Modular range of digital protection relays

Similar documents
Substation applications

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

BUS2000 Busbar Differential Protection System

Protection and control. Sepam range Sepam 2000 Metering and protection functions

These drawings and single line diagrams provide an outlook of Basler Electric solutions for Excitation System installations and retrofit

Protection of Electrical Networks. Christophe Prévé

Protection and control. Sepam range Sepam 2000 Generator

Generator Protection GENERATOR CONTROL AND PROTECTION

Protection and control. Sepam range Sepam 2000 Testing

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Overview. HighPROTEC Line. POWER DISTRIBUTION Controlling the Power of Energy PROTECTION AND CONTROL RELAYS FOR YOUR POWER SYSTEMS

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

Transformer protection IED RET 670

PD300. Transformer, generator and motor protection Data sheet

Power systems Protection course

EE Lecture 14 Wed Feb 8, 2017

COPYRIGHTED MATERIAL. Index

HighPROTEC-2 ELECTRICAL PROTECTION MADE SIMPLE

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

PROTECTION of electricity distribution networks

SEL-311C TRANSMISSION PROTECTION SYSTEM

HighPROTEC-2 ELECTRICAL PROTECTION MADE SIMPLE

MiCOM P642, P643 and P645

SPAD 346 C Stabilized differential relay

Protection and control. Sepam range Sepam 1000 Substations Busbars Transformers Motors

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Fixed Series Compensation

REF 610 Feeder Protection Relay. Technical Reference Manual

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

FMR. Ultra Line FEEDER MANAGER RELAY

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Stabilized Differential Relay SPAD 346. Product Guide

Power Plant and Transmission System Protection Coordination Fundamentals

Protective Relays Digitrip 3000

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

SIPROTEC. Multi-Functional Generator Protection Relay 7UM61. Preface. Contents. Introduction 1. Functions 2. Mounting and Commissioning 3

Advanced, accurate and intelligent monitoring for your transformer

System Protection and Control Subcommittee

Power Plant and Transmission System Protection Coordination

presentation contents application advantages

Detecting and Managing Geomagnetically Induced Currents With Relays

Improve asset protection and utilization

ENOSERV 2014 Relay & Protection Training Conference Course Descriptions

NERC Protection Coordination Webinar Series July 15, Jon Gardell

PARAMETER LIST PARAMETER LIST

489 Generator Management Relay Instruction Manual

Multimeter 500CVD21 RTU500 series

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Protective Relaying for DER

Power Plant and Transmission System Protection Coordination

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Protection and control. Sepam range Sepam 2000 Metering and control

Replacement solution

A proven distribution feeder solution with integrated protection, monitoring, and control

www. ElectricalPartManuals. com REM 543 Motor Protection Relay Application Pre-Configured Models Features Your Investment

Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide

Waterpower '97. Upgrading Hydroelectric Generator Protection Using Digital Technology

489 Generator Management Relay

Protection and control. Sepam range Sepam 2000 SX

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

2015 Relay School Bus Protection Mike Kockott March, 2015

O V E R V I E W O F T H E

Protection Relays. U-MLEs-PLv. Ultra Line. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Utility Interconnection and System Protection

FUJI Inverter. Standard Specifications

Generator Protection M 3420

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Table of Contents. Introduction... 1

Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Reliable power onboard and offshore

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Končar TMS - Bushing monitoring

System Protection and Control Subcommittee

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

Power System Protection Lecture Notes

Generator Protection M 3425

Advanced Test Equipment Rentals ATEC (2832)

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY

Industrial Electrician Level 3

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

INSTRUCTION MANUAL. AQ F3x0 Feeder protection IED

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Circuit breakers for direct current applications

AF91 Adjustable Frequency Drives Series B

Instruction Book. M 3425A Generator Protection

L90 Line Differential Relay

Optimizing HV Capacitor-Bank Design Protection & Testing

Instruction Book. M-3425A Generator Protection

7PG2113/4/5/6 Solkor Feeder Protection Answers for energy

Using a Multiple Analog Input Distance Relay as a DFR

Transcription:

S e p a m s e r i e s 2 0, 4 0, 8 0 Modular range of digital protection relays Fast Dependable Simple

Fast response Maximum dependability Your electrical equipment is under control. With Sepam protection relays, your get maximum energy availability for your process. 2

N u m b e r o n e i n d e p e n d a b i l i t y Maximize energy availability and the profi ts generated by your installation while protecting life and property. K e e p i n f o r m e d t o m a n a g e b e t t e r With Sepam, you get intuitive access to all system information in your language so that you can manage your electrical installation effectively. If a problem occurs, clear and complete information puts you in a position to make the right decisions immediately. The electrical supply is restored without delay. M a i n t a i n i n s t a l l a t i o n a v a i l a b i l i t y Sepam maintains high energy availability thanks to its diagnostics function that continuously monitors network status. In-depth analysis capabilities and high reliability ensure that equipment is de-energized only when absolutely necessary. Risks are minimized and servicing time reduced by programming maintenance operations. E n h a n c e i n s t a l l a t i o n d e p e n d a b i l i t y Launch of fi rst multi-functional digital protection relay Over 400,000 Sepam units installed around the world Sepam series 80 is the fi rst digital protection relay to deliver dependability and behaviour in the event of failure meeting the requirements of standard IEC 61508. Sepam manufacturing quality is so high that the units can be used in the most severe environments, including off-shore oil rigs and chemical factories (IEC 60062-2-60). S t a n d a r d I E C 6 1 5 0 8 Electric utilities, petrochemical plants, hospitals, infrastructures, shopping centres, small industry. 3

A set of simple and effective functions suited to your customer s application Fast response from Schneider Electric: save time at every step in your project With Sepam protection relays, you can count on simple, high-performance products and the support of top-notch Schneider Electric teams. Meet your obligations the easy way. 4

Save time at every step in project development and installation to consistently meet your project deadlines. G o f o r s i m p l i c i t y With multi-functional Sepam protection relays, you can measure, manage, analyze and produce diagnostics for all applications in an installation. Range modularity makes it easy to select the relay corresponding exactly to your needs. The range is structured for typical applications (substations, transformers, generators, capacitors, busbars and motors) and provides the necessary functions for each application (protection, metering, control and monitoring, etc.). Starting with a Sepam base unit, complete solutions can be built up by adding input/output modules, sensors and communication modules. M a k e s e t t i n g s e a s i l y A single PC software tool for the entire Sepam range makes system start-up and operation particularly easy. The user-friendly program guides you step by step from the initial programming on through to fi nal commissioning. Sepam produces a detailed report on system confi guration and all the activated protection functions. On Sepam series 80, the entire setup is saved to a memory cartridge that can be accessed in front, for instance when replacing a unit. Schneider Electric does business in 190 countries The time required to make a Sepam unit available anywhere in the world C o m m u n i c a t e t h e o p e n w a y In addition to the DNP3 and IEC 60870-5-103 Modbus standards, Sepam complies with IEC 61850 and uses the communication protocol that is today s market standard to interface with all brands of electrical-distribution devices. S t a n d a r d I E C 6 1 8 5 0 Installation Setup Local display Supervision 5

A S Sepam range design is based on a simple idea. All users should be able to fi nd a solution corresponding exactly to their needs and offering the right balance between performance, simplicity and cost. e p a m r e l a y f o r e a c h a p p l i c a t i o n C u s t o m Long distance a n d d i f f e r e n t l e v e l s o f p r o t e c t i o n Thermal protection based on temperature rise calculations, with predictive indications to optimize process control. Directional phase-overcurrent protection for closedloop networks. Directional earth-fault protection for all types of neutral systems. Fast and highly-sensitive protection of transformers, motors and generators using differential functions with restraint. 6

F o r c u s t o m a p p l i c a t i o n s S e p a m s e r i e s 8 0 Sepam series 80 Sepam series 40 Sepam series 20 D e m a n d i n g U s u a l Standardized dimensions for enhanced protection of incomers/feeders, transformer, motor, generator, bus, capacitor-bank applications Differential protection of transformer or machine transformer units Differential protection of motors and generators Protection for incomers, couplings and important feeders Expanded logic-equation capabilities Graphical assistance for setting software Battery backup for historical and fault waveform data retention Optional mimic-based display units are available to view a portion of single-line and phasor diagrams F o r d e m a n d i n g a p p l i c a t i o n s S e p a m s e r i e s 4 0 Compact case provides standardized dimensions (< 100 mm deep) Directional over-current protection for dual incomers, couplings and closed-loop feeders Current and voltage inputs Setting software with Boolean logic equation assistance CT/VT and trip circuit supervision Sixteen seconds of fault recording confi gurable for multiple captures, detailed history of last 5 trip reports and retention of last 200 time-tagged alarms 16 RTD inputs F o r u s u a l a p p l i c a t i o n s S e p a m s e r i e s 2 0 Backlit LCD graphic bitmap display 16 inverse time over-current characteristic curves Easy software setup Two 86-cycle fault records, last trip fault values and last 64 time-tagged alarms Self-test diagnostics Wide range of control power inputs (AC/DC) Breaker/Failure function for S23 and T23 7

Three relay series with increasing protection capabilities for six types of applications to provide all possible protection confi gurations. S e r i e s 2 0 S e r i e s 4 0 Applications Substations Transformers Motors Current Temperature Current Voltage Frequency Temperature Generators Busbars Capacitors Voltage Frequency Protection functions 26/63, 27/27S, 27D, 27R, 30, 37, 38/49T, 46, 48, 49RMS, 50/51, 50BF, 50G/51G, 50N/51N, 51LR, 59, 59N, 66, 68, 79, 81H, 81L, 81R, 86, 94/69 + directional protection 26/63, 27/27S, 27D, 27R, 30, 32P, 32Q/40, 37, 38/49T, 46, 47, 48, 49RMS, 50/51, 50BF, 50G/51G, 50N/51N, 50V/51V, 51LR, 59, 59N, 60/60FL, 66, 67, 67N/67NC, 68, 79, 81H, 81L, 86, 94/69 Characteristics Logic input/outputs Temperature sensors Channels Communication ports Control Inputs 0 to 10 Outputs 4 to 8 0 to 8 Current 3I + Io Voltage 3V + Vo LPCT (1) 1 to 2 Matrix (2) Inputs 0 to 10 Outputs 4 to 8 0 to 16 Current 3I + Io Voltage 3V LPCT (1) 1 to 2 Matrix (2) Logic equation editor Other A N S I c o d e s (1) LPCT: low-power current transducer complying with standard IEC 60044-8. (2) Control matrix for simple assignment of information from the protection, control and monitoring functions. Codes and definitions 12 Overspeed (2 set points) 14 Underspeed (2 set points) 21B Underimpedance 24 Overfl uxing (V/Hz) 25 Synch-check 26/63 Thermostat / Buchholz 27/27S Undervoltage (L-L/L-N) 27D Positive-sequence undervoltage 27R Remanent undervoltage 30 Annunciation 32P Directional real overpower 32Q/40 Directional reactive overpower 37 Phase undercurrent 37P Directional active underpower 38/49T Temperature monitoring 40 Field loss (underimpedance) 46 Unbalance/negative sequence 47 Negative sequence overvoltage 48 Excessive starting time 49RMS Thermal overload 50/27 Inadvertent energization 50/51 Phase overcurrent 50BF Breaker failure 50G/51G Ground sensitive 50N/51N Ground fault 50V/51V Voltage restrained overcurrent 51C Capacitor bank unbalance 51LR Locked rotor 59 Overvoltage (L-L or L-N) 59 Overvoltage (L-L) 59N Neutral voltage displacement 60/60FL CT/VT supervision 8

2 3 1 S e r i e s 8 0 5 Current Voltage Frequency Temperature Rotation speed 6 4 7 B u i l d y o u r o w n s o l u t i o n + directional and differential protection 12, 14, 21B, 24, 25, 26/63, 27/27S, 27D, 27R, 30, 32P, 32Q/40, 37, 37P, 38/49T, 40, 46, 47, 48, 49RMS, 50/27, 50/51, 50BF, 50G/51G, 50N/51N, 50V/51V, 51C, 51LR, 59, 59N, 60/60FL, 64G, 64REF, 66, 67, 67N/67NC, 68, 74, 78PS, 79, 81H, 81L, 81R, 86, 87M, 87T, 94/69 Inputs 0 to 42 Outputs 5 to 23 Current Voltage LPCT (1) Matrix (2) Logic equation editor Logipam (3) Memory cartridge with settings Backup battery 0 to 16 2 x 3I + 2x Io 2 x 3V + Vo 2 to 4 (3) Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions. 64G 100% stator earth fault 64REF Restricted earth fault 66 Starts per hour 67 Directional phase overcurrent 67N/67NC Directional ground fault 68 Logic discrimination / zone selective interlocking 74 Circuit connection supervision 78PS Pole slip 79 Recloser (4 cycles) 81H Overfrequency 81L Underfrequency 81R Rate of change of frequency (df/dt) 86 Latching / acknowledgement 87M Machine differential 87T Two-winding transformer differential 94/69 Circuit breaker / contactor control 1 2 3 4 5 6 7 Base unit with integrated or remote advanced user-machine interface (UMI), or integrated mimic-based UMI (Sepam series 80). Additional input/output modules for integral equipment control. Connection to RS485 (2 or 4 wire) or optic-fi bre communication network. Protocols include Modbus, IEC 60870-5 103, DNP3.0 and IEC 61850. Module for eight temperature measurements via Pt100, Ni100 or Ni120 sensors, to protect transformers, motors and generators. Low-level analog output (0-10, 4-20, 0-20 ma) for transmission of Sepam measurements in analog form. Module to check synchronization between two voltages (Sepam series 80). Software Sepam parameter settings, protection settings and personalization of control functions, local or remote operation of the installation, disturbance recording data display. C o m p a c t a n d l i g h t, S e p a m fi t s a n y w h e r e 222 mm 176 mm 98 mm 9

The Sepam programming and operating software provides a single environment for the entire range. The result is a simple, user-friendly approach for fast system commissioning. S e t u p E q u i p m s e t u p e n t P r o t e c t i o n s e t u p P r o t e c t i o n a c t i v a t i o n S u m m a r y o f f u n c t i o n s Set up the various modules (input/outputs, display, communication, sensors). Prepare the singleline diagram either by reworking a mimic diagram from the library or by creating a new one. Graphically create the links between sensors and the measurements carried out by the relays. Assign easily and quickly the various protection, control and monitoring functions. 1 0 m i n u t e s 5 m i n u t e s 5 m i n u t e s 4 0 m i n u t e s 10 6

e s O p e r a t i o n The setup is now ready to be deployed on all the Sepam units in the installation. A n a l y s i s o f w a v e f o r m c a p t u r e Display, analysis and printing of disturbance-recording data. R e a l - t i m s u p e r v i s i o n Supervision of the status of all the relays in the electrical installation. M a n a g e m e n t o f a l a r m a n d e v e n t s Automatic generation of the relay setup report. 1 5 y e a r s o f p e a c e o f m i n d l l l 11

C u s t o m s e r v i c e s R e t r o fi t Creation of an electrical installation with a controlmonitoring architecture requires more than correct analysis of needs. The best balance between technical aspects and cost issues is the product of in-depth know-how and long experience. Your Schneider Electric representative is on hand to propose tailored services: training for technicians, discrimination studies for your network, design of the control and monitoring architecture, personalized Sepam units for your application, system tests and commissioning, installation upgrades and maintenance. Via your Schneider Electric representative, access all the resources and know-how of Schneider Electric, including the certifi ed COFRAC test lab, software for network simulations, short-circuit calculations and dynamic stability studies, etc. These resources cover all types of situations and provide solutions that fi t your needs. Sepam functions make it particularly suitable for retrofi t projects. It adapts to all types of sensors and its programming is so fl exible that any type of control scheme can be implemented. Our service teams are on hand to help you design upgrades for your installation and maintain the highest level of performance. Training is available worldwide, near you. For more information: www.sepamrelay.com Schneider Electric Industries SAS 89 Bd. Franklin-Roosevelt F-92505 Rueil-Malmaison FRANCE Tel. +33 (0) 1 41 29 70 00 www.schneider-electric.com As standards, specifi cations and designs change from time to time, please ask for confi rmation of the information given in this publication. Published by Schneider Electric Design by pemaco Photos by Getty Images, Photodisc, Patrick Avavian Printing : 07/2008