AIR DATA CONVERTER UNIT DESIGN SPECIFICATION MODEL: ADCU-500, P/N

Similar documents
INSTALLATION MANUAL Multi-Function Digital Bus Reader Model IND-5000, P/N (XX) TACAN, Distance & Bearing June 1997

P/N ( )

EQUIPMENT INSTALLATION MANUAL. for the GDC62 RADIO ALTIMETER INTERFACE UNIT P/N

P/N X-00X( ) and P/N ( )

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

EQUIPMENT INSTALLATION MANUAL. for the GDC18 DATA CONVERTER P/N ( )

MGL Avionics Garrecht VT-0102 mode-s transponder Interface installation manual

P/N ( )

Samson S45 INSTALLATION MANUAL AVE-S IM

SAE5-35. Altitude Data System Installation Manual Rev. 4. SANDIA aerospace, Inc.

AR850 ALTITUDE REPORTER (L/C)30,700ft

RMI-Converter AC ( ) AC ( ) Installation and Operation. Manual DV Issue 1 January 1993

INSTALLATION MANUAL INSTALLATION MANUAL AV- 300 /350. Broadcast Datalink Receiver

INSTALLATION, OPERATION MANUAL

Avidyne Traffic Advisory Systems TAS 600, TAS 605, TAS 610, TAS 615, TAS 620 and Avidyne/Ryan 9900BX INSTALLATION MANUAL

Technical Standard Order

VHF-422B X X X

Model 1791 VHF Radio User's Manual

9800 Martel Road Lenoir City, TN

AUDIO MODE SELECTOR MODEL AMS-6000

MX170C NAV-COMM OWNER'S MANUAL

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

AP 100 AUDIO PANEL. Installation and Operator s Manual

Installation Manual and Operating Instructions. Model MD /707 Series Course Deviation Indicator

QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s 2M805 Series Connector

LOGIC Component Technology VOLTAGE SENSOR SENSORS & DETECTORS Voltage Sensor Data Sheet: DS-VS-14

Rockwell Collins, Inc. VHF Users Manual

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

TEGAM INC. MODEL DSRS-5DA DECADE SYNCO/RESOLVER STANDARD

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY AND MICROPHONE, DYNAMIC, M26542/9-01 AND M-133/U

Ref: UAN/DIN/SCNS rev.: -- Date February 17, VHF DATA Radio EVR A EVR A EVR B

Avidyne Traffic Advisory Systems TAS 600 TAS 610 TAS 620 and Avidyne/Ryan 9900BX INSTALLATION MANUAL

AWOS Owners / Installation / Operation Manual

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

AMS44 and AMS44T Dual Channel Audio Controllers OPERATOR S MANUAL

DESCRIPTION, INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Military COTS. 28 V DC-DC VI Chip Modules

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

80i-110s AC/DC CURRENT PROBE

20W Solid State Power Amplifier 6-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

TM POWER AMPLIFIER AM-6545A/GRC-193A (NSN )

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

PERFORMANCE SPECIFICATION SHEET

Model Hz to 10MHz Precision Phasemeter. Operating Manual

MODEL 3810/2 Line Impedance Stabilization Network

2. See Manual Part 1.4.1, (Identical Items, "Boilerplate" for all Manual Parts), Section A. Draft

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

MS14. Military Qualified 1x4 GPS Splitter. Description TECHNICAL PRODUCT DATA. Features. Designed & Manufactured to Military Specifications

MODEL AT-10 ANALOG TRANSMITTER

Apitech Valve Drive Board

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

DC-20 GHz Distributed Driver Amplifier. Parameter Min Typ Max Min Typ Max Units

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

INSTALLATION AND MAINTENANCE MANUAL FOR P/N: D564-XXX-001 L864 RED MEDIUM INTENSITY BEACON

Qualification Test Report Summary for the Smiths Connectors Solderless EMI Filtered Connector. STR #569 Revision N/C 2/09/09

Atmospheric Research Aircraft G-LUXE. Technical Specification of Scientific Equipment

9W Power Amplifier 26.2GHz~34GHz

Parameter Min. Typ. Max. Min. Typ. Max. Units

Appendix A: Specifications

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Technical Standard Order

Product Descripton. CSUv2 (Connectvity Server Unit version 2)

Installation & Service Manual

70170AC 1. (115Vac, Hz Input) 170W, 28V Single Output, Airborne PFC Power Supply

MAY 14 Rev B

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Appendix A: Specifications

OX-043 Low g-sensitivity Oven Controlled Crystal Oscillator

SINGLE-PHASE VSV SWITCH

3 CHANNEL LOAD CELL SIGNAL CONDITIONER. Owner's Manual

30W Wideband Solid State Power Amplifier 6-12GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

PERFORMANCE SPECIFICATION SHEET

100W Power Amplifier 8GHz~11GHz

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Trans-Cal Industries, Inc.

METEOROLOGICAL INSTRUMENTS

TECHNICAL PRODUCT DATASHEET

TE90 90W Single Output External Power Test & Measurement/Industrial Series

In particular, the filter module is compliant with the following requirements of MIL-STD-461C/D/E standards :

TE W Single Output External Power Test & Measurement/Industrial Series

d. Appendix 1 addresses related documents. Appendix 2 addresses definitions. Appendix 3 defines acronyms.

INSTALLATION MANUAL KI 208, KI 209 NAVIGATION INDICATORS

QNP Accessory. For BLAXH300/ MHz Operating & Service Manual. Version

Test Specification for Type Approval

Linear vs. PWM/ Digital Drives

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

LPF-100 Composite Low Pass Filter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

UL CONDITIONS OF ACCEPTABILITY

20W Solid State Power Amplifier 26.2GHz~34GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz.

2W Ultra Wide Band Power Amplifier 0.2GHz~35GHz. Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Units. Frequency Range

BENNING. CM7 Electrical Tester. Service Information

PM3000 High-fidelity Stereo Intercom System

READ THIS BEFORE ATTEMPTING TO COMBINE

Transcription:

AIR DATA CONVERTER UNIT SKYLIGHT AVIONICS 38629 6th St. East Palmdale, Ca. 93550 (661) 265-0497

INDEX Section Title Page i. OPERATING INSTRUCTIONS 1 ii. EQUIPMENT LIMITATIONS 1 iii. INSTALLATION PROCEDURES & LIMITATIONS 2-3 iv. INSTALLATION MECHANICAL 4 v. INSTALLATION ELECTRICAL 5 vi. SPECIFICATIONS 6-9 vii. MAJOR COMPONENTS 10 viii. ENVIRONMENTAL REPORT 11 ILLUSTRATIONS Illustration Title Page (iv-1) MECHANICAL DRAWING 3 (v-1) INSTALLATION DRAWING 4 (vii-1) INTERCONNECT BLOCK DIAGRAM 9 Page i

i. OPERATING INSTRUCTIONS The Model ADCU-500, P/N 02050001, ARINC-565 Air Data Computer to ARINC-429 digital bus converter. Being a data format converter only, has no independent operating instructions and should be considered transparent to the Air Data System. Being an integral part of the system, the operating instructions for that system will need to be followed. The design of the ADCU-500 is such as to cause minimal degradation of the input signal and to convert the data in the fastest and most accurate means possible. ii. EQUIPMENT LIMITATIONS The ADCU-500, is limited to converting the ARINC-565/575, Synchro, AC Analog and DC Analog signals of the currently installed Air Data Computers into a digital ARINC-429 output. The unit will accept as discrete inputs (5) valid signals from the ARINC-565 source, to assist is determining system status and (1) label select. The ADCU-500, as an integral component of the on board Air Data System, the accuracy is directly limited to the output driving it. In effect, it is a "Incomplete System" and therefore subjected to all inherent limitations of the Air Data Computer system. The conditions and test required for TSO C106 approval of this article are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine that the aircraft installation conditions are within the TSO standards. If not within the TSO standards, the article may be installed only if further evaluation by the applicant documents an acceptable installation and is approved by the administrator. System tolerances are shown in section (iii) INSTALLATION PROCEDURES, (5) POST INSTALLATION CHECK. As "Essential Equipment" a hardware design assurance of "Level C" per RTCA DO-254 Design Assurance Guidance for Airborne Electronic Hardware will be applied to design verification, documentation and manufacturing. Failure Condition Classification Major Failure Condition Description Failure conditions that would reduce the capability of the aircraft or the ability of the flight crew to cope with adverse operating conditions to the extent that there would be a significant reduction in safety margins or functional capabilities, a significant increase in flight crew workload or in conditions impairing flight crew efficiency, or discomfort to occupants, possibly including injuries. Hardware Design Assurance Level Definition C" Hardware functions whose failure or anomalous behavior, as shown by the hardware safety assessment, would cause a failure of system function resulting in a major failure condition for the aircraft". The ADCU-500, is classified as "ON CONDITION" with no preventative maintenance required. No overhaul time limitations apply. No scheduled inspections to determine operational status are required however if the Air Data Computer is removed or replaced for maintenance section (iii) INSTALLATION PROCEDURES, (5) POST INSTALLATION CHECK must be completed and system accuracy verified to maintain TSO Qualification. In the event of a failure the operator or cognizant maintenance facility shall remove the appliance and return it to Skylight Avionics for the repair or replacement. Page 1

iii. INSTALLATION PROCEDURES 1. INTRODUCTION This section contains information relative to the installation of the ADCU-500, to assure satisfactory performance of the unit. (See Sections "iv" and "v" for detailed mechanical and wiring diagrams.) 2. UNPACKING AND INSPECTING EQUIPMENT After unpacking the unit, make a visual inspection of the unit for evidence of damage incurred during shipment. If claim for damage is to be made, save the shipping container to substantiate the claim. 3. PREINSTALLATION CHECK Perform a continuity and power check on the wiring harness before connecting equipment. 4. POWER REQUIREMENTS The ADCU-500, operates from a standard 27.5 Volt DC aircraft power source. Provide circuit protection with an in line 1 AMP breaker on the 27.5 VDC. Aircraft AC is used for reference only. 5. POST INSTALLATION CHECK Follow the manufactures check out procedures of the on board systems, to determine indications being driven by the ADCU-500, are accurate. ARINC 429 Label 204/203 Altitude System must met AS8002 Rev A Table 1 Altitude to qualify for TSO-C106, Altitude Feet Tolerance Altitude Feet Tolerance 0 25 11000 35 1000 25 14000 40 2000 25 17000 45 3000 25 20000 50 4000 25 30000 75 5000 25 40000 100 8000 30 50000 125 ARINC 429 Label 206 Calibrated Air Speed System must met AS8002 Rev A Table 3 Calibrated Air Speed to qualify for TSO-C106, Airspeed Knots Tolerance Airspeed Knots Tolerance 50 5.0 250 2.4 80 3.5 300 2.8 100 2.0 350 3.2 120 2.0 400 3.6 150 2.0 450 4.0 200 2.0 Page 2

iii. INSTALLATION PROCEDURES (Cont.) ARINC 429 Label 205 Mach Number System must met AS8002 Rev A Table 4 Mach Number to qualify for TSO-C106, Altitude Feet Mach Tolerance Altitude Feet Mach Tolerance 0.3.012 30,000.6.0075.4.012.7.005.5.012.80.005.6.012.90.005.95.0075 10,000.4.012.5.010 40,000.70.005.6.0075.80.005.7.005.90.005.95.0075 20,000.4.012.5.010 50,000.75.005.6.0075.90.005.7.005.95.0075 1.00.015 ARINC 429 Label 212 Vertical Speed System must met AS8002 Rev A Table 5 Vertical Speed to qualify for TSO-C106, Vertical Speed Tolerance Vertical Speed Tolerance 6,000 300-6,000 300 4,000 200-4,000 200 2,000 100-2,000 100 1,000 50-1,000 50 500 45-500 45 200 45-200 45 100 45-100 45 50 45-50 45 0 45 There is no in-aircraft adjustment for the ADCU-500. All alignment and adjustment procedures are accomplished during bench maintenance. 6. PREFLIGHT CHECK Follow the manufactures check out procedures of the on board systems, to determine indications being driven by the ADCU-500, are accurate. Page 3

iv. INSTALLATION MECHANICAL DIAGRAMS The ADCU-500, is designed following the standards for a 2 MCU enclosure, for mounting tray installation anywhere on board the aircraft, pressurized or non-pressurized compartments. The unit requires the appropriate 2 MCU tray to be properly installed. (NOTE: Trays, connectors and miscellaneous hardware are NOT included with the ADCU.) MECHANICAL DRAWING Mechanical Drawing of ADCU-500, P/N 02050001 Illustration (iv-1) Page 4

v. INSTALLATION ELECTRICAL Electrical interconnect of ADCU-500, P/N 02050001 Page 5

Illustration (v-1) vi. SPECIFICATIONS SPECIFICATION Compliance RTCA/DO-160D CHARACTERISTICS TSO C106 D2/B/A/B/BB1R/X/X/X/X/X/X/Z/Z/A/Z/Z/RR/M/XXC3/X/X/A Physical Dimensions Height 7.796" Length 12.675" Width 2.330" Weight 4.0 Lbs. Temperature Range Altitude Power Requirements ARINC-565/575 Analog Inputs Operational -55 C to +70 C Storage -55 C to +85 C 50,000' 28 VDC @.75 AMP Peak.3 AMP Normal Pressure Altitude, Source Fine/Coarse Synchro ARINC-565 No. 2 output Accuracy ± 0.5 with respect to No. 1 Range -1000 to 50,000 ft. Index Reference 0 ft. Fine Scale Factor 360 degrees per 5000 ft. Coarse Scale Factor ratio 27:1. ADC Discrete Flag: 28VDC valid 2mA ADC 26VAC Reference Sel-Altitude, (Error) Source Fine/Coarse Synchro, Altitude Error Accuracy ± 0.5 Range -50,000 to 50,000 ft. Index Reference 0 ft. Fine Scale Factor 360 degrees per 5000 ft. Coarse Scale Factor ratio 27:1. Preselector 26VAC Reference Mach, Source Synchro ARINC-565. Accuracy.005 Mach at 0.5 through 0.95 Mach, 0.01 all others. Range 0.1 to 1.0 Mach Index Reference 0.2 Mach Scale Factor 360 per Mach ADC 26VAC Reference common to Pressure Altitude Page 6

vi. SPECIFICATIONS (cont.) ARINC-565/575 Inputs (cont.) Computed Airspeed (CAS), Source Analog AC Voltage ARINC-565 No. 3 output Accuracy, ± 2 Knots (40mv) or 10% of output, whichever is greater with respect to Synchro No. 1 from 100 to 450 Knots. Range 50 to 450 Knots Index Reference 0VAC at 350 Knots with signal and reference voltages in phase at speeds in excess of the index reference and 180 at speeds below 350 Knots. Scale Factor 20 millivolts per Knot with excitation of 26.000 VAC. Impedance Transformer isolated, 10,000 ohms ADC 26VAC reference common to Vertical Speed. Vertical Speed Source AC Tachometer (or equivalent) Accuracy 5% of indicated best straight line, or 30 feet per minute, whichever is greater. Range 0 to ± 20,000 feet per minute. Index Reference: in-phase for increasing altitude, out-of-phase for decreasing altitude. Scale Factor 250 millivolts per 1,000 feet per minute of altitude rate into a load impedance of 5,000 ohms resistive. ADC 26VAC Reference common to Computed Airspeed Static Air Temperature Source DC Amplifier having the circuit Lo side grounded with the reference voltage return input must be isolated to prevent ground loops. Accuracy ± 1.0 C Range -99 C to + 50 C Scale Factor Esat/Eref = 0.012087 * SAT, SAT in degrees Kelvin Impedance 10,000 ohms Reference Voltage 20 ± 2 VDC at 10,000 ohms True Airspeed Source AC Voltage Ratio, AC Transformer or equivalent. ARINC-565 No. 1 output. Accuracy ± 4 Knots or 2.5% Range 100 Knots to 599 Knots Index Reference 100 Knots Scale Factor 46.6 Knots per Volt ± 1% Impedance 10,000 Ohms Reference Voltage 11.8 ± 10 VAC at 10,000 ohms QNH Source DC Voltage Ratio Accuracy 1% Range 0 to 100% Index Reference 20V Page 7

vi. SPECIFICATIONS (cont.) Output Parameters ARINC-429 Specification Altitude: Label: 203-204 dependent on discrete select input Rate: 65mSec max Accuracy: 10 feet of the input Range: -1000 feet to 50,000 feet min Resolution: 4 feet Significant Bits 16 binary data, 1 sign Index: 2 feet (Direct conversion from synchro input.) Sel - Altitude: Label: 102 (can round to 100 foot) Rate: 65mSec max Accuracy: 10 feet of the input Range: -1000 feet to 50,000 feet min Resolution: 4 feet Significant Bits 15 binary data, 1 sign Index: 1 feet (Pressure Altitude - Altitude error.) Mach: Label: 205 Rate: 125mSec max Accuracy: 0.001 Mach of the input Range: 0.1 to 1 Mach Significant Bits 16 binary data Index: 0.0000625 Mach (Direct conversion from synchro input.) Computed Air Speed: Label: 206 Rate: 125mSec max Accuracy: ±2 of the input Range: 50 Knots to 450 Knots Significant Bits: 11 binary data Index: 0.5 Knots (Direct conversion from AC Analog input.) Altitude Rate: Label: 212 Rate: 65mSec max Accuracy: ± 32 ft/min. to 1000 ft/min, of the input ± 50 ft/min. at 2000 ft/min, of the input ± 150 ft/min. at 4000 ft/min, of the input ± 300 ft/min. at 6000 ft/min, of the input Range: 0 feet to ± 6,000 feet/min. Significant Bits 11 binary data, 1 sign Index: 16 feet/min. (Direct conversion from AC Analog input.) Page 8

vi. SPECIFICATIONS (cont) ARINC-429 Output Specification (cont.) True Air Speed: Label: 210 Rate: 125mSec max Accuracy: ± 2 kts of the input Range: 100 Knots to 599 Knots Valid: NCD < 135 Knots Significant Bits: 12 binary data Index: 0.5 Knots (Direct conversion from AC Analog input.) Static Air Temperature: Label: 213 Rate: 500mSec max Accuracy: ±1 C of the input Range: -99 C to 50 C Significant Bits: 9 binary data, 1 sign Index: 1 C (Direct conversion from DC Analog input.) QNH Baro-Correction: Label: 215 (Not Used) Rate: 125mSec max Accuracy: 1% Range: 0.0000-1.000 Valid: NCD, No input on current A/C Significant Bits: 15 (Bit 28 = MSB) (Designed to work with external or internal Reference, conversion from DC Analog.) Page 9

vii. MAJOR COMPONENT Equipment Supplied: 1ea. Model ADCU-500, Part Number 02050001 Equipment Required But Not Supplied: 1 ea. 2 MCU Mounting Tray, AEI, P/N: A10000-102C. Connector: ARINC-600, P/N BKAE1-120-30001. Wiring Harness Interconnect cable as required. Air Data Computers BENDIX HONEYWELL 3757183-1 193925-1 3757183-2 193925-2 3757183-3 193925-3 3757183-5 HG480C1 AND HG480C2 Flight Management Systems CMA-900 P/N 100-601900-402 ARINC-565 Fine/Coarse Synchro Altitude ADCU, P/N 02050001 Selected Altitude ARINC-565 Synchro MACH TO Linear AC CAS ARINC-429 Linear AC V/S DIGITAL Linear AC TAS Linear DC SAT ARINC-429 BUS 1 Linear DC QNH 5 Valid Flags Label Select ARINC-429 BUS 2 ARINC-429 FLIGHT MANAGMENT SYSTEM LABEL 203 * LABEL 102 LABEL 205 LABEL 206 LABEL 212 LABEL 210 LABEL 213 LABEL 215 *(LABEL 204, Label Select) INTERCONNECT BLOCK DIAGRAM (Illustration vii-1) Page 10

viii. ENVIRONMENTAL QUALIFICATION FORM NOMENCLATURE: ARINC 565/575 TO ARINC 429 MODEL / PART NO: ADCU-500, P/N 02050001 MANUFACTURE S SPECIFICTION; NONE MANUFACTURE: SKYLIGHT AVIONICS ADDRESS: 38629 6 th STREET EAST, PALMDALE, CA. 93550-3717 RTCA/DO-160D, Change 2, Dated, June 12, 2001 DATE TESTED: TBD Conditions Section Description of Conducted Tests Temperature and Altitude 4.0 Equipment tested to Category D2 Auxiliary air cooling not required. Temperature Variation 5.0 Equipment tested to Category B Humidity 6.0 Equipment tested to Category A Operational Shock and Crash Safety 7.0 Equipment tested to Category B operational and crash safety Vibration 8.0 Equipment tested Category T, Zone 2, Curves B,B1,R Explosion 9.0 Category X no test required Waterproofness 10.0 Category X no test required Fluids Susceptibility 11.0 Category X no test required Sand and Dust 12.0 Category X no test required Fungus 13.0 Category X no test required Salt Spray 14.0 Category X no test required Magnetic Effect 15.0 Equipment tested to Category Z Power Input 16.0 Equipment tested to Category Z Voltage Spike 17.0 Equipment tested to Category A Audio Frequency 18.0 Equipment tested to Category Z Susceptibility Induced Signal 19.0 Equipment tested to Category Z Susceptibility Radio Frequency 20.0 Equipment tested to Category RR Susceptibility Radio Frequency 21.0 Equipment tested to Category M Emission Lighting, Multiple Stroke & Multiple Burst 22.0 Equipment tested to Category XXE3 (M.S. 1MHZ) (M.B. 10MHZ) Lighting Direct Effects 23.0 Category X no test required Icing 24.0 Category X no test required Electrostatic Discharge 25.0 Equipment tested to Category A Remarks: Compliance to FAR Part 25 demonstrated by component parts and material analysis. Environmental tests will be conducted at: ENVIRONMENT ASSOCIATES, INC 9604 VARIEL AVE. CHATSWORTH, CA. 91311 Page 11