Pega 345 Queen with Fanuc 04PC User Pre-installation Guide

Similar documents
Pega 357 with Fanuc 04PC User Pre-installation Guide

Pega 367 with Fanuc 04PC User Pre-installation Guide

Vipros 357 User Pre-installation Guide

Vipros 357 Queen User Pre-installation Guide

Pega 367 with 04PC Control Layout Drawings

EM2510 with AMNC-F User Pre-installation Guide

Vipros 357 Queen Machine Programming Limits

Free Standing Pedestal Mounting Installation Manual

18000 HDL FOUR POST LIFT LB CAPACITY INSTALLATION AND OWNER'S MANUAL

MODEL T28000 HEAVY-DUTY MOBILE BASE INSTRUCTIONS

Bolt Together Pump/Screw Together Frame Conversion Kit

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

Vipros 255 Machine Programming Limits

Installation and Leveling Instructions for Micro/Level Wedge Style Isolators

Safe and secure Dero

LORON SERVICE MANUAL / PARTS LIST SINGLE DOUBLE PALLET HANDLER CONTENTS: PAGE 1 Lift Truck Requirements General Installation Procedures

SPIDA SAW OPERATIONS MANUAL

INSTRUCTION SHEET. PIECE INVENTORY - MOBILE BASES Refer to the diagram for part identification.

Operating, Servicing, and Safety Manual Model " Foot Shear CAUTION: Read and Understand

AR-15 Armorer s Essentials Kit. Product # Instructions # Revision: B

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Important Notice. caution: Use proper lifting equipment and correct procedures to avoid injury.

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

Connect Transit Shelter

Portable System Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

Loading Dock Safety Gate

Sales & Service. JFK - Just For Kids. sasportonline.com. 135 Forestview Road 7879 Will Rogers Blvd.

Phone #: (360) Online Tech Support: Web:

ELECTRIC SLIP ROLL MACHINE. Model: ESR-1300X2.5/ESR-1300X4.5 ESR-1550X3.5/ESR-1580X2.0

121PB - PRO UNEVEN BARS

Installation of Balustrade Systems

HD installation guide

MODEL 83 Pail Handler

ATTENTION. 4. Do not over tighten the hydraulic fittings. This will cause leakage and will not be covered under warranty.

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

NEW VALID VT-1000 VERTICAL LATHE

Next Level Security. This 2-tier locker ships flat to save on freight, comes in galvanized and powder coat finish options, and has a modular design.

College of Forestry 610: Power Tools

OWNER'S MANUAL TIE ROD, WALL & FLOOR MOUNTED JIBS. Model JIB-HC, JIB-LC, JIB-FM

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA MANUAL PART NUMBER:

installation guide

NRS Installation Manual

12 TON HYDRAULIC SHOP PRESS. Instruction Manual. Please read this instruction manual carefully before use.

Axial Movement. Tailstock 2,000 RPM MAXIMUM SPINDLE SPEED AUTOMATIC LUBRICATION SYSTEM 15 HYDRAULIC CHUCKING SYSTEM EXTRA WIDE Z AXIS DESIGN OF 620MM

Assembly Instructions

TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

REVIEW ALL INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING INSTALLATION

Installation Manual for Gate Guard

PORTABLE PULLER 55 Ton Capacity

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

INSTALLATION INSTRUCTIONS, AND PARTS LIST

VARIABLE SPEED WOOD LATHE

EMB MANUFACTURING INC.

MAKO EC EXTENDED CABINET

1. VERIFY ALL COMPONENTS

MODEL T TON HYDRAULIC PRESS INSTRUCTIONS (For Machines Mfd. Since 10/17)

SHBP10M HYDRAULIC PRESS WITH MANDRELS

Universal flat-panel mount

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

PHTM100 - Phantom 100 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 25 lbs with 100mm or 75mm Mounting Patterns

PREPARATION & TOOL CHECK LIST

BISON GOOSENECK FOOTBALL 1 PAIR OF GOAL POSTS

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

ASSEMBLY AND CARE INSTRUCTIONS JUST FOR KIDS 355

Universal flat-panel mount

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL STORAGE SHED MODELS: STOR-96-G-W-1RH & STOR-912-G-W-1RH

LCD DISPLAY MOUNT

Installation Instructions for. Before You Begin TOOLS REQUIRED

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

OPERATING INSTRUCTIONS 3421UX VETERANS BLVD, CARLSTADT, NJ 07072

Assembly Instructions for model: VMPR1

The DeltaGrip System. Safety and Operating Instructions. Trigger. Air Supply Connection. Handle Assembly. Air Line Assembly.

Assembly Instructions for Model: VMPR1

VERTICAL PLATFORM LIFT

Barn Door & Hardware Installation Guide

ROCK DRILLS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Dual Arm Tilt LCD Mount

GENUINE PARTS INSTALLATION INSTRUCTIONS

HOW TO LEVEL A PRESS USING A PRECISION MACHINISTS LEVEL

ROUND TOP RV SHELTER

Installation Instructions for Vista Air Vertically Folding Walls

Cyclone Upcut Cut off saw

southpaw enterprises, inc.

Operators Manual: Diamond Rock Saw Excavator Attachment Austramac Flashcut Series

USER MANUAL & PARTS LIST MODEL 136A S/N:

Micro Compound Lever Briquette Press Parts List, Notes, Drawings & Assembly Designed using dimensioned lumber size 40 mm x 100 mm

MAHLE CBP-10 / CBP-10A & CSP-10 / CSP-10A. Operation Manual Shop press

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

Rayport G Eco Dealer Kit

Preference Slimline 5536 Utility Console

Transcription:

Pega 345 Queen with Fanuc 04PC User Pre-installation Guide Amada America Inc. 7025 Firestone Blvd. Buena Park CA. 90621 Phone: (714) 739 2111 Fax.: (714) 739 4099 Email info@amada.com Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 35

Warning! Qualified personnel must complete all work.! Do not apply power to the Pega 345 Queen until an A.E.S.I. (Amada Engineering and Service Incorporated) Engineer is present and has instructed you to do so.! Considerable effort has been made to ensure that this manual is free of inaccuracies and omissions. However, as we are constantly improving our product, some of the data contained herein may not exactly reflect the latest revisions to the Pega 345 Queen. If in doubt concerning a specific item, please contact your local Amada America sales person for clarification, or check our Internet site, http://www.amada.com for the latest release of this document. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 35

Contents Introduction...5 Specifications - Motion Package...6 Specifications - Punching System...6 Turret Configuration - 44 Station - 2 Auto-Index...7 Turret Configuration - 58 Station - 2 Auto-Index...8 Specifications - Fanuc 04PC Controller...9 Supply Requirements - Electrical...10 Optional Equipment...10 Installing the Electrical Power Supply...11 Supply Requirements - Pneumatic...12 Optional Equipment...12 Installing the Pneumatic Supply...12 Planning the Location of the Pega 345 Queen...13 Moving the Pega 345 Queen...13 Plan View - Pega 345 Queen...14 Plan View - Pega 345 Queen with P345hs left side conveyor...15 Plan View - Pega 345 Queen with P345hs conveyor and MP1225 loader...16 End View - Pega 345 Queen...17 Elevation View - Pega 345 Queen...18 Foundation Requirements...19 Foundation Anchoring Procedure...20 Foundation J-bolt Detail...20 Plan View - Foundation Pega 345 Queen...21 Elevation - Foundation Pega 345 Queen...21 Machine Anchoring Requirements...22 Saw Cut J-bolt Mounting Holes...22 Core Drill J-bolt Mounting Holes...23 Foundation / Floor J-bolt Mounting Procedure...24 Drilled Hole with Anchor Rod and Adhesive Mounting Holes...26 Drilled Hole with Anchor Rod and Adhesive Mounting Procedure...27 Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 35

Removing the Protective Coating...29 Machine Leveling...30 Rocking Test...30 Floor Condition: Crowned...31 Floor Condition: Sloped...32 Leveling Procedure...33 Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 35

Introduction This manual describes the tasks that the purchaser of a Pega 345 Queen must complete before calling A.E.S.I. (Amada Engineering and Service Incorporated) to complete the installation and operator training. An overview of the preparations is as follows:! Plan the location of the Pega 345 Queen taking into account the Recomended Safety and Maintenance areas indicated on the plan view. See page 13, Planning the Location of the Pega 345 Queen.! Prepare the Pega 345 Queen floor or foundation as required. See page 19, Foundation Requirements, for details.! Uncrate the Pega 345 Queen and place on the foundation, but do not fill the anchor-bolt holes (if used) until after A.E.S.I. completes the initial installation.! Install the electrical supply. See page 10, Supply Requirements - Electrical, for details.! Install the pneumatic supply. See page 12, Supply Requirements - Pneumatic, for details.! Remove the protective coating from the surface of the Pega 345 Queen See page 29, Removing the Protective Coating, for details.! If additional equipment is to be installed, repeat the previous steps for each piece of additional equipment. Note: It is the purchaser s responsibility to install any safety devices to ensure the recommended safety area. Note: Considerable effort has been made to ensue that this manual is free of inaccuracies and omissions. However, as Amada America strives to continually improve our products, some data contained herein may not exactly reflect the latest revisions to the Pega 345 Queen. If in doubt concerning a specific item, please contact your local Amada America sales engineer for clarification. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 35

Specifications - Motion Package Travel Method X and Y axes work piece movement Control Method X, Y, T & C Drive Motors Fanuc AC Servo (X, Y, T, C) Maximum Sheet Size 40" (Y) x 100" (X) with one repositioning cycle. Additional support tables are required for material lengths greater than 50.0" Maximum Sheet Thickness 0.250" Maximum Material Weight 110 lb. Maximum Axis Travel 50.0" (X) by 40.0" (Y) Max. Table Speed ( X / Y / Combined ) 1,968 IPM / 1,968 IPM / 2,783 IPM Punching Accuracy ±0.004" Positioning Accuracy ±0.001" Repeatability ±0.001" Specifications - Punching System Press Capacity 33 Tons Press Stroke 1.259" Stroke Per Minute 350 Maximum Hit Rate 1 Centers 200 Maximum Hole Diameter 4.500" Tool Type Amada Thick Turret Turret Rotation Speed 30 RPM Feed Clearance 0.787" Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 35

Turret Configuration - 44 Station - 2 Auto-Index B 216 B A 328 326 C 225 127 223 124 A/I E 229 B 331 A 334 130 233 132 235 C A 338 237 136 B 340 139 141 This turret used on the following machine models Pega 344, 345Q, 345K, 357, 367 Coma 555, 557, 567, 588 Vipros 345, 357, 367 Vela II 355 B 342 D 215 1000mm Disc Thick 44 Station 2 Auto Index 243 D B 113 314 111 312 B 108 209 310 A C 207 A 104 205 102 306 303 B 201 E 152 155 253 354 356 B A/I 244 B 251 C A AUTO INDEX A B C D E B MAXIMUM SIZE ROUND ½" 1¼" 2" 3½" 4½" 1¼" 12.7mm 31.7mm 50.8mm 88.9mm 114.3mm 31.7mm NUMBER OF STATIONS (KEYED) 18 (6) 16 (16) 4 (4) 2 (2) 2 (2) 2 (2) Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 35

340 239 138 141 342 143 244 345 246 147 248 349 150 351 Pega 345 Queen with Fanuc 04PC User Pre-installation Guide Turret Configuration - 58 Station - 2 Auto-Index 318 217 116 152 253 354 219 315 A/I 220 114 313 212 331 228 111 210 309 230 208 129 107 333 306 132 105 336 235 134 102 203 304 237 1000mm disc 58 STATION 2 AUTO INDEX 201 170 271 168 372 369 165 266 264 367 A/I 256 255 AUTO INDEX This turret used on the following machine models PEGA 345, PEGA 345 King, PEGA 357, PEGA 367 B A C D E B COMA 555, COMA 557, COMA 567, COMA 588 VIPROS 345, VIPROS 357, VIPROS 367 VIPROS 357 Queen, VIPROS 367 Queen MAXIMUM SIZE ROUND 1/2" ( 12.7mm ) 1 1/4" ( 31.7mm ) 2" ( 50.8mm ) 3 1/2" ( 88.9mm ) 4 1/2" ( 114.3mm ) 1 1/4" ( 31.7mm ) NUMBER OF STATIONS ( KEYED ) 12 ( 12 ) 36 ( 12 ) 4 ( 4 ) 2 ( 2 ) 2 ( 2 ) 2 ( 2 ) Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 35

Specifications - Fanuc 04PC Controller Model Control Function Input Method Minimum Command Unit Minimum Travel Unit Operating Modes Display Modes Interlock Displays Fanuc 04PC X, Y, T & C MDI, DNC, Paper Tape 0.001" (X, Y).01 0 (C) 0.001" (X, Y).01 0 (C) Automatic, MDI & Manual Program Contents, Position Information, Program Check, Parameters, Tool Hit Counter, Self Diagnostics Oil Temperature, Oil Pressure, Door Open Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 35

Supply Requirements - Electrical Pega 345 Queen Optional Equipment P345hs Conveyor MP1225 Loader 230 / 460 / 3 / 60 ±10%, 18 kva 46 amps @ 230 / 3 / 60 VAC* 23 amps @ 460 / 3 / 60 VAC* 208 / 230 / 460 3ph ±10%,.8 kva 2.1 amps @ 208 / 3/ 60 VAC* 2.0 amps @ 230 / 3 / 60 VAC* 1.0 amps @ 460 / 3 / 60 VAC* 200 / 3 / 60 ±10%, 10 kva 29 amps @ 200 / 3 / 60 VAC* To operate at 230 / 460 VAC a step up transformer with the following service is required 26 amps @ 230 / 3 / 60 VAC* 13 amps @ 460 / 3 / 60 VAC* * The actual supplied electrical service must be sized to allow for starting current of approximately 150% of this value. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 10 of 35

Installing the Electrical Power Supply The Pega 345 Queen requires one electrical power source. The Pega 345 Queen should be supplied from a power line separate from those for welding machines or other machines that produce electrical noise.! The Pega 345 Queen electrical inlet is 64" above floor level at the left side of the Fanuc 04PC control.! For the location of required electrical supplies for optional equipment, please see the installation guides for the specific equipment. Pega 345 Queen left side of electrical enclosure Pega 345 Queen power conection inside of electrical enclosure Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 11 of 35

Supply Requirements - Pneumatic Pega 345 Queen Optional Equipment MP1225 Loader 80 psi @ 8.8 ft³/min. 75 psi @ 31.8 ft 3 /min. Installing the Pneumatic Supply The Pega 345 Queen requires connection to a compressed air system by hose or pipe. The compressed air must be clean and dry. Please note the following:! The minimum pipe inside diameter is ½".! The air pressure required is 80 psi.! The air volume required is 8.8 ft³/min..! The air inlet is approximately 16" above the floor level at the rear of the Pega 345 Queen For the location of required air supplies for optional equipment, please see the installation guides for the specific equipment Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 12 of 35

Planning the Location of the Pega 345 Queen The following diagrams provide the details for positioning the Pega 345 Queen.! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 345 Queen.! All of the Recommended Safety / Maintenance areas should be used, but at a minimum, the doors of the Fanuc 04PC control must be able to be opened. Any reduction of the Recomended Safety / Maintenance areas may decrease personnel safety and increase time and expense of installation and maintenance.! The Pega 345 Queen and Fanuc 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heating sources such as infrared heaters have been shown to affect punch and die alignment. Moving the Pega 345 Queen Lifting or moving of the Pega 345 Queen should be done only by professional rigging companies well versed in the moving of large and heavy industrial machinery. Acceptable moving methods include, lifting by overhead crane, wheeled dollies beneath the machine feet, or adequately sized lifttruck forks beneath the machine frame. The Pega 345 Queen has a relatively high center of gravity and narrow footprint. Care must be taken to prevent inadvertent tipping of the machine while in motion. Machine Weight 12 tons. Lifting lugs front and rear of Machine Frame. Caution: Extremely Top Heavy Load 65.30" 12 tons Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 13 of 35

Plan View - Pega 345 Queen Electrical Requirements E1 Pega 345 Queen 230 / 460 / 3 / 60 ±10% 18 kva 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC Compressed Air Requirements 27.56" A1 Pega 345 Operator Control Station 80 psi @ 8.8 ft3/min. Power Supply 49.21" 04PC Control 12" 12" 12" Scale 310.84" Recomended Safety / Maintenance Area 40" From All Components 162.52" Pega 345 Queen Length 80" Maximum Travel Area 40" Material 58.47" 39.37" Work Range Y-axis Zero Optional Material Support Tables Required 19.10" 11.56" E1 45" Minimum 56" Maximum Pega 345Q Optional Material Support Tables Required 24.05" A1 55.12" 54.73" 109.85" Pega 345 Queen Width 200" Maximum Travel Area 100" Material 280.00" Recomended Safety / Maintenance Area 40" From All Components Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 14 of 35

Plan View - Pega 345 Queen with P345hs left side conveyor Electrical Requirements E1 Pega 345 Queen 230 / 460 / 3 / 60 ±10% 18 kva 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC E2 P345hs Conveyor 208-230 / 460 / 3 / 60 ±10%.8 kva 2.1 amps @ 208 / 3/ 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC Compressed Air Requirements A1 Pega 345 Operator Control Station 12" 12" 12" Scale 80 psi @ 8.8 ft3/min. 383.84" Recomended Safety / Maintenance Area 40" From All Components 162.52" Pega 345 Queen Length 80" Maximum Travel Area 40" Material 58.47" 24.05" 39.37" Work Range Y-axis Zero Optional Material Support Tables Required A1 19.10" 11.56" 49.21" E1 04PC Control 27.56" 45" Minimum 56" Maximum Pega 345Q Optional Material Support Tables Required 73.00" E2 P345hs 46.77" Access required this area for 55.12" 54.73" 109.85" Pega 345 Queen Width 200" Maximum Travel Area 100" Material 280.00" Recomended Safety / Maintenance Area 40" From All Components Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 15 of 35

Plan View - Pega 345 Queen with P345hs conveyor and MP1225 loader Electrical Requirements E1 Pega 345 Queen 230 / 460 / 3 / 60 ±10% 18 kva 46 amps @ 230 / 3 / 60 VAC 23 amps @ 460 / 3 / 60 VAC E2 P345hs Conveyor 208-230 / 460 / 3 / 60 ±10%.8 kva 2.1 amps @ 208 / 3/ 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC E3 MP1225 Loader 200 / 3 / 60 ±10%, 10 Kva To operate at 230 / 460 VAC a step up transformer with the following service is required 29 amps @ 200 / 3 / 60 VAC 26 amps @ 230 / 3 / 60 VAC 13 amps @ 460 / 3 / 60 VAC Compressed Air Requirements A1 Pega 345 80 psi @ 8.8 ft3/min. A2 MP1225 Loader Operator Control Station 12" 12" 12" Scale 75 psi @ 31.8 ft3/min. 383.84" Recomended Safety / Maintenance Area 40" From All Components 162.52" Pega 345 Queen Length 80" Maximum Travel Area 40" Material 58.47" 39.37" Work Range 24.05" Y-axis Zero Optional Material Support Tables Required A1 19.10" 11.56" 49.21" 04PC Control E1 27.56" 0.06 mm Pega 345Q A2 45" Minimum 56" Maximum MP1225 Xformer E3 Optional Material Support Tables Required MP1225 Material Load Position 122.11" 67.52" 189.63" MP1225 Length E2 P345hs MP1225 Forklift access required this area for material / parts loading / unloading Access required this area for slug removal 55.12 54.73" 55.73" To Edge Of MP1225 109.85" Pega 345 Queen Width 200" Maximum Travel Area 100" Material 141.74" MP1225 Width 377.46" Recomended Safety / Maintenance Area 40" From All Components Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 16 of 35

End View - Pega 345 Queen 79.88" 111.00" 35.12"* Material Pass Line 29.53" 37.99" 12" 12" 12" Scale 54.72" 109.84" 55.12" *Dimension will change with installed options Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 17 of 35

Elevation View - Pega 345 Queen 47.24" Throat Depth 39.37" Work Area 62.99" 79.89" 35.12"* Material Pass Line Floor Line 33.47" 27.95" 9.84" 11.02" 7.99" 33.47" 27.56" 87.60" 162.52" 12" 12" 12" Scale Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 18 of 35

Foundation Requirements The Pega 345 Queen does not require a special foundation to perform as expected, however there are minimum requirements that an existing floor must meet in order to assure machine reliability and tool life. If the existing floor does not meet the following minimum requirements, plans for a recommended foundation are given on page 21, Plan View - Foundation. The minimum acceptable floor conditions to assure a successful installation are:! The area of the floor where the machine frame is to be located must be a single, homogeneous slab in good condition. There must be no cracks or other signs of deterioration of the floor.! The floor must be 4" to 6" thick.! The floor must be capable of supporting 3.5 tons/ft².! The floor must be level to 0.032"/ft. If the existing floor meets the minimum requirement list above, it must still be inspected carefully when the anchor-bolt holes are cut. Voids under the floor, or wetness (not associated with the hole cutting procedure) should be considered signs of an inadequate floor and a new machine location or new foundation must be considered. It is the customer s responsibility to determine that the floor meets these minimum requirements. Placing the machine on an inadequate, cracked floor, or straddling seams in a floor may be grounds for voiding the machine warranty! Amada America Inc. does not recommend the use of vibration isolating mounts under the machine feet, as these devices have been shown to increase the vibration within the machine frame, increasing the likelihood of vibration related problems. Solid leveling devices are acceptable provided they incorporate a means of anchoring the machine to the floor with the supplied J- bolts or alternative anchoring method. Special Note: This document details several methods of anchoring the Pega 345 Queen to a new foundation or an existing floor. These methods are designed to install the Pega 345 Queen as a stand-alone machine using the supplied anchor bolts and base plates. Installation or use of additional options such as leveling pads or material handling systems may dictate other methods of anchoring or foundation design not shown in this document. Before committing to a specific method of anchoring the Pega 345 Queen, confirm that the chosen method is compatible with all purchased optional items and planned expansion. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 19 of 35

Foundation Anchoring Procedure An ideal foundation is given on the following pages. This foundation must be used if the existing floor cannot meet the minimum requirements to support the machine. The foundation must consist of a single, homogeneous slab. The foundation must be level to within 0.032" / ft. Anchoring the Pega 345 Queen to the floor using the anchor-bolts supplied is essential to ensure reliable performance. Amada generally recommends that the foundation have a minimum load bearing capacity of 3.5 ton/ft 2. It is the purchaser s responsibility to determine that the foundation meets these requirements. Please note the following:! The base plates, shims, anchor bolts, nuts, and washers are shipped with the Pega 345 Queen.! The concrete J-bolt pads should be filled after the machine is placed on the foundation.! See special note page 19 Foundation J-bolt Detail See page 24, Foundation / Floor J-bolt Mounting Procedure, for proper method of mounting the Pega 345 Queen on the foundation. A Base Plate Machine Frame Hole in Foundation Machine Foot A Machine Foot Base Plate Floor Line Supplied J-Bolt 24" 4.4" 8.0" 15.8" A 5" 10" Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 20 of 35

Plan View - Foundation Pega 345 Queen 30" 87.60" 30" 48" M42 x 630 Anchor Bolt 29.63" 48" 14.76" Pega 345 Queen Centerline New Foundation Existing Floor Elevation - Foundation Pega 345 Queen M42 x 630 Anchor Bolt 24" 8" Cement Sand Stone 1 : 2 : 4 New Foundation Crushed Stone Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 21 of 35

Machine Anchoring Requirements Saw Cut J-bolt Mounting Holes To maintain machine reliability, extend tool life, and remain level over an extended period the Pega 345 Queen must be anchored in place on an adequate floor or foundation. At a minimum the floor must consist of a single, homogeneous slab, level to within 0.032"/ft², and capable of supporting 3.5 tons/ft². It is the purchaser s responsibility to determine that the floor meets these minimum requirements. This machine mounting method should be used only if the floor is of such quality that it will support the weight of the machine with the anchor J-bolts used only for maintaining the location of the machine. Please note the following:! The base plates, shims, anchor bolts, nuts, and washers are shipped with the Pega 345 Queen.! The concrete J-bolt pads should be filled after the machine is placed on the foundation. A Base Plate Machine Frame Saw Cut Hole In Existing Floor Machine Foot A! See special note page 19 87.60" M42 x 630 Anchor Bolt Machine Foot Existing Floor Base Plate 29.63" 14.76" Pega 345 Queen Centerline Saw Cut Hole (4) Supplied J-Bolt 24" Existing Floor 4.4" 8.0" 15.8" A 5" 10" Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 22 of 35

Core Drill J-bolt Mounting Holes To maintain machine reliability, extend tool life, and remain level over an extended period the Pega 345 Queen must be anchored in place on an adequate floor or foundation. At a minimum the floor must consist of a single, homogeneous slab, level to within 0.032"/ft², and capable of supporting 3.5 tons/ft². It is the purchaser s responsibility to determine that the floor meets these minimum requirements. This machine mounting method should be used only if the floor is of such quality that it will support the weight of the machine Machine Foot with the anchor J-bolts used only for maintaining the location Base Plate of the machine. Machine Frame Please note the following:! The base plates, shims, anchor bolts, nuts, and washers are shipped with the Pega 345 Queen.! The concrete J-bolt pads should be filled after the machine is placed on the foundation.! See special note page 19. 87.60" A 10" Core Drill in existing floor A M42 x 630 Anchor Bolt 34.21" 29.63" 14.76" Pega 345 Queen Centerline 10" Core Drill Hole (4) Machine Foot Floor Line Base Plate Existing Floor Supplied J-Bolt 24.0" 10.0" A Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 23 of 35

Foundation / Floor J-bolt Mounting Procedure Step 1. Saw cut or Core drill a hole in the existing floor and remove the underlying dirt to the required 24" depth. See Floor J-bolt Mounting Hole Plan View (saw cut hole) or Alternative J-bolt Mounting Method Plan View (Core Drill) for correct layout dimensions of the four anchor holes required. Step 2. Set base plate over the hole. Step 3. Set the machine on the base plate. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 24 of 35

Step 4. Set the J-bolt through the hole in machine foot, attach washer and nut to hold J-bolt in place. Step 5 Pour the Concrete. Ensure that the J-bolt remains correctly aligned to the machine frame during the pouring and hardening time of the concrete. Ensure that the concrete level is equal to the floor level Step 6. To complete the mounting procedure, level the machine frame by inserting leveling shims between the machine foot and base plate. See Leveling the Machine section for correct procedure. Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 25 of 35

Drilled Hole with Anchor Rod and Adhesive Mounting Holes To maintain machine reliability, extend tool life, and remain level over an extended period the Pega 345 Queen must be anchored in place on an adequate floor or foundation. At a minimum the floor must consist of a single, homogeneous slab, level to within 0.032"/ft², and capable of supporting 3.5 tons/ft². It is the purchaser s responsibility to determine that the floor meets these minimum requirements. This machine mounting method should be used only if the floor is of such quality that it will support the weight of the machine with the anchor J-bolts used only for maintaining the location of the machine. Please note the following:! The base plates, and shims, are shipped with the Pega 345 Queen. Machine Foot Base Plate! The Anchor Rods not supplied with the Pega 345 Queen and must be ordered separatly Machine Frame! See special note page 19. 87.60" 1¼" Drilled Hole (4) 29.63" 14.76" Pega 345 Queen Centerline 1" x 16" anchor bolt Machine Foot Existing Floor Floor Line Existing Floor 6.00" Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 26 of 35

Drilled Hole with Anchor Rod and Adhesive Mounting Procedure Step 1. Drill the four Anchor Rod holes in the existing floor. The holes should be drilled approximately 6 deep. See Alternative Floor Bolt Mounting Method Plan View (Drilled Hole with Adhesive Anchor Rod) for correct layout dimensions. Existing Floor Step 2. Set the Amada Machine Leveling Plates over the drilled holes Existing Floor Step 3. Step 4 Set the machine on the machine leveling plates. Level the machine frame by adjusting the Amada machine leveling plates. See Leveling the Machine section for correct procedure. Existing Floor Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 27 of 35

Step 5 Fill each of the Anchor Rod holes to within 2 inches of the floor surface with the Adhesive compound. Do not overfill. Existing Floor Step 6 Attach the hex nut and flat washer on the Anchor Rod and place the Anchor Rod into the drilled hole. Using a twisting motion to move the Anchor Rod through the epoxy compound, seat the flat washer and hex nut against the top of the machine foot. Existing Floor Step 7 Step 8. Allow the Adhesive to harden for 24 hours. Tighten the 4 hex nuts. Existing Floor Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 28 of 35

Removing the Protective Coating The Pega 345 Queen must be thoroughly cleaned of protective coating. The sheet metal guards can be removed from around the turret to allow cleaning of the upper and lower turrets, tool bores and die holders. Please note the following:! Remove wrapping paper from the X and Y-axes ball screws, then remove the protective coating.! Remove the wrapping paper from the X and Y LM guides then remove the protective coating, make sure that you remove the paper from both sides of the carriage.! Clean die holders one at a time. Remove a die holder, clean and replace it before removing the next die holder. If the die holders are mixed up, serious turret alignment problems may occur.! A suitable solvent should be used to remove the protective coating. Y AXIS BALL SCREW UPPER AND LOWER TURRETS Y AXIS LM GUIDES (1 EACH SIDE) X AXIS BALL SCREW X AXIS LM GUIDES (TOP AND BOTTOM) Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 29 of 35

Machine Leveling Proper Machine leveling is critical to the Pega 345 Queen performing as designed. Materials and tools required: Supplied with the machine: Assorted thickness machine leveling shim stock Anchor bolts Supplied by AESI service: Spirit level capable of reading 0.0005"/ft One (1) 12 ton hydraulic bottle jack Not supplied: Additional shim stock of 0.005" thickness may be required to achieve a properly leveled machine. Rocking Test After the machine frame has been leveled the use of the following G-code is necessary to determine that the machine frame is properly leveled and balanced. Should the machine frame vibrate or move excessively during the rocking test the machine frame must be re-leveled using the procedure in this manual. Should the proper leveling technique not eliminate the excessive frame motion, consideration must be given to relocation of the machine or replacement of the existing floor with an adequate foundation. Repeat test with X-axis movement values of 0.500", 1.000", and 4.000" G92X50.000Y39.370 N1 G91G70X-.25Tttt(Use any valid tool number) G70X.25 M97P1 G50 Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 30 of 35

Floor Condition: Crowned The flatness of the floor plays an important step in the leveling procedure of the machine. To properly level the machine the weight bearing points must be as far from the centerline of the machine frame as possible. Should a condition known as crowning exist the weight bearing points of the machine may not be far enough from the machine centerline to ensure a stable machine. Under these conditions, a procedure known as Half-Shimming should be used. Machine centerline Crowned Floor Machine Foot Base Plate Weight Bearing Point Base Plate To move the weight bearing points further from the machine centerline the use of half-shims of.125" thick on top of the base plate as shown is recommended. After the half-shims are installed and the machine frame is leveled, use the rocking test to determine that the machine frame is stable enough to allow production without damaging the machine. Under extreme conditions the use of half-shims may not move the machine weight bearing points far enough from the machine centerline to ensure the machine frame is stable. Under these conditions, a more suitable location must be found for the machine, or a new foundation for the machine will be necessary. Crowned Floor Machine Foot Base Plate Machine centerline Base Plate Weight Bearing Point Half-shim Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 31 of 35

Floor Condition: Sloped The slope of the floor plays an important step in the leveling procedure of the machine. To properly level the machine the weight bearing points must be as far from the centerline of the machine frame as possible. Should the floor slope excessively the weight bearing points of the machine may not be far enough from the machine centerline to ensure a stable machine. Under these conditions, a procedure known as Half-Shimming should be used. Machine Foot Base Plate Machine centerline Weight Bearing Point Sloped Floor Base Plate Shim To move the weight bearing points further from the machine centerline the use of half-shims of.125" thick on top of the base plate and leveling shims as shown is recommended. After the half-shims are installed and the machine frame is leveled, use the rocking test to determine that the machine frame is stable enough to allow production without damaging the machine. Under extreme conditions the use of half-shims may not move the machine weight bearing points far enough from the machine centerline to ensure the machine frame is stable. Under these conditions a more suitable location must be found for the machine, or a new foundation for the machine will be necessary. Machine Foot Base Plate Machine centerline Shim Weight Bearing Point Sloped Floor Base Plate Half-shim Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 32 of 35

Leveling Procedure 1. Determine the high end of machine frame by placing the spirit level on the turret to measure the level of the machine frame in the y- axis. 2. Use the bottle jack to lift the low end of the machine frame. 3. With the turret end of the machine frame slightly higher than the carriage end. Shim beneath both machine feet and the base plates until the machine frame measures near level on the y-axis. Shim Equaly Both Sides Bottle Jack 4. Center the bottle jack under the carriage end of the machine frame. 5. Lift the machine frame until all weight is off the machine feet at the carriage end of the machine frame. Lift the machine frame as little as possible to take the weight off the base plates. Remove weight of machine from base plates Bottle Jack Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 33 of 35

6. With the machine supported on the bottle jack at the carriage end of the machine frame and the machine feet at the turret end of the machine frame, place the spirit level on the turret. 7. Measure and record the level of the turret in the x-axis direction. 8. Lower the machine frame to place all machine feet in contact with the leveling shims and base plates. 9. Lift the turret end of the machine frame to allow shimming between the machine feet and base plates to level the machine frame in the x-axis direction. 10. Repeat steps 5 to 9 until the machine frame measures level to 0.0005"/ft in step 7, then continue. Shim to level X-axis Bottle Jack 11. With the weight of the carriage end of the machine supported by the bottle jack. Monitor the level of the turret in the x-axis, as the bottle jack is slowly lowered to place the carriage end machine feet in contact with the base plates. 12. Any change in the level indicates that the carriage end of the machine needs to be leveled. Remove weight of machine from base plates Bottle Jack 13. Lift the carriage end of the machine frame to allow shimming between the machine feet and base plates to level the carriage end of the machine frame in the x-axis direction. 14. Repeat steps 11 and 13 until no difference in level is noted when the machine weight is on or off the base plates and shims, then continue. Shim to level X-axis Bottle Jack Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 34 of 35

15. With all of the machine feet setting on the shims and base plates place the spirit level on the turret to measure and note the level of the machine frame in the y-axis. 16. Using the bottle jack lift the low end of the machine frame and shim equally under both machine feet to level the machine frame in the y-axis. 17. Repeat steps 15 to 16 until the machine frame measures level to 0.0005"/ft in the y-axis then continue. 18. Run the machine using the rocking test G-code to determine that the machine frame is leveled adequately. Should excessive movement of the machine frame be noticed check for the conditions discussed in Floor Condition Crowned and Floor Condition Sloped 19. Tighten the anchor bolt nuts to prevent the machine frame from moving when in use. Monitor the machine level while tightening the anchor bolts to assure the machine level is not changed. Shim Equaly Both Sides Bottle Jack Print Date 02/28/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 35 of 35