AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Similar documents
PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PART # mA Positioner

AMC mA Positioner

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

TMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

FEATURES OPTIONAL FEATURES

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

AD-8100 & AD-8200 Servo Amplifiers

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Sealed Interface Control: EC20300

SPECIFICATION, CONTROLS AND ACCESSORIES

658 Current to Position Converters

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

DynaDrive INFORMATION MANUAL SDFP(S)

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

DR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION

Dynamo Brushless DC Motor and GreenDriveTM Manual

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Installation & Operating Instructions

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Potentiometer Control EC20200

AE-504. Solid Start Paralleling Relay General Instructions OPERATIONS. Parallel. Control. Manual DEVICE INPUT OUTPUT

Copyright 2014 by Minarik Drives

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Digital Interface Card DEC005000

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

SPECIFICATION, CONTROLS AND ACCESSORIES

BC145 SIGNAL ISOLATOR BOARD

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

LA-5000 SERIES LINEAR VALVE ACTUATORS

Manual SCA-SS V /02 page 1

MODEL AT-10 ANALOG TRANSMITTER

Technical Instructions Document No EA GQD June 23, OpenAir

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

HLC-1000 High-limit Humidity Control

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Contents NUDRIVE ACCESSORY USER GUIDE

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

Current Loop Interface Module M 2025D

CONTENTS XV300K GB r doc XV300K 2/13

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

WATT TRANSDUCER. Instruction Manual

USER S MANUAL PROCESS CONTROL MODULE PCM3

PM124 Installation Instructions. See important note about revisions of this board on the last page.

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Using the VR448 in place of the Marathon DVR 2000

Installation Tech Note Dallas, Texas

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

IB6 Series Solid-State Isolation Relay

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

PHASE CUT SIGNAL DRIVERS

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

PM24 Installation Instructions

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

MODEL KBWD-15 Pulse Width Modulated (PWM)

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

EE283 Laboratory Exercise 1-Page 1

G201X STEP MOTOR DRIVE REV 5: SEPTEMBER 13, 2010

Rev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.

2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE. Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor.

B MTS Systems Corp., Model Function Generator

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

Non-Spring Return EconoDrive Proportional Actuator

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Microprocessor Control Board Set Up Procedures (OR PLC)

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Installation and Operating Manual

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

SCA-SS (70V, 10A)

Variable Transformers Product Design & Engineering Data

Spring Return DuraDrive Proportional Actuator

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Refer to the drawing on page 2 to familiarize yourself with the connectors and controls on the

MMP SA-715A SERVO AMPLIFIER

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

Bill of Materials: PWM Stepper Motor Driver PART NO

SETUP and OPERATING MANUAL ADVANCED MULTI-CHANNEL VEHICLE INTERCOM SYSTEM (AMCVIS)

Installation, Operation and Maintenance Manual

Overview. Features. Specifications. Important Notes

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Compact Motorized Actuator

VALVCON V Series Actuator. 115VAC and 230VAC

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

G210X STEP MOTOR DRIVE REV 5: March 25, 2011

Transcription:

The Indelac / AC Motor Controllers are used for proportional positioning of split phase AC actuator motors. An external command signal of 0-0V, -V, or -0mA can be used to compare to a feedback signal from a potentiometer. The open or closed AC output will energize, which powers the actuator motor, until the feedback signal matches the command signal, at which time the controller's AC output is turned off and the actuator motor stops. With a loss of command signal in the -V or the -0mA input range, the / offers three useful options: fail in place, the open output on, or the closed output on. All input and output options are easily field configurable with jumper plugs. The only other ad-justments consist of Deadband and non-interactive Zero and Span trimmers, which allows for easy field calibra-tion. These controllers are available in versions for VAC ±0%, VAC ±0%, or VAC ±0% power and give the user optical isolation between the input signal and the AC outputs. The unit includes a red LED indica-tor (for the open output), a green LED indicator (for the closed output), an on-board fuse, and two removable screw terminal strips (for easy servicing). The (VAC), B ( VAC), and D(VAC) are mounted on Snaptrack and deliver A at 0 C. Subsequently, the ( VAC), B (VAC), and D (VAC) are mounted on an aluminum extrusion and can deliver A at 0 C. All six versions are available with standoff mounts only (insulating sheet is included) which allows the units to be mounted directly to the actuator housing or bracket. Note, the housing or bracket is re-quired for heatsinking the A, C, and E A units. B D AC Motor Controllers B D A C E A C E ADDITIONAL FEATURES Multiple units are easily connected in parallel to a common command signal. Built-in utility power supplies for powering a command pot, -0mA input or output transmitter, and the feedback potentiometer. No external motor resistors are required. Indelac Controls, Inc.

/ J J OUTLINE SNAPTRACK.".".0".0" 0." JP JP RED LED (open) JP JP GREEN LED (close) RED LED (open) JP JP GREEN LED (close) FUSE VAC, A B VAC, A D VAC, A J FUSE.0" DEADBAND J DEADBAND JP ZERO SPAN JP ZERO SPAN 0." # CLEAR HOLE () PLACES." ALUMINUM EXTRUSION # CLEAR HOLE () PLACES ELECTRICAL CONNECTIONS to Motor OPEN OUTPUT NEUTRAL CLOSE OUTPUT GND WIPER +0V to Feedback Pot to AC Power L NEUTRAL L LINE EARTH GND SIGNAL GND ( ) -V / -0mA (+) 0-0V +0V +V to J J.0".0" 0." 0.0" VAC, A B VAC, A D VAC, A J J 0." INSULATING SHEET INPUT SIGNAL RANGE 0-0V -V -0mA INPUT SIGNAL JP JUMPER PLUG INSTALL REMOVE INSTALL."." 0." 0." JP RED LED (open) JP JP GREEN LED (close) FUSE.0" JP DEADBAND ZERO SPAN # CLEAR HOLE () PLACES.0" LOSS OF INPUT SIGNAL OUTPUT STATE BOTH OFF OPEN ON CLOSE ON JUMPER PLUG JP JP JP 0." A VAC, A C VAC, A A VAC, A C VAC, A E VAC, A E VAC, A 0." NOTE: Do not install JP, JP, or JP when using the 0-0V input signal range. Power must be off when installing these jumpers. Indelac Controls, Inc.

/ BLOCK DIAGRAM J OPEN OUTPUT LIMIT SWITCH NOTE: See input signal configurations for more information. +V OUTPUT +0V OUTPUT 0-0V INPUT -V / -0mA INPUT SIGNAL GND EARTH GND L LINE L NEUTRAL J POWER / SIGNAL ACTUATOR MOTOR NEUTRAL CLOSE OUTPUT GND THERMAL SWITCH LIMIT SWITCH OPEN CLOSE optional brake coil WIPER OPEN FEEDBACK POT +0V DESCRIPTION The / AC Motor Controllers come in various configurations to accommodate many applications. Basically three parameters should be considered in selecting the appropriate model: motor current, operating voltage, and package configuration (see Outline information). The controllers are rated for A motors and are available for either VAC, VAC, or VAC operation. The, B, and D come mounted on snaptrack while the A, AMC- 00C, and E have standoffs for direct mounting to a bracket (insulating sheet is included). The controllers are rated for A motors and also come in VAC, VAC, or VAC versions. The, B, and D are packaged on an aluminum extrusion. The A, C, and AMC- 0E come with standoff mounts - these units require screw mounting through all four standoffs to a suitable metal plate or bracket in order to provide sufficient heatsinking for the unit. CAUTION! These units are intended to be mounted in an appropriate enclosure to avoid electrical shocks. High voltages are present on the outside of the unit when power is applied. AC power should be disconnected prior to any wiring of these units. A heater and thermostat should be used where condensation may occur. Indelac Controls, Inc.

/ POWER / SIGNAL (J) Power is connected to pins,, and as shown in the block diagram above. The fuse installed on the unit is rated for maximum output current that can be safely delivered by the AC outputs. Replacement fuses must not exceed these maximum ratings (A for the controllers and A for the controllers) to prevent damage to the unit. Smaller fuse sizes can be used with smaller motors - consult the actuator manufacturer for appropriate fuse size and type. An appropriate command signal, either 0-0V, - V, or -0mA, should be connected to pin or (as shown in the Block Diagram) while using pin as the return signal ground. The / must be configured for the type of command signal that is to be used - jumper plug JP must be installed whenever a - 0mA or 0-0V input is used (see Outline). Pin of J provides an auxiliary +0V output which can be used to connect a command potentiometer. By connecting one end of a potentiometer to pin, the other end to pin, and the wiper to pin, a local control knob can be implemented. Pin provides an auxiliary +VDC output which can be used to power an input or output -0mA transmitter. ACTUATOR (J) The actuator and feedback potentiometer are connected to J as shown in the block diagram. Pin should be connected to the motor winding that moves the actuator toward the open position, and conversely, pin is connected to the winding that moves the actuator toward the closed position. Pin is the neutral or common wire to the motor windings. The / is suitable for powering most dynamic brakes used with electric actuators; however, consult the actuator manufacturer for more information. The feedback potentiometer wiper must be connected to pin of J. One end of the potentiometer is connected to pin, and the other is connected to pin. The potentiometer should be connected so that when the actuator moves towards the open position, the potentiometer's resistance between pins and will increase. This can also be measured as a voltage - the voltage between pins and should increase when the actuator moves towards the open position. If the potentiometer is wired incorrectly, the typical response of the unit will be to run the actuator to the full open or closed position (the appropriate output indicator will remain on) regardless of the command signal input. The feedback potentiometer should be mounted to provide a proper feedback signal through the entire range between the open and closed positions. For best results, position the actuator to the midway point between the open and closed positions; then adjust the feedback potentiometer for approximately VDC (or / of the potentiometer's resistance) between pins and of J. Since the feedback potentiometer is crucial for proper operation of the /, the following items should be carefully observed: - Potentiometer resistance should be a value from K to 0K ohms. - The potentiometer should be a linear taper type. - The potentiometer must be properly wired to provide the correct feedback signal. - The potentiometer must be properly and securely mounted in order to provide a reliable feedback signal. OUTPUT INDICATORS The / units have on-board indicators that identify when one of the motor outputs is turned on. When the open output is turned on, the red LED indicator will turn on, and when the close output is turned on the green LED indicator will turn on (see Outline). Many actuators are equipped with limit switches at the open and closed positions which are intended to disconnect power to the motor to prevent mechanical damage. For this reason, it is possible that the AMC- 00/ will indicate that one of the motor outputs is turned on when the actuator is not in motion. However, it should be noted that when the indicator is on, power is applied to the motor output. LOSS OF INPUT SIGNAL When the -V or -0mA type command signal is used, the / can detect that the input signal has been disconnected. The unit can be configured to respond to the loss of command signal in one of three ways: turn both outputs off (leaving the actuator in its last position at the time signal was lost), turn on the open output (to move the actuator to the full open position), or turn on the close output (to move the actuator to the full closed position). To select the desired response to a loss of input signal, install jumper plug JP, JP, or JP as shown in the Outline information. CAUTION! Power must be disconected when installing or removing these jumpers - damage to the unit may occur if these jumpers are set with power on. Indelac Controls, Inc.

/ When using this feature, certain precautions should be observed. For applications using the 0-0V input signal type, the unit cannot detect a loss of signal; do not install jumper plugs JP, JP, and JP for these applications. When JP or JP are installed, the unit will turn on one of the motor outputs when the input signal is lost; if the actuator does not use limit switches, these selections should not be used. CALIBRATION The non-interactive zero and span adjustments of the / allow for easy calibration once the unit is installed. After insuring that the feedback potentiometer and motor outputs are wired to provide a proper feedback signal, as described under "ACTUATOR (J)", follow these steps to calibrate the unit (see Outline for the location of the adjustments): - Apply AC power to the unit, and set the command input signal to minimum: 0V for 0-0V input type V for -V input type ma for -0mA input type - Adjust the "Zero" adjustment so that the actuator moves to the desired closed position. If the desired position cannot be achieved, check that the feedback potentiometer provides a feedback signal as described under "ACTUATOR (J)"; also, check the position of the limit switches. - If the actuator is hunting for position, turn the "Deadband" adjustment clockwise until hunting stops. If the actuator is not hunting for position, turn the "Deadband" adjustment counterclockwise until the actuator begins to hunt; then turn the "Deadband" adjustment slightly clockwise until hunting stops. WARNING! Actuator failure may occur if the "Deadband" adjustment is set to allow continuous hunting. This can cause excessive wear of motor bearings, geartrain, dynamic brake, and feedback potentiometer. Hunting can also cause the internal temperature of the actuator housing to rise to a level that exceeds the maximum rating of the /, 0 o C. - Set the command signal input to maximum: 0V for 0-0V input type V for -V input type 0mA for -0mA type - Adjust the "Span" adjustment so that the actuator moves to the desired open position. If the desired position cannot be achieved, check the position of the limit switch. NOTE: The "Zero" adjustment is an offset setting rather than an absolute setting. Should the "Zero" adjustment be changed, the "Span" adjustment should be checked for the desired open position. Setting of the "Span" adjustment has no affect on the "Zero" adjustment. - To check proper operation and linearity, set the command signal to halfway: V for 0-0V input type V for -V input type ma for -0mA input type Verify that the actuator's position is midway between the open and closed positions. REVERSE ACTING CALIBRATION When converting a direct acting actuator to a reverse acting actuator, two changes in wiring must be made: - Reverse the feedback potentiometer wires connected to J- and J-. - Reverse the motor output wires connected to J- and J-. NOTE: DO NOT reverse the input signal polarity. Also, make sure that both wiring changes are made - if only one is made, the actuator will run to either full open or full closed. After the wiring changes have been made, refer to CALI- BRATION for setting the zero and span adjustments. Indelac Controls, Inc.

/ SPECIFICATIONS POWER REQUIREMENTS, A,, A: VAC ±0%, 0/0 Hz B, C, B, C: VAC ±0%, 0/0 Hz D, E, D, E: VAC ±0%, 0/0 Hz. VA typical (not including output load) Fuse Type: x: A AG Slo-Blo x: A AG Slo-Blo COMMAND SIGNAL INPUT 0-0 VDC Input Input Impedance: K ohms minimum External Command Potentiometer: K ohm - VDC Input Input Impedance: M ohms minimum Loss of Command Threshold: 0.V -0 ma Input Input Impedance: 0 ohms ±% Loss of Command Threshold: ma FEEDBACK SIGNAL INPUT Input Voltage: 0 to 0 VDC External Feedback Potentiometer: K ohm to 0K ohms POWER SUPPLY OUTPUTS Input or Output Transmitter Power (J-): VDC @ 0mA max Command Potentiometer Power (J-): 0VDC @ 0mA max NOTE: Do not connect these outputs to other power supplies. AC MOTOR OUTPUTS Off-state Leakage Current: <ma Maximum Load Current @ 0 o C: x: A x: A (when properly mounted) CONTROL ADJUSTMENTS Zero: adjustable throughout feedback signal range Span: adjustable throughout command signal range Deadband: adjustable from 0.% to.% of span ENVIRONMENTAL Operating Temperature Range: 0 o C to 0 o C Storage Temperature Range: -0 o C to o C Relative Humidity Range: 0 to 90 % (noncondensing) Indelac Controls, Inc.

/ WIRING DIAGRAMS Input Configurations MLT-00A (includes dial and knob) J- +V RED J- -V / -0mA J- SIGNAL GND Sourcing or Sinking output J- -V / -0mA CW XMA-0A WHT -0mA Transmitter 0K ohm Command Pot BLK -0mA Input using a self-powered transmitter Remote Command Pot using the -0mA Input J- 0-0V J- SIGNAL GND 0-0V DAC J- +0V J- 0-0V J- SIGNAL GND SHEILD CW POT-0 Command Pot (K ohm only) 0-0V Input using digital-to-analog card Command Pot using the 0-0V Input Indelac Controls, Inc.

/ WIRING DIAGRAMS Special Applications -0mA Command Connect up to 0 controllers J- J- -0mA # Remove JP on all other units. Install JP on one unit. J- J- -V #9 J- J- -V #0 Controlling multiple units using a single -0mA signal -0mA Command Calibrate unit # to open and close with to ma, and unit # to open and close with to 0 ma. Note, the ratio between the feedback pot rotation to the actuator shaft rotation must be :. J- J- -0mA Install JP # J- J- -V Remove JP J- J- J- J- J- J- # Motor NOTE: Limit switches must be used to stop actuator travel! Motor Split range control Indelac Controls, Inc.