IEEE 1547: Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces

Similar documents
IEEE sion/1547revision_index.html

IEEE sion/1547revision_index.html

Revised IEEE 1547 Standard for Interconnecting Distributed Energy Resources with Electric Power Systems- National Grid Solar Program

IEEE SCC Standards Update

IEEE Major Revision of Interconnection Standard

IEEE Std Bulk System Opportunities from New Distributed Energy Resource Interconnection and Interoperability Standards

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

Inverter Source Requirement Document of ISO New England (ISO-NE)

Preview of the New Interconnection Standard

Implementation of Revised IEEE Standard 1547

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Ameren Illinois Company d/b/a Ameren Illinois Smart Inverter Specifications

BED INTERCONNECTION TECHNICAL REQUIREMENTS

Final ballot January BOT adoption February 2015

Grid Converters for Photovoltaic

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

Modelling Parameters. Affect on DER Impact Study Results

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

Roadmap For Power Quality Standards Development

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Transmission Interconnection Requirements for Inverter-Based Generation

Intermittent Renewable Resources (Wind and PV) Distribution Connection Code (DCC) At Medium Voltage (MV)

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

POWER QUALITY IMPACTS AND MITIGATION OF DISTRIBUTED SOLAR POWER

Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks

Protective Relaying for DER

Technical information Grid Support Utility Interactive Inverters for Sunny Central-US and Sunny Central Storage-US

Table of Contents. Introduction... 1

Wind Power Facility Technical Requirements CHANGE HISTORY

E N G I N E E R I N G M A N U A L

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

RENEWABLE ENERGY SUB-CODE for Distribution Network connected Variable Renewable Energy Power Plants in Ghana

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Impact of High PV Penetration on Grid Operation. Yahia Baghzouz Professor of Electrical engineering University of Nevada Las Vegas

Possible Future Modifications to IEEE 1547

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

2012 Grid of the Future Symposium. Impacts of the Decentralized Photovoltaic Energy Resources on the Grid

Southern Company Power Quality Policy

Rule 21 Working Group 3.

Risk of unintentional islanding in the presence of multiple inverters or mixed generation types

GRID CONNECTION CODE FOR RENEWABLE POWER PLANTS

TechSurveillance. Revision of IEEE Standard New Reactive Power and Voltage Regulation Capability Requirements. Business & Technology Strategies

The development of the SA grid code on Power Quality emission. Dr. Gerhard Botha 2017/08/08

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

ECE 528 Understanding Power Quality

Impact of Distributed Generation on Voltage Regulation by ULTC Transformer using Various Existing Methods

GRID CONNECTION CODE FOR RENEWABLE POWER PLANTS (RPPs)

System Requirements for Wind Farms and Distributed Generation. Giuseppe Di Marzio

1

Southern Company Interconnection Requirements for Inverter-Based Generation

Generation and Load Interconnection Standard

The Connecticut Light and Power Company

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Testing Advanced Photovoltaic Inverters Conforming to IEEE Standard 1547 Amendment 1

Declaration of Conformity

DER Ride-Through Performance Categories and Trip Settings Presentation at PJM Ride-Through Workshop, Philadelphia, PA, October 1-2, 2018

Inverter-Based Resource Disturbance Analysis

MEASUREMENT CAMPAIGN AND ASSESSMENT OF THE QUALITY OF SUPPLY IN RES AND DG FACILITIES IN SPAIN

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Power Quality Basics. Presented by. Scott Peele PE

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

Babak Enayati National Grid Thursday, April 17

Generation and Load Interconnection Standard

Target Mchunu and Themba Khoza Eskom Transmission Division, System Operator Grid Code Management

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

An Introduction to Power Quality

Power System Protection Where Are We Today?

Information and Technical Requirements For the Interconnection of Distributed Energy Resources (DER)

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form

Phase-phase/phase-neutral: 24/13.8 kv star, 13.8 kv delta, 12/6.9 kv star.

TECHNICAL GUIDELINE FOR THE INTERCONNECTION OF DISTRIBUTED ENERGY RESOURCES TO EPCOR DISTRIBUTION AND TRANSMISSION INC. S DISTRIBUTION SYSTEM

Version 2.6 October Comments to this document can be forwarded to:

PQ Monitoring Standards

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Connection Impact Assessment Application

Power Quality Requirements for Connection to the Transmission System

Wind Requirements and Testing for Steady-State Voltage and Frequency Control

MEASUREMENT METHODS OF THE CHARACTERISTICS AND TARGET VALUES OF THE VOLTAGE QUALITY SUPPLIED BY HYDRO-QUEBEC SYSTEM

DRAFT. City of Lethbridge Electric ENGINEERING STANDARDS GUIDELINE FOR GENERATOR INTERCONNECTION THE CITY OF LETHBRIDGE ELECTRIC DISTRIBUTION SYSTEM

900 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

DYNAMIC VOLTAGE RESTORER FOR VOLTAGE SAG MITIGATION IN OIL & GAS INDUSTRY

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

Sizing Generators for Leading Power Factor

GUIDE FOR GENERATOR INTERCONNECTION THE WIRES OWNER DISTRIBUTION SYSTEM

Energy Networks Association

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR INTERCONNECTION OF GENERATION FACILITIES NOT SUBJECT TO FERC JURISDICTION

Power Quality enhancement of a distribution line with DSTATCOM

POWER QUALITY REPORT

Voltage Control with Distributed Generators to Enhance Voltage Stability

POWER QUALITY AND SAFETY

Fault Ride Through Technical Assessment Report Template

Transcription:

IEEE PES Boston Chapter Technical Meeting IEEE 1547: Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces P1547 Chair David Narang P1547 Secretary/Treasurer Charlie Vartanian Vice Chairs (Central Desktop [CD] Subgroup Leaders) John Berdner Jim Daley Babak Enayati Mark Siira IEEE SCC21 Liaison Mike Kipness, Presenter: Babak Enayati National Grid Waltham, MA Babak.Enayati@nationalgrid.com Office: 781-907-3242 Nov 9, 2016 The draft material in this presentation is in reference to IEEE 1547 Revision Draft 5.0

Index What is IEEE 1547? Ride through Voltage regulation Power Quality Overview of interoperability, island systems, and testing

Challenges of Grid Modernization Traditional Electric Grid Modern Electricity Choices Utility Scale PV Power park Wind Farms Rooftop Photovoltaics Hydrogen Storage Industrial DG Fuel Cells Remote Loads 3 3 EV s Load as a resource Smart Substation Combined Heat and Power

P1547 Revision: Draft Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces. Scope: This standard establishes criteria and requirements for interconnection of distributed energy resources (DER) with electric power systems (EPS), and associated interfaces. Note: Interfaces defined in IEEE 2030: a logical interconnection from one entity to another that supports one or more data flows implemented with one or more data links. Purpose: This document provides a uniform standard for the interconnection and interoperability of distributed energy resources (DER) with electric power systems (EPS). It provides requirements relevant to the interconnection and interoperability performance, operation, and testing, and, safety, maintenance and security considerations.

5

1547: Interconnection Is The Focus IEEE Std 1547 covers: - INTERCONNECTION TECHNICAL SPECIFICATIONS & REQUIREMENTS - INTERCONNECTION TEST SPECIFICATIONS & REQUIREMENTS Distributed Energy Resource (DER) unit Interconnection System Note: P1547 full revision started in year 2015 is also addressing interoperability and interfaces Area Electric Power System (EPS) 6

IEEE 1547 IS: IEEE 1547 Is NOT: IEEE 1547.1 is: Test Procedures for Conformance to1547 A Technical Standard Functional Requirements For the interconnection itself the interconnection test Technology neutral, e.g., does not specify particular equipment nor type A single (whole) document of mandatory, uniform, universal, requirements that apply at the PCC or Point of DER Connection. Should be sufficient for most installations. a design handbook an application guide an interconnection agreement prescriptive, e.g., does not address DR self-protection, nor planning, designing, operating, or maintaining the Area EPS. 7

IEEE Std 1547a Amendment 1, May 2014 (Amendment 1: revisions to 4.1.1, 4.2.3, and 4.2.4) 4.1.1 Voltage Regulation DER allowed to change its output of active and reactive power. 4.2.3 (Response to abnormal grid ) Voltage. DER allowed to ride through abnormalities of grid voltage; grid and DER operators can mutually agree to other voltage trip and clearing time settings 4.2.4 (Response to abnormal grid ) Frequency DER allowed to provide modulated power output as a function of frequency grid and DER operators can mutually agree to other frequency trip and clearing time settings 8

PCC vs Point of DER Connection

Point of Evaluation Requirements shall be met at the Point of Common Coupling (PCC) for all Local EPS having an aggregate DER nameplate rating of 500 kw or greater, and having an average load demand of equal or less than 10% of the DER nameplate rating. In all other situations, the applicable point for meeting performance requirements shall be the Point of DER connection

P1547 New Requirements for Ride Through (Work In Progress) Three Categories of DER Operational Responses to Support the Grid -- Based on Local and Farther Reaching Grid Requirements and DER

Voltage (p.u.) P1547 Example New Requirements for voltage Ride Through (work in progress) 1.30 1.20 1.10 1.00 may ride-through 0.16 s or may trip 2 Permissive Operation Continuous Operation Category I (based on German requirements for sync. gen.) 1 s may ride-through 1.20 p.u. 13 s 1 1.10 p.u. shall trip NERC PRC-024-2 0.90 0.80 Mandatory Operation 0.88 p.u. may ride-through or may trip 0.88 p.u. 0.70 0.60 0.50 0.40 0.30 0.20 Permissive Operation may ride-through or may trip 0.16 s German MV Code for syncr. DER 0.16 s 0.16 s 2 0.50 p.u. 2 s 1 2 s 0.10 0.00 p.u. 0.00 p.u. shall trip 0.00 0.01 0.1 1 10 100 1000 Time (s) 21 s Legend range of adustability default value shall trip zones may ride-through or may trip zones shall ride-through zones and operating regions describing performance

Frequency (Hz) P1547 Example New Requirements for frequency Ride Through (work in progress) 63.0 62.5 62.0 61.5 61.0 60.5 60.6 Hz may ride-through or may trip Mandatory Operation 66.0 Hz 66.0 Hz 62.0 Hz 0.16 s 2 Category I, II, and III (harmonized) shall trip 180 s 299 s 1 1 000 s 61.0 Hz 1 000 s may ride-through or may trip 60.0 59.5 Continuous Operation (V/f 1.1) 59.0 59.0 Hz Legend 180 s 1 000 s 58.5 may ride-through or 1 Mandatory Operation range of adustability may trip zones 58.0 299 s default value shall ride-through zones and operating regions 57.5 shall trip zones describing performance 57.0 Hz 57.0 may ride-through 0.16 s may ride-through or may trip 1 000 s 56.5 or may trip 2 shall trip 56.0 0.01 0.1 50.0 Hz 1 10 100 50.0 Hz 1000 Time (s) 14

Distribution grid impacts that need to be carefully reviewed by the utility protection engineer!! Distribution Feeder Fault Detection Anti-islanding protection

P1547 voltage regulation (Work In Progress) Two performance categories are defined for DERs with voltage regulation capabilities: a) Category A covers minimum performance capabilities needed for Area EPS voltage regulation and are reasonably attainable by all state-of-theart DER technologies b) Category B covers all requirements within Category A and specifies additional requirements to mitigate voltage variations due to resource variability

P1547 Example New Reactive Power Requirements (Work In Progress) The DER shall be capable of injecting reactive power (over-excited) and absorbing reactive power (under-excited) equal to the minimum reactive power (kvar) corresponding to the value given in Table TBD at all active power output greater than or equal to 20% of nameplate active power rating (kw) or the minimum steady-state power capability of the DER, whichever is greater. As an additional requirement, Category B DER shall provide said capability at all active power levels subject to the restriction that the ratio of the average of absolute value of DER reactive power over the preceding 24 hour period divided by the average of absolute value of DER apparent power over the preceding 24 hour period is less than 0.44.

Voltage and Reactive Power Control The DER shall provide the capabilities of the following modes of reactive power control functions: 1. Adjustable Constant Power factor mode The capability is mandatory for categories A and B 2. Voltage-reactive power (Volt-var) mode The capability is mandatory for categories A and B 3. Active power-reactive power mode (watt-var) The capability is optional for category A and mandatory for categories B 4. Reactive power mode The capability is mandatory for categories A and B

P1547 Example New Reactive Power Requirements (Work In Progress) Reactive Power (% of Stated Capability) 0 Injecting (over-excited) Absorbing (under-excited) V L (V 1,Q 1 ) V Ref (V 3,Q 3 ) Voltage (p.u.) V 1 V 4 V H (V 2,Q 2 ) Dead Band V L : Voltage Lower Limit for DER Continuous operation V H : Voltage Upper Limit for DER Continuous operation (V 4,Q 4 )

The Volt/VAR characteristics curve is adjustable Volt-var Parameters Definitions Default Values for Cat A DER Default Values for Cat B DER Minimum Adjustable Range Maximum 20 V Ref Reference voltage Nominal Voltage (V N ) V 2 Dead band lower Voltage Limit Nominal Voltage (V N ) Nominal Voltage (V N ) V Ref 0.02 V N Reactive power injection or 0 Q 0 2 absorption at voltage V 2 Dead band upper Voltage Limit Nominal Voltage V V Ref + 0.02 V N 3 (V N ) Q 3 V 1 Q 1 Reactive power injection or absorption at voltage V 3 Voltage at which DER shall inject Q 1 reactive power Reactive power injection at voltage V 1 0 0 0.95 V N 1.05 V N Cat A: V ref Cat B; V Ref 0.03 V N 0 V Ref c 0.9 V N V Ref 0.08 V N 0.82 of V N 25% of Nameplate kva 100% of stated reactive capability 0 0 V Ref 100% of stated reactive capability Cat A: V ref Cat B: V Ref + 0.03 V N 100% of stated reactive capability V 2 c -0.02 V N 100% of stated reactive capability V 4 Voltage at which DER shall absorb Q 4 reactive power 1.1 pu V Ref + 0.08 V N V 3 c +0.02 V N 1.18 V N Q 4 Reactive power absorption at voltage V 4 25% of Nameplate kva 100% of stated reactive capability 0 100% of stated reactive capability b Open Loop Response Time Mode/setting time Time to 95% of the reactive power change in response to the change in voltage Maximum Time by which mode or setting changes are to be made effective 10 sec 5 sec 1s 90s 60s 60s 5s 5 min

Active Power Reactive Power (Watt-Var or P - Q) Mode When in this mode, the DER shall actively control the reactive power output as a function of the real power output following a target real power reactive power (Watt-Var or P-Q) characteristic. Qmin inj (P 3,Q 3) Injection/ Capacitive/ Over Excited P/P rated (P 1,Q 1) -1 P 3 (P 2,Q 2) -0.2 (0,0) 0.2 (P 1, Q 1 ) (P 2, Q 2 ) P 3 P/P Rated 1 Absorption/ Inductive/Under Excited (P 3, Q 3 ) Qmin abs

P1547 Example New Voltage Regulation Requirements (Work In Progress) Voltage-Real Power (Volt-Watt) Mode When in this mode, the DER shall actively control the real output power as a function of the system voltage following a target voltage active power (voltwatt) characteristic curve. P 4 Power P 4 Power P pre-disturbance P pre-disturbance V 4 V 1 V 2 V 3 P 3 Voltage (% of V N ) V 4 V 1 V 2 V 3 Voltage (% of V N ) P 3 ESS going into Charge mode

Transition from abnormal to normal voltage conditions The requirements of the voltage regulation clause (4.1) apply to normal voltage range when the voltage is between 0.88 and 1.1 times the nominal voltage (VN). The voltage conditions outside of this range are defined to be abnormal. The DER shall return to its predisturbance operating mode after the system voltage returns to its normal range.

Grid impacts that need to be carefully reviewed by the utility engineer!! Anti-islanding protection Reactive Power coordination amongst existing DERs and utility assets i. e. capacitor banks, etc. Prioritizing the voltage regulation schemes

25 Are voltage regulation and ride-through requirements proposed to be mandatory? The ride-through capability and performance is proposed to be mandatory. The voltage regulation capability is proposed to be mandatory but the performance is proposed to be at the utility s discretion (The DER will provide this capability and the utility will decide to enable/disable it and choose the proper operating modes).

Rapid voltage changes (RVC) Rapid voltage changes are considered to be changes in fundamental frequency voltage less than one second. The DER shall not cause the ΔV/V voltage variations to go outside the limits specified in table X. (Ref. IEEE 1453) Number of Changes n ΔV/V % n 4 per day 5-6 n 2 per hour and > 4 per day 4 2 < n 10 per hour 3

Flicker Flicker- Flicker is the subjective impression of fluctuating luminance caused by voltage fluctuations. Assessment methods for flicker are defined in IEC 61000-3-7. P st99% (99 th percentile value) shall not be greater than 0.9. If not specified differently, the Pst evaluation time is 10 minutes. P lt99% (99 th percentile value) shall not be greater than 0.7. If not specified differently, the P lt evaluation time is 2 hours.

P1547 Example New Power Quality Requirements (Work in progress) Harmonics: When the DER is serving balanced linear loads, harmonic current injection into the Area EPS at the Point of DER interconnection shall not exceed the limits stated below. The harmonic current injections shall be exclusive of any harmonic currents due to harmonic voltage distortion present in the Area EPS without the DER connected.

P1547 Example New Power Quality Requirements Over Voltage Contribution-Temporary Over-voltage (TOV) The DER shall not contribute to instantaneous or RMS over voltages with the following limits: The DER shall not cause the RMS Line-Ground voltage on any portion of the Area EPS that is designed to operate effectively grounded, as defined by IEEE C62.92.1, to exceed 138% of its nominal line-ground RMS voltage for duration of exceeding one fundamental frequency period. The DER shall not cause the L-L RMS voltage to exceed 138% of its nominal L-L RMS voltage at any location on the Area EPS distribution system for duration of exceeding one fundamental frequency period. The RMS voltage measurements of this sub-clause shall be based on one fundamental frequency period.

P1547 Example New Power Quality Requirements Over Voltage Contribution-Transient Over-voltage (TROV) The DER shall not cause the instantaneous voltage at the point of common coupling (PCC) to exceed the magnitudes and cumulative durations shown in figure TBD. The cumulative duration shall only include the sum of periods for which the instantaneous voltage exceeds the respective threshold. Voltage (Per Unit of Nominal Instantaneous Base) 2 1.7 1.4 1.3 Acceptable Region Non- Acceptable Region 1.6 3 16 166 Duration (miliseconds)

Interoperability and interfaces Significant New Additions to IEEE 1547 Interoperability requirements will be included Additional interfaces addressed not only the PCC Informative material to be included

Frequency Droop During temporary frequency disturbances, for which the system frequency is outside the adjustable deadband db OF and db UF, but still between the trip settings, the DER shall adjust its active power output from the predisturbance levels, according to the formulas in Table below: Formula for frequency-droop (frequency/power) operation Operation for Low-Frequency Ride-Through Operation for High-Frequency Ride-Through p = min f<60 db UF p pre + p rated 60 db UF f 60 k UF, p avl p = max f>60+db OF p pre p rated f 60 + db OF 60 k OF, p min

Active power output in percent of nameplate shall trip Frequency Droop Example Example of a frequency-droop function with a 5% droop, 36 mhz deadband, and 20% minimum active power output 120% 100% Frequency-Droop 80% 60% shall trip 40% 20% 0% 56 57 58 59 60 61 62 63 64 DER with 90% loading DER with 75% loading DER with 50% loading

Other areas being discussed in P1547 Voltage Ride-Through requirements for consecutive temporary voltage disturbances Voltage regulation during ride through Island systems Interoperability Testing..

Thank you! Questions? http://grouper.ieee.org/groups/scc21/1547_revision/1547revision_index.html