Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Similar documents
Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Introduction. Part 1. Introduction...2

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies N4985A System Amplifiers

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Solid State Switches. Application Note

Keysight Technologies

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies E4980A Precision LCR Meter

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies USB Preamplifiers

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies How to Perform QSCV (Quasi-Static Capacitance Voltage) Measurement

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight N9310A RF Signal Generator

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies U1210 Series Handheld Clamp Meters

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies Photodiode Test Using the Keysight B2980A Series

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies HMMC-3002 DC-16 GHz GaAs HBT MMIC Divide-by-2 Prescaler

Keysight Technologies HMMC-3008 DC-16 GHz GaAs HBT MMIC Divide-by-8 Prescaler

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies Characterizing Random Noise in CMOS Image Sensors

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies U9400A/C Solid State FET Transfer Switches

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Introduction. Part 1. Introduction...2

Keysight Technologies Measuring Dielectric Properties Using Keysight s Materials Measurement Solutions

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

Transcription:

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level 4080 Series Parametric Test Systems Application Note

Introduction The continuing trend of decreasing device geometries of the next generation of ULSI devices is making precise characterization evaluation of semiconductor devices more and more critical. Measurement of capacitance is used to determine oxide thickness, one of the key parameters of semiconductor devices. This oxide thickness is becoming thinner and thinner from generation to generation. Therefore, accurate capacitance measurement is very important in semiconductor process integration and process monitoring. The Keysight 4080 series of parametric test systems perform accurate capacitance measurements, reliably and quickly. In order for 4080 series test systems to perform such precise measurements, appropriate fixturing and measurement techniques are required. This application note describes the procedures required to precisely evaluate the capacitance of a Device Under Test (DUT) when using a 4080 series test system with an automatic wafer prober.

3 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Factors Affecting the Measurement of Capacitance and Problem-Solving Techniques Stray Capacitance and Residual Inductance Cable and electrical leads in the measurement system behave like distributed electrical lines when a high-frequency AC signal passes through them. Capacitance measurement in 4080 series test systems is done by applying a relatively high frequency measurement signal, selectable from 1 khz to 1 MHz, to the DUT and then measuring the resulting current using an auto-balancing bridge circuit. When measuring capacitance using a high frequency signal such as 1 MHz, stray capacitance and residual inductance inherent to cables, electrical leads, and other portions of the measurement circuit can cause AC signal loss. This leads to degradation of the capacitance measurement accuracy. Figure 1 shows an equivalent circuit of the measurement path. The Capacitance Measurement Unit (CMU) in 4080 series test systems regards the entire measurement path as the device to measure. Compensation for the cables and switching matrix is automatically performed by the Test Instruction Set (TIS) command so that the actual capacitance of the DUT is obtained. For example, the compensation for 4 m cables is performed by a built-in function of the CMU (Keysight E4980A). For a switching matrix, the actual capacitance of the DUT is calculated by multiplying the inverse matrix of the F matrix by the entire measurement value. The circuit constants used in the F matrix are measured when the system is installed and recorded for each 4080 series test system. Therefore, precise capacitance measurement results are obtained by using TIS commands. Figure 1. (A) Simplified diagram of Keysight 4080 series test system (B) Equivalent circuit of measurement path for capacitance measurement.

4 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Offset Capacitance The offset capacitance caused by a probe card or probe needles cannot automatically be compensated for by the TIS commands. Offset capacitance depends on the probe card used. If adjacent pins and the recommended probe card are used, the offset capacitance value would be smaller than 500 ff. To obtain the actual capacitance of the DUT, measure the offset capacitance and then measure the capacitance of the DUT. Subtract the offset capacitance from the measured capacitance (see Figure 2). Series Resistance of the DUT In most cases, semiconductor capacitors can be viewed as a parallel circuit of capacitance and conductance. Keysight 4080 series test systems assume the DUT can be modeled as a parallel connection of capacitance and conductance. However, in other cases, the equivalent circuit of the device can be drawn as a series connection of resistance and capacitance. For instance, if poly-si is used between the oxide and Al lead and the resistance of the poly-si is relatively large compared to the impedance of the capacitance, the DUT is regarded as a series connection of capacitance and resistance. In such cases, measurement results need to be adjusted to eliminate the error caused by the incorrect assumption. The Conv_mode command is provided to allow you to calculate the correct capacitance value if the equivalent circuit of the DUT can be modeled as a series connection of resistance and capacitance. Figure 2. Procedure to cancel offset capacitance. Signal Loss through the Large Chuck of the Prober The capacitance between the chuck on the probe station and ground is becoming large. There are two reasons for this. 1) The size of the chuck on the probe station is increasing as wafer size increases. Capacitance is proportional to chuck size. 2) The demand for a hot chuck is increasing for process integration or process monitoring. Having the heater of the hot chuck close to the top of the chuck reduces the distance between the chuck top and ground, which results in the increase of capacitance to ground. In many situations the large capacitance between the chuck and ground affects the accurate capacitance measurement of the DUT. Figure 3. (A) Equivalent circuit of normal device, (B) Equivalent circuit of device which has large series resistance, (C) Example device structure which has large series resistance. When the chuck on a probe station is used as a measurement terminal for the capacitance measurement, the measurement current flows to ground through the chuck. Unexpected leakage of the measurement signal affects measurement accuracy (see Figure 4). The same type of signal loss occurs when the isolation is insufficient between the expected measurement signal path and the chuck on the probe station. Figure 4. Unexpected leakage of measurement signal.

5 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Figure 5 shows two other typical device structures. If the electrode for the wafer substrate is placed on the top side of a wafer, an error can occur if the device structure is as shown in Figure 5(A) where the wafer substrate and probe chuck are not electrically isolated. The device structure shown in Figure 5(B) has better isolation between the measurement signal path and the prober chuck because the PN junction formed by the N-well in the P- substrate acts as a barrier for the leakage current. The isolation level of the PN junction determines whether or not there is a signal loss to ground. Figure 6 shows the frequency dependency of capacitance measured on the device shown in Figure 5(A). The results show that measurement error increases as the measurement frequency is increased beyond 200 khz. The amount of error increases up to 4% at a 1 MHz measurement frequency. Figure 5. Device structure. Figure 6. Frequency dependency of capacitance taken on the device structure shown in Figure 5 (A). When a high frequency measurement signal is used, signal loss is proportional to the residual inductance and stray capacitance along the measurement signal path. Therefore, total measurement error is proportional to the square of the measurement frequency. In other words, if the measurement frequency is reduced by a factor of 10, then the measurement error is reduced by a factor of 100. A 4% error observed at a 1 MHz measurement frequency is reduced to a negligible level if the measurement frequency is reduced to 100 khz. The accuracy of a capacitance measurement is proportional to the measurement frequency. The CMU measures the current induced by the capacitance of the DUT. For an AC signal this current is proportional to the measurement frequency (I = 2 πfcv). Figure 7 shows the relationship between the standard deviation of the capacitance measured on the actual device and measurement frequency. Figure 7. Frequency dependency of standard deviation of measured capacitance (Integration time : LONG).

6 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note The results show that measurement accuracy improves as the measurement frequency is increased. It decreases when measurement frequency is over 200 khz. This degradation at frequencies over 200 khz is due to the effects of inductance along the signal path. Therefore, a measurement frequency between 10 khz and 100 khz is recommended when measuring capacitance. External Signal The measurement results are affected if the measurement environment includes a large amount of electrical noise. If the capacitance between the prober chuck and ground is large, then the chuck will likely receive high frequency noise. This is because the isolation between the prober chuck and ground is not as good in the high frequency range. The major sources of noise in the automatic prober are the power supply circuit and the hot chuck. If sufficient shielding is provided in the prober station then the measurement is less affected by the ambient noise. Using a large AC signal to increase the signal-to-noise ratio will reduce the error caused by external noise. Figure 8 shows the signal level dependency of standard deviation of capacitance measurements. Integration time is also varied from short to long. Repeatability is improved as signal level is increased. The standard deviation can be reduced to less than 1 ff by using a 100 mv signal level and a long integration time. When evaluating oxide thickness, using a large signal level will help reduce the measurement error. Oxide thickness is calculated from the capacitance value when the DUT is in an accumulation mode that doesn t show voltage dependency. When evaluating oxide thickness by measuring capacitance in accumulation mode, it is important to put the device well into accumulation mode. The applied bias voltage should be determined by finding the C-V characteristics where the capacitance fluctuation caused by a change in voltage is small. Figure 8 Signal level dependency of standard deviation of capacitance measurement.

7 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Quasi-unbalanced State Caused by Improper Connection When the capacitance between the chuck and ground is large, the connections between the measurement ports and the device terminals are important when making a precise capacitance measurement. Figure 9 shows example measurement results taken with two different connections of the measurement ports and the device terminals. One result was measured by connecting the CMH port to the gate terminal of the device and connecting the CML port to the substrate terminal of the device. The other result was measured by connecting the CML port to the gate terminal and connecting the CMH port to the substrate terminal. When connecting the CMH to the gate terminal a deviation of up to 7% can be seen. The opposite connection shows a stable result. This kind of error does not always occur. It depends on the DUT and the measurement environment. Figure 9. Measurement results with two different connections. The CMU in the Keysight 4080 series test system uses an auto-balancing bridge method to measure the impedance of the DUT as shown in Figure 10. The detector D detects the potential at point A and controls the magnitude and phase of the Osc2 output so the detected potential is zero. If the measurement signal is not stable, then it becomes difficult for the auto-balancing bridge to force stabilization of the potential at point A to zero. When the CML port is connected to the substrate terminal of a device and the substrate has insufficient isolation from the chuck on the prober, the auto-balancing bridge is likely to become unbalanced due to the large capacitance and external noise. Figure 10. Auto-balancing bridge in CMU.

8 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Figure 11 shows C-V measurement results with both connections. Clearly, connecting the CML port to the gate and the CMH port to the substrate provides better measurement results. The recommended connection is shown in Figure 12. In this case, the polarity of the bias voltage must be taken into account when writing a measurement algorithm. Figure 11. Measurement results with two different connections. (A) Connecting CMH port to the gate terminal and CML port to the substrate. (B) Connecting the CML port to the gate and the CMH to the substrate. Figure 12. Recommended connection. Figure 13. Unexpected current flow through other devices. Signal Loss Through Other Devices When the capacitance between probe pins is high and the capacitance of the adjacent device is not negligible, then an unexpected current path is formed as shown in Figure 13. In this case, additional current flows into the CML port through the stray capacitance between probe pins and the adjacent device.

9 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note The measured capacitance value is larger than the actual capacitance value since additional current is measured by the current meter in the CML port. The total amount of error is determined by the stray capacitance between the measurement pins and the capacitance value of the adjacent device (see Figure 13 ). With Keysight 4080 series test systems, the error caused by this mechanism will be limited to less than a couple of hundred ff if the recommended probe card is used. The problem is likely to be seen when correlating the results between the Keysight 4080 series test systems and other parametric test systems. Due to large stray capacitance between the probing needles, other parametric test systems can exhibit an error as large as the amount of stray capacitance between the measurement pins. There are three solutions for solving this problem. 1) Use a probe card interface and a probe card which have a small stray capacitance between the measurement pins. Reducing capacitance between pins is achieved by having a shield around the measurement pin. However, the cost of changing the probe card interface and probe card may be too great. 2) Change the test structure so adjacent devices do not have large capacitances. Stray capacitance between measurement pins is inversely proportion to the distance between the pins. Swapping the pad locations for the pins by modifying the design of the test structure will reduce this error significantly. 3) Use the GCMU to sink extraneous current flow through the stray capacitance between pins. The third suggestion is the easiest to implement. The GCMU is the shield of the CMU as shown in Figure 14. Extraneous current, going through stray capacitance between pins, will flow into the GCMU. This is because the impedance of the GCMU is lower than the impedance of the adjacent device. Additional current will not be measured by the current meter in the CML port. For example, this method will not work when the impedance between the measuring pad and the adjacent pad is low. However, it should be the first method tried when the capacitance measured by the other test system is larger than that measured by the 4080 series test system. Figure 14. Reducing error by connecting the GCMU to adjacent terminals.

10 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Conclusion Keysight 4080 series test systems can perform accurate and repeatable capacitance measurements. See Figure 15. The following conditions are necessary for the system to reach its full potential. 1) The offset capacitance must be subtracted in the user s measurement program. 2) When the series resistance in the DUT is large, compensation by using the Conv_ mode command is required. 3) A measurement frequency between 10 khz and 100 khz should be used in order to avoid signal loss caused by the large capacitance of the chuck. 4) A higher signal level is recommended to reduce the effect of external noise. 5) To reduce noise and to reduce unbalance of the CMU it is important to connect the CMH port to the bulk or substrate and to connect the CML port to the gate. 6) An appropriate probe card, which has small stray capacitance between pins, is required. Figure 15. Example measurement results.

11 Keysight Accurate Capacitance Characterization at the Wafer Level - Application Note Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/4080 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, December 1, 2017 5990-7119EN www.keysight.com