Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Similar documents
New automated laser facility for detector calibrations

Intercomparison of radiation temperature measurements over the temperature range from 1600 K to 3300 K

RADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM

NIST MEASUREMENT SERVICES:

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Photometry and Light Measurement

SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY

Instruction Manual of Luminance and Spectral Radiance Calibrations

Development of 2 Total Spectral Radiant Flux Standards at NIST

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Application Note (A16)

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: EASZE Page 2 of 14

IESNA standards on LED and SSL: LM-79, LM-80, and future standards

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

Photometry for Traffic Engineers...

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

Lighting Terminologies Introduction

Radiometry vs. Photometry. Radiometric and photometric units

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometry for Traffic Engineers...

LED Sources in Photometry at NIST

High Illuminance Calibration Facility and Procedures

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Calibrations

Influence of the light spectral distribution used in the radiometers calibration

Measurements of Infrared Sources with the Missile Defense Transfer Radiometer

CCT/10-13 MeP-K direct methods. Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry)

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

Advantages of white LED lamps and new detector technology in photometry

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

Model S471-LED Optometer

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

NEW MEASUREMENT STANDARDS AND METHODS FOR PHOTOMETRY AND RADIOMETRY

Measurement Services Optics Laboratory

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

LI-193 Spherical Quantum Sensor

Relation between the illuminance responsivity of a photometer and the spectral power distribution of a source

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

We bring quality to light. MAS 40 Mini-Array Spectrometer

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Developement of the method for realization of spectral irradiance scale featuring system of

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

Detector-Based Traceability Chain for Spectral Irradiance using Tunable Laser-Based Facility at PTB

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

Morris Products 53 Carey Road, Queensbury, NY 12804

Solid-State Lighting Photometry Issues

Radiometry vs. Photometry. Radiometric and photometric units

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Radiometric and Photometric Measurements with TAOS PhotoSensors

Catalog number Lens Option Very Narrow without diffuser Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies

BTS2048-VL-CP-ILED-B-IS-1.0-HL

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Application Note (A19)

Cat# LED Classic Large Wall-Pack

LED14.5WPAR30S/FL/827-DIM

LI-192 Underwater Quantum Sensor

The Standard for over 40 Years

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

Status of Low-Background Infrared Calibration Facility at NIST

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.



Product Tripix 300 Catalog number Lens Option Standard. Tripix300_ ies

LINEARPYROMETER LP4. Technical Documentation KE November TN

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006



Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

Photometric Test Report

Quality Manual of Luminous Intensity Laboratory

Company synopsis. Regulations and Standards

Lighting Sciences

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Properties of LED considering museum lighting

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Transcription:

Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30 May 2012 NRC, 100 Sussex Drive, Ottawa

Photometry and Spectroradiometry Outline Calibration and measurement services Present calibration chain Future calibration chain SSL facility

Photometry and Spectroradiometry Measurement Geometries - 4 basic optical radiation measurement configurations total flux illuminance / irradiance luminance / radiance intensity total flux intensity luminance radiance illuminance irradiance

Calibration services Photometry of Incandescent Lamps - total luminous flux (lumen standards) - luminous intensity standards - illuminance standards Required Working Standards Total luminous flux lamp Luminous intensity lamp Calibration of Photometric Instruments and Sources - illuminance meters - luminance meters - luminance sources Spectroradiometry - spectral irradiance lamp standards - spectral radiance source standards - spectroradiometers - irradiance - radiance + Diffuse reflectance standard Spectral irradiance lamp + Diffuse reflectance standard Spectral irradiance lamp + Diffuse reflectance standard

Working standard lamps Total luminous flux Luminous intensity Spectral irradiance Auxiliary standards Diffuse reflectance standard

Primary calibration Measurement of absolute amount of optical radiation power - SI units (watt) - absolute radiometer Room Temperature ESR Cryogenic Radiometer

Photometric calibration chain (present) Luminous Intensity: Absolute Radiometer (room temperature) SI CIE Secondary Radiometers (Si photodiodes) V(l)-correcting filter LIS lamp Luminous Intensity Standard NRC candela maintained on lamps 0.5%

Photometric calibration chain (present) Total Luminous Flux: Absolute Radiometer (room temperature) Secondary Radiometers (Si photodiodes) V(l)-correcting filter NRC lumen maintained on lamps 1.0% LIS lamp Goniophotometer 0.5%

Spectroradiometric calibration chain Spectral Irradiance (present): Absolute Radiometer (room temperature) narrow-band filter detector based FEL lamp NRC spectral irradiance maintained on lamps (FEL)

Spectroradiometric calibration chain Spectral Irradiance (present): NIST NRC Absolute Radiometer NIST FEL 1000W incandescent quartz-halogen NRC CIE NRC spectral irradiance maintained on lamps (FEL)

International Comparisons (CCPR) k=2 CCPR = Consultative Committee for Photometry and Radiometry

Optical radiation calibration chain Present: detector - based Absolute Radiometer (room temperature) Secondary Radiometers (Si photodiodes) V(l)-correcting filter narrow-band filter LFS lamp gonio photometer LIS lamp FEL lamp NIST

Optical radiation calibration chain Under construction: detector and source - based Absolute Radiometer (cryogenic) Transfer Radiometers Filter Radiometers temperature measurement high temperature blackbody (HTBB) Primary Standard Source High Temperature Fixed Points LIS lamp FEL lamp Primary Standard Pyrometer Pyrometers Photometry Spectroradiometry Radiation Thermometry

Optical radiation calibration chain Filter radiometers (5) Thermometric Photometric Spectroradiometric

Optical radiation calibration chain Photometer filter radiometer V(l)-correcting filter aperture photodiode aluminum cell thermo-electric coolers

Optical radiation calibration chain Photometer filter radiometer Source of Uncertainty Type of Uncertainty Standard Uncertainty Spectral responsivity B 0.14% Spatial uniformity B 0.20% Aperture area B 0.07% Spectral mismatch B 0.06% Temperature control B 0.04% Aging B 0.03% Lamp to photometer distance d A 0.20% Photocurrent A 0.02% Combined standard uncertainty 0.33%

Optical radiation calibration chain Under construction: detector and source - based Absolute Radiometer (cryogenic) Transfer Radiometers Filter Radiometers temperature measurement high temperature blackbody (HTBB) Primary Standard Source High Temperature Fixed Points LIS lamp FEL lamp Primary Standard Pyrometer Pyrometers Photometry Spectroradiometry Radiation Thermometry

Optical radiation calibration chain Spectroradiometry: spectral irradiance Absolute Radiometer (room temperature) narrow-band filter detector based interpolation fit extrapolation is not valid high temperature blackbody (HTBB) Primary Standard Source thermodynamic T=? L l,t c 1 l 5 exp c 2 1 lt Planck equation

Optical radiation calibration chain Filter radiometers for spectroradiometry T L m (l m,t) i T HTBB filter radiometer L m L m l m,t l m 5 c 1 exp c 2 1 l m T m measured value l m Measure the BB output at one wavelength

Optical radiation calibration chain Filter radiometers for spectroradiometry HTBB FR0 FR4 FR2 FR1 FR3

HTBB Temperature (K) Optical radiation calibration chain Filter radiometers for spectroradiometry k=2 uncertainties

Optical radiation calibration chain Spectral Irradiance: NIST NRC Absolute Radiometer NIST NRC CIE FEL Lamps HTBB: 1 K @ 2900 K

Optical radiation calibration chain Spectral Irradiance: transfer facility (under construction) Filter Radiometer transfer standard lamps HTBB High-Temperature Black-Body Transfer standard lamps (incandescent) spectroradiometer filter radiometers

Calibration services Incandescent Sources Solid State Sources peak intensity axis #2 mechanical axis optical axis peak intensity axis

Calibration services Solid State Sources (facility under development) LED front tip Averaged LED Intensity (CIE 127:2007) detector aperture circular acceptance area of 100 mm 2 mechanical axis Condition B d B = 100 mm Condition A d A = 316 mm

Calibration services Solid State Sources (facility under development) Partial LED Flux (CIE 127:2007) d 50 mm circular aperture

Calibration services Photometry of Incandescent Lamps - total luminous flux (lumen standards) - luminous intensity standards - illuminance standards Calibration of Photometric Instruments and Sources - illuminance meters - luminance meters - luminance sources Spectroradiometry - spectral irradiance lamp standards - spectral radiance source standards - spectroradiometers - irradiance - radiance SSL facility

Discussion Thank you