Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Similar documents
NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

Gamma Scientific Display Measurement Systems

Solid State Luminance Standards

Model S471-LED Optometer

LED Lighting Flux and Color Measurement System (LFC)

We bring quality to light. MAS 40 Mini-Array Spectrometer

Spectroradiometer specbos 1201

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

LED Tester BTS256-LED

JETI Specbos Instruments

Broadbandradiometer specbos 1211

specification display & lighting hera spectrometer

Chameleon Spectroradiometer

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Considerations When Transitioning from Lamp-based to LED-based Radiant Flux Sources

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

USER OPERATION MANUAL. SpectralLED TUNABLE LIGHT SOURCE MODEL: RS-7

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

AvaLight-DHc Full-range Compact Light Source

illumia Plus Temperature Controlled Light Measurement Systems

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

We bring quality to light. CAS 120 CCD Array Spectrometer

Miniaturized Spectroradiometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

ULS24 Frequently Asked Questions

New automated laser facility for detector calibrations

Camera Calibration Certificate No: DMC III 27542

LEADING THE WAY in Light Measurement Systems

Photometry for Traffic Engineers...

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LI-192 Underwater Quantum Sensor

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

operating manual iliad for Windows & Mac OS X software application rc81

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

Photometry for Traffic Engineers...

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

LI-193 Spherical Quantum Sensor

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Miniature Spectrometer Technical specifications

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Company synopsis. MSU series

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

2014 PRODUCT SELECTION GUIDE

MAKING LIGHT WORK OF LIGHT MEASUREMENT. Guide to Photometer & Radiometer. System Configuration

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

specification display applications hera spectrometer

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Improved Radiometry for LED Arrays

Improving the Collection Efficiency of Raman Scattering

Calibration of a High Dynamic Range, Low Light Level Visible Source

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Advances in Measuring UV LED Arrays

PR-655 PR-670 PR-680 and PR-680L SpectraScan

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

Development of 2 Total Spectral Radiant Flux Standards at NIST

Pulsed Laser Power Measurement Systems

SPECTRAL SCANNER. Recycling

Compact High Intensity Light Source

Les Industries Spectralux Inc. Spectralux Industries Inc.

specification light bulb cronus bhaskar spectrometer & colorimeter for light bulb measurements

71332 LED Dusk To Dawn (Area Light)

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

The Right Tool for a Spectrum of Applications

The Standard for over 40 Years

Cat# LED Wall-PACK

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

The Importance of Wavelengths on Optical Designs

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

LED Tester BTS256-LED

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Oriel MS260i TM 1/4 m Imaging Spectrograph

Measuring the Performance of UV LED Light Sources

Table 8 Overview light sources

Integrated Diode Laser System DioPower

OP735. Benchtop Optical Power Meter Instruction Manual

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

INSTRUMENTATION SELECTION GUIDE

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Transcription:

SpectralLED RS-7-1-VIS Benchtop Uniform Light Source For the ultimate in resolution and accuracy, the SpectralLED Tunable VIS source incorporates 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rocksolid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration KEY FEATURES Constant Current Drivers & Built-in Optical Feedback Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up, Repeatable Performance ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy APPLICATION AREAS Camera and Image Sensor Calibration Photodiode Detector Responsivity Characterization Spectrum / Illuminant Simulation Diagnostic MedicalImaging Technical and Industrial Photography contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-1-VIS Uniform Light Source RS-7-1 OPTICAL SPECIFICATIONS Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth Source Geometry Spatial Uniformity 32 discrete LED channels, 3 broadband LED channels Visible resolution ~ 15nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configs available) Typical VIS of 20nm and NIR of 50nm FWHM 75mm dia, Lambertian radiant source (see RS-7-2 models for exit ports up to 600 mm dia) 97% over 8 field of view Radiance Range Typical maximum of 15,000 µw / cm 2 / sr Typical minimum of 15 µw / cm 2 / sr Luminance Range Typical maximum of 30,000 cd / m 2 Typical minimum of 30 cd / m 2 CCT Range 1,900K to 40,000K Sensitivity Preset Spectra CIE illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM patches Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range ACCURACY SPECIFICATIONS Illumination Stability 99.99% after 50 ms for radiance or after 2,000 ms for spectrum Illumination Accuracy ± 1% Absolute, NIST traceable Spectral Accuracy ± 1 nm centroid wavelength Color Accuracy CIE 1931 x,y ± 0.003 Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (typical, channel dependent) Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs Electrical Resolution ELECTRICAL SPECIFICATIONS 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS LM-79 / LM- 80 LED testing. Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage & Power Dimensions (H x W x L) RS-7 Wavemon RS-7-IRIS Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum 405mm (16 in) x 460mm (18.1in) x (305mm (12in). Weight 17.5 kg (38.6 lbs) OPTIONAL UPGRADES Multi-channel photodiode system w / amplitude feedback & real-time ƛ measurements Integrated IRIS w/ stepper motor control & additional API commands for easy adjustment Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.185 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-1-SWIR Benchtop Uniform LightSource For the ultimate in resolution and accuracy, the SpectralLED Tunable SWIR source incorporates 9 shortwave infrared wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For SWIR Camera & Image Sensor Calibration KEY FEATURES Gold Coated Integrating Sphere Constant Current Drivers & Built-in Optical Feedback Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up & Repeatable Performance ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy APPLICATION AREAS Camera and Image SensorCalibration Photodiode Detector Responsivity Characterization Spectrum / Illuminant Simulation Diagnostic Medical Imaging Technical and Industrial Photography contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

RS-7-3-SWIR Fiber Optic Output Flexible illumination for applications where space is limited Can be configured with multiple outputs enabling several devices to be simultaneously illuminated at different locations Integrated collimating optics at fiber distal end Custom fiber diameters and lengths available RS-7-4-SWIR Wafer Probe Directly replaces lamp-based sensor testers already deployed in the field Easily programmed to deliver virtually any desired spectral power distribution of SWIR light All solid-state design maintains calibration & eliminates downtime associated with lamp replacement RS-7-5-SWIR Baffle Output 150mm output with irradiancecalibration Includes an integrated baffle tube with 150mm clear aperture User adjustable f-numbers including f/1, f/2, f/3 and f/4 Ideal for testing of bare sensors RS-7-6-SWIR Wide Field of View For applications requiring Wide Field of View (up to 180 degrees) Optical design delivers equal radiance over the entire Field of View Ideal for flat fielding fish eye or ultra-wide field of view lens designs 75mm output port with >98%uniformity contact@gamma-sci.com +1.858.279.8034

SpectralLED Calibration & Test of Night Vision Equipment MEASUREMENT PARAMETERS Quantum Efficiency Spatial Non-uniformity Pixel Defects Remote Sensing Image Calibration Crosstalk Vignetting Correction Responsivity Signal-to-noise Linearity ISO Speed Remote Sensing Equipment Manufacturing Dynamic Range Sensitivity Hyperspectral Imaging Industrial monitoring, Security & Defense, Semiconductor Equipment www.gamma-sci.com

SpectralLED RS-7-1-SWIR Benchtop Uniform Light Source OPTICAL SPECIFICATIONS Spectral Range 900 nm to 1,700 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth Custom Preset Spectra 9 discrete LED channels SWIR resolution ~ 50 nm (typical channel spacing) 910nm, 940nm, 980nm, 1050nm, 1200nm, 1300nm, 1450nm, 1550nm, 1650nm (custom configurations available) Typical of 50-100nm FWHM (channel dependent) Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Illumination Stability Illumination Accuracy Spectral Accuracy Linearity Temperature Stability 99.99% after 50 ms for radiance or after 2,000 ms for spectrum ± 3% Absolute, NIST traceable ± 2.5 nm centroid wavelength < 0.1 % RMS of full scale Within ± 1 C via active TEC ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Varies according to specific part number configuration, please contact factory for details PART NUMBER CONFIGURATIONS RS-7-1-SWIR RS-7-3-SWIR RS-7-4-SWIR RS-7-5-SWIR RS-7-6-SWIR 75mm output port, 200mm gold coated integrating sphere Fiber Optic Output light delivery via one or more fiber bundles Wafer Probe Illuminator for wafer level testing of CCD and CMOS sensors Baffle Tube Output with 150 mm clear aperture with user adjustable f-number Wide Field of View with Gold coating providing high uniformity at up to 180 degree viewing angle Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-2-VIS Tunable Light Source - Large Output Port When you require a large area, highly uniform light source for camera and image sensor calibration, the SpectralLED Large Output Port delivers brightness, radiometric stability and wavelength accuracy that is unmatched in the industry. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistentresults. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time Sphere Diameter Max Exit Port Diameter Number of SpectralLED 0.5 m 150 mm 1 1.0 m 300 mm 1 to 4 1.5 m 600 mm 2 to 8 All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-2-VIS Large Output Port RS-7-2-VIS SPECIFICATIONS Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Source Geometry Spatial Uniformity 99% Optical Geometry Radiance Range Luminance Range 150mm, 300mm or 600mm diameter uniform output, Lambertian radiant source (Other output port sizes available on request) Integrating sphere with 500mm, 1,000mm or 1,500mm diameter (Other sphere sizes available on request) Dependent upon integrating sphere size and number of light engines attached. Please consult with factory for configuration parameters and output specifications. OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 585nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM Linearity ISO Speed Saturation Exposure Dynamic range Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± 0.003 Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Light Engine Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Dependent on integrating sphere chosen please contact factory for details UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice. Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-3-VIS Tunable Light Source - Fiber Optic Output The SpectralLED Fiber Optic Output configuration provides flexible illumination for applications where space is limited. Systems can be configured with multiple outputs enabling several devices to be simultaneously illuminated at different working locations. Collimating optics are included at the fiber distal end, and custom fiber diameters and lengths areavailable. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Fiber Outputs Fiber Length Fiber Diameter 4 1.5 m 6.35 mm [Most systems are custom configured please consult factory] Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-3-VIS Fiber Optic Output RS-7-3-VIS SPECIFICATIONS Measurement Applications Optical Geometry Spatial Uniformity Radiance Range Luminance Range Typically 0.55 NA (fiber dependent) Typically > 70% (fiber dependent) Up to 500 µw/cm 2 (at 5cm, fiber and spectrum dependent) Up to 1,000 lux (fiber and spectrum dependent) White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges are available on request, including SWIR options) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy 32 discrete LED channels + 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± 0.003 Linearity Temperature Stability < 1 % RMS of full scale Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-4-VIS Tunable Light Source Wafer Probe Illuminator The SpectralLED Wafer Probe Illuminator is an all solidstate, drop-in replacement for field-deployed wafer-level CCD and CMOS sensor testers. The system is fully turnkey, and can readily be adapted to test head manipulators and handler instrumentation. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Wavelength Options From the UVA to the NearInfrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy System Compatibility ü Agilent ü Teradyne ü National Instruments ü Yokogawa ü Advantest ü Cascade Microtech contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-4-VIS Wafer Probe Illuminator Measurement Applications OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) White Balance Quantum Efficiency Spatial Non-uniformity Spectral Peaks Spectral Bandwidth 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is ISO/IEC 17025 CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Illumination Stability 99.99% after 50 ms for radiance or after 2,000 ms for color Illumination Accuracy ± 1% Absolute, NIST traceable Spectral Accuracy ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± 0.003 Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions RS-7 Wavemon Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Please contact factory for details UPGRADES Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-5-VIS Tunable Light Source Baffle Tube Output The SpectralLED Baffle Tube Output features a 150 mm clear aperture with user interchangeable baffle tubes for adjustable f- numbers of f/1, f/2, f/3 and f/4. The unit is ideally suited for testing of bare sensors in an R&D or productionenvironment. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Number of Baffle Tubes f-number 1 (attached) f/1 2 f/2 3 f/3 4 f/4 Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS7-5-VIS Baffle Tube Output Measurement Applications RS-7-5-VIS SPECIFICATIONS Source Geometry 150mm diameter uniform output with Baffle Tube irradiance source Spatial Uniformity 95% Optical Geometry Specialized design for user adjustable f-number White Balance Quantum Efficiency Spatial Non-uniformity Radiance Range Depends on f-number and spectrum. Contact factory for details. Luminance Range OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Pixel Defects Crosstalk Vignetting Correction Sensitivity Spectral Output Spectral Peaks 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Responsivity Signal to noise Linearity ISO Speed Spectral Bandwidth Typical: Visible 20nm FWHM, NIR 50nm FWHM CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Saturation Exposure Dynamic range Illumination Stability Illumination Accuracy Spectral Accuracy 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± 0.003 Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions (1) Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice (1) Does not include Baffle Tube Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-6-VIS Tunable Light Source Wide Field of View The SpectralLED Wide Field of View (FOV) is ideally suited for applications requiring a field of view up to 180. The unique optical design delivers equal radiance over the entire field, which is critical for users desiring flat fielding fisheye or ultra-wide FOV lens designs. With better than 97% uniformity across the 75mm output, the performance is unmatched in the industry. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X-RITE Color Patch Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time] ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-6-VIS Wide Field of View Measurement Applications Source Geometry Spatial Uniformity Optical Geometry RS-7-6-VIS SPECIFICATIONS 75mm diameter uniform output with 180 field of view. Lambertian radiant source. 95% over 180 (2π steradians) Built-in integrating cavity. Specialized optical design for user adjustable spot parameters. White Balance Quantum Efficiency Spatial Non-uniformity Radiance Range Typical maximum of 2,500µW/cm 2 /sr Typical minimum of 2.5µW/cm 2 /sr (spectrum dependent) Luminance Range Typical maximum of 5,000cd/m 2 Typical minimum of 5 cd/cm 2 (spectrum dependent) OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Pixel Defects Crosstalk Vignetting Correction Sensitivity Spectral Output Spectral Peaks 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Responsivity Signal to noise Linearity ISO Speed Spectral Bandwidth Typical: Visible 20nm FWHM, NIR 50nm FWHM CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Saturation Exposure Dynamic range Illumination Stability Illumination Accuracy Spectral Accuracy 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± 0.003 Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-7-VIS Tunable Light Source Light Booth The SpectralLED Light Booth quickly simulates virtually infinite lighting conditions enabling visual color assessment for photography, product display or lighting design applications. Both real and theoretical lighting conditions can be produced, enabling CRI experimentation, analysis and optimization. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For CRI Experimantation, Analysis & Optimization All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X-RITE Color Patch Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

SpectralLED RS-7-7-VIS Light Booth Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is RS-7-7-VIS OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± 0.003 Linearity Temperature Stability < 0.1 % RMS of full scale Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) and performs LM-79 / LM-80 LED testing. Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Software Interface Connectors Interface Protocol Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer Supported Operating Systems Input Voltage and Power Interior Dimensions USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum 45 x 45 x 45 cm (preliminary) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 Phone: +1.858.279.8034 www.gamma-sci.com

RS-7 Wavemon TM Option The Wavemon TM Wavelength Monitor System upgrade is a multi-channel photodiode system that provides amplitude feedback and real-time wavelength measurements. It consists of three photodiodes each with an independent transimpedance amplifier circuit, with 5 gain ranges for each channel. Proprietary optical filtering techniques allow for wavelength accuracy of +/- 0.25nm and repeatability of +/-0.05nm using only 3 photodiode channels. The Wavelength Monitor PCBA, photodiodes, and optical filter assembly are temperature stabilized using a Peltier cooler and thermistor in a PID feedback loop. Real-time Amplitude & Wavelength Monitoring Unmatched Accuracy and Repeatability Sub-nanometer Wavelength Measurement Accuracy ± 1% Irradiance Measurement Accuracy ASCII Command Set for Simple Device Control 5 Gain Stages per Channel for Increased Dynamic Range Built-in Thermal Regulation for Long-term Stability On-board Unit-specific Calibration Data ISO/IEC 17025 Accredited by NVLAP (NVLAP lab code 200823-0) for Calibration Accuracy The SpectralLED family of tunable light sources incorporate 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. contact@gamma-sci.com +1.858.279.8034 www.gamma-sci.com

RS-7 Wavemon TM Option ACCURACY SPECIFICATIONS Spectral Range 365 nm to 1,100 nm (Short Wave Infrared options possible) Wavelength Absolute Accuracy Wavelength Repeatability ± 0.25 nm ± 0.01 nm Irradiance Absolute Accuracy ± 1% Irradiance Repeatability / Stability 0.1% ELECTRICAL SPECIFICATIONS Photodetector Channels Transimpedance Amplifier One bare Silicon, two optically filtered Silicon Channel independent, shielded and temperature stabilized circuit Gain Ranges per TIA Channel 5 GENERAL SPECIFICATIONS Com Port Interface Protocol Interface Connectors & Input Requirements Dimensions FTDI USB UART (virtual) Simple ASCII commands Connects directly to the RS7 light engine via included cables Length 71.5mm (2.82 in), Width 44.5mm (1.75 in), Height x 44.5mm (1.75 in) SpectraLED Family of Tunable Light Sources RS7-1 Benchtop RS7-2 Large Output Port RS7-3 Fiber Optic Output RS7-4 Wafer Probe 75mm output port with integral integrating sphere Exit ports ranging from 150mm to 600 mm One or more fiber outputs with distal end collimation Directly replaces lamp-based systems RS7-5 Baffle Output 150mm output with user adjustable f/number of f/1, f/2, f/3 or f/4 RS7-6 Wide Field of View RS7-7 Light Booth 75mm output port with up to 180 field of view CRI experimentation, analysis & optimization Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev 1.18 9925 Carroll Canyon Rd San Diego, CA 92131 +1.858.279.8034 www.gamma-sci.com