State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Similar documents
ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

APPENDIX B: Generation Interconnection Application Form

PART 1 OWNER/APPLICANT INFORMATION

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

Distributed Generation Application Form (Generation of Greater than 20 kw to 15 MW)

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

Form B. Connection Impact Assessment Application Form Distribution System

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Impact Assessment Generator Form

Initial Application Form for Connection of Distributed Generation (>10kW)

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

Connection Impact Assessment Application Form

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form

Connection Impact Assessment Application

Embedded Generation Connection Application Form

Generation Interconnection Study Data Sheet Synchronous Machines

440 (12) 416 (12) 416 (12) 440 (12)

TABLE OF CONTENT

Generator Advanced Concepts

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Generation Interconnection Requirements at Voltages 34.5 kv and Below

S0L1-J1 - Technical Data Sheet

E N G I N E E R I N G M A N U A L

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

GENERATOR DATA JANUARY 30, 2015

PI734A - Technical Data Sheet

WDG 12 - Technical Data Sheet

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Generation and Load Interconnection Standard

Spec Information. Reactances Per Unit Ohms

Conventional Paper-II-2013

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

WDG 13 - Technical Data Sheet

The Connecticut Light and Power Company

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

WDG 61 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 51 - Technical Data Sheet

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

S4L1S-D4 Wdg.17 - Technical Data Sheet

WDG 12 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

Utility Interconnection and System Protection

Industrial Electrician Level 3

QUESTIONNAIRE for Wind Farm Power Stations only

Thyristorised Automatic Power Factor

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

TAL 044 Low Voltage Alternator - 4 pole

Transformer Factory Testing

PARTNER ALTERNATORS LSA 40-4 Pole

TAL 049 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole

LOAD BEHAVIOUR DURING VOLTAGE DIPS: A VOLTAGE QUALITY STUDY IN LOW VOLTAGE DISTRIBUTION SYSTEM

Sizing Generators for Leading Power Factor

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Spec Information. Reactances Per Unit Ohms

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Generation and Load Interconnection Standard

Wind Power Facility Technical Requirements CHANGE HISTORY

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

ELG2336 Introduction to Electric Machines

PAPER-II (Subjective)

SYNCHRONOUS MACHINES

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

INVESTIGATION INTO THE POWER QUALITY AND RELIABILITY OF SUPPLY IN THE INDUSTRIAL NETWORKS WITH DISTRIBUTED GENERATION

APPENDIX A MATLAB CODE FOR CALCULATION OF MOTOR TORQUE

Unit 29 Three-Phase Transformers

Harmonic control devices

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

TECHNICAL GUIDELINE FOR THE INTERCONNECTION OF DISTRIBUTED ENERGY RESOURCES TO EPCOR DISTRIBUTION AND TRANSMISSION INC. S DISTRIBUTION SYSTEM

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

EH2741 Communication and Control in Electric Power Systems Lecture 2

Apprentice Electrical Technician Test (ETT) Preparation Guide

Transcription:

Engineering data submittal Page 1 WHO SHOULD FILE THIS SUBMITTAL : Anyone in the final stages of in terconnecting a Generation System with Otter Tail Power. This submittal shall be completed and provided to Otter Tail Power s Generation Interconnection Coordinator during the design of the Generation System, as established in the Otter Tail Power's State of North Dakota Interconnection Process for Distributed Generation Systems. INFORMATION: This submittal is used to document the interconnected Generation System. The Applicant shall complete as much of the form as applicable. The Applicant will be contacted if additional information is required. OWNER / APPLICANT Company / Applicant: Representative: Phone Number: FAX Number: Title: PROPOSED LOCATION OF GENERATION SYSTEM INTERCONNECTION Street Address, Legal Description or GPS coordinates: PROJECT DESIGN / ENGINEERING (if applicable) Company: Representative: Phone: FAX Number: ELECTRICAL CONTRACTOR (if applicable) Company: Representative: Phone: FAX Number: TYPE OF INTERCONNECTED OPERATION Interconnection / Transfer method: Open Quick Open Closed Soft Loading Inverter Proposed use of generation: (Check all that may apply) Peak Reduction Standby Energy Sales Cover Load Duration Parallel: None Limited Continuous Pre-Certified System: Yes / No (Circle one) Exporting Energy Yes / No (Circle one)

Engineering data submittal Page 2 GENERATION SYSTEM OPERATION / MAINTENANCE CONTACT INFORMATION Maintenance Provider: Phone #: Pager #: Operator Name: Phone #: Pager #: Person to Contact before remote starting of units Contact Name: Phone #: Pager #: 24hr Phone #: GENERATION SYSTEM OPERATING INFORMATION Fuel Capacity (gals): Full Fuel Run-time (hrs): Engine Cool Down Duration (Minutes): Start time Delay on Load Shed signal: Start Time Delay on Outage (Seconds): ESTIMATED LOAD The following information will be used to help properly design the interconnection. This Information is not intended as a commitment or contract for billing purposes. Minimum anticipated load (generation not operating): kw: kva: Maximum anticipated load (generation not operating): kw: kva: REQUESTED CONSTRUCTION START/COMPLETION DATES Design Completion: Construction Start Date: Footings in place: Primary Wiring Completion: Control Wiring Completion: Start Acceptance Testing: Generation operational (In-service):

Engineering data submittal Page 3 (Complete all applicable items, Copy this page as required for additional generators) SYNCHRONOUS GENERATOR (if applicable) Unit Number: Total number of units with listed specifications on site: Type: Phases: 1 or 3 Serial Number (each) Date of manufacture: Speed (RPM): Freq. (Hz); Rated Output (each unit) kw Standby: kw Prime: kva: Rated Power Factor (%): Rated Voltage(Volts): Rated Current (Amperes): Field Voltage (Volts): Field Current (Amperes): Motoring Power (kw): Synchronous Reactance (Xd): % on kva base Transient Reactance (X'd): % on kva base Subtransient Reactance (X"d): % on kva base Negative Sequence Reactance (Xs): % on kva base Zero Sequence Reactance (Xo): % on kva base Neutral Grounding Resistor (if applicable): I 2 t or K (heating time constant): Exciter data: Governor data: Additional Information: INDUCTION GENERATOR (if applicable) Rotor Resistance (Rr): Stator Resistance (Rs): Rotor Reactance (Xr): Stator Reactance (Xs): Magnetizing Reactance (Xm): Short Circuit Reactance (Xd"): Design Letter: Frame Size: Exciting Current: Temp Rise (deg C ): Rated Output (kw): Reactive Power Required: k Vars (no Load) kvars (full load) If this is a wound-rotor machine, describe any exter nal equipment to be connected (resistor, rheostat, power converter, etc.) to rotor circuit, and circ uit configuration. Describe ability, if any, to adjust generator reactive output to provide power system voltage regulation. Additional Information: PRIME MOVER (Complete all applicable items) Unit Number: Type: Serial Number: Date of Manufacture: H.P. Rated: H.P. Max: Inertia Constant: lb.-ft. 2 Energy Source (hydro, steam, wind, wind etc.):

Engineering data submittal Page 4 INTERCONNECTION (STEP-UP) TRANSFORMER (If applicable) kva: Date of Manufacture: Serial Number: High Voltage: kv Connection: delta wye Neutral solidly grounded? Low Voltage: kv Connection: delta wye Neutral solidly grounded? Transformer Impedance (Z): % on kva base Transformer Resistance (R): % on kva base Transformer Reactance (X): % on kva base Neutral Grounding Resistor (if applicable) TRANSFER SWITCH (If applicable) Model Number: Type: Rating(amps): INVERTER (If applicable) Model: Rated Power Factor (%): Rated Voltage (Volts): Rated Current (Amperes): Inverter Type (ferroresonant, step, pulse-width modulation, etc.): Type of Commutation: forced line Minimum Short Circuit Ratio required: Minimum voltage for successful commutation: Current Harmonic Distortion Maximum Individual Harmonic (%): Maximum Total Harmonic Distortion (%): Voltage Harmonic Distortion Maximum Individual Harmonic (%): Maximum Total Harmonic Distortion (%): Describe capability, if any, to adjust reactive output to provide voltage regulation: NOTE: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms. POWER CIRCUIT BREAKER (if applicable) Model: Rated Voltage (kilovolts): Rated Ampacity (Amperes): Interrupting Rating (Amperes): BIL Rating: Interrupting Medium (vacuum, oil, gas, etc.) Insulating Medium (vacuum, oil, gas, etc.) Control Voltage (Closing): (Volts) AC DC Control Voltage (Tripping): (Volts) AC DC Battery Charged Capacitor Close Energy (circle one): Spring Motor Hydraulic Pneumatic Other Trip Energy (circle one): Spring Motor Hydraulic Pneumatic Other Bushing Current Transformers (Max. ratio): Relay Accuracy Class: CT S Multi Ratio? (circle one); No / Yes: (Available taps):

Engineering data submittal Page 5 MISCELLANEOUS (Use this area and any additional sheets for applicable notes and comments) SIGN OFF AREA This Engineering Data Submittal documents the equipment and design of the Generation System. We agree to supply Otter Tail Pow er with an updated Engineering Data Submittal any time significant changes are made in the equipment used or the design of the proposed Generation Sy stem. The Applicant agrees to design, operate and maintain the Generation Sy stem within the requirements set forth by the Otter Tail Power's State of North Dakota Distributed Generation Interconnection Requirements. Applicant Name (print): Applicant Signature: Date: SEND THIS COMPLETED & SIGNED ENGINEERING DATA SUBMITTAL AND ANY ATTACHMENTS TO OTTER TAIL POWER S GENERATION INTERCONNECTION COORDINATOR