PME specialises in developing, implementing and maintaining solutions to the Mining industry.

Similar documents
EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

Welcome to the Session on. HT Distribution Network

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

EI HIGH VOLTAGE INSULATION TESTING POLICY

ECP HV INSULATION TESTING

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

ECP HV INSULATION TESTING

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

Industrial and Commercial Power Systems Topic 7 EARTHING

Education & Training

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

FAQ ON EARTHING STANDARDS 16/08/2018

RAPTOR Step and Touch Function

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

ACCESS TO HIGH VOLTAGE APPARATUS

ELECTRICAL EQUIPMENT. Inspection. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Specialists in HV and MV test and diagnostics. Testing in Substations

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

ELE-CMOS-E-2001 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

minecom The leader in Mine Communications

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Substation Preventive Maintenance

NSP/ 007 / 006 Guidance on Substation Design: Transformer Transport, Delivery and Installation

Turning the wheels of your success

DESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN

SUBJECT HEADING: Switching Programmes ISSUE: 18

HV Substation Earthing Design for Mines

TROUBLESHOOTING A TECHNICIAN S GUIDE 2ND EDITION. William L. Mostia, Jr., P. E. ISA TECHNICIAN SERIES

ECP GROUND-MOUNTED SWITCHGEAR WITH PROTECTION RELAYS COMMISSIONING PROCEDURE

Arc Flash Analysis Training

VI 3 - i TABLE OF CONTENTS

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

ET 40 - Electrician Theory Examination Marking Schedule

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

LV/MV/HV CIRCUIT BREAKERS (SWITCH GEAR) DESIGN, INSPECTION, MAINTENANCE, REPAIR & TROUBLESHOOTING

Protection of Electrical Networks. Christophe Prévé

ABB ph/orp analyzer and probe package

ECP DISTRIBUTION TRANSFORMER COMMISSIONING PROCEDURE

INSTRUMENTATION DESIGN ENGINEERING: Oil & Gas

Earthing Guidance Notes

A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

Guideline for Creating Disconnection Points and Establishing a Not Electrically Connected Area

Optimize Outage Management and Improve Underground System Reliability

Section 3. Test Procedures

Best Practice Reducing The Risk of Arc Flash Cross Over

Earthing for EMC in Installations

Customer Connection Guide Updates Effective May 2017

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

NZQA unit standard version 3 Page 1 of 5. Install and maintain telecommunications radio frequency systems

ELEC Transmission i and

SERVICING & METERING SERVICING AND METERING SECTION 5 SEC5:

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Pasteurizer Recorder and Recorder Controller

EE030: Circuit Breaker & Switchgears Inspection, Maintenance, Design, Repair & Troubleshooting

IMPORTANCE OF INSULATION RESISTANCE

Substation: From the Outside Looking In.

ELECTRICAL MAINTENANCE SKILLS

Electromechanical Technology /Electromechanical Engineering Technology CIP Task Grid

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Power Distribution System SVS18

Field Instruction Switching Activities. Purpose. Scope. Objective. Safety

PSSI 27 Work or Testing On or Near to High Voltage Direct Current (HVDC) Plant and Apparatus

WATERFLUX 3000 Quick Start

ADVANCED CIRCUIT BREAKERS OPERATION AND MAINTENANCE SECTOR / ENGINEERING TECHNICAL & CERTIFICATE OF ATTENDANCE TRAINING COURSE

FLANGE INTEGRITY MANAGEMENT

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

Be on guard for effective testing: Introduction

Technology Service Excellence. Training Overview

Guidance for UK Fire and Rescue Services. Dealing with incidents on or near National Grid high voltage overhead lines

Ultrasound Condition Monitoring

Electrical Measurement Safety. Sponsored By:

Industrial Mechanic (Millwright) Level 4

LINTER group - PARTNER COMPANIES

Licensed Electricians Practical Assessment (LEP)

WATERFLUX 3000 Quick Start

Control and Monitoring of Subsea Power Grid

COURSE PLANNER. Subject: TESTING AND COMMISSIONING OF ELECTRICAL EQUIPMENTS ( ) B.E. Fourth Year (8 th Sem) Branch Electrical Engineering

Earthing, HV Switching and Associated Operational Equipment. Approval: Chief Operating Officer

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

Distribution/Substation Transformer

Autotransformer Condition Monitoring Systems

INSTALLATION & TESTING OF UNDERGROUND PRIMARY AND SECONDARY POWER CABLES PRIOR TO ENERGIZATION

Single Line Diagram of Substations

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

Reference Number PDS 04 (RIC Standard: EP SP)

ECP GROUND-MOUNTED SWITCHGEAR COMMISSIONING PROCEDURE

SPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Basic Principles and Operation of Transformer

Canadian Technology Accreditation Criteria (CTAC) POWER SYSTEMS ENGINEERING TECHNOLOGY - TECHNICIAN Technology Accreditation Canada (TAC)

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

Istructions. Central control board for electromechanical gearmotors HERCULES 24V

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Transcription:

+675 325 3533 PME specialises in developing, implementing and maintaining solutions to the industry. Our Services: Engineering & design EPC services High voltage design, installations and testing Installation and maintenance of low, medium & high voltage electrical reticulation Reeling and trailing cable repairs as per AS1747 Submersible pump repairs and sales Fixed & mobile plant maintenance personnel Electrical switchboard manufacture On-site project management Construction and shutdown personnel Leaky feeder communications installation and maintenance DCS, SCADA and PLC programming and design and installation Asset Management / Maintenance Turn key design and construction Suppliers of Instrumentation and Process Control Equipment Telecommunications Hazardous Area installation works At PME you can be assured there are no gimmicks! We offer reliable service, quality products and knowledgeable, well trained staff,

Engineering & design First Step to Successful Completion PME believes that engineering is the first step on the road to successful completion of a project and its quality can greatly affect the final outcome regardless of project size. Our services cover all facets of the project life cycle from feasibility through to construction and plant upgrades. Our scope of services includes, but is not limited to the following: High Voltage Instrumentation and Control Automation and Motor Control Electrical Hazardous Area EPC services EPC stands for Engineering, Procurement, Construction and that is exactly what we like to provide at PME. Carrying out the detailed engineering design of the project, procuring all the equipment and materials necessary, and then constructing to deliver a functioning facility or asset to our clients. PME s Electrical Construction Division has been established in-country for over 40 years and has participated in all major marque projects in Port PME has also undertaken remote electrical construction projects throughout PNG with highly successful outcomes. PME provides procurement resources, processes, systems, market knowledge, and volume-leveraged pricing to maximise return-on-investment. High Voltage Fundamental to PME is the health and safety of all those involved and benefiting from our services. That s why every member of our high voltage (HV) team is certified with a nationally recognised HV Jointer licence. All our team members are highly trained in HV cable jointers and terminators, which includes PNG power trained personnel to perform HV terminations, jointing and very low frequency (VLF) testing.

Just within the HV area, we can provide you with: High Voltage termination up to 132KV on underground joints, aerial terminations, Ring Main Units and transformers Installation of underground HV cable and services Installation of transformers and Ring Main Units (RMU) Design and installation of earth grids Implementation of maintenance programs on transformers, switch gear and earthing systems Performing HV switching operations High voltage cable testing with 10KV Meggers, Hi-pot, and VLF testers, using PME s own equipment Cable identification and spiking Protection relay design & set up Cable Fault Location Installation and maintenance of low, medium & high voltage electrical reticulation Whether its reticulation of sub-divisions, installation of distribution transformers or service and maintenance of plant and equipment, PME can deliver these services in a professional and timely manner. Just within the HV area, we can provide you with: Installation of transformers pad mount or building type Installation of high voltage cables Installation of high voltage circuit breakers and switching stations including ABB, Schneider equipment High Voltage cable jointing Repair/replacement of high voltage equipment Upgrading of high voltage installations Perform audits to Australian Standard 2067 (Substation and high voltage Installations) on existing high voltage installations) High voltage testing on transformers/cables/switchgear VLF (Very Low Frequency) testing, Insulation Resistance testing to 10 kv and oil sampling testing Installation of earth mats Provide testing capabilities on earth mats step and touch voltages (ensuring safe working areas surrounding HV transformers) and soil resistivity testing Maintenance of high current LV circuit breakers and retrofitting of high current LV circuit breakers

High Voltage Maintenance Services Completing the total HV package for our customers we offer and recommend custom scheduled maintenance plans for your HV assets. If you don t have or are not sure if you require periodic maintenance of your High Voltage (HV) assets, please contact us. We can advise you free of charge what your legislative requirements are for your particular case. The regular servicing of HV equipment dramatically reduces high voltage faults that can occur on switch equipment and transformers. Some of the maintenance procedures we recommend are: Cleaning of HV switchgear Cleaning of HV insulators Thermal Imaging of connection points to ensure no hot spots are present. Wooden power pole testing and certification Soil resistivity, earth mat testing and installation Transformer oil sampling and testing and replacement. Switchyard vegetation management Asset auditing and inspections Power Services PME also offer low voltage power service work as well. This covers distribution and installation of 415 and 240 volt cables from high voltage equipment such as pad mounted transformers. Other services also include: Installation of LV (Low Voltage) Boards Installation of LV cables to LV Boards and main switchboards LV cable jointing Installation of turrets/cabinets including new subdivision works Repairs or extension to existing earth mats Reeling and trailing cable repairs Trailing and reeling cables are electrical power cables for mobile apparatus, such as large excavators, draglines, stackers and reclaimers. The cable allows the mobile apparatus to move without disconnecting its electric power supply. A reeling cable is specifically designed to be frequently reeled on and off a cable drum or reeler, such as an an iron ore rail-mounted reclaimer. Whereas, a trailing cable is specifically designed to be moved with the mobile apparatus, like a coal mine dragline or mineral sands mobile processing plant. Trailing and reeling cables pose an elevated safety risk, so as an example, a damaged trailing cable can lead to earthing faults and workers being exposed to electric shock hazards.

+675 325 3533 They require specific design mitigation measures, which are detailed in the Mines Safety and Inspection Regulations 1995. Submersible Pump Repairs and Sales pumps refer to the types of pumps required as part of the mining process. Slurry pumps, centrifugal pumps, magnetic drive pumps, submersible pumps, borehole pumps, diaphragm pumps and self-priming pumps are all used in the mining industry, depending on the fluid transfer and application needed. pumps work for abrasive sludge dewatering, mineral processing, slurry transfer, reagent (acid and chemical) dosing, water supply and boosting, and waste water and tailing transfer. Leaky feeder communication installation and repairs A leaky feeder communication system consists of a coaxial cable running along tunnels, which emit and receive radio waves, functioning as an extended antenna. The cable is leaky, in that it has gaps or slots in its outer conductor to allow the radio signal to leak into or out of the cable along its entire length. This leakage of signal means line amplifiers are required to be inserted at regular intervals, typically every 350 to 500 metres (380 to 550 yards), to boost the signal back up to acceptable levels. The signal is usually picked up by portable transceivers carried by personnel. Transmissions from the transceivers are identified by the feeder and carried to other parts of the tunnel, allowing two-way radio communication throughout the tunnel system. The system has a limited range, and because of the frequency it uses (typically VHF or UHF), transmissions cannot pass through solid rock, which limits the system to a line-of-sight application. It does, however, allow two-way mobile communication. At PME you can be assured there are no gimmicks! We offer reliable service, quality products and knowledgeable, well trained staff,

Instrumentation and Control At PME, we have established strong relationships with various manufacturers to supply instruments and equipment to our clients. Our company is built upon years of experiences, which enables us to help choose a manufacturer and model that is most suitable for your application. It will not only be reliable but the most cost-effective and high-quality option available. Our access to this vast range of equipment from a number of manufacturers guarantees that we can find solutions for our clients. Our services include: Temperature elements, including RTDs and thermocouples Temperature transmitters Pressure transmitters, gauge and differential Various flow transmitters, including magnetic, vortex and pitot tubes ph transmitters and probes Belt weighers (weightometers) Solids flow transmitters and impact weighers Valves and positioners Speed transmitters On-board weighing solutions Actuators Automation and Motor Control A leaky feeder communication system consists of a coaxial cable running along tunnels, which emit and receive radio waves, functioning as an extended antenna. The cable is leaky, in that it has gaps or slots in its outer conductor to allow the radio signal to leak into or out of the cable along its entire length. This leakage of signal means line amplifiers are required to be inserted at regular intervals, typically every 350 to 500 metres (380 to 550 yards), to boost the signal back up to acceptable levels. The signal is usually picked up by portable transceivers carried by personnel. Transmissions from the transceivers are identified by the feeder and carried to other parts of the tunnel, allowing two-way radio communication throughout the tunnel system. The system has a limited range, and because of the frequency it uses (typically VHF or UHF), transmissions cannot pass through solid rock, which limits the system to a line-of-sight application. It does, however, allow two-way mobile communication.

For automation and motor control we provide: PLC programming Operator interface/hmi/scada programming Motor/Servo motion control Troubleshooting & optimisation Industrial networking/communications Instrumentation Pneumatics/Hydraulic control Telemetry Data gathering and report generation Electrical For all facets of the electrical industry, PME provides detailed design services. Regardless of the industry that clients work in, PME is always able to assist in their engineering requirements. Our services include: PLC programming Front end engineering design (FEED) Conceptual design Preliminary design Detailed design Construction documents Specifications Bills of material Hazardous Area One of our specialities is inspections and installations of hazardous areas in electrical. PME has extensive experience from mining to oil and gas, defence and military, and chemical and food industries. All of our electricians have comprehensive training and experience in inspection and compliance of electrical installations in potentially explosive atmospheres. Using this industry knowledge and know-how, we offer our customers with unparalleled inspection programs, ensuring the integrity of equipment and systems. At PME, we can assist you in providing assurance that your company is complying with the latest international standards, codes and practices, and all legal obligations. Our cost-effective solutions to hazardous area installations and inspections have a minimum interruption to your daily business.