Power Quality improvement of a three phase four wire system using UPQC

Similar documents
Enhancement of Power Quality Using Advanced Series Active Power Filters

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

2020 P a g e. Figure.2: Line diagram of series active power filter.

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

P.CHAITHANYAKUMAR, T.VARAPRASAD/

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015


Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Power Quality Improvement using Shunt Passive Filter

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Mitigation of Harmonics in Distribution System Using SAPF

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

Comparison of Shunt Active Power Filter Control Strategies for Harmonic Compensation in a Paper Industrial Factory

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Review on Shunt Active Power Filter for Three Phase Four Wire System

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Improvement of Power Quality Using a Hybrid Interline UPQC

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Unified Power Quality conditioner in Grid connected Photovoltaic System

International Journal of Advance Research in Engineering, Science & Technology

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

A NOVEL STRUCTURE FOR THREE-PHASE FOUR-WIRE DISTRIBUTION SYSTEM UPQC

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Mitigation of Voltage Sag/Swell Using UPQC

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

MODELING AND CONTROLLING OF AC VOLTAGE STABILIZER USING SERIES ACTIVE POWER FILTER

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Shunt active filter algorithms for a three phase system fed to adjustable speed drive

Power Quality Improvement using Active shunt Power filter using PI Controller

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

POWER QUALITY IMPROVEMENT USING UNIFIED POWER QUALITY CONDITIONER (UPQC) Piyush Anand DEPARTMENT OF ELECTRICAL ENGINEERING

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Indirect Current Control of LCL Based Shunt Active Power Filter

A New Unified Power Quality Conditioner for Grid Integration of PV System and Power Quality Improvement Feature Distribution System

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Selective Harmonic Elimination Using Three Phase Shunt Active Power Filter

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

A Modified UPQC Topology Using Fuzzy Based Control of VSI with Reduced DC Link Voltage Rating

Power Control and Quality Management in DG Grid Interfaced Systems

SHUNT ACTIVE POWER FILTER

Power Quality Improvement in Fourteen Bus System using UPQC

Literature Review for Shunt Active Power Filters

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

STATCOM BASED ON REDUCTION OF PQ ISSUES IN MICRO GRID APPLICATION SYSTEMS

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

ISSN Vol.03,Issue.11, December-2015, Pages:

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

p. 1 p. 6 p. 22 p. 46 p. 58

Control of Shunt Active Power Filter for Improvement of Power Quality

Dynamic Modeling and Simulation of Unified Power Quality Conditioner

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

ANALYSIS OF UNIFIED POWER QUALITY CONDITIONER DURING VOLTAGE SAG AND SWELL CONDITIONS

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Control Strategy for a cross phase connected and a conventional UPQC

Neural Network Controlled Hybrid Active Power Filter with Distorted Mains for PMSM Drive

B.Tech Academic Projects EEE (Simulation)

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Transcription:

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 Power Quality improvement of a three phase four wire system using UPQC D.Prathyusha, P.Venkatesh 1 M-Tech Student, EEE Dept, V.R.SIDDHARTHA Engineering College, Vijayawada, A.P, India. 2 Asst.Professor, EEE Dept, V.R.SIDDHARTHA Engineering College, Vijayawada, A.P, India ------------------------------------------------------------------------------------------------------------------------------------------ Abstract This paper presents two different control tuning time dependence of filter parameters have ignited strategies applied to Unified Power Quality Conditioner the need for active and hybrid filters. The rating of active (UPQC) to improve power quality in a three-phase, four-wire filters is reduced through augmenting them with passive distribution system. The two control techniques are Unit filters to form hybrid filters, which reduce overall cost. Vector Template Generation (UVTG) technique and Also they can provide better compensation than either Synchronous Reference Frame (SRF). Generally, some passive or active filters. If one can afford the cost, then a topologies applied for three-phase, four-wire UPQC use hybrid of two active filters provides the best solution and active compensation for the mitigation of source neutral thus it is known as a unified power quality conditioner current along with other power quality (PQ) problems, (UPQC) or universal active filter. Therefore, the while the uses of passive elements for the mitigation of development of hybrid filter technology has been from a source neutral current are advantageous over the active hybrid of passive filters to a hybrid of active filters to compensation due to ruggedness and less complexity of provide a cost-effective solution and optimal control. Hence, in this paper a star-delta transformer is compensation. connected in shunt near the load for mitigation of source neutral current, while three-leg voltage source inverters (VSIs) based shunt and series active power filters (APFs) of three-phase UPQC mitigate the current and voltage based distortions, respectively. Here two control techniques are compared in terms of Total Harmonic Distortion (THD).This is done by using MATLAB/ Simulink. Key Words: Active Power Filter (APF), Power Quality(PQ),Unit Vector template Generation (UVTG), Unified Power Quality conditioner (UPQC), three phase four wire(3p4w) system, Synchronous Reference Frame (SRF). 1. Introduction The main objective of electric utility companies is to supply their customers with uninterrupted sinusoidal voltage of constant magnitude. However this is becoming increasingly difficult to do, because the size and number of non-linear and poor power factor loads such as adjustable speed drives, computer power supplies, furnaces and traction drives are increasing rapidly. Due to their nonlinear nature, these solid state converters cause excessive neutral currents in three phase four wire systems. Moreover, in the case of the distribution system, the overall load on the system is seldom found to be balanced. In the past, the solutions to mitigate these identified power quality problems were through using conventional passive filters. But their limitations such as, fixed compensation, resonance with source impedance and the difficulty in The function of unified power quality conditioner is to compensate supply voltage flicker/imbalance, reactive power, negative-sequence current, and harmonics. In other words, the UPQC has the capability of improving power quality at the point of installation on power distribution systems or industrial power systems. Therefore, the UPQC is expected to be one of the most powerful solutions to large capacity loads sensitive to supply voltage flicker/ imbalance. The UPQC consisting of the combination of a series active power filter (APF) and shunt APF can also compensate the voltage interruption if it has some energy storage or battery in the dc link.the proposed control technique has been evaluated and tested under unbalanced load conditions using MATLAB/ Simulink software. 2. Unified Power-Quality Conditioner (UPQC) The UPQC consists of two voltage source inverters connected back to back with each other sharing a common dc link. One inverter is controlled as a variable voltage source in the series APF, and the other as a variable current source in the shunt APF. Fig. 1 shows a basic system configuration of a general UPQC consisting of the combination of a series APF and shunt APF. The main aim of the series APF is harmonic isolation between load and supply; it has the capability of voltage flicker/ imbalance compensation as well as voltage regulation and harmonic compensation at the utility-consumer PCC. The shunt APF is used to absorb current harmonics, compensate for reactive power and negative-sequence current, and regulate the dc link voltage between both APFs. 215, IRJET ISO 91:28 Certified Journal Page 24

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 v fc), which cancel outs the distortions present in the supply voltages (v sa, v sb and v sc), thus making the voltages at PCC (v la, v lb and v lc) perfectly sinusoidal with the desired amplitude.. Fig.1 Basic system configuration of UPQC In this paper unified power quality conditioner (UPQC) is being used as a universal active power conditioning device to mitigate both current as well as voltage harmonics at a distribution end of power system network. 3. System Configuration Fig. 2 shows a 3P-4W UPQC topology, which is feeding a combination of linear and non-linear unbalanced load. The series and shunt APFs are realized using two readily available three-leg VSIs. The dc links of both APFs are connected to a common dc link capacitor. The series APF is connected between the supply and load terminals through a three single phase transformers. Fig.2 Detailed configuration of star-delta transformer supported UPQC In this topology, a star-delta transformer is connected in shunt near the load for the mitigation of the source neutral current. The delta connected secondary provides a circulating path to the zero sequence current (i o) in case of unbalanced load and hence the supply neutral current is reduced to zero. 4. UVTG Control Strategy 4.1. Series Control Strategy: A simple control algorithm based on UVTG [1] is used to control the series APF of proposed topology. The series is controlled in such a way that it injects voltages (v fa, v fb and Fig.3 Control Scheme of Series APF In other words, the sum of supply voltage and the injected series filter voltage makes the desired voltage at the load terminals. The control strategy for the series APF is shown in Fig. 3.Three-phase distorted supply voltages are sensed and given to PLL which generates two quadrature unit vectors (sin θ, cos θ). The in-phase sine and cosine outputs from the PLL are used to compute the supply in phase, 12 displaced three unit vectors (ua, ub and uc) using eqn. as u 1 a sin 1 3 ub cos 2 2 u c 1 3 2 2 The computed three in-phase unit vectors then multiplied with the desired peak value of the PCC phase voltage (V lm), which becomes the three-phase reference PCC voltages as: v la ua v lb V lm ub v lc u c The computed voltages from reference voltages from equation above are then given to the hysteresis voltage controller along with the sensed three phase PCC voltages (v la, v lb and v lc). The output of the hysteresis controller is switching signals to the six switches of the VSI of series APF. The hysteresis controller generates the switching signals such that the voltage at PCC becomes the desired sinusoidal reference voltage. 4.2. Shunt Control Strategy: The control algorithm for shunt APF [1] consists of the generation of three-phase reference supply currents (i sa, i sb and i sc) and it is depicted in Fig.4. 215, IRJET ISO 91:28 Certified Journal Page 25...

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 Fig.4 Control Scheme of Shunt APF This algorithm uses supply in-phase; 12 displaced three unit vectors computed in eqn. The amplitude of the reference supply current (I sp) is computed from the comparison of average and the reference value of the dc bus voltage of the back to back connected VSIs results in voltage error, which is fed to a proportional integral (PI) controller. The output of the PI controller is taken as the reference amplitude (I sp) of the supply currents. The three in-phase reference supply currents are computed by multiplying their amplitude (I sp) and in-phase unit current vectors as: i sa ua i sb I sp ub i sc u c The computed three-phase supply reference currents are compared with the sensed supply currents and are given to a hysteresis current controller to generate the switching signals to the switches of the shunt APF which makes the supply currents follow its reference values. In this control scheme, the current control is applied over the fundamental supply currents instead of the fast changing APF currents, thereby reducing the computational delay and number of required sensor. In addition to this, no extra control is required for the mitigation of source neutral current. The simulation model of three phase four wire Unified Power Quality Conditioner(UPQC) is shown in fig.5 at the same time for series APFs. In the proposed method, the series APF controller calculates the reference value to be injected to the system by comparing the positivesequence component of the source voltages with load-side line voltages. The supply voltages V Sabc are transformed to d q by using the transformation matrix T given below 1 1 1 2 2 2 2 2 2 T sint sint sint 3 3 3 2 2 cost cost cost 3 3 The instantaneous source voltages (v Sd and v Sq) include both oscillating components (ṽ Sd and ṽ Sq) and average components (v Sd and v Sq) under unbalanced source voltage with harmonics. The oscillating components of v Sd and v Sq consist of the harmonics and negative-sequence components. The load reference voltages (V Labc) are calculated as The produced load reference voltages (v _La, v Lb, and v Lc) and load voltages (v La, v Lb, and v Lc) are compared in hysteresis controller to produce insulated-gate bipolar transistor (IGBT) switching signals and to compensate all voltage-related problems, such as voltage harmonics, sag, swell, voltage unbalance, etc., at the PCC. 5.SRF Control Technique In the SRF-based APF applications in three-phase fourwire (3P4W) systems, voltage and current signals are transformed into the conventional rotating frame (d q ). In the SRF method, the transformation angle (ωt) represents the angular position of the reference frame which is rotating at a constant speed in synchronism with the three-phase ac voltage. 5.1Reference voltage generation: The proposed SRF-based UPQC control algorithm can be used to solve the PQ problems related with source-voltage harmonics, unbalanced voltages, and voltage sag and swell Fig.5 Synchronous Reference Frame Control 5.2 Reference current generation: The proposed SRF-based shunt APF reference source current signal generation algorithm uses only source 215, IRJET ISO 91:28 Certified Journal Page 26

Injected voltage(v) Load voltage(v) Load voltage(v) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 voltages, source currents, and dc-link voltages. The source currents are transformed to d q coordinates The dc-link voltage is compared with its reference value (V DC), and the required active current (i dloss) is obtained by a PI controller. The source current fundamental reference component is calculated by adding to the required active current and source current average component (i Sd), which is obtained by an LPF, In the proposed method, the zero- and negative-sequence components of the source current reference (i s and i Sq) in the - and q-axes are set to zero in order to compensate the harmonics, unbalance, distortion, and reactive power in the source current. The source current references are calculated as distorted voltage profile is shown in fig.6.the UPQC should maintain the voltage at load bus at a desired value and free from distortion. The plant load is assumed to be the combination of a balanced three-phase diode bridge rectifier followed by an R L load, and three single-phase loads. The series APF injects the required compensating voltages through series transformer, making the load voltage free from distortion are shown in fig.7. The series APF injected profile is shown in fig.8. Simultaneously, the shunt APF injects the compensating currents to achieve the balanced source current, free from distortion, as discussed in the previous section. With UPQC source current waveform is shown in fig.9. Load neutral current and transformer neutral current are shown in fig.1 and fig.11 respectively. Transformer neutral current is exactly opposite to the load neutral current so that source neutral current reduced to zero. 4 3 2 The produced reference-source currents ( and ) and measured source currents ( i Sa, i Sb, and i Sc ) are compared by a hysteresis controller to produce switching signals. 1-1 -2-3 -4.5.1.15.2.25.3.35.4 Fig.7 load voltage without UPQC 4 3 2 1-1 -2-3 -4.6.8.1.12.14.16.18.2.22.24 Fig.8 Load voltage with UPQC Fig.6 MATLAB model of star-delta transformer supported UPQC 6. Simulation Results In this study, the control algorithm for the UPQC is evaluated by using MATLAB/Simulink software under combination of linear and nonlinear load conditions. The simulation results for the proposed three phase four wire system realized from a three phase three wire system utilizing UPQC are shown in below. Without UPQC load voltages are distorted with voltage THD of 28.28%.The 2 15 1 5-5 -1-15 -2.15.16.17.18.19.2.21.22.23.24 Fig.9 Series Injected voltage 215, IRJET ISO 91:28 Certified Journal Page 27

Source neutral current(a) Transformer neutral current Load neutral current Source Current(A) International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 4 3 2 1-1 -2-3 -4.15.16.17.18.19.2.21.22.23.24 Fig.1 source current 8 6 4 Fig.14 THD of load voltage without UPQC 2-2 -4-6.15.16.17.18.19.2.21.22.23.24 Fig.11 load neutral current 6 4 2 Fig.15 THD of load voltage with UVTG control -2-4 -6-8.15.16.17.18.19.2.21.22.23.24 Fig.12 transformer neutral current 1.5 Fig.16 THD of load voltage with SRF control -.5-1.15.16.17.18.19.2.21.22.23.24 Fig.13 source neutral current The harmonic spectrums of load voltage without UPQC is shown in fig.14 and it is having a harmonic distortion of 28.28%.After connecting UPQC with two control techniques the load voltage distortion is reduced and it is shown in fig.15 and fig.16.source current THD is shown in fig.17 and fig 18. Fig.17 THD of source current with UVTG control 215, IRJET ISO 91:28 Certified Journal Page 28

International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 2 Issue: 4 July-215 www.irjet.net p-issn: 2395-72 8. APPENDIX Fig.18 THD of source current with SRF control Pha se A Pha se B Pha se C Total Harmonic Distortion (%) without UPQC With UPQC With UVTG voltage current voltage curren t voltage With SRF curren t 28.28 17.94 3.4.53 1.96.34 28.28 2.93 2.77.58 1.91.42 28.29 21.22 2.78.7 1.93.28 Table.1 comparison of THD s with UVTG and SRF techniques 7. CONCLUSION The control of unified power quality conditioner (UPQC) is done by using two control techniques Unit Vector Template Generation (UVTG) and Synchronous Reference Frame (SRF) in a three phase four wire distribution system. This proposed topology would be very useful to expand the existing three phase three wire system to three phase four wire system where UPQC is installed to compensate the different power quality problems. The MATLAB/Simulink based simulation results show that the source currents and load voltages are perfectly balanced and are free from distortion by applying both control techniques. The star-delta transformer connected near the load effectively compensates the source neutral current. By connecting a star-delta transformer on the load side, the rating of the UPQC is reduced due to elimination of a fourth leg compared to three-phase four-leg VSI based three phase four wire UPQC. In addition to this, no extra control is required for the mitigation of neutral current; hence numbers of current sensors are reduced. The system parameters used are as follows: Supply voltage: 4V (Vrms) Supply impedance: R=.1Ω,L=.1mH DC link capacitance value: 1mF Three phase Transformer: 25MVA, 124V/19V/5V. Linear load: 6KW, 3KVar lagging load in phase a, 3KW, 9Var lagging load in phase b, 2KW, 25Var lagging load in phase c. Non-Linear load: Three-Phase Rectifier Load R=6 and L=5mH on dc side. Star-delta transformer: 5 KVA, 231V/231 V REFERENCES 1. Yash Pal, A. Swarup, B. Singh A New Topology of Three-Phase Four-Wire UPQC with a Simplified Control Algorithm, Majlesi Journal of Electrical Engineering Vol. 6, No. 1, March 212 2. Metin Kesler and Engin Ozdemir, Synchronous Reference Frame based control method for UPQC under unbalanced and distorted load conditions IEEE transactions on industrial electronics, vol. 58, no. 9, September 211. 3. V. khadkikar and A. Chandra, A novel structure for three-phase four wire distribution system utilizing unified power quality conditioner (UPQC), IEEE Transaction on industry application, Vol.45,no.5,Sep/oct.29. 4. Bhim Singh and Venkateswarlu.P, A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner, Journal of Power Electronics, Vol. 1, No. 1, January 21. 5. Paduchuri. Chandra Babu and Subhransu.Sekhar.Dash, Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System, International Journal of Computer and Electrical Engineering, Vol.4, No.1, February 212. 6. Metin Kesler and Engin Ozdemir, A Novel Control Method for Unified Power Quality Conditioner (UPQC) Under Non-ideal Mains Voltage and Unbalanced Load Conditions IEEE 21. 215, IRJET ISO 91:28 Certified Journal Page 29