Operator s Manual. PP016 Passive Probe

Similar documents
Operator s Manual. PP017 and PP018 Passive Probes

Operator s Manual. PP022 Passive Probe

PKT 512A-RO High Impedance Passive Cable Divider

TETRIS User's Guide. High Impedance Active Probe DO177-1

PHV RO High Voltage Passive Probe. Instruction Manual

TA MHz oscilloscope probe TA MHz oscilloscope probe

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

TK 100 Probe Calibrator. Instruction Manual

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

TT-SI 9001 / TT-SI MHz Active Differential Probes

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

WaveStation 3000 Function/Arbitrary Waveform Generator Getting Started Guide

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TT-SI MHz DIFFERENTIAL PROBE

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

PML 711A-RO High impedance passive probe Features:

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

374 FC/375 FC/376 FC Clamp Meter

N2790A Differential Voltage Probe

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Keysight N2771B 30 kv High Voltage Probe

Agilent 1146A AC/DC Oscilloscope Current Probe

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

Agilent 1160 Series Miniature Passive Oscilloscope Probes. User s Guide

User s Guide. Model MA A AC Mini Clamp-on Meter

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

323/324/325 Clamp Meter

N2792A and N2793A Differential Probes User s Guide

MODEL 3810/2 Line Impedance Stabilization Network

312, 316, 318. Clamp Meter. Users Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

2015 RIGOL TECHNOLOGIES, INC.

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

Keysight N2790A Differential Voltage Probe. User Guide

MS2030 CAT III 600 V A V AUTO RS232

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

1147A 50 MHz Current Probe

MODEL W Power Amplifier

Electrical Multimeter

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

User s Manual Current Probe IM E. 8th Edition

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

712C. Users Manual. RTD Calibrator

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Dawson DDM190. Digital Multimeter User s Manual

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

INSTRUCTION MANUAL UTL260

200Amp AC Clamp Meter + NCV Model MA250

Pen Multimeter. Model

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

netzerotools.com 374/375/376 Users Manual Clamp Meter

User s Manual Current Probe. IM E 2nd Edition IM E

DMM8900 SERIES USERS MANUAL

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

NOTE: Fully read and understand this manual before using this Digital Multimeter.

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

80i-110s. AC/DC Current Probe Instructions. Introduction

User s Manual Current Probe IM E. 6th Edition

374/375/376 Clamp Meter

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

Model /701913/ PBA1000/2500/1500 Active Probe

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

VT1586A Rack Mount Terminal Panel Installation and User s Manual

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Tablet Oscilloscope Safety Information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User s Guide. Digital AC/DC Clamp Meter Model 38394

374/375/376. Calibration Manual. Clamp Meter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

374/375/376 Clamp Meter

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Glass Electrode Meter

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

Transcription:

Operator s Manual PP016 Passive Probe

2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted to duplicate and distribute Teledyne LeCroy documentation for internal educational purposes. Teledyne LeCroy is a registered trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice. Warranty Teledyne LeCroy warrants this oscilloscope accessory for normal use and operation within specification for a period of one year from the date of shipment. Spare parts, replacement parts and repairs are warranted for 90 days. In exercising its warranty, Teledyne LeCroy, at its option, will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized service center. However, this will be done only if the product is determined by Teledyne LeCroy s examination to be defective due to workmanship or materials, and the defect is not caused by misuse, neglect, accident, abnormal conditions of operation, or damage resulting from attempted repair or modifications by a non-authorized service facility. The customer will be responsible for the transportation and insurance charges for the return of products to the service facility. Teledyne LeCroy will return all products under warranty with transportation charges prepaid. This warranty replaces all other warranties, expressed or implied, including but not limited to any implied warranty of merchantability, fitness or adequacy for any particular purposes or use. Teledyne LeCroy shall not be liable for any special, incidental, or consequential damages, whether in contract or otherwise. 928602-00 Rev A July, 2017

Safety Instructions Operator s Manual Follow generally accepted safety procedures in addition to the precautions specified in this section. The overall safety of any system incorporating this accessory is the responsibility of the assembler of the system. Symbols These terms and symbols may appear on the probe body or in this manual to alert you to important safety considerations. High Voltage WARNING, risk of electric shock or burn. CAUTION of potential damage to equipment, or WARNING of potential injury. Attend to the accompanying information to protect against personal injury or damage. Do not proceed until conditions are fully understood and met. DOUBLE INSULATION PROTECTIVE (EARTH) TERMINAL Precautions To avoid personal injury or damage to property, review and comply with the following safety precautions. Use product only as specified. Connect only to grounded instruments. Use only with compatible Teledyne LeCroy oscilloscopes that have their BNC input connected to an earth ground. Do not connect the probe reference lead to any point which is at a potential other than earth ground. Connect and disconnect properly. Connect probe to the oscilloscope before connecting the probe to the test circuit. Disconnect the probe input and reference lead from the test circuit before disconnecting the probe from the oscilloscope. To avoid injury or death due to electric shock, do not connect or disconnect probes or probe accessories while they are connected to a voltage source. 1

PP016 Passive Probe Do not overload; observe all terminal ratings. To avoid electric shock or fire, do not apply any potential to the probe leads that exceeds the maximum rating of the probe. Consult the respective oscilloscope product manual for further ratings information. Comply with voltage derating curve. When measuring higher frequency signals, comply with the Voltage vs. Frequency Derating Curve. Do not remove probe casing. Removing the probe s case or touching exposed connections may result in electric shock. Use only within operational environment listed. Use indoors only. Do not use in wet or explosive atmospheres. Keep product surfaces clean and dry. Use only accessories compatible with the probe. Handle with care. The probe tip is extremely sharp and may puncture skin or cause other bodily injury if not handled properly. Keep fingers behind the finger guard of probe body and accessories. Do not operate with suspected failures. Before each use, inspect the probe and accessories for any potential damage such as tears or other defects in the probe body, cable jacket, accessories, etc. If any part is damaged, cease operation immediately and sequester the probe from inadvertent use. 2

Introduction PP016 is a passive probe designed to be used with Teledyne LeCroy WaveAce oscilloscopes. Keep fingers behind the probe s finger guard during use. Operator s Manual Rated for indoor use only. Do not operate where conductive pollutants may be present. Maximum input voltage derates when frequency response is approximately 30 khz or higher. See voltage derating curve on p.4. Specifications Electrical Characteristics Attenuation 1:1 10:1 Bandwidth 10 MHz 300 MHz Input Resistance 1 MΩ 10 MΩ Input Capacitance 46 pf 12 pf Compensation Range NA 10 35 pf Electrical Ratings* Max. Input Voltage CAT II, 600 V (AC + DCpeak) Pollution Degree 2 * See Certifications for an explanation of rating categories. Operating Environment Temperature, Operating Temperature, Storage Altitude, Operating Humidity, Operating 0 o to 50 o C -20 o to 60 o C Up to 3000 m (9842 ft) 5% to 85% RH to 30 C 5% to 65% RH 30 C to 40 C 5% to 45% RH above 40 C 3

PP016 Passive Probe General Characteristics Cable Length Weight (probe only) Connector Type 1.2 m 54 g BNC Voltage Derating Curve (Max. V IN vs. Frequency) 4

Connectivity Accessories The following accessories are included standard with the PP016: QTY Standard Ground Lead 1 Sprung Hook 1 Color Coding Rings (set) 2 Adjustment Tool 1 Ground Attachment 1 Replacement Probe Tip 2 BNC Adaptor 1 IC Test Tip 2 Operator s Manual The Standard Accessory Replacement Kit for the PP016 probe is P/N PKIT3-5MM-101. 5

PP016 Passive Probe Use and Maintenance Cleaning The outside of the probe should cleaned with a soft cloth dampened with either deionized / distilled water or isopropyl alcohol. Allow the surface to dry completely before returning the probe to service. Never immerse the probe in any liquid. Probe Compensation Proper compensation of the probe is required to assure good amplitude accuracy in the dynamic portions of the waveform being measured. LF compensation matches the probe to differences in oscilloscope input capacitance. The LF compensation should always be checked and adjusted as needed when first connecting a passive probe to the oscilloscope input. HF compensation matches time constants within the probe to compensate for normal component tolerances. It is typically not necessary to adjust HF compensation unless the probe is being used with an oscilloscope with large differences in input characteristics than the oscilloscope model it was designed for. LF compensation is performed by connecting the input of the probe to a low frequency square wave, such as the oscilloscope calibrator signal set to 1 khz. The compensation is adjusted by rotating the adjustment accessible through the small hole in the center of the housing near the BNC connector. Use the tool supplied with the probe for this adjustment. Over-compensated, correct, and under-compensated waveforms 6

Operator s Manual Certifications Teledyne LeCroy certifies compliance to the following standards as of the date of publication. See the EC Declaration of Conformity shipped with the product for current certifications. EC Declaration of Conformity - Safety The probe meets intent of EC Directive 2014/35/EU for Product Safety. Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities: IEC/EN 61010-031:2015 Safety requirements for electrical equipment for measurement, control and laboratory use Part 031: Safety requirements for handheld probe assemblies for electrical measurement and test. Measurement Category II (CAT II) refers to measurements performed on circuits directly connected to utilization points (socket outlets and similar) of the low-voltage mains installation. Pollution Degree 2, operating environment where normally only dry non-conductive pollution occurs. Conductivity caused by temporary condensation should be expected. Environmental Compliance END-OF-LIFE HANDLING The probe is marked with this symbol to indicate that it complies with the applicable European Union requirements to Directives 2012/19/EU and 2013/56/EU on Waste Electrical and Electronic Equipment (WEEE) and Batteries. The probe is subject to disposal and recycling regulations that vary by country and region. Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles. For more information about proper disposal and recycling of your Teledyne LeCroy product, please visit teledynelecroy.com/recycle. RESTRICTION OF HAZARDOUS SUBSTANCES (ROHS) The probe and accessories conform to the 2011/65/EU RoHS2 Directive. 7

PP016 Passive Probe 2

928602-00 Rev A July, 2017