Unit 2. Single Line Diagram of Substations

Similar documents
Single Line Diagram of Substations

Substation: From the Outside Looking In.

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

CONTENTS. 1. Introduction Generating Stations 9 40

Notes 1: Introduction to Distribution Systems

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

ESB National Grid Transmission Planning Criteria

A TRAINING REPORT ON UTTAR PRADESH POWER CORPORATION LIMITED 33/11 KV SUBSTATION INDIRANAGAR SECTOR-25, LUCKNOW(UTTAR PRADESH).

SCHEME OF COURSE WORK ( ) Electrical & Electronics Engineering. Electrical machines-i, II and power transmission engineering

Computer Aided Electrical Drawing Laboratory Manual. Table of Contents

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

EH2741 Communication and Control in Electric Power Systems Lecture 2

Saturday-Sunday Training Report

Busbars and lines are important elements

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

3. (a) List out the advantages and disadvantages of HRC fuse (b) Explain fuse Characteristics in detail. [8+8]

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

A short introduction to Protection and Automation Philosophy

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

ELEC Transmission i and

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY

EI HIGH VOLTAGE INSULATION TESTING POLICY

ELECTRICAL POWER ENGINEERING

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

SWITCH YARD OPERATION IN THERMAL POWER PLANT(KaTPP Jhalawar Rajasthan)

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Substation Preventive Maintenance

Hamdy Faramawy Senior Application Specialist ABB Sweden

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

How to maximize reliability using an alternative distribution system for critical loads

Functional Specification Revision History

BUS2000 Busbar Differential Protection System

Protection of Electrical Networks. Christophe Prévé

# - - Internal * On Line Examination

Table of Contents. Introduction... 1

EAST WEST UNIVERSITY

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

Power systems Protection course

INTEGRATED TRANSMISSION PLAN Glossary

ABB AG - EPDS. I S -limiter The worldʼs fastest limiting and switching device

SYNCHRONISING AND VOLTAGE SELECTION

Fatima Michael college of Engineering and Technology

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

High voltage engineering

Electrical Engineering. Power Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications

Education & Training

EDS EHV NETWORK DESIGN

Lecturer: Dr. J B E AL-ATRASH No. of Pages: 4

SLD FOR 132/33 KV DUB STATION, SOMANATHPUR

Comparison of recloser and breaker standards

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

MV network design & devices selection EXERCISE BOOK

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

INVESTIGATION OF ENERGY LOSS IN A TRANSMISSION SUBSTATION USING ONITSHA 330/132KV AS A CASE STUDY F.O. Enemuoh, T.L. Alumona and C.H.

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Transmission Facilities Rating Methodology for Florida

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

CIGRE WG A3.06 Reliability of High Voltage Equipment Intermediate Results CIGRE WG A3.06. Reliability of High Voltage Equipment

Electrical Power Systems

Southern Company Interconnection Requirements for Inverter-Based Generation

ECP HV INSULATION TESTING

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Transmission Availability Data System Definitions

GUJARAT TECHNOLOGICAL UNIVERSITY, AHMEDABAD, GUJARAT COURSE CURRICULUM COURSE TITLE: SWITCHGEAR & PROTECTION (COURSE CODE: )

PIPSPC. Prepared by Eng: Ahmed Safie Eldin. And. Introduction. Protection Control. Practical. System. Power

STANDARDS/MANUALS/ GUIDELINES FOR SMALL HYDRO DEVELOPMENT

Voltage Detectors. Voltage Detectors Voltage Detectors

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Transmission Facilities Rating Methodology

INSTRUMENT TRANSFORMERS. Product Spectrum

ECP HV INSULATION TESTING

SUBJECT HEADING: Switching Programmes ISSUE: 18

East-South HVDC Interconnector II, India : in commercial operation since 2003

Module 10. Initiation Code RELIABILITY ACCOUNTABILITY

ELECTRICAL POWER TRANSMISSION TRAINER

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 4 NOVEMBER 2009

Cutler-Hammer January 1999

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

HVDC High Voltage Direct Current

Electrical Description

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Utility Interconnection and System Protection

2015 Relay School Bus Protection Mike Kockott March, 2015

This document covers common questions concerning the design of an effectively grounded system.

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Modeling insulation in high-voltage substations

ATTACHMENT - AESO FUNCTIONAL SPECIFICATION

1 Fundamentals of Protection Fuse and Circuit Breakers Protective Relays Protection of Generators and Transformers 08

I -limiter The world s fastest switching device

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Substation Design Volume VII

Transcription:

Unit 2 Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission lines are used to transmit the electric power from the generating stations to the load centers. Between the power generating station and consumers a number of transformations and switching stations are required. These are generally known as substations. Substations are important part of power system and form a link between generating stations, transmission systems and distribution systems. It is an assembly of electrical components such as bus-bars, switchgear apparatus, power transformers etc. Their main functions are to receive power transmitted at high voltage from the generating stations and reduce the voltage to a value suitable for distribution. Some substations provide facilities for switching operations of transmission lines, others are converting stations. Substations are provided with safety devices to disconnect equipment or circuit at the time of faults. Substations are the convenient place for installing synchronous condensers for the purpose of improving power factor and it provide facilities for making measurements to monitor the operation of the various parts of the power system. The substations may be classified in according to service requirements and constructional features. According to service requirements it is classified in to transformer substations, switching substations and converting substations. (1) Transformer substations: Majority of the substations in the power system are in the type. They are used to transform power from one voltage level to another voltage level. Transformer is the main component in such substations. Transformer substations are further classified into Step-up substations, Primary grid substations, Secondary substations and Distribution substations. (a) Step-up substations: These substations are usually located at the generating stations. Generating voltage of the order of 11kV needs to be stepped up to a primary transmission voltage level of the order of 220kV or 400kV. (b) Primary grid substations: These substations are located at the end of primary transmission lines and the primary voltage is stepped down to suitable secondary voltages of the order of 66kV or 33kV. (c) Secondary substations: The voltage is further stepped down to 11kV. Large consumers are supplied power at 11kV. (d) Distribution substations: These substations are located near the consumer localities to supply power at 400V, three phase or 230V, single phase to the consumers. (2) Switching substations: These substations are meant for switching operations of power lines without transforming the voltage. Different connections are made between the various transmission lines. (3) Converting substation: Such substations are meant for either converting AC to DC or vice versa. Some are used to change the frequency from higher to lower or vice versa for industry utilisations. 1

According to constructional features substations are classified into Indoor substations, Outdoor substations, Underground substations and Pole mounted substations. (1) Indoor substations: All equipments of the substation are installed within the station buildings. (2) Outdoor substations: All equipments such as transformers, circuit breakers, isolators, etc., are installed outdoors. (3) Underground substations: In thickly populated areas where the space is the major constraint, and cost of land is higher, under such situation the substations are laid underground. (4) Pole mounted substations: This is an outdoor substation with equipments installed overhead on a H pole or 4 pole structure. Single Line Diagram Any complex power system even though they are three phase circuits, can be represented by a single line diagram, showing various electrical components of power system and their interconnection. In single line representation of substation the electrical components such as power transformers, incoming and outgoing lines, bus-bars, switching and protecting equipments, are represented by standard symbols and their interconnections between them are shown by lines. Single line diagrams are useful in planning a substation layout. Some of the standard symbols used to represent substation components are given in Table below. Sl Electrical components Symbols No 1 AC Generator 2 Bus Bar 3 Power transformer -Two winding 4 Three winding transformer 2

5 Current Transformer (CT) 6 Voltage transformer or Potential transformer (PT) 7 Circuit Breaker (CB) 8 Circuit breaker with isolator 9 Isolator or Group Operating Switch(GOS) 10 Lighting Arrestor (LA) Or 11 Earth Switch (ES) 13 Wave or Line trap 3

14 Coupling Capacitor (CC) Power transformers: Power transformers are used generation and transmission network for stepping-up the voltage at generating station and stepping-down the voltage for distribution. Auxiliary transformers supply power to auxiliary equipments at the substations. Current transformers (CT): The lines in substations carry currents in the order of thousands of amperes. The measuring instruments are designed for low value of currents. Current transformers are connected in lines to supply measuring instruments and protective relays. For example a 100/1A CT is connected in a line carrying 100A, and then the secondary current of CT is 1A. Potential transformers (PT): The lines in substations operate at high voltages. The measuring instruments are designed for low value of voltages. Potential transformers are connected in lines to supply measuring instruments and protective relays. These transformers make the low voltage instruments suitable for measurement of high voltages. For example a 11kV/110V PT is connected to a power line and the line voltage is 11kV then the secondary voltage will be 110V. Circuit breaker (CB): Circuit breakers are used for opening or closing a circuit under normal as well as abnormal (faulty) conditions. Different types of CBs which are generally used are oil circuit breaker, air-blast circuit breaker, vacuum circuit breaker and SF 6 circuit breaker. Isolators or Isolating switches: Isolators are employed in substations to isolate a part of the system for general maintenance. Isolator switches are operated only under no load condition. They are provided on each side of every circuit breaker. Lightning arresters (LA): Lightning arresters are the protective devices used for protection of equipment from lightning strokes. They are located at the starting of the substation and also provided near the transformer terminals. Earth switch: It is a switch normally kept open and connected between earth and conductor. If the switch is closed it discharges the electric charge to ground, available on the uncharged line. Wave trap: This equipment is installed in the substation for trapping the high frequency communication signals sent on the line from remote substation and diverting them to the telecom panel in the substation control room. 4

Coupling capacitor: A coupling capacitor is used in substations where communication is done by AC power line. It offers very low impedance to high frequency carrier signal and allows them to enter the line matching unit and blocks the low frequency signal. Bus-bar: When number of lines operating at the same voltage levels needs to be connected electrically, bus-bars are used. Bus-bars are conductors made of copper or aluminum, with very low impedance and high current carrying capacity. Different types of bus-bar arrangements are single bus bar arrangements, single bus-bar with sectionalisation, double bus-bar arrangements, sectionalised double bus-bar arrangement, double main and auxiliary bus-bar arrangement, breaker and a half scheme/1.5 Breaker scheme, and ring bus-bar scheme. Single bus-bar arrangement: It consists of single bus-bar. Both incoming and outgoing lines are connected to the single bus-bar. The advantages of this arrangement are low maintenance, low initial cost and simple operation. The drawback of this arrangement is if any repair work is to be done on bus-bar, complete system get interrupted. Figure below shows that three incoming and three outgoing line are connected to the single bus arrangement. 5

Single bus-bar with sectionalisation: Single bus-bar is divided into sections. Any two sections are connected by circuit breaker and isolators. During fault or maintenance particular section can be de-energised. This eliminates complete shutdown of the system. Figure below shows that two incoming and two outgoing lines are connected bus section 1 and other two incoming and two outgoing lines are connected bus section 2. 6

Double bus-bar arrangements: This arrangement is also known as duplicate bus-bar system. It consists of two bus-bars main and spare of same capacity. Incoming line and outgoing lines can be connected to either bus by means of bus coupler breaker and isolators. Continuity of supply to the circuit can be maintained during maintenance of main bus-bar or fault occurring on it. Figure below shows that three incoming lines and three outgoing lines are connected to either bus by a bus coupler. 7

8

Problem 1 Draw the Single Line Diagram of a generating substation having the following main equipments: i) Alternators: Five, 100MW, 11kV, 3, Y connected, 50Hz ii) Step-up transformers: Five, 100MVA, 11/220kV, /Y,3,50Hz iii) Bus: 220kV-Double bus with a bus coupler iv) Outgoing lines: Five, 220kV v) Station auxiliary transformers: Two, 5MVA, 11kV/400V, /Y,3,50 Hz Show the positions of CTs, PTs, isolating switches, lightning arresters, circuit breakers. 9

Problem 2 Draw the one line diagram of a substation having the following equipmentsi) Incoming lines: Two, 220kV ii) Outgoing Lines: Five, 66kV,One 11kV iii) Bus-bars: 220 kv-double bus, 66kV-Double bus, 11kV bus iv) Transformers: (a) Three winding transformers-two,100mva, 220/66/11kV, 3 (b) Auxiliary transformer-one, 5MVA,11kV/400V, 3 v) Wave trap, Coupling condenser and Earth switch at incoming lines Show the positions of CTs, PTs, disconnecting switches, lightning arresters, circuit breakers. 10

Problem 3 Draw the single line diagram of a substation having the following equipments: i) Incoming lines: Two,110kV ii) Outgoing lines: (a) One, 110kV (b)four, 11kV iii) Transformers: (a) Two,10MVA,110/11kV, /Y (b) One, 2MVA,11kV/415V,Y/Y iv) Bus-bars: 110kV-Duplicate bus-bar,11kv single bus-bar Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers. 11

Problem 4 Draw the single line diagram of a 66/11kV substation having the following equipments: i) Two transformers 66/11kV,5MVA, /,3Phase ii) 66kV double bus-bar with bus coupler, 11kV single bus with sectionalisation iii) Two incoming lines 66kV iv) Two outgoing lines 66kV v) Eight outgoing lines at 11kV distributed equally Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers. 12

Problem 5 Draw the single line diagram of a 33/11kV substation having the following equipmentsi) Incoming line: One, 33kV ii) Outgoing lines: Six, 11kV iii) Transformers- (a) One, 9MVA, 33/6.4/0.695kV, /Y/Y (b) Two, 6.3MVA, 33/11kV, /Y Show the positions of CTs, PTs, isolators, lightning arresters, circuit breakers. 13

Problem 6 Draw the single line diagram of a Pole Mounted Substations 14