IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Similar documents
IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product data sheet

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

C B. Models. Models 2MOPP

NFF Series. CoolX600 NFF Series Cool. Patent Pending Resonant Technology. NFF Series; No Fan Featured

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Electrical Specifications

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

Electrical Specifications

VOF XX - XXX - X

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Cool. NFF Series. CoolX600 NFF Series. Patented Resonant Technology. NFF Series; No Fan Featured

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Cool. NFF Series. CoolX600 NFF Series. Patent Pending Resonant Technology. NFF Series; No Fan Featured

CoolX CoolPac. CoolPac Slots Power. CoolX CoolMod. Vnom (V) CoolModel. Single Output Modules (1 Slot) High Power Modules (3 Slot)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PDAM500 Series 500W Power Supply

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

General. Environmental. EMC & Safety

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

MB120S 120W Single Output Medical Series

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

TB65 65W Single Output Test and Measurement/Industrial Series

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

150 Watt Industrial (WLT)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

VMS-300A - XX - XXX - X

Watts HCP Series

LB115S 115W Single Output

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Doc. EA Model Number:

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

General. Environmental. EMC & Safety

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

TE60 60W Single Output External Power Test & Measurement/Industrial Series

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

TE60 60W Single Output External Power Test & Measurement/Industrial Series

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Industrial Serie +600S

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

For more information, please visit the product page. output. output current max (A)

LFWLP W 12V 15.00A 25.00A 92%

TE W Single Output External Power Test & Measurement/Industrial Series

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

CCH400 & CCH600 Series

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) TERMINAL BLOCK Frequency Hz, Nominal 50/60

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

Medical Grade AC/DC Power Supply With PFC

Output Voltage (Vfan) & Current

TE90 90W Single Output External Power Test & Measurement/Industrial Series

NV /180/200 Watts AC/DC Flexible Power Solution

Product Specification sheet

Transcription:

IMA 400 Watts Power Supply Series for medical and industrial applications Product data sheet

400 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial and IT Wide operating input voltage range: 80 Vac to 275 Vac or 120 Vdc to 300 Vdc Wide adjustable output voltage range (+/- 20%) 5 Vdc standby output High efficiency: up to 94% Size: 4 x 6.96 x 1.6 in (1U design) Low acoustic noise level of less than 30 db(a) Active current sharing 2 MOPP PMBus compatible for control, programming and monitoring 500,000 hour MTBF Optional conformal coating 3 years warranty Model variants Model number Input voltage range Main DC Output Auxiliary DC Output Remote ON/OFF AC DC Voltage Current Voltage Current standard (Vac) (Vdc) (Vdc) (A) (Vdc) (A) setting 2) IMA-x400-12-ZNPLI IMA-x400-12-ZNPLY IMA-x400-24-ZNPLI IMA-x400-24-ZNPLY IMA-x400-48-ZNPLI IMA-x400-48-ZNPLY 80 to 275 120 to 300 12 33.3 24 16.7 48 8.33 IMA-x400: x = S for standard version (e.g. IMA-S400-24-ZNPLY), x = C for conformal coated version (e.g. IMA-C400-24-ZNPLY) 2) Model ZNPLI and ZNPLY have different settings for Remote ON/OFF, see Other features, p. 4 5 0.5 OFF ON OFF ON OFF ON AC/DC input (J IMA-x400-12 IMA-x400-24 IMA-x400-48 Nominal input voltage 100 Vac to 240 Vac AC operating input voltage range 80 Vac to 275 Vac Nominal input frequency 50 / 60 Hz Input frequency range 47 Hz to 63 Hz DC Input voltage range 120 Vdc to 300 Vdc Maximum input current 6 A at 80 Vac / 3.8 A at 120 Vdc Efficiency @ 100% load see Fig. 16 to Fig. 18, page 11 @ 230 Vac 92% 94% 94% @ 115 Vac 90% 92% 92% Max inrush current < 20 A Input fuse DC input compliant, dual 10 A fuses used Power factor 2) 0.9 (typical) Hot and cold turn on 2) EN 61000-3-2, Class A compliant 2

Main DC output (J2) IMA-x400-12 IMA-x400-24 IMA-x400-48 Nominal output voltage 12 V 24 V 48 V Output voltage adjustment range 9.6 V to 14.4 V 19.2 V to 28.8 V 38.4 V to 56.0 V Maximum output power Output voltage regulation 400 W Total 2.25% Over line Full input range, full load 0.25% Over load Over temperature Nominal input, full load range Nominal input, full load, full temperature Maximum output current 33.3 A 16.7 A 8.3 A Maximum output capacitive load 10,000 µf Dynamic load regulation < 5% PARD (20 MHz) 2) 1% 1% < 1% peak to peak Turn on overshoot < 2% Output rising time Hold up time Start up time < 150 ms 20 msec nominal AC OFF --> ON Nominal input, max. load < 2.5 s REMOTE OFF --> ON Nominal input, max. load < 150 ms Output over voltage protection Output over current protection Short circuit protection Over temperature protection Remote sense 3) Total voltage drop compensation for +V_SENSE and -V_SENSE connections (J3 Pins 13 and 14) to the output load YES, latch mode 15 V to 17.5 V 30 V to 35 V 58.5 V to 63 V YES, at 108% to 140% of nominal output current; auto recovery YES, auto recovery YES, auto recovery 200 mv 50% step from 5% load,1 A/µs, 10 µf Tan and 1µF ceramic capacitor 2) 10 µf Tan and 1µF ceramic capacitor 3) Do not short or reversely connect +V_SENSE and -V_SENSE. Doing this can cause damage to the power supply Auxiliary DC output (J3) Connector type Molex, Part number 87833-1420, 14 pin, see Fig. 19, page 12 Nominal output voltage Output voltage adjustment range Output voltage regulation Total 2.25% Over line Full input range, full load 0.25 % Over load Nominal input, full load 1% range Over temperature Nominal input, full load, 1% full temperature Maximum output current 0.5 A Maximum output capacitive load 1,000 µf Output over voltage protection Yes, at 5.5 V to 6 V, latch mode Output over current protection Yes, at 1.0 A to 1.3 A, auto recovery Short circuit protection YES, auto recovery Over temperature protection YES, auto recovery 5 V 3

Galvanic isolation Input to Output Reinforced 4000 Vac; 2 x MOPP Input to Case Basic 1500 Vac; 1 x MOPP Output to Case Basic 1500 Vac; 1 x MOPP Leakage currents AC Leakage current from Input to earth ground Measured at mains voltage at 60 Hz at 63 Hz Normal condition (low line) 132 Vac < 150 µa < 150 µa Single fault condition (low line) 132 Vac < 250 µa < 260 µa Normal condition (high line) 264 Vac < 300 µa < 300 µa Single fault condition (high line) 264 Vac < 500 µa < 520 µa AC Leakage current from Output to earth ground Measured at mains voltage Typical at 60 Hz Maximum value at 63 Hz Limit per IEC 60601-1 Normal condition 264 Vac 45 µa < 60 µa 100 µa Single fault condition (neutral open) 264 Vac 45 µa < 80 µa 500 µa Single fault condition (ground open) 264 Vac 114 µa < 150 µa 500 µa AC Backdrive fault 264 Vac < 450 µa < 550 µa 5000 µa Meets IEC 60601-1 BF leakage current limit Other features Current Share Bus Pin J3 Pin 11 (CURRENT SHARE_V) Power Good Pin J3 Pin 9 (PWR_GOOD) Green LED Derating Guideline OR-ing SDA, SCL for I2C Voltage at CS Pin will vary linearly with load current on main output, and will be 6 V at rated load current, when the output voltage is at its rated value. Open collector. As soon as AC input voltage and DC output voltage are in the predefined range, the PWR_GOOD signal is set to HIGH. Will turn ON as soon as PWR_GOOD signal is set to HIGH Refer to IPC 9592B and Delta Internal Guideline Redundant operation with active circuit sharing, see Application Note Redundant operation, p. 10 Internal 10 kω pull-up resistor to internal 3.3 V Remote On/Off Pin J3 Pin 10 (REMOTE ON/OFF) REMOTE ON/OFF (J3 Pin 10) and 5VSB_RTN (J3 Pin 3 or J3 Pin 4 or J3 Pin 7) -ZNPLI Main DC Output REMOTE ON/OFF (J3 Pin 10) and 5VSB_RTN (J3 Pin 3 or J3 Pin 4 or J3 Pin 7) -ZNPLY Main DC Output Shorted OFF Shorted ON Open ON Open OFF Logic can be switched with PMBus 4

Environmental conditions IMA-x400-12 IMA-x400-24 IMA-x400-48 Ambient operating temperature range -20 C... +70 C (-4 F to +158 F) (see Fig. 7 to Fig. 8, page 10) Ambient storage temperature range Output power derating Versus input voltage -40 C... +85 C (-40 F to +185 F) When AC input voltage is < 90 Vac, the output power will be reduced by 4 W per 1 V. (see Fig. 9, page 10) Versus ambient temperature (see Fig. 9, page 10) (see Fig. 8, page 10) Output current derating Versus output voltage When output voltage is > 12 Vdc, the output current is reduced by 2.292 A per 1 V (see Fig. 10, page 10). Relative humidity 2) Operating altitude -200 Shock test (non-operating) Vibration (non-operating) < 95% (non-condensing) When output voltage is > 24 Vdc, the output current is reduced by 0.583 A per 1 V (see Fig. 11, page 10). m to 5,000 m (-650 ft to 16,400 ft) When output voltage is > 48 Vdc, the output current is reduced by 0.148 A per 1 V (see Fig. 13, page 1. IEC 60068-2-27 compliant, 50 g, 11 msec, 3 shocks for each direction IEC 60068-2-6 compliant, 2.09 Grms, 5 Hz to 500 Hz, 20 minutes per side (3 planes) Pollution degree 2 Ambient operating temperature decreases by 1 C per 305 m (1000 ft) altitude increase 2) Maximum operating altitude requirements for different types of products, see Safety standards and directives, p. 6 Reliability CMTBF Expected capacitor life time 2) Warranty 500,000 hours 10 years 3 years Telecordia SR-332, Issue 3, 25 C, 90% confidence level 2) Nominal input voltage, 45 C, 80% load 5

EMC Radiated emissions Conducted emissions Power line harmonics Applied standards EN 55011, EN 55022 and FCC, Class B EN 55011, EN 55022 and FCC, Class B EN 61000-3-2, Class A Criteria Voltage flicker EN 61000-3-3 ESD EN 61000-4-2, level 4, 8 kv contact, 15 kv air A Radiated immunity EN 61000-4-3, level 3, 10 V/m A Electrical fast transient EN 61000-4-4, level 4, ±4 kv A Surge immunity EN 61000-4-5, level 4, 2 kv DM, 4 kv CM A Conducted RF immunity EN 61000-4-6, level 3, 10 Vrms A Power frequency magnetic field EN 61000-4-8, level 3, 10 A/m A Voltage dips and sags EN 61000-4-11, 30%, 500 ms EN 61000-4-11, 60%, 100 ms EN 61000-4-11,100%, 10 ms EN 60601-1-2, 30%, 500 ms EN 60601-1-2, 60%, 100 ms EN 60601-1-2, 100%, 10 ms EN 60601-1-2, 100%, 5000 ms A B A A B A B Ring wave EN 61000-4-12, level 3, 1 kv DM, 2 kv CM A Voltage fluctuations EN 61000-4-14, Class 3 A Power Supply Unit inside a dummy system Safety standards and directives IEC/EN 60950-1, Edition 2 and all national deviations IEC/EN 60601-1, Edition 3 (tested against Edition 2, too) and all national deviations Protection class UL 60950-1/CSA 22.2 No 60950-1, Edition 2; 5,000 m (16,400 ft) altitude, 120 V to 300 Vdc and 100 V to 240 ±10% Vac (UL File E191395) IEC 60601-1(2005), EN60601-1(2006) ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008); 3,000 m (9,800 ft) altitude, 100 V to 240 Vac ±10% (UL File E325662) I Designed to support Type B Applied Part End Product Requirements Ecological characteristics WEEE (Waste Electrical and Electronic Equipment Directive) RoHS (Restriction of Hazardous Substances Directive) 2012/19/EU 2011/65/EU 6

Mechanical data Dimensions (L x W x D) Weight Indicator Cooling system AC/DC input port Main DC output port Auxialary DC output + signals port Noise 176.8 x 101.6 x 40.6 mm (6.96 x 4 x 1.6 in) 0.960 kg (2.12 lb) Green LED System airflow cooling or natural convection cooling Block M3.5 x 3 pins Block M5 x 2 pins Connector x 14 pins < 30 db(a) At 1 Hz to 20 khz and a distance of 1 m. Test conditions: 100 Vac, 100% load, ambient temperature 30 C (86 F) Options Model Main Output voltage Standby Output Leakage current Main Output adjustable Open frame U channel Enclosed Convection cooling Fan Fan, airflow from end to front Fan, airflow from front to end Top FAN solution Active current sharing Remote ON/OFF Coated IMA-S400-12V 12 V 5 V/0.5 A 300 µa - IMA-S400-24V 24 V 5 V/0.5 A 300 µa - IMA-S400-48V 48 V 5 V/0.5 A 300 µa - IMA-C400-12V 12 V 5 V/0.5 A 300 µa IMA-C400-24V 24 V 5 V/0.5 A 300 µa IMA-C400-48V 48 V 5 V/0.5 A 300 µa included on request - not available 7

Mounting orientations Fig. 1: Standard mounting orientation Connector side Bottom Top Top Bottom Fig. 2: Vertical mounting Fig. 3: Mounting on the left side Fig. 4: Mounting on the right side Bottom view Side view Mounting holes Mounting holes Connector side Mounting holes Fig. 5: Position of the mounting holes 8

Dimensional drawings 176.8 mm +0.5 +0.02-0.5 (6.96 in -0.02) 101.6 mm +0.5 +0.02-0.5 (4.0 in -0.02 ) J2 VR LED J1 J3 PIN1 PIN2 M3*0.5 screw hole (2x) both sides 20.0 mm (0.79 in) 40.6 mm +0.5-0.5 +0.02 (1.60 in -0.02 ) 155.0 mm (6.10 in) 15.0 mm (0.59 in) 144.5 mm (5.69 in) 17.0 mm (0.59 in) 80.0 mm (3.15 in) 10.8 mm (0.42 in) M3*0.5 screw hole (4x) Fig. 6: Dimensional drawing Notes: Base plate mounting, M3 thread holes, maximum penetration 4.0 mm (0.16 in) (from outside face of chassis), maximum torque 0.6 Nm (5.31 lb-in) (J Input terminal block, Switchlab T14-EMII03, M3.5 screw in 3 positions, maximum torque1.3 Nm (11.5 lb-in) (J2) Output terminal block, Dinkle DT-7C-B01W-3943-02, M4 screw in 2 positions, maximum torque 1.5 Nm (13.28 lb-in) (J3) Signal connector and Auxiliary DC Output, Mating connector for J3 is either Molex, part number 51110-1450 (without locking ramp), or Molex part number 51110-1451 (with locking ramp). The connector is not shipped with the power supply unit. General tolerance: ±0.3 mm (0.012 in) 9

Curves IMA-x400-12 Tested at 90 Vac input Output power [W] 400 IMA-x400-24/48 Tested at 90 Vac input Output power [W] 400 290 300 200 200 100 100 0 40 50 60 70 Ambient temperature [ C] 0 40 55 70 Ambient temperature [ C] Airflow > 0.8 m/s Natural convection Airflow > 0.8 m/s Natural Convection Fig. 7: Output power versus ambient temperature 12 V Fig. 8: Output power versus ambient temperature 24/48 V IMA-x400-12 Output power [%] Output current [A] 100 90 33.3 27.8 80 90 275 Input voltage [Vac] 9.6 12 14.4 Output voltage [Vdc] Fig. 9: Output power versus input voltage Fig. 10: Output current versus output voltage 12 V IMA-x400-24 IMA-x400-48 Output current [A] Output current [A] 16.7 13.9 8.33 7.14 19.2 24 28.8 Output voltage [Vdc] Fig. 11: Output current versus output voltage 24 V 38.4 48 56 Output voltage [Vdc] Fig. 12: Output current versus output voltage 48 V 10

Curves (continued) Hold-up time [msec] IMA-x400-12 Hold-up time [msec] IMA-x400-24 20 17 20 17 9.6 12 14.4 Output voltage [Vdc] Fig. 13: Hold-up time versus output voltage 12 V 19.2 24 28.8 Output voltage [Vdc] Fig. 14: Hold-up time versus output voltage 24 V Hold-up time [msec] 20 17 IMA-x400-48 38.4 48 56 Output voltage [Vdc] Fig. 15: Hold-up time versus output voltage 48 V IMA-x400-12 Efficiency [%] 96 94 92 90 88 86 84 82 80 20 40 60 80 100 Output power [%] 230 Vac 115 Vac Fig. 16: Typical efficiency curves 12 V IMA-x400-24 Efficiency [%] 96 94 92 90 88 86 84 82 80 20 40 60 80 100 Output power [%] 230 Vac 115 Vac Fig. 17: Typical efficiency curves 24 V IMA-x400-48 Efficiency [%] 96 94 92 90 88 86 84 82 80 20 40 60 80 100 Output power [%] 230 Vac 115 Vac Fig. 18: Typical efficiency curves 48 V 11

Pin assignment (J3) 14 12 10 8 6 4 2 13 11 9 7 5 3 1 Pin Assignment Pin Assignment 14 -V_SENSE 13 +V_SENSE 12 Address 11 Current_Share_V 10 Remote ON/OFF 9 PWR_GOOD 8 +5VSB 7 5VSB_RTN 6 SDA 5 SCL 4 5VSB_RTN 3 5VSB_RTN 2 +5VSB 1 +5VSB Fig. 19: Pin assignment J3 terminal block Mating connector type: Molex, Part number 51110-145x Circuit diagrams Power Supply Unit +5VSB 1 kω Power Supply Unit 3.3V_µC REMOTE ON/OFF 5VSB_RTN J3 1 kω PWR_GOOD 5VSB_RTN J3 Fig. 20: Circuit diagram J3 Pin 10 (REMOTE ON/OFF) Fig. 21: Circuit diagram J3 Pin 9 (PWR_GOOD) AC Input 20 ms Main DC Output 10 ms 10 ms PWR_GOOD Fig. 22: Power Good function timing For DC output voltage Nominal output voltage; will reduce at DC output voltages > Nominal output voltage. 12

This page is intentially left blank. 13

Sales Contact Europe Delta Electronics (Netherlands) BV Zandsteen 15 2132 MZ Hoofddorp The Netherlands deu.sales@deltaww.com www.deltaenergysystems.com USA Delta Products Corporation 46101 Fremont Blvd. Fremont, CA 94538 USA na.sales@deltaww.com www.deltaenergysystems.com Other regions Delta Energy Systems (Germany) GmbH Tscheulinstrasse 21 79331 Teningen Germany im.sales@deltaww.com www.deltaenergysystems.com All information and specifications are subject to change without prior notice