Quick Reference Guide

Similar documents
Diagnostic Ultrasound System. Operation Note

M7Vet Diagnostic Ultrasound System. Operation Note

4 Working With Scan Modes

S S S2 Operation Manual

ACUSON X150 Knobology & User Guide

DC-6. Diagnostic Ultrasound System

DC-6 Expert. Diagnostic Ultrasound System

M5 Diagnostic Ultrasound System

Vevo770 Ultrasound. Quick Operation Guide

Ultrasound Diagnostic Scanner INSTRUCTION MANUAL

Planmeca Romexis. quick guide. Viewer EN _2

User Manual Veterinary

IDEXX-PACS * 4.0. Imaging Software. Quick Reference Guide

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E

Copyright 2014 SOTA Imaging. All rights reserved. The CLIOSOFT software includes the following parts copyrighted by other parties:

Digital Portable Overhead Document Camera LV-1010

ZView ver.2 DR Console Software. User Manual. (for HUMAN) Manual Version : 2.1 Revision : 002

IMPAX 6 DISPLAY TOOL LIST

QUICK GUIDE

This document contains work instructions related to utilizing the dental imaging application, XrayVision DCV, version and above.

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

SPECTRALIS Training Guide

This document contains work instructions related to utilizing the dental imaging application, XrayVision DCV, version and above.

ImagesPlus Basic Interface Operation

Revosoft Operators Manual

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

Photoshop CC Editing Images

4.0 How to Turn On the Selenia Dimensions

Copyright Notice. Trademarks

Nikon View DX for Macintosh

Progeny Imaging Veterinary

Windows INSTRUCTION MANUAL

Vivid i Ultra-Portable Echo System

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Apple Photos Quick Start Guide

KODAK Dental Imaging Software. Quick Start Guide

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

OPERATING INSTRUCTIONS

Progeny Imaging. User Guide V x and Higher. Part Number: ECN: P1808 REV. F

INSTRUCTION MANUAL MM-A209

Version 2 Image Clarification Tool for Avid Editing Systems. Part of the dtective suite of forensic video analysis tools from Ocean Systems

OzE Field Modules. OzE Studio Series. OzE Studio OzE Studio Lite. Quick reference pages OzE Studio Data Entry (2pgs) OzE Preview.

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

USER GUIDE EDIT OBJECTS

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

Design Your Performance

12. Creating a Product Mockup in Perspective

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

Introduction. Introduction

ZONARE. z.one pro Ultrasound System. Instructions for Use. (Including Special Procedures interface option)

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

Table of Contents 1. Image processing Measurements System Tools...10

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

3D Viewer. user's manual _6

Introduction to Autodesk Inventor for F1 in Schools (Australian Version)

Chapter 4 Adding and Formatting Pictures

Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane

Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.

Introduction. Introduction

DOCUMENT SCANNER INSTRUCTIONS. Space. Backup. Count Only. New File. Scanner. Feeding Option Manual Auto Semi-Auto

Digital Design and Communication Teaching (DiDACT) University of Sheffield Department of Landscape. Adobe Photoshop CS5 INTRODUCTION WORKSHOPS

OzE Field Modules. OzE School. Quick reference pages OzE Main Opening Screen OzE Process Data OzE Order Entry OzE Preview School Promotion Checklist

Imaging Features Available in HTML5. it just makes sense

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

CHROMACAL User Guide (v 1.1) User Guide

Micro-Image Capture 8 Installation Instructions & User Guide

Installation & User Manual Micro-Image Capture 7

Multipurpose Color Ultrasound System IMAGING SYSTEMS

Version 4.2 For WINDOWS

QAM Snare Navigator Quick Set-up Guide- Wi-Fi version

STRIKER Series. Owner s Manual

Tutorial 2: Setting up the Drawing Environment

Overview... 1 Displaying the Item Processing Modules Window... 1

MC3 Motion Control System Shutter Stream Quickstart

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

5 Masks and Channels

Brightness and Contrast Control Reference Guide

ISCapture User Guide. advanced CCD imaging. Opticstar

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

Next Back Save Project Save Project Save your Story

Software Starter Guide

reference guide reference guide reference guide

TOPAZ LENS EFFECTS QUICK START GUIDE

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania

Operating Manual. (Version 3.10)

Users Guide. Meditory CORPORATION. Version 2015C v1.0 7/20/2015

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

ScanGear CS-U 6.0. for CanoScan D646U Color Scanner. User s Guide

Creating Digital Stories for the Classroom

Getting Started. with Easy Blue Print

Microscopy from Carl Zeiss

Deceptive Jamming Using Amplitude-Modulated Signals

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide

R2009/R3016 Radar system Quick Reference Card

SKF TKTI. Thermal Camera Software. Instructions for use

Photo/Image Controls

ArcSoft PhotoImpression Table of Contents:

CONTENTS. Chapter I Introduction Package Includes Appearance System Requirements... 1

HP Photosmart Mz60 series Digital Camera. User Guide

Transcription:

siemens.com/nx3 Quick Reference Guide ACUSON NX3 Series

Contents 2 System Overview 3 Getting Started 8 2D Mode and M-mode 12 Color and Spectral Doppler 24 Measurements and Calculations 38 Text, Arrows and Pictograms 48 Data and Image Management 54

System Overview 3 Control Panel 1. Power ON / OFF (QuikStart Standby Mode) 2. Patient Study Controls 3. User-defined Keys 4. Soft Key Rotary Controls 5. Alphanumeric Keyboard 6. Text, Arrows and Pictograms 7. Major Modes 8. Angle, Steer, Select 9. TGO Image Optimization 10. DCG Controls 11. Depth, Zoom, Focus 12. UD (User-defined Key), Dual 13. Print, Store and Clip 14. Freeze 15. Home Base Controls 2 1 5 3 4 7 6 8 9 15 10 14 11 12 13 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler 1 Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

System Overview 4 Home Base Area 1. Left Set 2. Right Set 3. Update / View 4. Escape 5. Caliper 6. Trackball (CINE review) 7. Wrist Support 1 4 3 6 5 2 7

Status Icons 5 1. Select Key 2. Update Key 3. Trackball 4. Escape Key 5. Caps Lock 6. Wireless Connection 7. Insert / Overwrite 1 2 3 4 5 6 7 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

System Overview 6 Connecting Transducer In the unlocked position, insert the transducer into the port located on the front of the system. Turn the lock clockwise until it locks into place.

Wheel Locks 7 Unlocked (wheels can swivel and roll). Locked (wheels cannot swivel and roll). System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Getting Started 8 Patient Registration New Patient 1. Press New Patient 2. Enter patient information. TIP Transducer can also be selected from the Touch Screen (if 3 or more transducers are connected to the system) after patient registration or by selecting Exam on the Control Panel. 3. Select the Transducer and Exam type and select OK.

Edit Study 9 1. Press 2. Use the keyboard to edit patient information. 3. Select OK to save. Patient Registration Worklist 1. Press New Patient 2. Enter patient information to search. 3. Select Worklist at the upper left side of the form -- Select US (Ultrasound) Search -- Select the study and press Select -- Select OK to begin the study. System must be connected to a HIS / RIS server to access patient worklist. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Getting Started 10 Transducer / Study Control Panel and Touch Screen Exam 1. Select or 4. Select the transducer on the Touch Screen. 2. Select a transducer from the upper left menu on the image screen. 3. To change transducers during an exam, press Exam or the user-defined key assigned to the transducer. TIP Selection of transducers via the Touch Screen is available once three or more transducers are connected.

Store, Print, Review and End Exam 11 Review Select 1. Press to acquire and save the clip. 2. Press Freeze to freeze the clip / image frame. 3. If desired, roll trackball for frame-by-frame CINE review. -- Press to save a static image. -- Press to save and print. TIP Starting a new patient also ends a current exam. 4. Press, then -- Press -- Rotate Select Select to view 1x1 format to move between images. 5. Press END on the keyboard to end the study. A compatible printer must be connected and assigned to the print function in the Presets menu before the print function becomes active. Print Store 1 and 2 are customized in the Presets menu. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 12 2D Control Panel Control Panel Controls 2D TGO (TGO Tissue Grayscale Optimization Technology) DGC Focus Function Brightness Mode Press to enter / exit 2D mode. Rotate to adjust overall 2D gain / brightness. One-button image optimization Press to optimize the overall image displayed. Press twice to deactivate. Manually adjusts gain / brightness at depth Default all slide controls in the center. Adjusts the focal zone Rotate to move up / down and press to activate multiple focal zones. Note: Only available with certain transducers.

Depth / Zoom HD Zoom Dual Adjusts the scanning depth and magnifies the image Rotate clockwise / counter-clockwise to increase / decrease depth. Press to activate zoom. Rotate to change region of interest (ROI) size and press to activate. Press again to exit zoom. Note: Zoom available in live or frozen images. Displays a high density zoom Press to activate. Rotate the Depth / Zoom to increase / decrease ROI. Press Depth / Zoom or HD Zoom to activate. Displays two separately acquired images side-by-side Press Dual to activate and toggle between images. Press the 2D key to exit. 13 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 14 2D Touch Screen Touch Screen Controls TGO Gain* Trapezoid 4B Image Presets* THI (Tissue Harmonic Imaging) Function Controls the TGO gain offset Select to adjust up / down. Note: TGO must be active to adjust. Displays linear or trapezoid image format Select to activate / deactivate. Available on linear transducers only. Defaults to SieClear 2 upon activation. Displays four separately acquired images Select to activate and add each image. Note: Available on live image only in 2D and Color Doppler. Image optimization presets Select to view available image presets. Customizable in a user-defined exam only. Increases contrast and lateral resolution. Reduces noise and clutter. Select to activate / deactivate.

SieClear (SieClear Multi-view Spatial Compounding)* and AdvSieClear (Advanced SieClear Spatial Compounding)* Edge* RS (Resolution / Speed)* DTCE (Dynamic TCE Tissue Contrast Enhancement Technology)* Enhances contrast resolution and boundary detection Increase for more compounding. Decrease for less compounding. Settings are transducer and mode dependent. Sharpens the contours of a structure Increase for more sharpness. Decrease for less sharpness. To deactivate, select zero. Balances line density (spatial resolution) and frame rate Increase to improve image detail. Decrease to improve frame rate. Reduces speckle and enhances tissue contrast Settings are Low, Medium and High. Note: Available on live or frozen images. 15 *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 16 2D Touch Screen Touch Screen Controls Split DTO (DTO Dynamic Tissue Optimization Technology) ClarifyVE (Clarify Vascular Enhancement (VE) Technology) ClarifyVE Levels* Function Activates two simultaneous images in dual format Select to activate / deactivate. Activates level of gain compensations. Reduces bright whites. Increase to reduce whites. Decreases artifacts, increases contrast resolution and boundary detection in structures with flow Press to activate / deactivate. Note: Available on live imaging only. Adjusts levels of sensitivity when using ClarifyVE Rotate clockwise to increase sensitivity. Rotate counterclockwise to decrease sensitivity. Select a higher level to increase. Select a lower level to decrease. Note: Available on live imaging only.

Persist (Persistence)* U/D Flip (Up / Down flip) R/L Flip (Right / Left flip) Clip Capture >> Frame averaging determines the number of frames combined into the final image Increase for more frame averaging. Decrease to demonstrate motion. To deactivate, select 0. Note: Available only on live image when SieClear is set to Off. Adjusts orientation on image screen Select to switch between orientations [up(u) or down(d) and right(r) or left(l)]. Note: Available on live or frozen image. Selects type of clip capture Chronology: Prospective, Retrospective. Acquisition Rate: Normal, High. Trigger Type: Time Capture, Beat Capture, Rwave Capture. 17 *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 18 2D Soft Keys Soft Key Controls P (Transmit Power) DR (Dynamic Range)* MultiHertz (MultiHertz Multiple Frequency Imaging) Function Adjusts acoustic energy delivered to the patient Rotate clockwise to increase power. Rotate counterclockwise to decrease power. Changes Mechanical (MI) and Thermal (TIS, TIB) Indices. Adjusts number of gray shades displayed Rotate clockwise for a softer / grayer image. Rotate counterclockwise to increase contrast. Note: Available on live or frozen images. Balances between resolution and penetration Use higher frequency to increase resolution. Use lower frequency to increase penetration.

Map Tint Rotate Processing curves that assign echo amplitudes to gray shades Maps A I are from low to high contrast. Maps 1 3 are customizable maps (Modify Map). Note: Available on live or frozen images. Colorizes the grayscale image Press and rotate for tints from 0 15. Note: Available on live or frozen images. Adjusts image orientation in 90 degree increments Rotate to adjust. 19 *Configurable for the touch screen controls and/or soft rotary keys. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 20 M-mode Control Panel Control Panel Controls M (M-mode) Update / View Color M-mode Function Enters / exits M-mode and adjusts overall M-mode gain Press to activate / deactivate. Roll the trackball to position the M-mode cursor. Rotate to adjust overall M-mode gain. Alternates between 2D / M-mode formats on the Touch Screen Press to move between modes. Enters / exits color M-mode With Color Doppler activated, press M (M-mode). Place cursor and Press M. Press M to exit. Note: Only available with cardiac transducers.

M-mode Touch Screen 21 Touch Screen Controls Full M Sweep Speed* Edge* Function Changes the display format to full M-Mode Press to activate / deactivate. Note: Available on live or frozen image. Adjusts the scrolling speed of the M-mode sweep Increase to display less cardiac cycles. Decrease to display more cardiac cycles. Note: Available on live or frozen image. Sharpens the contours of a structure in the M-mode sweep Increase for more sharpness. Decrease for less sharpness. To deactivate, select 0. *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

2D Mode and M-mode 22 M-mode Soft Keys Soft Key Controls MultiHertz (frequency) Maps Tint DR (Dynamic Range)* Function Adjusts Frequency for 2D image and M-mode strip Rotate clockwise to increase resolution. Rotate counterclockwise to increase penetration. Processing curves that assign echo amplitudes to gray shades in the M-mode sweep Map choice is displayed from low to high contrast. Note: Available on live or frozen image. Colorizes the M-mode sweep Press and rotate for tints from 0 15. Note: Available on live or frozen image. Adjusts number of gray shades displayed in the M-mode sweep Rotate clockwise for a softer / grayer sweep. Rotate counterclockwise for increased contrast. Note: Available on live or frozen image. *Configurable for the touch screen controls and/or soft rotary keys.

23 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 24 Color Doppler Control Panel Control Panel Controls C (Color Doppler) Power (Power Doppler) Color Box Size / Position Steer Function Enters / exits color Doppler or adjusts overall color Doppler gain Press to activate / deactivate color Doppler mode. Rotate to increase / decrease color Doppler gain. Applies colors based on flow amplitude Select Power to activate / deactivate. Rotate to increase / decrease power Doppler gain. Adjusts the color ROI Increase frame rate by decreasing the color ROI width or depth. Press Set to alternate between Size / Position. Roll the trackball to resize or reposition color ROI. Steers the Color ROI Toggle the Steer key left / right to steer. Note: Steering Angle is transducer dependent. Available only on linear transducers.

Color Doppler Touch Screen 25 Touch Screen Controls Flow* Invert RS (Resolution / Speed)* Function Flow state optimization presets Choices are Low, Medium, High. Select desired preset to optimize flow state. Reverses the colors depicting forward and reverses flow in the color ROI and the color bar Select to activate / deactivate. Note: Available on live or frozen image. Balances line density (spatial resolution) and frame rate Increase for image detail. Decrease to increase frame rate. *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 26 Color Doppler Touch Screen Touch Screen Controls Smooth* Persistence* Filter* Function Adjusts spatial averaging (smoothing) for color flow Increase for flow sensitivity. Decrease for color spatial resolution. Adjusts the time that the color flow data remains in the ROI before being replaced by another color Increase for greater vessel color fill. Decrease to increase temporal resolution. Adjusts the color wall filter Increase to reduce motion artifacts. Decrease to increase sensitivity to low flow states.

Priority* Display Prioritizes the display of grayscale or color flow data Increase for greater vessel color fill. Decrease to prioritize grayscale and less vessel color fill. Turns color display off image when in Color Doppler Select to activate / deactivate. Note: Color ROI remains on image. 27 *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 28 Color Doppler Soft Keys Soft Key Controls MultiHertz (frequency) Maps P (Transmit Power) Function Adjusts the color Doppler frequency independent of the 2D frequency Rotate to increase / decrease. Selects a processing curve that assigns the velocity / velocity variance (for Color) or flow amplitudes (for Power) to a range of colors Maps choices are A I. Note: Available on live or frozen image. Acoustic energy delivered to the patient in color Doppler mode Increase / decrease to adjust the transmit power. Changes Mechanical and Thermal Indices displayed.

Scale Baseline Adjusts the pulse repetition frequency (PRF) Increase / decrease to adjust the PRF. Adjusts the range of flow velocities displayed above and below the baseline Move up / down to adjust the baseline of the active mode. 29 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 30 Spectral Doppler Control Panel Control Panel Controls D (pulsed wave) Doppler and CW (continuous wave) Doppler TGO (TGO Technology) Update / View Function Enters / exits spectral Doppler or adjusts overall spectral Doppler gain Press to activate / deactivate. Roll trackball to position Doppler gate. Press D or CW to activate the strip. Rotate to adjust overall spectral Doppler gain. One button optimization of spectral Doppler gain, baseline, and scale With Doppler spectrum active, press to activate. Press twice to exit TGO. Alternates between the Doppler spectrum and the 2D image Press to alternate between Doppler / 2D.

Steer Angle Adjusts the PW Doppler angle Toggle left / right to reverse the steering angle. Available only on linear transducers. Adjusts angle correction Press to cycle through 60 / 0 / 60 angle selections. Rotate to adjust values in 1 increments. Note: Available on live or frozen image. 31 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 32 Spectral Doppler Touch Screen Touch Screen Controls Triplex Gate* Invert Sweep* Function Enters / exits Duplex or Triplex mode Select to activate / deactivate Duplex / Triplex. Adjusts sample volume size Increase / decrease to adjust size. Reverses the Doppler spectrum (negative values display above the baseline) Select to activate / deactivate. Note: Available on live or frozen image. Adjusts the scrolling speed of the Doppler spectrum Increase to display less cardiac cycles. Decrease to display more cardiac cycles. Note: Available on live or frozen image.

Mute Full D Filter* Sensitivity* Update Rate* Mutes the Doppler audio Select to activate / deactivate. Displays Full Screen Doppler Select to activate / deactivate. Note: Available on live or frozen image. Adjusts the wall filter Rotate to adjust rejection of low frequency signals. Adjusts the sensitivity of the Trace tool when in Auto Stats Increase for higher sensitivity. Choices are 1 5. Defines the interval for refreshing the 2D-mode image Select Off, 1 sec, 2 sec, 4, sec, 8 sec or EOS (End Of Sweep). 33 *Configurable for the soft key rotary controls and/or touch screen user interface. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 34 Spectral Doppler Touch Screen Touch Screen Controls Auto Stats* DTI (DTI Doppler Tissue Imaging Capability) T/F Res* (Time / Frequency resolution) Function Automatic trace and display of PW Doppler measurements Select to activate / deactivate. Select settings for data above, below or on both sides of the baseline. Note: Available on live or frozen image. Activates the Doppler Tissue imaging feature for cardiac exams Press to activate / deactivate. Adjusts the balance between the temporal and frequency resolution of the Doppler spectrum Increase to increase temporal resolution. Decrease to increase frequency resolution. *Configurable for the soft key rotary controls and/or touch screen user interface.

35 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Color and Spectral Doppler 36 Spectral Doppler Soft Keys Soft Key Controls Baseline Scale DR (Dynamic Range)* MultiHertz (frequency) Function Adjusts the range of velocities displayed Increase / decrease to adjust the baseline. Note: Available on live or frozen image. Adjusts the pulse repetition frequency (PRF) Increase / decrease to adjust the PRF. Adjusts number of gray shades displayed Rotate clockwise for a softer / grayer spectrum. Rotate counterclockwise for a greater contrast spectrum. Note: Available on live or frozen image. Adjusts spectral Doppler frequency independent of the 2D or color frequency Increase / decrease to adjust.

Map Tint Selects a processing curve that assigns echo amplitudes to gray shades in the Doppler spectrum Select desired Map from A H. Note: Available on live or frozen image. Colorizes the Doppler spectrum Select desired Tint from 0 11. Note: Available on live or frozen image. 37 *Configurable for the touch screen controls and/or soft rotary keys. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Measurements and Calculations 38 Unlabeled Measurements Perform Measurement 1. Press 5. Roll the trackball to position the second caliper. 6. Press to complete the measurement. 2. Select the desired measurement type and Press Caliper. 3. Roll the trackball to position the first caliper. 4. Press to anchor TIP Unlabeled measurements do not enter into the exam report. Measurements can be performed on frozen, CINE and stored images

Labeled Measurements 39 1. Press 2. Roll the Trackball to select the desired Exam type and measurement label and press Set. 3. Roll the trackball to position the first caliper. 4. Press to anchor 5. Roll the trackball to position the second caliper. 6. Press to complete and send the labeled value(s) to the patient report. TIP The measurement label can be selected before or after calipers are placed. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Measurements and Calculations 40 Edit Measurements (Labeled and Unlabeled) Edit Completed Measurement 1. Press to activate calipers and cycle between active calipers. 2. Press on the Touch Screen to cycle between calipers sets. 3. Press on the Touch Screen or press the key to remove active measurement. Select 4. Push on the Touch Screen to delete all measurements. 5. Rotate Undo / Redo or the Select key to edit a trace measurement.

Reposition Measurement Results 41 1. Press 2. Rotate and to cycle through the available size and positions. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Measurements and Calculations 42 Report Review the Report Report 1. Press or on the Image screen to enter / exit report page. 2. Select a report heading for Data or Description. 3. Press Next to review additional measurements. 4. Select Send Report to send to connected external printer. 5. Press to store report as a thumbnail. 6. Select Return to exit the Report. 7. To edit the report, roll the trackball to the desired measurement and edit. 8. Press Summary to generate a revised Summary. Only labeled measurements appear on the report. An * appears for any edited measurement.

2 43 2 3 6 3 4 6 Touch Screen Image Screen System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Measurements and Calculations 44 Summary Review the Summary 1. Press to activate the measurement package. 2. Press Report to enter / exit report page. 3. Select on the Touch or Imaging Screen. 4. Select Export to USB to send to USB as a pdf file. 5. Select Print to print to a connected printer. 6. Select Exit to exit the Report.

3 45 4 5 6 Touch Screen Image Screen System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Measurements and Calculations 46 Summary Import Images into the Summary 1. Press to activate the measurement package. 2. Press Report to enter / exit report page. 3. Select on the Touch or Imaging Screen. 4. Select the Display format from the Summary Page. 6. Roll the trackball to the desired image location in the Image section and press the Set Key to drop the image in report. 7. To Delete the image, move the cursor over the image and press Delete Image 5. Roll the trackball to the thumbnail image and press the Set key to highlight. TIP Up to 20 images can be stored to the Summary.

47 4 5 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Text, Arrows and Pictograms 48 Text Icons Control Function Activates / deactivates text cursor and text Touch Screen menu. Sets default position for text cursor. Positions the cursor at the home location. Temporarily hides text. Deletes all text, pictograms or arrows. Deletes one line of text at the cursor.

Deletes the last word. 49 Inserts or overwrites text when text cursor is active. Displays the next or previous page, when available. Caps Lock System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Text, Arrows and Pictograms 50 Arrows 1. Press the Arrow or Text key on the keyboard. 2. Select the Arrow tab on the Touch Screen. 3. Roll the trackball to position. 4. Turn Rotate or turn Select to change arrow direction. 5. Rotate Arrow Size to adjust arrow size. 6. Press Set to anchor. 7. Press New or Select to add another arrow. 8. Press Delete to delete the last arrow. 9. Press Delete All to delete all arrows 10. Press Select Arrow or Update to cycle through multiple arrows. 11. Press Exit to exit Arrow function. TIP Unlimited arrows can be added.

2 51 3 4 7 10 8 9 11 6 5 3 9 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Text, Arrows and Pictograms 52 Pictograms 1. Select from the keyboard. 2. Select the desired pictogram from the Touch Screen. 3. Roll the trackball to position the transducer icon. TIP TIP Pictograms are customized in the Presets Menu by selecting Presets / Pictogram List. Pressing Clear Screen also deletes any text or measurements on the image. 4. Press the Select Rotate on the Touch Screen or rotate key to rotate the transducer icon. 5. Press to anchor. Delete 6. Press on the Touch Screen or on the keyboard to delete the Pictogram.

53 2 6 4 System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Data and Image Management 54 Review Images Review Images on Current Study Review Images from a Closed Study 1. Press and press Select and double-click a thumbnail. 2. Select or press display format. 3. Rotate the Select to change the key to view more images. 1. Select 2. Select a patient and press the key twice to open. 3. Select or press display format. to change the 4. Press or 2D to exit. 4. Rotate the images. Select key to view more 5. Press or 2D to exit.

Delete Images Restart an Exam 55 Delete Images from a Current Study or in Review 1. Press Select to activate cursor. 2. Select an image on the thumbnail panel to highlight. 3. Select located below thumbnail panel and answer prompt Yes to Delete. 4. Or, press 1. Select 2. Select exam from Local Disk. 3. Select located below the list of exams on the right to restart exam. 4. Patient data screen will populate, press OK to open study. 5. Press Select to activate cursor. 6. Highlight an image from the Imaging Screen 7. Press on the Touch Screen or from the imaging screen. 8. Answer the prompt Yes to Delete. TIP Images, clips and volumes can be added to a closed study within 24 hours. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Data and Image Management 56 Teaching File 1. Select 2. Select the exam from Local Disk. 3. Roll the trackball, highlight an image or clip and press the key. Repeat for all desired images. 4. Press on the Touch Screen. 5. Under Add Teaching File, name the file and press Close. 6. The teaching file is displayed in the Patient Browser. 7. To add images from multiple studies, follow steps 1 4, then select the desired teaching file. 8. Press to add the additional images. TIP Images and Clips stored in teaching file removes all patient data.

Export Studies 57 Export Study to DICOM Network 1. Select the patient name in the Patient Browser. 2. Under Network, select the desired Destination. 3. Select Send. Export Study to CD-R / DVD in DICOM 1. Insert CD-R / DVD. 2. Select the patient name in the Patient Browser. 3. Select Local Disk from the Drop Down under Export / Import. 4. Select CD / DVD and select DICOM as the export format and select Export. TIP Images automatically send to PACs if the system is configured to send during the exam or at the end of the exam. TIP Hold CTRL to select more than one patient name. A showcase DICOM viewer will be burned onto the CD-R or DVD with the patient data if selected in the Presets Menu (Presets / Archive / CD / DVD. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

Data and Image Management 58 Import / Export Studies Export Study to USB in PC Format (TIFF or AVI) 1. Insert USB. 2. Select the patient name in the Patient Browser. 3. Select USB and the Tiff / AVI export format. 4. Select Export. Import Study from CD-R / DVD to Local Database 1. Insert CD-R / DVD. 2. Select CD / DVD from Export / Import in the Patient Browser. 3. Select patient name on the CD / DVD. 4. Select Import.

Import Study from USB to Local Database 59 1. Insert USB. 2. Select USB from Export / Import in the Patient Browser. 3. Select patient name on the USB. 4. Select Import. System Overview Getting Started 2D Mode and M-mode Color and Spectral Doppler Measurements and Calculations Text, Arrows and Pictograms Data and Image Management

The products / features mentioned in this document may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. ACUSON NX3, Advanced SieClear, Clarify VE, DTI, DTO, Dynamic TCE, MultiHertz, SieClear and TGO are trademarks of Siemens Medical Solutions USA, Inc. Images used in this guide are for educational purposes only. They have been modified or compressed and may not reflect the actual image quality of the system. Siemens Healthcare Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen Germany Phone: +49 9131 84-0 siemens.com/healthcare Legal Manufacturer Siemens Medical Solutions USA, Inc. Ultrasound 685 East Middlefield Road Mountain View, CA 94043 USA Phone: +1-888-826-9702 siemens.com/ultrasound Order No. A91US-400-1C-4A00 Printed in Germany CC 3494 0416X. Siemens Medical Solutions USA, Inc., 2016 siemens.com/healthcare