Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Similar documents
Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

27/04/2015

Type Nominal voltage (V) Code HSV V

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC


Energy Management Energy Meter Type EM110

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Zelio Control Measurement Relays

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-MFS.21

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication.

Electronic timer CT-TGD.22

Energy Management Compact Power Transducer Type CPT-DIN Basic version

Energy Management Energy Meter Type EM110

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Modular Smart Power Transducer Type SPT-90

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Electronic timer CT-SDD.22

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Liquid level monitoring relay CM-ENS.2x

Solid-state Timer H3DS

Relay modules, Relay sockets, Plug relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

08/07/2015

Power analyzers and Energy Meters Power Analyzer Type WM14-96

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

02/11/2015

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

05/09/2012

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Electronic timers CT-S range Selection and ordering details

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Type CP-S, CP-C & CP-A Switch mode

02/11/2015

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Energy Management Compact Power Transducer Type CPT-DIN Advanced version

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

02/11/2015

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

38 Series - Relay interface modules A

PART NUMBERING SYSTEM

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

38 Series - Relay interface modules A

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

Three-phase monitoring relay CM-PFS

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

38 Series - Relay Interface Modules A

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

02/11/2015

Three-phase monitoring relays

02/11/2015

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Transcription:

Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes DC0, PC0 DC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring relay (DC0) Selection of measuring range by DP-switches Adjustable current and voltage on relative scale Adjustable hysteresis on relative scale Separately adjustable delay functions (0. to 30 s) Programmable latching or inhibit at set level Output: or x 8 A SPD relay N.D. or N.E. selectable For mounting on DN-rail in accordance with DN/EN 50 0 (DC0) or plug-in module (PC0) 45 mm Euronorm housing (DC0) or 36 mm plug-in module (PC0) ED indication for relay(s), alarm and power supply ON Galvanically separated power supply Product Description DC0 and PC0 are precise RMS AC/DC over+under, over+over or under+under current and voltage (selectable by DP-switch) monitoring relays. DC0 can perform also DC plus/minus measurement by short circuiting pins and Y. he devices can be connected to the M or MP and A8 or E8 current transformers. Both relays have two individual set levels with their own time delay. Only for DC0 each set level can work with a single SPD relay. Owing to the built-in latch function, the ON-position of the relay output can be maintained. nhibit function can be used to avoid relay operation when not desired (maintenance, transitions). he ED's indicate the state of the alarm and the output relays. Ordering Key Housing Function ype tem number Output Power supply Range DC 0 D B3 AV0 ype Selection Mounting Output Supply: 4 VDC Supply: 48 VDC Supply: 4/48 VAC Supply: /30 VAC DN-rail xspd DC 0 D 4 AV0 DC 0 D 48 AV0 DC 0 D B48 AV0 DC 0 D B3 AV0 Plug-in SPD PC 0 C 4 AV0 PC 0 C 48 AV0 PC 0 C B48 AV0 PC 0 C B3 AV0 nput Specifications nput Current level Voltage level DC levels (DC0 only) DC0: erminals Y, PC0: erminals 6, DC0: erminals Y, PC0: erminals 5, Connecting terminals, Y Current ranges nternal resis. Max. curr. 0.5 to 5 ma AC/DC 50 Ω 35 ma to 0 ma AC/DC 50 Ω 55 ma -5 to 5 ma DC (DC0 50 Ω 35 ma -0 to 0 ma DC } only) 50 Ω 55 ma Max. current for s 00 ma Voltage ranges nternal resis. Max. volt. 0. to V AC/DC > 0 kω V to 0 V AC/DC > 0 kω 0 V 0.4 to 4 V p AC > 0 kω 00 V - to VDC (DC0 > 0 kω V -0 to 0 VDC } only) > 0 kω 0 V Max. voltage for s 00 V C ranges AAC rms Max. curr. M and MP ranges (0.4 to 4 V p input) -ph.: 3-ph.: M 5 MP 3005 0.5 to 5 A 0 AAC M 0 MP 300 to 0 A 50 AAC M 00 MP 300 0 to 00 A 0 AAC M 500 MP 3500 50 to 500 A 50 AAC A8 ranges ( to 0 ma input) A8-0/0.5 to A 30 AAC A8-0/0 50 5 to 50 A 60 AAC A8-0/0 00 0 to 00 A 0 AAC A8-0/0 0 to 0 A 300 AAC A8-0/0 500 50 to 500 A 600 AAC E8-0 ranges ( to 0 ma input) E8-0.5 to A 50 AAC E8-0 50 5 to 50 A 00 AAC Note: he input voltage cannot raise over 300 VAC/DC with respect to ground (PC0 only) Specifications are subject to change without notice (0..0)

DC0, PC0 nput Specifications (cont.) Note: MP 3... current transformers not suitable for under current measurements due to the output signal of the device (see data sheet) Contact input DC0 erminals, Y PC0 erminals 8, 9 Disabled > 0 kω Enabled < 500 Ω atch disable > 500 ms Output Specifications Output or x SPD relays Rated insulation voltage 0 VAC Contact ratings (AgSnO ) Resistive loads AC 8 A @ 0 VAC DC 5 A @ 4 VDC Small inductive loads AC.5 A @ 0 VAC DC 3.5 A @ 4 VDC Mechanical life 30 x 0 6 operations Electrical life 0 5 operations (at 8 A, 0 V, cos ϕ = ) Operating frequency 00 operations/h Dielectric strength Dielectric voltage kvac (rms) Rated impulse withstand volt. 4 kv (./50 s) Supply Specifications Power supply Overvoltage cat. Rated operational voltage (EC 60664, EC 60038) through terminals: A, or, (DC0), 0 or, 0 (PC0) 4: 4 VDC ± 0%, insulated 48: 48 VDC ± 0%, insulated B48: 4/48 VAC ± % 45 to 65 Hz, insulated B3: /30 VAC ± % 45 to 65 Hz, insulated Dielectric voltage DC supply AC supply Supply to input kv 4 kv Supply to output 4 kv 4 kv nput to output 4 kv 4 kv Rated operational power AC 5 VA DC 3 W General Specifications Power ON delay Reaction time Alarm ON delay Alarm OFF delay Accuracy emperature drift Delay ON alarm Repeatability ndication for Power supply ON Alarm ON Output relay ON Mode of Operation DC0 and PC0 monitor both AC and DC current and voltage. DC0 can also monitor positive and negative DC voltage connecting terminals Y and. Example (no contact input - under+over voltage - x SPD N.D. relays s ± 0.5 s or 6 s ± 0.5 s (input signal variation from -0% to +0% or from +0% to -0% of set value) < 00 ms < 00 ms ( min warm-up time) ± 000 ppm/ C ± 0% on set value ± 50 ms ± 0.5% on full-scale ED, green ED, red (flashing Hz during delay time) or x ED(s), yellow ( x SPD for PC0) - RMS) DC0: One relay operates when the voltage drops below the under voltage set point for delay time. t releases when the voltage exceeds the set level plus the set hysteresis. he other relay operates when the voltage exceeds Environment (EN 6059) Degree of protection P 0 Pollution degree 3 (DC0), (PC0) Operating temperature -0 to 60 C, R.H. < 95% Storage temperature -30 to 80 C, R.H. < 95% Housing dimensions Din-rail version 45 x 80 x 99.5 mm Plug-in version 36 x 80 x 8 mm Weight Approx. 0 g Screw terminals ightening torque the over voltage set point for delay time. t releases when the voltage drops below the set level minus hysteresis. PC0: he relay operates when the voltage drops below the under voltage set level for set delay time or when it Max. 0.5 Nm acc. to EC 6094 Approvals, CSA (except 48) CE Marking Yes EMC Electromagnetic Compatibillity mmunity According to EN 6000-6- Emission According to EN 5008- exceeds the over voltage set level for more than the relative set delay time. he relay releases when the voltage exceeds the under voltage set level plus hysteresis and it drops below the over voltage set level minus hysteresis (the hysteresis is the same for both set levels). Specifications are subject to change without notice (0..0)

DC0, PC0 Mode of Operation (cont.) Example (latch active - under+under current - x SPD relays ( x SPD for PC0) - RMS) DC0: Each relay operates and latches when the current drops below the respective set level for delay time. Provided that the current has exceeded the respective set level plus hysteresis, each relay releases when the contact input s connection is interrupted. PC0: he relay operates when the current drops below the higher set level for delay time. Provided that the current has exceeded the higher set level plus hysteresis the relay releases when the contact input s connections is interrupted. Note Different delay times can be used for appropriate reaction according to the set points. Example 3 (inhibit active - over+over current with M C - DPD relay (SPD for PC0) - RMS) Provided that the contact input s connection is interrupted, the relay operates when the current flowing in the M C exceeds the lower set level for more than the respective delay time. t releases when the current drops below the lower set level minus hysteresis or when the contact input s pins are connected. (inhibit active - over+over current with A8-0 C - Function/Range/evel and ime Delay Setting Adjust the input range setting the DP switches and of the main black selector as shown below. Select the desired function setting the DP switches 3 to 6 of the black selector and, of the small red selector as shown below. o access the DP switches Set Point (SP) monitoring function ON: Over current or voltage OFF: nder current or voltage Relay(s) coupling ON: x SPD (DC0 only) OFF: x DPD (DC0, PC0) open the grey plastic cover as shown below he selection between current and voltage is automatically selected through the input connectors. RMS or positive/negative DC monitoring selectable by short-circuiting terminals Y and (DC0 only). DPD relay ( x SPD for PC0) - RMS Provided that the contact input s connection is interrupted, the relay operates when the current flowing in the A8-0 C exceeds the lower set level for more than its delay time. t releases when the current drops below the lower set level minus hysteresis or when the contact input s pins are connected. Example 5 (DC0 only) (no contact input - under+over voltage - x SPD N.D. relays - plus/minus DC One relay operates when the voltage drops below the under voltage set point for delay time. t releases when the voltage exceeds the set Selection of level, time delay and hysteresis: pper knob: Setting of hysteresis on relative scale: 0 to 30% on set value. level plus the set hysteresis. he other relay operates when the voltage exceeds the over voltage set point for delay time. t releases when the voltage drops below the set level minus hysteresis. n this case the spare front label has to be placed on the device for proper level adjustment. Note When the inhibit contact is opened, if the input signal is already in alarm position, the delay time needs to elapse before relay(s) activation. Centre knobs: Current level setting on relative scale: 0 to 0% on full scale. ower knobs: Setting of delay on alarm time on absolute scale (0. to 30 s). Measuring range (depending on connections) SW ON ON OFF Connect nput term. SW OFF ON ON None DC0: Y, 0.5 to 5 ma to 0 ma None PC0: 5, AC/DC AC/DC Y to DC0: Y, -5 to +5-0 to +0 None ma DC ma DC None DC0: Y, 0. to V 4 V p to 0 V PC0: 6, AC/DC AC/DC Y to DC0: Y, - to + None -0 to +0 V DC V DC Relay(s) working mode ON: Normally De-energized (ND) OFF: Normally Energized (NE) Power ON delay ON: 6 s ± 0.5 s OFF: s ± 0.5 s Contact input ON: atch function OFF: nhibit function Set Point (SP) monitoring function ON: Over current or voltage OFF: nder current or voltage Specifications are subject to change without notice (0..0) 3

DC0, PC0 Wiring Diagrams Example 4/48 4 VDC VDC (+) (+) Example Y A 5 6 0 Example atch/inhibit Example atch/inhibit Y A 5 6 0 Example 3 M... atch/inhibit Y Example 3 atch/inhibit A M... 5 6 0 atch/inhibit A8-0 Y Yellow Red A A8-0 Yellow Red atch/inhibit 5 6 0 Black Black Example 5 Y A DC0 PC0 4 Specifications are subject to change without notice (0..0)

DC0, PC0 Operation Diagrams Over+over voltage/current - N.D. relay(s) Over+over voltage/current - atch - N.D. relay(s) atch ON Set evel Set evel Set evel Set evel RE(DC0) RE(DC0) RE(DC0) DPD(DC0)/RE(PC0) RE(DC0) Red ED ON DPD(DC0)/RE(PC0) Red ED ON Over+under voltage/current - N.E. relay(s) Over+under voltage/current - nhibit -- N.E. N.E. relay(s) Set evel nhibit ON Set evel Set evel RE(DC0) RE(DC0) DPD(DC0)/RE(PC0) Red ED ON Set evel RE(DC0) RE(DC0) DPD(DC0)/RE(PC0) Red ED ON nder+under voltage/current - N.D. relay(s) Set evel Set evel RE(DC0) RE(DC0) DPD(DC0)/RE(PC0) Red ED ON Specifications are subject to change without notice (0..0) 5