Features 1. Low operation current 2. High reliability 3. Low divergence angle 4. Standard optical power output:200mw (CW) 5. TO-56 (ψ5.6mm) Packaged, with Pb-free window cap. Applications 1. Motion sensor 2. Medical application 3. Pumping source for solid state laser 4. Infrared illumination 5. Industrial application External dimensions(unit : mm) No.156, Gaoshih Rd., Yangmei Township, Taoyuan County 326, Taiwan (R.O.C.) TEL: 886-3-485-2687 FAX : 886-3-475-4378 E-mail: sales@uocnet.com Website:http://www.uocnet.com 1 / 5 Ver.15
Absolute Maximum Ratings(Tc=25 ) Parameter Symbol Rating Unit Optical Output Po 220 mw Reverse Voltage Vr 2 V Operating Temperature(Case) Top -10~+50 Storage Temperature Tstg -40~+85 Electrical and Optical Characteristics(Tc=25 ) Parameter Symbol Condition Min. Typ. Max. Unit Threshold Current Ith Po=200mW - 55 - ma Operating Current Iop Po=200mW - 230 250 ma Operating Voltage Vop Po=200mW - 1.8 2.0 Volt Slope Efficiency η Po=50-150mW 0.95 1.1 - mw/ma Monitir current Im Po=200mW 0.4 2 ma Beam Divergence Parallel θ // Po=200mW - 6.5 - deg. (FWHM) Perpendicular θ Po=200mW - 28 - deg. Lasing Wavelength λ Po=200mW 805 808 811 nm θ // and θ are defined as the angle within which the intensity is 50% of the peak value. Typical characteristic curves Optical Output Power (mw) 260 240 220 200 180 160 140 120 100 80 60 40 20 0 Optical Output Power v.s. Forward Current 25 o C 40 o C 50 o C 60 o C 70 o C 85 o C 0 25 50 75 100 125 150 175 200 225 250 275 300 325 Forward Current (ma) 2 / 5
Forward Voltage v.s. Forward Current Forward Voltage (V) 2.0 1.5 0.5 25 o C 40 o C 50 o C 60 o C 70 o C 85 o C 0.0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 Forward Current (ma) 830 Peak Wavelength v.s. Case Temperature Peak Wavelength (nm) 825 820 815 810 805 800 Relative Intensity 0.8 0.6 0.4 0.2 Po=200mW Tc=25 o C Far-Field Pattern Perpendicular Parallel 0.0-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 Angle (degree) 3 / 5
Monitor Current (ma) 0.50 Tc=25 o C 0.40 0.30 0.20 0.10 Monitor Current v.s. Optical Output Power 0.00 0 20 40 60 80 100 120 140 160 180 200 Optical Output Power (mw) Slope Efficiency (mw/ma) 1.6 1.4 1.2 0.8 0.6 Slope Efficiency v.s. Case Temperature 100 Threshold Current v.s. Case Temperature Threshold Current (ma) 10 4 / 5
Precautions QUALITY ASSURANCE After any processing of laser chip or laser diode TO-CAN (LD) by the customer, the performance, yield and reliability of the product, in which the chip or LD is applied, are subject to change due to customer s handling, assembly, testing, and processing. Because laser chip and LD are strongly affected by environmental conditions, physical stress, and chemical stresses imposed by customer that are not in Union Optronics Corp. (UOC) control and hence no guarantee on the characteristics and the reliability at all after the shipment. Also, UOC does not have any responsibility for field failures in a customer product. When attaching a heat sink to laser chip or LD, be careful not to apply excessive force to the device in the process. SAFETY PRECAUTIONS Although Union Optronics Corp. (UOC) keeps improving quality and reliability of its laser chip and laser diode TO-CAN (LD), semiconductor devices in general can malfunction or fail due to their intrinsic characteristics. Hence, it is required that the customer s products are designed with full regard to safety by incorporating the redundancy, fire prevention, error prevention so that any problems or error with UOC laser chip or LD does not cause any accidents resulting in injury, death, fire, property damage, economic damage, or environmental damage. In case customer wants to use UOC laser chip or LD in the systems requiring high safety, customer is requested to confirm safety of entire systems with customer s own testing. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. The information provided by Union Optronics Corp. (UOC), including but not limited to technical specifications, recommendations, and application notes relating to laser chip or laser diode TO-CAN (LD) is believed to be reliable and accurate and is subject to change without notice. UOC reserves the right to change its assembly, test, design, form, specification, control, or function without notice. 5 / 5