Agilent 8902A Measuring Receiver Product Note

Similar documents
Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 8902A Measuring Receiver

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent E8267C/E8257C/E8247C PSG

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Advanced Test Equipment Rentals ATEC (2832)

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Advanced Test Equipment Rentals ATEC (2832)

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Advanced Test Equipment Rentals ATEC (2832)

Agilent EPM Series Power Meters

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent 8761A/B Microwave Switches

Agilent E8247/E8257C PSG CW and Analog Signal Generators

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent PNA Series RF Network Analyzers

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent PNA Microwave Network Analyzers

Agilent E8267C PSG Vector Signal Generator

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent 87415A, 87400A Microwave Amplifiers

Base Station Installation and Maintenance

Agilent 83711B and 83712B Synthesized CW Generators

Advanced Test Equipment Rentals ATEC (2832)

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent 8510 Network Analyzer Product Note A

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Agilent 4-Port PNA-L Network Analyzers

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Product Note E5100A-2

Agilent 8560 E-Series Spectrum Analyzers

Agilent 8657A/8657B Signal Generators

Agilent PNA Microwave Network Analyzers

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 8920A RF Communications Test Set Product Overview

Advanced Test Equipment Rentals ATEC (2832) Agilent 8510 System Solutions

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Agilent 8752C RF Vector Network Analyzer

8 Hints for Better Spectrum Analysis. Application Note

expanding the possibilities

Improving TDR/TDT Measurements Using Normalization Application Note

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent 84904/5/8M Programmable Step Attenuators for Microwave and RF Manufacturing Test Systems

Agilent 83430A Lightwave Digital Source Product Overview

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent 4285A Precision LCR Meter

Agilent PNA Microwave Network Analyzers

Agilent PN Testing amplifiers and active devices with the Agilent 8510C Network Analyzer. Product Note

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Agilent 6800 Series AC Power Source/Analyzer

6 Tips for Successful Logic Analyzer Probing

E-series E9300 Average Power Sensor Specifications

MDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0

Agilent 8901B Modulation Analyzer (150 khz 1300 MHz) and Agilent 11722A Sensor Module (100 khz 2600 MHz) Four Instruments In One

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

PXIe Contents CALIBRATION PROCEDURE

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Reconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth

Agilent Technologies 3000 Series Oscilloscopes

Agilent N4373B Lightwave Component Analyzer Testing advanced 40Gb/s components with highest relative and absolute accuracy

External Source Control

9 Hints for Making Better Measurements Using RF Signal Generators. Application Note 1390

Wavelength Calibration for the 8614X Series Optical Spectrum Analyzers. Product Note

Agilent CSA Spectrum Analyzer

Introduction. Part 1. Introduction...2

HP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One

ME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price.

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

Transcription:

Agilent 8902A Measuring Receiver Product Note Operation of the Agilent 8902A Measuring Receiver for Microwave Frequencies When you are performing microwave frequency power measurements, the Agilent Technologies 11793A microwave converter extends the superb measurement performance of the 8902A measuring receiver to microwave frequencies. To make measurements on signals from 10 MHz to 1300 MHz, just enter the input signal frequency on the measuring receiver. For input signals above 1300 MHz the signals must be downconverted by the 11793A microwave converter to a usable IF frequency before any measurements can be made by the measuring receiver. An external local oscillator (LO) provides the correct frequency and amplitude level to the microwave converter for down conversion. The 11793A requires +8 dbm leveled output from the LO. For LO s with insufficient power above 18 GHz, the 11793A offers an optional 10 to 26.5 GHz amplifier. Using the following instructions you can select and set the correct LO mixing frequency on the external LO and make all necessary measurements on your device-undertest (DUT), including low level power measurements down to 100 dbm.

Setting up the External LO and Measuring Receiver When the DUT s signal is greater than 1300 MHz, you must down convert microwave signals to the frequency range of the measuring receiver by setting the correct external LO frequency and amplitude, and informing the measuring receiver (using special functions) what the external LO settings are. For each input signal frequency change greater than ±100 MHz, you must also change the frequency of the external LO to maintain the correct down conversion process. See Figure 1 for connection details. Selecting the LO frequency We recommend you select an LO frequency that is 120.53 MHz higher than the DUT s input signal. This is the ideal IF frequency (Agilent 11793A IF output to the input on the measuring receiver) for measurement accuracy. For example, if the input signal to be measured is 1800 MHz, use an LO of 1920.53 MHz (1800 + 120.53 = 1920.53 MHz). If the external LO cannot be set 120.53 MHz higher than the DUT s signal due to a minimum LO frequency range of 2000 MHz, use one of the following frequencies, if possible, for optimum measurement performance (added to the test frequency): 240.53, 480.53, 600.53, or 680.53 MHz. These frequencies are recommended because they are half-way between the measuring receiver s internal LO octave bands. For example, if the input signal to be measured is 1800 MHz, you can use an LO of 2040.53 MHz (1800 + 240.53 = 2040.53 MHz). The lower the IF frequency, the better the performance. Any IF frequency between 10 MHz and 700 MHz can be used. Set up the external LO for the correct level: +8 dbm for LO frequencies <18 GHz (11793A standard or with options) +7 dbm for LO frequencies >18 GHz (11793A standard) +0 dbm for LO frequencies >18 GHz (11793A Option 001, 011, or 021) Setting up the measuring receiver for RF measurements Press FREQ, then the green AUTOMATIC OPERA- TION key, to clear any previous keys. Enter 27.3 SPCL, the LO frequency in MHz, and then press the MHz key. If measuring signals <1300 MHz, press the 27.3 SPCL, 0 key, then the MHz key. This tells the measuring receiver that the external LO is not needed; or you may enter 27.0 SPCL to exit Frequency Offset Mode. If the DUT s signal is < 15 dbm, enter the DUT s frequency, and then press the MHz key to manually tune. Repeat the previous two steps if the DUT s frequency is changed more than ±100 MHz. Select a measurement key on the measuring receiver (except RF POWER) to perform the desired measurement. To perform RF POWER measurements, perform the setup in the following section. Frequency Offset Control: 27.0 SPCL to exit Frequency Offset Mode 27.1 SPCL to re-enter Frequency Offset Mode 27.2 SPCL to display the External LO frequency 27.3 SPCL to Enter/Enable the External LO 2

Setting up the Measuring Receiver for RF Power Measurements The calibration factors listed on the sensor head of the Agilent 11722A or 11792A sensor module must be loaded into the measuring receiver s Normal and Frequency Offset Cal Factor tables before you can perform any RF power measurements. If you enter a digit incorrectly while following these instructions just press the CLEAR key and re-enter that step. Normal cal factor table entry instructions Enter 37.9 SPCL (clears all cal factor storage tables). Press the RF POWER key. The instrument will display Error 15 indicating no Cal Factors stored. Enter 37.3 SPCL, and the REF CF value, then press the BLUE key, then the MHz key. This is the Reference Cal Factor (REF CF). Figure 1. Agilent 8902A Microwave Measurement Interconnections 3

Setting up the Measuring Receiver for RF Power Measurements (continued) Enter 37.3 SPCL, the frequency in MHz, then press the MHz key. Enter the Cal Factor % for this frequency, then press the BLUE key, then the MHz key. Repeat the previous step for each Frequency and related Cal Factor shown on the sensor head. Press the green AUTOMATIC OPERATION key to reset the instrument. Frequency offset cal factor table entry instructions Enter 27.1 SPCL to enter Frequency Offset Mode. Press the RF POWER key. The instrument will display Error 15 indicating no Cal Factors stored. Enter 37.3 SPCL and the REF CF value, then press the BLUE key, then the MHz key. This is the Reference Cal Factor (REF CF). Enter 37.3 SPCL, the frequency in MHz, then press the MHz key. Enter the Cal Factor % for this frequency, then press the BLUE key, then the MHz key. Repeat the previous step for each Frequency and related Cal Factor shown on the sensor head. Verification of the cal factor tables Press the Blue key, then the AUTOMATIC OPERATION key to do an instrument preset. Press the RF POWER key. If you get Error 15 repeat the Entry Instructions shown on page 3. Enter 37.5 SPCL, then press the BLUE key, then the MHz key. If the REF CF shown is incorrect, repeat the first three entry instructions for the correct Cal Factor Table Entry Instructions presented in the previous section. Enter 37.6 SPCL then press the BLUE key, then the khz key. This will display the next frequency in the table; then press the BLUE key, then the MHz key to display the related cal factor. Repeat the previous step to view all entered frequencies and related cal factors. To repeat viewing of the table, enter 37.5 SPCL to start over. To clear the table and start over, enter 37.9 SPCL. To correct any Cal Factor % errors, perform the Cal Factor Entry Instructions only for the frequency and cal factor in error. If a frequency is entered incorrectly, perform Cal Factor Entry Instructions, and enter the frequency in error with a cal factor of zero (0). This will erase the frequency from the table. Press the green AUTOMATIC OPERATION key to reset the instrument. 4

Performing RF power measurements with a sensor module Connect the sensor to the RF POWER, CALI- BRATION port on the measuring receiver. Press the ZERO key, to zero the sensor. After a few seconds 0.00 W is displayed. Press the CALIBRATE key, to calibrate the sensor. A reading will be displayed. Press the BLUE key, then the CALIBRATE key, to save the reference calibration level (SAVE CAL). 1.000 mw should now be displayed. Press the CALIBRATE key again to turn off the calibrator. The measuring receiver is now calibrated. Measure power levels by pressing RF POWER. If sensor modules are changed, perform the zero and calibrate steps again. Re-calibrate the sensor when ambient conditions change or approximately every 8 hours. Low-Level RF Power Measurements The calibration factors listed on the sensor head of the Agilent 11722A or 11792A sensor module must be loaded into the measuring receiver s Normal and Frequency Offset Cal Factor tables to be able to perform any low-level RF power measurements. See the previous sections if this has not been done. The sensor module also must be zeroed and calibrated as described in the previous section. Lowlevel power measurements can only be performed on a CW signal without modulation. Setting up the measuring receiver for low-level power measurements Set the DUT to the desired frequency, set the amplitude to at least 5 dbm. Turn OFF all modulation. Tune to the DUT s frequency as described in the previous section Setting up the External LO and Measuring Receiver. Press the GOLD key (shift), then the TUNED RF LEVEL key. Press the BLUE key and the khz key to view the DUT s frequency at any time. The display will clear in approximately 5 seconds and return to the previous reading. Press the LOG/LIN key for a display of dbm or watts. Enter 1.9 SPCL to insure that 10 db of attenuation will always be inserted to improve any mismatch uncertainty, or enter 1.0 SPCL for auto RF input attenuation and gain selection. 5

Low Level RF Power Measurements (continued) The display should show a power reading, the RECAL and the UNCAL annunciators should be lit along with the f OFS (frequency Offset) annunciator (if tuned to a frequency >1300 MHz). The UNCAL annunciator light indicates that the current tuned RF level absolute power measurement is uncalibrated. The RECAL light prompts the user to calibrate. Press the CALIBRATE key. Calibration may take several seconds. Once a reading is displayed and the RECAL light is no longer displayed, continue. Reduce the DUT s signal level in 10 db steps. You should see a reading at each stepped level. Each time the RECAL annunciator light comes on, press the CALIBRATE key (see previous step). Continue this process until 100 dbm is reached. You need to calibrate approximately three times. Now that the three calibration factors for this frequency have been generated, any power level may be measured between +0 dbm and 100 dbm without further calibration. Setting up the measuring receiver for low-level power measurements on drifting signals This measurement technique is preferred when you are testing for level accuracy on non-synthesized, or free running signal sources that have tendencies to drift in frequency. The Track Mode feature (Special Function 32.9) is used to keep the measuring receiver locked onto drifting signals. When using the Track Mode feature, if the measuring receiver loses the drifting signal, increase the signal to 80 dbm or higher, then press the BLUE key, then the CLEAR key to retune the measuring receiver to the drifting signal, then continue with your measurement. Set the DUT to the desired frequency, set the amplitude to at least 5 dbm. Turn OFF all modulation. Tune the measuring receiver to the DUT s frequency as described in the previous section, Setting up the External LO and Measuring Receiver. Enter 32.9 SPCL. The TRACK MODE key light should be on. (This is the same as entering 4.4 SPCL, 8.1 SPCL, Log units, Track Mode, and 27.3 SPCL.) Press the MHz key to enter manual tune tracking mode. Press the GOLD key (shift), then the TUNED RF LEVEL key. Press the Blue key and the khz key to view the DUT s frequency at any time. The display will clear in approximately 5 seconds and return to the previous reading. Press the LOG/LIN key for a display of dbm or Watts. Enter 1.9 SPCL to insure that 10 db of attenuation will always be inserted to improve any mismatch uncertainty, or enter 1.0 SPCL for auto RF input attenuation and gain selection. 6

The display should show a power reading, the RECAL and the UNCAL annunciators should be lit, along with the f OFS (frequency Offset) annunciator (if tuned to a frequency >1300 MHz). The UNCAL annunciator light indicates that the current tuned RF level absolute power measurement is uncalibrated. The RECAL light prompts the user to calibrate. Press the CALIBRATE key. Calibration may take several seconds. Once a reading is displayed and the RECAL light is no longer displayed, continue. Reduce the DUT s signal level in 10 db steps. You should see a reading at each stepped level. Each time the RECAL annunciator light comes on, press the CALIBRATE key (see previous step). Continue this process until 100 dbm is reached. You should need to calibrate three times. Now that the three calibration factors for this frequency have been generated, any power level may be measured between +0 dbm and 100 dbm without further calibration. Other useful information when setting up the measuring receiver for low-level power measurements The three calibration factors for a frequency can be saved in non-volatile memory in one of the eight STORE/RECALL registers. To store these cal factors for a frequency in register one, press the BLUE key, then the STORE, 1 keys. Calibration factors for other frequencies can now be made and recalled when needed, by pressing the BLUE key, then the RECALL, (corresponding register) keys. The calibration remains valid for any CW signal at that frequency ±5% (or ±10 MHz (±5 MHz in Track Mode), whichever is smaller). In Tracking Mode, if the DUT s frequency drifts past one of the following frequency boundaries, the measuring receiver will lose the signal and the measurement process must be restarted: 40 MHz, 80 MHz, 160 MHz, 320 MHz, and 640 MHz. Higher resolution for db measurements can be attained by using 32.0 SPCL for a resolution of 0.01 db or 32.1 SPCL for a resolution of 0.001 db. If Error 15 is displayed, you need to enter the cal factors printed on the sensor module. If Error 31 or 33 is displayed, the sensor module needs to be zeroed and calibrated. Refer to the 8902A Operation and Calibration Manual for more detailed descriptions and other useful functions. See the "Tuned RF Level" section under the "RF Power" and "Level" tab and the "Frequency Offset Control" section under the "Additional Capabilities" tab. 7

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, outof-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test and measurement needs. Online Assistance www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 452 4844 Canada: (tel) 1 877 894 4414 (fax) (905) 206 4120 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Australia: (tel) 1 800 629 485 (fax) (61 3) 9210 5947 New Zealand: (tel) 0 800 738 378 (fax) (64 4) 495 8950 Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Product specifications and descriptions in this document subject to change without notice. Copyright 1985, 2000 Agilent Technologies Printed in U.S.A. 9/00 5968-6296E For more information visit our Web site at: www.agilent.com/find/wireless