Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Similar documents
Busbars and lines are important elements

Earth Fault Relay EFSPL-1A/5A

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

Current monitor Type C 551

Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213

3 Pole high impedance differential relay 7VH83

Deploying Current Transformers in Applications Greater Than 200 A

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

Earth Fault Protection

Enhanced Quality with a Touch of Style

Harmonic restraint earth fault or single-phase overcurrent protection

I -limiter The world s fastest switching device

IRI1-ER - Stabilized Earth Fault Current Relay

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Protective Relays Digitrip 3000

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Functional Range. Synchronising Relay : UN1, FN2, SY1, SY/SP. C&S Protection & Control Ltd.

Transformer differential protection RADSB

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

DIGITAL EARTH FAULT RELAY

STATIC EARTH FAULT RELAY

DEIF A/S. Insulation monitor. Type SIM-Q

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

XD1-T - Transformer differential protection relay

Power systems Protection course

DATA SHEET Differential current relays, RMC-131D ANSI code 87

Phase and neutral overcurrent protection

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

DIGITAL EARTH FAULT RELAY

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

N. TEST TEST DESCRIPTION

7PG21 Solkor Rf Feeder Protection Energy Management

Stabilized Differential Relay SPAD 346. Product Guide

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Transformer differential protection

Transformer Protection

Electrical Protection System Design and Operation

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

N. TEST TEST DESCRIPTION

SPAD 346 C. Stabilized Differential Relay. User s manual and Technical description SPAD 346 C V ~ V. f n SPCD 3D53 SPCJ 4D28

OPEN-PHASE DETECTION TECHNIQUES FOR CRITICAL STANDBY SUPPLIES

Substation applications

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Transformer Protection

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

2V68-S User Guide. CT Supervision And Shorting Relay. User Guide

MV network design & devices selection EXERCISE BOOK

Protection relays and transformers

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Back to the Basics Current Transformer (CT) Testing

Residual Current Operated Circuit-Breakers (RCCBs)

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Type VDG 13 Undervoltage Relay

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

CableTroll 2410 PN: /03. User Manual

Mounting Instructions / Manual MV1171

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

High Voltage Busbar Protection

Electrical Description

Protection of Electrical Networks. Christophe Prévé

Instantaneous Overcurrent Relay

Burdens & Current Transformer Requirements of MiCOM Relays. Application Notes B&CT/EN AP/B11. www. ElectricalPartManuals. com

Electronic relays. Monitoring. Monitoring

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

7PG23 5B3 Restricted Earth Fault Answers for energy

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

Protection components

SPECIFICATION FOR OVERCURRENT RELAYS

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

PD300. Transformer, generator and motor protection Data sheet

Automatic capacitor banks with detuned filters

Content. 1. Dimensiong of CT s. 2. Error definitions. 3. General design aspects. 4. Linear cores. Certified acc. to ISO 9001/14001, SN EN 45001

Installation / Monitoring Technique

SPAD 346 C Stabilized differential relay

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

EASUN REYROLLE LIMITED

COPYRIGHTED MATERIAL. Index

CAMTO. Arc detecting relay. system. January Revised August D D1200

TN, TT & IT Earthing Arrangements

Generator Protection GENERATOR CONTROL AND PROTECTION

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Protecting Large Machines for Arcing Faults

RARIC Shaft current protection

2 Grounding of power supply system neutral

MRS1 - Negative sequence relay. Manual MRS1 (Revision A)

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

Transcription:

Functional Range - Earth Fault Relay C&S Protection & Control Ltd.

2

Contents Page No. 1. Application 2. Operating Principle. Current Transformer Connections 5. Connections, Contact Arrangement and Setting Adjustments 7 5. Functional Check 8 6. Technical Data 9 7. Information Required with Order 11

1. Application The relay is a definite time relay suitable for earth fault protection of generators, motors, transformers, capacitor banks, shunt reactors and radial feeders in distribution networks. Examples of the application of non-directional earth fault protection using the relay type are shown below. Example : Back-up Earth Fault Proteciton With the earth fault relay type connected as shown in fig. it responds to any earth fault on the generator (or transformer) or on the network. In order to discriminate with other system earth fault protection the relay type must have a tripping delay time which is longer than all other system earth fault protection devices. Fig. Example 1: Generator Stator Earth Fault Protection. With the generator neutral point earthed as shown in Fig.1, the earth fault relay type responds only to phase-earth faults between the generator and the location of the current transformers supplying the relay. Earth faults beyond the current transformer, i.e. on the consumer or line side, will not be detected. Fig. 1 2. Operating Principle The earth fault relay type is a definite time over current relay with an additional low-pass filter. Fig. Relay characteristic Example 2 : System Earth Fault Protection. With the generator neutral point earthed as shown in Fig.2, the earth fault relay type responds only to earth faults in the power system connected to the generator. It does not respond to earth faults on the generator terminals or in the generator stator. Fig. 2 I E It comprises a current input circuit, an electronic current measuring circuit and a time delay unit. It also includes a low pass filter which blocks higher harmonic currents such as third, fifth, seventh etc. Third and triple harmonics (e.g. 9th, 27th etc.) are of particular importance when applying earth fault protection since these harmonics are additive and co-phasal in a three phase system and thus appear in the system neutral or in an earth fault relay as zero sequence (or earth fault) current. Such a current would be detected by an earth fault relay and may cause unwanted tripping. The relay measuring system responds and initiates a timing circuit, if the effective current exceeds the relay current setting. If the earth fault current remains above the

setting for the set time delay the output tripping contacts operates. The tripping time delay is independent of the current level. When applied in a power system the relay time delay must be selected so that it coordinates with other earth fault relays. Fig.5a and 5b illustrate the operating characteristic of the relay. Consider a relay with a current setting I E =1.5 A and a time delay setting t E =0.8s: Fig.5a: At t=0.s, the current exceeds the relay current setting and initiates the time delay circuit. The indicating LED I on the relay fascia is illuminated. At t=1s the earth fault current drops below the current setting. The LED I extinguishes and the time delay circuit reset to zero. There is no trip output. Fig. 5b: At t=0.s the current exceeds the relay current setting and initiates the relay time delay circuit as in the example described above and illustrated in fig.5a. At t=1.2s, e.g. 0.8s, after the current exceeded the relay setting the time delay has elapsed and the TRIP LED is illuminated. The relay produces a trip output and the relay current is interrupted. Fig. 5a and 5b. Current Transformer Connections Current transformer must be arranged so that the relay type measures zero sequences (or earth fault) currents as indicated schematically in figs. 1 and 2. This can be achieved by using several current transformers connected suitable or by using a single ring type current transformer. Earth fault measurement using several current transformers The arrangement shown in figs. 6 and 7 should be used only where significant levels of earth fault current are available (e.g. in solidly earthed or low impedance earthed networks) since the errors associated with each current transformer are additive and these are recognized by the relay as zero sequence current. Such an arrangement can therefore only be used where the relay current setting is in excess of the sum of the CT errors. Guide for dimensioning of CT s arrangement as shown in figs. 6 and 7 CT s must be matched and have the same current ration, accuracy class, rated output, secondary winding resistance and magnetising characteristic. The current ratio and primary current withstand should be selected according to the maximum rated current of the circuit. 2 / A l / A l I / A 1 0 1 t = <0.2s 2 I / A 2 I E -1.6A 1 t / s 0 Relay output contacts operate. Circuit breaker tripped. t =0.2s 1 2 t / s The combination of rated output, overcurrent factor and secondary winding resistance should be chosen such that a CT does not saturate at the maximum short circuit current. If this combination is not correct the CT may saturate under external phase fault conditions (i.e. for a 2 or phase fault which the relay should remains unoperated). In this case the several line CT s may saturate unequally. Therefore the sum of the secondary currents in no longer zero and the relay maloperates. 5

Fig. 6 and 7 P B = Burden connected to CT secondary circuit (VA) Earth fault current measuring using ring type CT s L1 L2 L L1 L2 L N The use of ring type current transformers for supplying earth fault relays as shown in fig. 8 and 9 is preferred wherever possible to the arrangement using separate CT s connected in parallel as indicated in figs. 6 and 7. E a b 6 7 11 12 E a b 6 7 11 12 Such an arrangement is particularly recommended for earth fault protection on high impedance earthed systems where the level of earth fault current is low. Fig. 6 Holmgreen connection, three phase three wire system Fig. 7 Three Phase, four wire system Relationship between CT actual overcurrent factor, rated overcurrent factor rated output, connected burden and secondary winding resistance. If the burden connected to the secondary winding of a current transformer does not match exactly the rated burden, the actual overcurrent factor of the CT will no longer be equal to the rated overcurrent factor. For example, if the total connected burden is less than the rated output of the CT, the actual overcurrent factor will be greater than the rated overcurrent factor. Conversely, if the total connected burden is greater than the rated output the CT, the actual overcurrent factor will be less than the rated overcurrent factor. Actual overcurrent factors can be calculated as follows: A ring type CT comprises a single magnetic core which surrounds all conductors and therefore under normal load conditions, or during two or three phase fault conditions, the resultant magnetic flux is zero and the CT produces no secondary current. Only in the presence of zero sequence current is the resultant flux not equal to zero and the CT produces a secondary current. Therefore, unlike the arrangement which summates, the secondary currents from several CT s under normal load and other non earth fault conditions, and which is the therefore sensitive to individual CT errors, a single ring type CT is not subject to the same errors and a very high degree of sensivity can be achieved. Fig. 8 and 9 L1 L2 L L1 L2 L N n = n P N -P E a b a b P B -P E where n = actual overcurrent factor n = rated overcurrent factor P N = Nominal rated output of CT (VA) P E = Burden of secondary winding resistance of CT rated current = 2 I N R CT (VA) E 6 7 11 12 Fig. 8 Measurement of earth fault current in a three phase, three wire system using a Ring type CT E 6 7 11 12 Fig. 9 Measurement of earth fault current in a three phase, four wire system using a Ring type CT 6

Guide for Dimensioning of Ring Type CT s The inside diameter of the CT must be large enough to slide over the cable. The primary rated current of the CT should match the maximum earth fault current in the case of high impedance earthed system. The rated secondary current is generally 1A or 5A. If a ring type CT is used, it is important to ensure that the cable and CT are installed precisely as shows in fig. 11 and cable gland must be insulated from the cable terminating box, and the cable sheath and armour must be earthed by taking the earth connection back through the CT as shown. If the earth lead is not connected as shown, the earth return current in the cable sheath or armour sets up a magnetic flux which cancels the flux produced by the earth current in the cable, and therefore the relay would not operate during an earth fault. the case of a feeder comprising several cables in parallel, a ring CT can be fitted to each cable. The CT secondary windings should then be connected in parallel and connected to a single earth fault relay type. CT s should have identical magnetising characteristic, ratio, rated output, accuracy class etc.. Connections, Contact Arrangement and Setting Adjustments Fig. 11 Cable and earthing arrangements when using Ring type CT L1 L2 L Fig.10 shows the main connections to the relay type. The auxiliary supply should be connected to terminals a and 6 and should be a secure supply with a variation of not greater than 10 per cent. Fig. 10 Relay connections earth connection cable gland to be insulated from earth cable S 2 (I) Ring type CT CT secondary current auxiliary supply voltage a b 6 7 11 12 E S1 (k) Fig.12 shows the position of the relay contacts. Under normal healthy conditions, or with no auxiliary voltage supplied the contacts are as shown in position 1. With the relay operated after the set time delay has elapsed, the contacts are shown as in position 2. 7

Fig. 12 Contact positions 5. Functional Check Contact position 1 Contact position 2 A simple functional check can be made with the aid of a secondary injection test set and an ammeter as follows: Connect rated auxiliary supply voltage to terminal a and 6. 11 12 11 12 Connect the injection test set output current terminals via an ammeter to the relay terminals 7 and b. No auxiliary voltage Protected system healthy Relay non-operated Relay operated Tripping Note that the injected current should be kept less than the rated current of the relay i.e. less than 1A or 5A as appropriate. Adjust the time delay setting potentiometer to t=0s. Fig. 1 Front cover of unit DC/AC a I> b TRIP 6 I k 7 EARTH FAULT CURRENT RELAY current time A 11 12 S With the current setting potentiometer set to a suitable value increase the current from the test set until the relay LED I is illuminated. This indicates that the relay has picked up. Since the set time delay t=0s, the tripping LED TRIP will be illuminated simultaneously. Check that the pick up current is within 5 per cent of the current setting on the relay. Switch off the test current. Adjust the time delay setting potentiometer to the required time delay. Switch on the test set, increase the test current to a value which is higher than the current setting. The relay will only operate and produce a trip output after the set time delay has elapsed. 9570 8

6. Technical Data -Earth Fault Current Relay General Data Design : electronic state definite time overcurrent relay with low-pass filter Maintenance : none Permissible operating time : continuous Mounting position : independent Auxiliary Supply Voltages Supply Voltage : 2 V, 110 V d.c Own consumption : 2.5 W Permissible voltage variation : ± 10% Measuring circuit Rated current I N : 1 A or 5 A Rated frequency : 50 Hz or 60 Hz Burden of current circuit : 0.5 VA at rated current Short time current setting : 20.I N for max. 1 S Current settings : 1 A relay: 0-100 ma/ 0-0.5 A 5A relay: 0-2A / 0 -A Time delay settings : 0.2-2s/0.5-s Reset radio : 99.5 % Output Circuits Contacts : 1 NC, 1 NO potential free Breaking capacity : 1000 VA at 250 V AC 2 A at 2 V dc Contact life : greater than 10 6 switching operations Terminals : M, wire termination max. conductor 2.5mm 2 Ambient Conditions Ambient temperature range: for storage : -0 0 C up to +70 0 C for operation within claimed accuracy : -20 0 C up to +60 0 C 9

Accuracy Effect of temperature : ± 1% of the setting over the range 0 0 C < V < 60 0 C Case, Dimensions, Weight and Installation Case : CSPC standard case Material : track resistant moulded base and transparent cover Height *width*depth : 12 mm*105 mm * 90 mm Weight : 0. kg (approx.) Mounting : Flush mounting Protection class case : IP20 terminals : IP00 Dimensions and drill-holes (dimensions in mm) 19 6.5 52.5 105 98.5 86 91.5 Dm-.8mm 11 16.5 126.5 111 26 15.5 105 Dm-.2mm 6 a a b 1 2 6 7 8 10 11 12 Freespace for bolts 10

7. Information required with order When placing an order, please fill in the form on the right. Earth fault relay Rated Current 1A 1 Rated Current 5A 5 Current ranges 1A (0-0.1 A) 0.1 (0-0.5 A) 0.5 5A (0-2 A) 2.0 (0 - A).0 Time Ranges 0.2-2 sec. 2 0.5 - sec. Auxiliary Voltage 2 V DC 2 110 V DC 110 11

FR//05.06.01/16005 12