Installation guide 877 FDI Field Display & Interface

Similar documents
Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 971 SmartRadar LTi

Installation guide 854 XTG Level Gauge

Installation guide 970 SmartRadar ATi

Installation guide 970, 971 and 973 series SmartRadar

Installation Guide dedicated O-ring for demanding chemicals applications with 854 ATG

Installation guide Roof reflector

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

VITO LT. Global Experience. Locally Applied. A dependable choice.

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

INSTRUCTION MANUAL (ATEX / IECEx)

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Head mounted Temperature Transmitter TF02/TF02-Ex

OPTIWAVE 7300 C Supplementary instructions

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

1-830 SERIES DISPLACEMENT TRANSMITTER

SET Installation and Operating Instructions. Level switch for two sensors

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Instruction manual 970 SmartRadar ATi

Process display RIA 261

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Rosemount 5408 and 5408:SIS Level Transmitters

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

SALES SERVICE +358 (0)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

ATEX Installation Drawings and Instructions

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

User's Manual Model SE14 Magnetic Flow Converter

IP26 Series Current to Pneumatic Converter

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Field indicator for current loops with HART communication Models DIH50, DIH52

Temperature Input Module for Zone 1 Series 9482/32

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Safety Instructions Nivotester FTC625, FTC325

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Isolators A3/1. Vibration Transducer Supply Unit Series

Sarasota CM200 Sarasota HME900 Density Converter Electronics

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Level Limit Switch nivotester FTL 325 P

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

R88000 T (including ATEX)

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Weighing Instruments

Rosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol

SINEAX B 811 Power Pack with additional Functions

IT6810/IT6811/IT6812 IMPACT TRANSMITTER Installation Manual

Positioner with HART Communication Type 3780

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Instruction manual 862 MIR Multiple temperature selector with MPU, HPU or OPU board

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Loop Powered Indicator

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

PRetrans Table of contents

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands

OPTITEMP TT 10 C/R Technical Datasheet

Introduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy

DRS390 High stability, flange mounting

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

SITRANS T measuring instruments for temperature

RMA42. Technical Information

8V General information. 2 Order data 8V

INTRINSIC SAFETY BASIC PRINCIPLES

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Submersible pressure sensor For oils and fuels Model LF-1

Operating Instructions

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

INSTALLATION AND OPERATION MANUAL

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Rail mounted Temperature Transmitter TH102/TH102-Ex

KMS-2 Exia Magnetostrictive Level Transmitter

Level Measurement Continuous level measurement Radar transmitters

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Operating Instructions

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Transcription:

Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website : http://www.honeywellenraf.com Installation guide 877 FDI Page 1

Preface The Honeywell Enraf 877 FDI is an explosion-proof field indicator for Honeywell Enraf=s series 854 servo level gauges and the series SmartRadar level gauges. The 877 FDI is suitable for hydrostatic level measurement (HTG) or for stand alone temperature measurement. This installation guide is intended for technicians involved in the mechanical and electrical installation of the Honeywell Enraf series 877 FDI (Field Display & Interface). EC declaration of conformity Refer to EC declaration of conformity, shipped with the instrument. All connections to the instrument must be made with shielded cables with exception of the mains, alarm outputs and Honeywell Enraf field bus cable. The shielding must be grounded in the cable gland on both ends of the cable. Legal aspects The mechanical and electrical installation shall only be carried out by trained personnel with knowledge of the requirements for installation of explosion-proof equipment in hazardous areas. The information in this installation guide is the copyright property of Enraf BV, Netherlands. Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by: $ Deviation from any of the prescribed procedures; $ Execution of activities that are not prescribed; $ Neglect of the general safety precautions for handling tools, use of electricity and microwave radiation. The contents, descriptions and specifications in this installation guide are subject to change without notice. Enraf BV accepts no responsibility for any errors that may appear in this installation guide. Additional information Please do not hesitate to contact Honeywell Enraf or its representative if you require additional information. Page 2 Installation guide 877 FDI

Safety Safety Safety aspects of 877 FDI Warning Do not use the instrument for anything else than its intended purpose. The housing of the 877 Field Display & Interface is explosion proof: $ II 1/2 G EEx d [ia/ib] IIB T5 acc. to KEMA 03ATEX1098, certified by KEMA, Netherlands $ Class I, Division 1, Groups B, C and D, (Factory Mutual no. 2Q1A6.AE) $ Class I, Division 1, Groups C and D; CSA Encl. 4 (CSA number: LR 46612-11) Environmental conditions for the 877 FDI are: ambient temperature : -40 to +65 C (-40 to +149 F) relative humidity : 0-100 % ingress protection : IP67 (NEMA Type 6P), suitable for outdoor installation The cover can optionally be provided with sealing facility on the blocking device which prevents unauthorized opening. One separate cable entry is provided for intrinsically safe options. Warning Improper installation of cable glands, conduits or stopping plugs will invalidate the Ex approval of the 877 FDI. Installation guide 877 FDI Page 3

Safety Personal safety The technician must have basic technical skills to be able to safely install the equipment. When the 877 FDI is installed in a hazardous area, the technician must work in accordance with the (local) requirements for electrical equipment in hazardous areas. Warning In hazardous areas it is compulsory to use personal protection and safety gear such as: hard hat, fire-resistive overall, safety shoes, safety glasses and working gloves. Avoid possible generation of static electricity. Use non-sparking tools and explosion-proof testers. Make sure no dangerous quantities of combustible gas mixtures are present in the working area. Never start working before the work permit has been signed by all parties. Safety conventions AWarnings@, ACautions@ and ANotes@ are used throughout this installation guide to bring special matters to the immediate attention of the reader. $ A Warning concerns danger to the safety of the technician or user; $ A Caution draws the attention to an action which may damage the equipment; $ A Note points out a statement deserving more emphasis than the general text, but not requiring a AWarning@ or a ACaution@. Page 4 Installation guide 877 FDI

Mechanical installation Mechanical installation The entire installation procedure shall be in accordance with national, local and company regulations. The 877 FDI can be installed at the base of the tank near the tank shell or at any other suitable location. Sometimes the optional thermometer or pressure transmitter determines the location. Refer to Appendix A for the dimensions of the 877 FDI and the dimensions of the four mounting holes. The mounting holes are located at the rear side of the indicator. Leave sufficient space for the Infra-red connector and for removal of the cover. Secure the indicator with four bolts size M10 ( 5 / 8 "). The weight of the 877 FDI is 12 kg (26 lbs). Installation guide 877 FDI Page 5

Electrical installation Electrical installation The entire electrical installation shall be in accordance with International Standard IEC 79-14 for electrical equipment to be installed in hazardous areas. Warning Make sure that all power to the instrument is switched off before opening the cover of the 877 FDI. Failure to do so may cause danger to persons or damage the equipment. The cover of the 877 FDI must be closed before switching on the power. Caution Before opening the cover of the 877 FDI, make sure that the blocking device is removed (figure 1). Figure 1 Blocking / sealing device Caution Do not damage the thread of the cover and instrument and keep the threads free of dirt. After opening, grease it lightly with anti seize grease. When closing, never tighten the cover before the thread is properly engaged. The cover should be turned counter-clockwise until the thread Aclicks@ in place, then turn clockwise until the cover is fully closed. After closing the cover, do not forget to place the blocking device. Page 6 Installation guide 877 FDI

Electrical installation Preparing 877 FDI for electrical installation Mains voltage selector Check whether voltage selector is set correctly as indicated on identification label of the indicator as well as for the presented supply. The voltage selector is located inside the indicator on top of the backplane (figure 2). The 877 FDI operates on a mains voltage of 110, 130, 220 (+10% to -20%) and 230 Vac ("15%). A special 65 Vac (+10% to -20%) is available. Power rating: 25 VA (20 VA for FM); frequency: 50 to 60 Hz ("10%); I max = 2 A. Install an explosion-proof mains switch in the mains supply cable to each 877 FDI. Specify which switch you need to operate the 877 FDI. Figure 2 Voltage selector For 240 V supply voltage, set voltage selector to 230 V. Supply voltage may then vary from +10% to -20%. To change voltage setting, proceed as follows: 1) Check the local mains voltage 2) Open the cover of the 877 FDI 3) If necessary, change the voltage selector to applicable voltage: $ remove mains supply indication plate (Allen key size 3 mm) $ slide the mains selector switch in appropriate position (refer to figure 2) $ place mains supply indication plate and lock it 4) Close cover Caution Changes of the mains setting shall be marked on the identification label of the 877 FDI. Installation guide 877 FDI Page 7

Electrical installation External fuses The 877 FDI is internally fused on secondary side of transformer (fuses are located on the GPS board). Therefore, external fuses must be installed in the mains supply cable to each 877 FDI. Grounding Mains voltage Fuse value (in accordance to IEC 127-2-3) 220 / 230 Vac 315 ma slow 110 / 130 Vac 630 ma slow 65 Vac 1 A slow The 877 FDI housing should be properly grounded to the ground reference (generally the tank). This is a safety grounding requirement. For this purpose, the 877 FDI housing has external ground terminals. Caution Safety depends on proper grounding. Check the resistance of the ground connection directly after installation. The measured ground resistance shall be below the maximum prescribed by local grounding requirements. Warning when measuring the ground resistance, use a suitable explosion-proof tester. Grounding shall be performed in accordance with local regulations. Cable glands / conduit Cable glands: The 877 FDI requires explosion-proof (Ex-d) cable glands. Mount the glands according to the supplier=s instructions. Conduit: If the 877 FDI is installed in a hazardous area, threaded rigid metal conduit or threaded steel intermediate metal conduit shall be used. If the 877 FDI is installed in a hazardous area, stopper boxes must be applied within 18 inches (0.45 m) from the 877 FDI to seal the cabling in the conduit. Page 8 Installation guide 877 FDI

Electrical installation Depending on the wiring configuration, one to three :" NPT threaded cable glands (or rigid conduits) may be required with the 877 FDI. Refer to Appendix A for the cable entry dimensions of the 877 FDI. Warning Improper installation of cable glands, conduits or stopping plugs will invalidate the Ex approval of the 877 FDI. Seal unused cable inlets with an approved :@ NPT stopping plug. Terminal strip The terminal strip is located against the rear side of the 877 FDI housing above the cable entries. To reach the terminal strip, the cover has to be removed as well as all printed circuit boards (figure 3). Warning Only open the cover of the 877 FDI when the power is switched off. To connect the wiring, proceed as follows: 1) Open cover of 877 FDI (make sure power is switched off) 2) Remove PCB retaining screw (B) and slide locking latch (A) to the right 3) Remove XPU(-2) board, optional boards (if present) and GPS board. It is advised to (temporary) disconnect the non - i.s. wiring from the optional boards, if present, in order to remove the board and reach the terminal strip. Terminal strip lay-out depends on model Figure 3 Reaching the terminal strip and installed options. Installation guide 877 FDI Page 9

Electrical installation Non-intrinsically safe cabling The terminal strip of the 877 FDI is divided in a non-intrinsically safe part and an intrinsically safe part. Cable entries are :@ NPT. The non-intrinsically safe wiring may only enter at the middle and left hand side cable entries (refer to figure 3). Mains cabling : Enraf field bus : Must be suitable for the 877 FDI power ratings and, moreover, approved for use in hazardous areas. One twisted pair cable is recommended. R max = 200 Ω / line; C max = 1 µf. Maximum length: 10 km. Enraf field bus lines may be interchanged (valid for T/T and 3/5). If local regulations allows, mains and Enraf field bus lines may share one cable. Mind the isolation voltage of the cores in the cable; refer to the International Standard IEC 61010-1. If a quad cable is used and all four cores are twisted together, use two opposite cores for Enraf field bus lines and the two others for mains. Relay outputs : Option. The relay contacts are potential free. Contact rating: U max = 50 Vac or 75 Vdc; I max = 3 A non-inductive (CSA allows 0.6 A). Mind the isolation voltage of the cores in the cable; refer to the International Standard IEC 61010-1. Analog output : Option. Use a shielded cable. External supply voltage: $ minimum: 12 Vdc $ maximum: 64 Vdc Page 10 Installation guide 877 FDI

Electrical installation When the voltage exceeds 30 Vdc, an additional resistor is required. The permitted operational areas are shown in figure 4. Operational area 1 represents the area of operation without the need for an external loop resistance. Operational area 2 shows the area where a resistance is required. Power rating resistor: 1 W / kω. Figure 4 Selecting external loop resistor Figure 5 Non-intrinsically safe connections Installation guide 877 FDI Page 11

Electrical installation Optional RS communication connections For the cable connection requirements of the mains and alarm contacts, refer to previous section. Caution Keep the RS-232C / RS-485 lines as short as possible. RS-232C : Cable requirements: maximum length 15 m (50 ft); twisted and shielded. RS-485 : Cable requirements: maximum length 1200 m (3900 ft); twisted and shielded. Figure 6 RS-232C and RS-485 connections Page 12 Installation guide 877 FDI

Electrical installation Intrinsically safe options The cable for the intrinsically safe options shall only be fed through the right hand side cable entry. Blue marked cables are recommended for the intrinsically safe options. Caution The intrinsically safe options described in this section are explosion-proof certified. Make sure that the certificate of approval is available on site and act in accordance with the instructions as given in the approval certificate. Caution Intrinsically safe wiring shall be separated from all other wiring. Cable lay-out shall be in accordance with local regulations. The shield of the intrinsically safe cable shall not be connected inside the 877 FDI housing. Connect the shield of the cable externally in the cable gland at both ends of the cable. Device Spot temperature element : Cable requirements Shielded; R max = 12 Ω / line. Average temp. element : Twisted pair and shielded; R max = 25 Ω / line. (combined water probe) Wiring between the 877 FDI and 762 VITO must be protected with EMC shielded conduit. Same conditions for connection to 862 MIR. Pressure transmitters : Twisted pair and shielded; R max = 25 Ω / line (only pressure transmitters with HART 7 protocol). Pressure transmitter P1 is the bottom transmitter, P2 is the middle transmitter and P3 is the top transmitter. If pressure transmitters are connected to HART input 2, it must be verified that the maximum values for current and power of the HCU option board HART input 2 circuit are not exceeding the maximum values of the connected pressure transmitters. Refer to Appendix B. If the values of the HART input 2 circuit are too high, then connect the pressure transmitters to HART input 1 and the 762 VITO Interface to HART input 2 (only possible when HART input 1 is available). Installation guide 877 FDI Page 13

Electrical installation Device Cable requirements 977 Tank Side Indicator : Twisted pair and shielded; R max = 5 Ω / line, maximum cable length 50 m (160 ft). Water bottom probe : Twisted and shielded pair; R max = 25 Ω / line. (no VITO water sensor) (only with HART 7 protocol) If also pressure transmitters are connected, use a junction box for the parallel connection of the pressure transmitters and water bottom probe. Caution When junction boxes are used in the intrinsically safe wiring loop, make sure they are approved for the application and are equipped with approved terminals and have correct entries for the cable glands. Figure 7 Intrinsically safe connections with MPU-3 / HPU option board Page 14 Installation guide 877 FDI

Electrical installation Figure 8 Intrinsically safe connections with HCU option board Installation guide 877 FDI Page 15

Appendix Appendix A Dimensional drawing Page 16 Installation guide 877 FDI

Appendix Installation guide 877 FDI Page 17

Appendix Appendix B ATEX approval The 877 FDI has been ATEX approved as explosion proof. Hence, explosion-proof EEx d approved glands or conduit are to be used. Connection requirements of optional boards The identification label on the 877 FDI indicates whether your instrument is equipped with an optional board with intrinsically safe measuring circuits. XPU-2 board (i.s. option), [EEx ib] IIB Output circuit for 977 TSI: Max. values : U = 21 V; I = 395 ma; P = 1.41 W Max. permissible ext. inductance : 0.8 mh Max. permissible ext. capacitance : 1.27 µf HCU option board, [EEx ia] IIB Spot temperature input circuit: Max. values : U = 23.1 V; I = 221 ma; P = 0.19 W Max. permissible ext. inductance : 3.5 mh Max. permissible ext. capacitance : 980 nf HART input 1 circuit (for 762 VITO Interface): Max. values : U = 23.1 V; I = 90 ma; P = 0.52 W Max. permissible ext. inductance : 15 mh Max. permissible ext. capacitance : 1.02 µf HART input 2 circuit (for HART 7 pressure transmitters and/or external water probe): Max. values : U = 23.1 V; I = 148 ma; P = 0.86 W Max. permissible ext. inductance : 7 mh Max. permissible ext. capacitance : 1.02 µf MPU-3 option board, [EEx ib] IIB 862 MIR input circuit: Max. values : U = 21 V; I = 231 ma; P = 0.88 W Max. permissible ext. inductance : 3 mh Max. permissible ext. capacitance : 1.27 µf Page 18 Installation guide 877 FDI

Appendix HPU option board, [EEx ib] IIB 862 MIR input circuit: Max. values : U = 21 V; I = 221 ma; P = 0.86 W Max. permissible ext. inductance : 3 mh Max. permissible ext. capacitance : 1.27 µf HPU option board, [EEx ia] IIB HART input circuit (for HART 7 pressure transmitters and/or external water probe): Max. values : U = 21 V; I = 148 ma; P = 0.72 W Max. permissible ext. inductance : 6 mh Max. permissible ext. capacitance : 1.27 µf Installation guide 877 FDI Page 19

Appendix Appendix C Related documents Instruction manual 877 FDI Field Display & Interface Instruction manual RPU Hard alarm output contacts Installation guide 762 VITO Interface & 764, 765 or 766 VITO temperature and/or water sensors Installation guide 977 Tank Side Indicator Instruction manual XPU-2 option RS-232C/RS-485 Instruction manual Temperature, Water bottom and Analog output options Instruction manual HIMS / HTG and vapour pressure (P3) measurement Instruction manual 847 PET Installation Info 003 (Installation HTG / HIMS systems) Identification code 877 FDI Field Display & Interface Page 20 Installation guide 877 FDI

Delftechpark 39 2628 XJ Delft Tel. :+31 15 2701 100 E-mail : enraf-nl@honeywell.com Webiste: www.honeywellenraf.com PO Box 812 2600 AV Delft The Netherlands We at Honeywell Enraf are committed to excellence. Information in this publication is subject to change without notice Enraf is a registered trade mark. Enraf B.V. Netherlands Installation guide 877 FDI Page 21