidental breakage of the loop sensor occurs, Eaton recommends replacing the loop sensor. Contact your nearest Eaton representative for more information. The fixed light sensitivity of the EAFR-08 loop sensor is 8,000 Lux. The sensor does not require user settings. The loop sensor s detection radius is 360 degrees (see Figure 6). 3

2. Sensor Connection Figure 6. EAFR-08 Arc Light Fiber Optic Loop Sensor (High Temperature). 2. Sensor Connection 2.1 Arc Light Point Sensor EAFR-01 Connection 1. Open the sensor side covers and then detach the pluggable connectors from the sensor PCB. Prepare the three twisted shielded pair cable connection (see Figure 7). NNote: There is no In or Out end of the cable. Either end of the cable can be used. Figure 7. Sensor Side Covers Removed and Pluggable Connectors Detached. Table 5. Technical Data for the EAFR-08 Arc Light Fiber Optic Loop Sensor (High Temperature). Light Intensity Threshold Detection radius Maximum Length Diameter Bending Radius Operating Temperature NNote: 8,000 Lux 360 Degrees 50 m (164 ft) 1.2 mm (0.047 in.) 1 cm (0.394 in.) -40 to 125 C (-40 to 257 F) If any of the EAFR-06, 07, 08 loop sensor ends need to be covered to avoid light detection from outside the protected zone, consult your nearest Eaton representative for more information. 2. Before connecting the cable to the connector, make sure that the connecting order is correct (+, signal, shield). The appropriate pin information is shown on the bottom shell of the sensor. Plug the wires into the connector and fasten them by using a screw driver (see Figure 8). Figure 8. Location of the PIN Information and Securing the Cable. 1.5 Sensor Type Dependencies Different sensor types can be utilized in different arc flash protection relays of the EAFR series. Table 6 describes the dependencies. Table 6. EAFR Series Relays and Arc Sensor Dependencies. EAFR-01 Point Sensor EAFR-06 Plastic Loop Sensor EAFR-01 Glass Loop Sensor EAFR-101 Yes No No No EAFR-102 No Yes Yes Yes EAFR-110P Yes No No No EAFR-110F No Yes Yes Yes EAFR-01 High Temperature Loop Sensor 3. Connect the other end of the cable to a sensor channel on EAFR-101 or EAFR-110P relay (see Figure 9). 4

2. Sensor Connection Figure 9. Sensor Cable Connected to a Sensor Channel on the Back of the Relay. 6. After connecting the sensor to the relay, the ERROR LED turns on, and the appropriate sensor channel LED starts to blink (e.g. S1 LED) (see Figure 12). The LEDs will blink to indicate that there is a new connection that has been made and the system auto-configuration setting has not been run (see step 7). Figure 12. Sensor Channel LED. 4. Check the front panel of the relay. Only the POWER LED turns on at this moment (see Figure 10). Figure 10. POWER LED Illuminated on the Front of the Relay. 7. Press and hold the SET push button on the front panel for two seconds in order to run the system auto-configuration setting (see Figure 13). The relay memorizes the sensor amount and binary input lines connected (if any). Figure 13. Location of the SET Push Button. 5. Attach the connector back to the sensor PCB (see Figure 11). Figure 11. Cable Connected to the Sensor PCB. 8. After completing the system auto-configuration setting, the ERROR LED should be reset and then close both end covers of the point sensors (see Figure 14). 5

2. Sensor Connection Figure 14. End Covers Closed on the Sensor. Figure 16. Arc Light Fiber Sensors Plugged into EAFR Relay. 9. A maximum of three arc sensors can be daisy-chained to the same sensor input on the EAFR-101 relay (see Figure 15). Figure 15. Maximum of Three Daisy-Chained Sensors. NNote: The Auto Configuration is a part of the Self Supervision Function which insures that all connections and sensors are fully functional and ready to operate at all times. 10. For arc light fiber sensors, they can be plugged into the back of an EAFR relay as shown in Figure 16. 6

3. Ordering Codes 3. Ordering Codes Eaton Catalog Number Eaton Style Number Part Number Description EAFR-110P 65C2010G01 Current, point sensor unit EAFR-110F 65C2010G02 Current, fiber loop sensor unit EAFR-101 65C2010G03 Point Sensor unit EAFR-101D 65C2010G04 Point Sensor unit, DIN Rail mounted EAFR-101S 65C2010G05 Point Sensor unit, signaling EAFR-102 65C2010G06 Fiber loop sensor unit EAFR-110PB 65C2010G07 Current, point sensor unit, NC Trip Relay EAFR-110FB 65C2010G08 Current, fiber loop sensor unit, NC Trip Relay EAFR-101B 65C2010G09 Point Sensor unit, NC Trip Relay EAFR-101DB 65C2010G10 Point Sensor unit, DIN Rail mounted, NC Trip Relay EAFR-102B 65C2010G11 Fiber loop sensor unit, NC Trip Relay EAFR-01-A 65C2011G01 Arc light point Sensor - 8,000 Lux EAFR-01-B 65C2011G02 Arc light point Sensor - 25,000 Lux EAFR-01-C 65C2011G03 Arc light point Sensor - 50,000 Lux EAFR-06-10 65C2013G01 Arc light plastic fiber sensor - 10 m (32.81 ft) EAFR-06-15 65C2013G02 Arc light plastic fiber sensor - 15 m (49.21 ft) EAFR-06-20 65C2013G03 Arc light plastic fiber sensor - 20 m (65.62 ft) EAFR-06-25 65C2013G04 Arc light plastic fiber sensor - 25 m (82.02 ft) EAFR-06-30 65C2013G05 Arc light plastic fiber sensor - 30 m (93.43ft) EAFR-06-35 65C2013G06 Arc light plastic fiber sensor - 35 m (114.83 ft) EAFR-06-40 65C2013G07 Arc light plastic fiber sensor - 40 m (131.23 ft) EAFR-07-10 65C2014G01 Arc light glass fiber sensor - 10 m (32.81 ft) EAFR-07-15 65C2014G02 Arc light glass fiber sensor - 15 m (49.21 ft) EAFR-07-20 65C2014G03 Arc light glass fiber sensor - 20 m (65.62 ft) EAFR-07-25 65C2014G04 Arc light glass fiber sensor - 25 m (82.02 ft) EAFR-07-30 65C2014G05 Arc light glass fiber sensor - 30 m (93.43ft) EAFR-07-35 65C2014G06 Arc light glass fiber sensor - 35 m (114.83 ft) EAFR-07-40 65C2014G07 Arc light glass fiber sensor - 40 m (131.23 ft) EAFR-07-45 65C2014G08 Arc light glass fiber sensor - 45 m (147.64 ft) EAFR-07-50 65C2014G09 Arc light glass fiber sensor - 50 m (164.05 ft) EAFR-08-10 65C2015G01 Arc light glass fiber sensor (High Temperature) - 10 m (32.81 ft) EAFR-08-15 65C2015G02 Arc light glass fiber sensor (High Temperature) - 15 m (49.21 ft) EAFR-08-20 65C2015G03 Arc light glass fiber sensor (High Temperature) - 20 m (65.62 ft) EAFR-08-25 65C2015G04 Arc light glass fiber sensor (High Temperature) - 25 m (82.02 ft) EAFR-08-30 65C2015G05 Arc light glass fiber sensor (High Temperature) - 30 m (93.43ft) EAFR-08-35 65C2015G06 Arc light glass fiber sensor (High Temperature) - 35 m (114.83 ft) EAFR-08-40 65C2015G07 Arc light glass fiber sensor (High Temperature) - 40 m (131.23 ft) EAFR-08-45 65C2015G08 Arc light glass fiber sensor (High Temperature) - 45 m (147.64 ft) EAFR-08-50 65C2015G09 Arc light glass fiber sensor (High Temperature) - 50 m (164.05 ft) 7

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2016 Eaton All Rights Reserved Printed in USA Publication No. MN026008EN / TBG1251 February 2016 Eaton is a registered trademark. All trademarks are property of their respective owners.