IQAN-TOC8 Instruction book

Similar documents
IQAN-MC3 Instruction book Publ no HY IB/UK Edition

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Analog amplifier RA. RE Edition: Replaces:

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

DM-45 Digital Multimeter

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

with Electronic Assistant

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

TECHNICAL PRODUCT DATASHEET

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

Sealed Interface Control: EC20300

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Functional data Factory settings Variable Settings

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

BODAS Controller RC Series 22

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

BC145 SIGNAL ISOLATOR BOARD

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

HAWK5000 Operators Manual

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

DVC700 Series Programmable System Controller

DVC700 Series Programmable System Controller

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

User s Manual for Integrator Short Pulse ISP16 10JUN2016

Thermo Electric Cooling Temperature Controller TEC Controller / Peltier Driver ±16 A / ±22 V or 31 V

Actuator LA12 PRODUCT DATA SHEET

58V signal frequency input analog input ( ma, PT1000. sensor) Programming System

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Thermo Electric Cooling Temperature Controller TEC Controller / Peltier Driver ±16 A / ±19 V

Pressure Transmitter SIL

OPERATOR S INSTRUCTION MANUAL

ACTUATOR LA36 PRODUCT DATA SHEET

Potentiometer Control EC20200

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ordering Part Numbers: SAE J1939 version Controller: AX022400

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

maxon document number:

Smart Power Relay E I...

IF30. User's manual. Description. Table of contents IF30

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

CM2904 Instruction Book. Publ no HY IB/UK

PHOENIX CONTACT - 03/2007

Overview of types. Technical data

Electronic regulator for PWM controlled proportional solenoid valves FABER -

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

with Electronic Assistant

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

HB-25 Motor Controller (#29144)

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

RMO500 M I C R O O H M M E T E R

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

POWER SYSTEM MODE STATUS

HO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement

Current Transducer CTSR 1-P = 1A

Applications: Power generation, Cogeneration, Stationary power Large engines

Hagie STS/DTS (2018 & Newer)

Pen-type DIGITAL MULTITESTER

Continental Hydraulics Installation Manual CEM-RA-A

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

02/11/2015

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

This data sheet is only valid in association with the IL SYS INST UM E user manual.

RT-5005/5006/5007/5008

ISOMETER IRDH575. Approvals

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

NLG513 SOFTWARE. Translation of the original German operating instructions

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MEGA REMOTE RADIO REMOTE CONTROL SYSTEM

DENISON HYDRAULICS Proportional Pressure Control Valves

INSTALLATION AND OPERATION MANUAL

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Coils & Electronic Controls

ELECTRONIC CONTROL DEVICES

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

PHOENIX CONTACT - 09/2009

User s Manual Current Probe. IM E 2nd Edition IM E

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Transcription:

Instruction book Publ no HY33-8304-IB/UK Edition 2011-08-10

Contents 1 Introduction......................................................1 Warnings............................................................ 1 Overview of relevant documentation................................. 2 2 Precautions.......................................................3 Read This............................................................ 3 3 Product description............................................... 5.......................................................... 5 4 Safety............................................................6 Internal diagnostics.................................................. 6 CAN-bus interruption................................................ 6 Current check....................................................... 6 Emergency stop..................................................... 6 5 Mounting.........................................................7 Mounting the unit................................................... 7 6 Installation.......................................................8 Connector C1........................................................ 8 Supply voltage...................................................... 9 Communication.................................................... 10 Reference voltage, VREF............................................ 11 Voltage inputs...................................................... 12 Frequency inputs................................................... 15 Current outputs.................................................... 16 Digital outputs..................................................... 17 PWM outputs....................................................... 19 7 Start-up.........................................................20 Start-up procedures................................................ 20 8 System Diagnostics..............................................21 Appendix A......................................................22 Technical Overview..................................... 22 Appendix B......................................................25 Error codes, messages and actions.................................. 25 Appendix C......................................................28 Dimensioning of the module............................ 28 Instruction book, IQAN-XP2 ii

Warnings 1 Introduction 1 Introduction These instructions are to be used as a reference tool for the vehicle manufacturer s design, production, and service personnel. The user of these instructions should have basic knowledge in the handling of electronic equipment. Warnings Sections marked with a symbol in the left margin, must be read and understood by everyone using the system, carrying out service work, or making changes to hardware and software. The different symbols used in this manual are defined below. WARNING Sections labeled WARNING with a caution symbol in the left margin, indicate that a hazardous situation exists. We use warnings, marked with the warning symbol, in two ways. As a strong recommendation about work practices when using the product in the machine (e.g. routines when updating an application). This use is common to the term 'hazardous situation', that a person is exposed to a hazard. As a way of pointing out important information for the machine designer that in some way relates to safety. This includes the design of the physical machine, and also the application program being developed for the control system. Not all document sections that contain information about safety are marked with a warning symbol (there would be warnings everywhere). Failure to comply with the recommendations can cause unintentional, and unexpected behavior of the control system. This can potentially cause death, serious injury or property damage. NOTICE Sections labeled NOTICE with a notice symbol in the left margin, indicate there is important information about the product. Ignoring this could result in less than optimal performance, or damage to the product. Contact the manufacturer if there is anything you are not sure about or if you have any questions regarding the product and its handling or maintenance. The term "manufacturer" refers to Parker Hannifin Corporation. 1

Overview of relevant documentation 1 Introduction Overview of relevant documentation The following publications are relevant for users of this product. The main documentation contains information that is not found elsewhere. The additional documentation contains product information in a compact format, for details on the information found in those documents, consult this manual. Main Documentation IQANdevelop User Manual Instruction Book HY33-8304-IB (this book) Compact Documentation Catalogue Datasheet HY33-8304 Installation Sheet HY33-8304-IS Electrical Schematic HY33-8304-ES The module documentation system. 2

Read This 2 Precautions 2 Precautions Work on the hydraulics control electronics may only be carried out by trained personnel who are well-acquainted with the control system, the machine and its safety regulations. WARNING Make sure that you have sufficient knowledge before designing, modifiying or servicing the control system. Read the relevant sections of this document before conducting any work on the control system. WARNING This product is not field repairable. NOTICE As much as possible of the welding work on the chassis should be done before the installation of the system. If welding has to be done afterwards, the electrical connections on the system must be disconnected from other equipment. The negative cable must always be disconnected from the battery before disconnecting the positive cable. The ground wire of the welder shall be positioned as close as possible to the place of the welding. The cables on the welding unit shall never be placed near the electrical wires of the control system. Read This Design of control system WARNING Risk of injury may be introduced by design of control system! This product is designed to control hydraulic outputs. The control application must be designed using basic safety principles so that unintentional movement is avoided. The machine must be equipped with an emergency stop that stops all movement. Please refer to see section Emergency stop, on page 9. Before you start Read this document, as a minimum sections 1-7 Read the IQANdevelop software user manual section on 'application safety'. 3

Read This 2 Precautions Start-up, maintenance, and diagnostics For all personnel carrying out installation, commissioning, maintenance or troubleshooting. WARNING Work on the hydraulics control electronics may only be carried out by trained personnel who are well-acquainted with the control system, the machine and its safety regulations. Before you start, Read see section Start-up, on page 20. Additional information for service Mounting and maintenance instruction book. Additional information for diagnosing the system Read see section System Diagnostics, on page 21, and see Appendix B, on page 25, in this document. Use the IQANdevelop software user manual as a reference. 4

3 Product description 3 Product description The is a stand alone controller designed for controlling hydraulic systems in vehicles and machinery, using 12/24 Vdc power supply. The controller. Input The has ten (10) inputs. These can be used as voltage inputs for connection of 0-5 Vdc signals or as digital inputs. VIN A thru VIN D can be configured as frequency inputs for measuring frequency. Voltage inputs and frequency inputs, share positions, see below. (10) Voltage inputs VINA, VINB,VINC,...,VINJ or (10) Digital inputs DINA, DINB, DINC,..., DINJ or (4) Frequency inputs FINA, FINB, FINC, FIND & (6) Voltage inputs VINE -VINJ Output The has 2 double current outputs for controlling proportional valves or devices. The unit has 6 digital outputs for on/off valves, or 3 double PWM outputs (Pulse Width Modulation) for controlling standard proportional and Pulsar TM type valves. Digital and PWM outputs share positions, see below. 2 double Current outputs 6 Digital outputs, or 3 double PWM outputs In order to increase the performance of the current outputs when controlling proportional valves, both the dither frequency and the dither amplitude can be adjusted. The digital output channels also have PWM, soft start and peak & hold features available. CAN related functions IQANsimulate software uses the CAN-bus (CAN = Control Area Network) to communicate with the controller when proving applications off of the machine (requires NI CAN card). The CAN-bus may be used by the TOC8 for SAE J1939 communication with engine electronics and for system control. 5

Internal diagnostics 4 Safety 4 Safety Internal diagnostics The module performs a number of self-checks that improve safety. Checks include monitoring of voltage supplies, checksums on memory and a watchdog that monitors software execution. The module is using a real time operating system which supervises software execution. If a critical error is detected, the module is stopped, with CAN-bus and outputs off. CAN-bus interruption The module monitors the CAN-bus (when used for SAE J1939) for interruptions in communication. An error will be presented with a related blink code on the status LEDs. Current check For the proportional outputs when used in current mode, a current check is performed. If an error is detected, this will be indicated on the module, and the output will shut off. The module can detect open-circuit, short-circuit to +BAT/-BAT or short-circuit to other proportional output and return pins. Emergency stop WARNING Risk of injury! The emergency stop must disconnect the power supply to the module; do not connect the emergency stop as a signal input only. The emergency stop must be installed so that the risk of reverse feed of the module is avoided, see section Emergency stop, on page 9. 6

Mounting the unit 5 Mounting 5 Mounting Mounting the unit The should be mounted according to the following instructions: Locate the unit eliminating the risk for the cabling to be folded, crushed or damaged in any way. Ensure the cabling cannot pull, twist or induce sideload on the connector. Locate the unit so that severe physical impact is avoided, e.g impact from falling objects or the unit being used as a step. Locate the unit so that air can circulate to eliminate excess heat. Ensure that no external heat, e.g. from the engine or heater, is transferred to the control. Locate the unit to protect it from high pressure washing or similar. Locate the unit so that the cable connector is facing down. Locate the unit so that the LEDs are visible. Non-approved placing. NOTICE The must not be placed in any marine-related or similar continuously damp environment without external protection. 7

Connector C1 6 Installation 6 Installation Connector C1 Connector kit Parker no. 5031063 Housing Amp no. 1-963226-1 Casing Amp no. 0-965643-1 Plane sealing, 42 p Amp no. 963225-1 42 28 14 29 15 1 *= The connector contains two types of terminals; MT (Micro Timer) and JPT (Junior Power Timer). Pin types* Amp no. 963711-2 (MT) Amp no. 929938-1 (JPT) Cables 0,75-1,0 mm² (MT) 1,5-2,5 mm² (JPT) Seals Amp no. 963530-1 (MT) Amp no. 828905-1 (JPT) Plugs (empty pos.) Amp no. 963531-1 (MT) Amp no. 828922 (JPT) IQAN toolkit Parker no. 5031061 Pos Signal name Pos Signal name Pos Signal name 1 not used 15 -BAT 29 -BAT2 2 +VREF-A 16 CAN-H 30 CAN-L 3 VIN-A/DIN-A/FIN-A 17 COUT-A 31 COUT-A 4 -VREF-A 18 CRET-A+ 32 CRET-A- 5 VIN-E/DIN-E 19 COUT-B 33 COUT-B 6 VIN-B/DIN-B/FIN-B 20 CRET-B+ 34 CRET-B- 7 VIN-F/DIN-F 21 DOUT-A/ PWMOUT-A 8 VIN-G/DIN-G 22 DOUT-B/ PWMOUT-B 9 VIN-C/DIN-C/FIN-C 23 DOUT-E/ PWMOUT-E 10 VIN-H/DIN-H 24 DOUT-F/ PWMOUT-F 35 DOUT-C/ PWMOUT-C 36 DOUT-D/ PWMOUT-D 37 ALARM 38 GND (DATA) 11 +VREF-B 25 DATA-OUT 39 READY-OUT 12 VIN-D/DIN-D/FIN-D 26 DATA-IN 40 BSL-IN 13 -VREF-B 27 VIN-I/DIN-I 41 VIN-J/DIN-J 14 not used 28 +BAT (+12 V, +24 V) 42 +BAT2 (+12 V,+24 V) Unshaded positions are Junior Power Timer pins. Shaded positions are Micro Timer pins. See above for wire, seal, pin number and crimping tool information. The IQAN tool kit is found in the IQAN accessories datasheet. 8

Supply voltage 6 Installation Supply voltage Before any installation of the IQAN system can take place, make sure the ignition lock is turned off and the battery is disconnected. Emergency stop Make sure an Emergency Stop disconnecting the power supply, is easily accessible at any time. The figure below shows how to connect the emergency stop. Connecting of Supply Voltage The supply voltage, should be within the operating interval, see Appendix A, on page 22. Connect the supply voltage to +BAT, position 28 and -BAT, position 15. Protect the control by using a fuse. Requisite fuse level should be 20 A, fast (F). * Emergency Stop 20 A +BAT, pos. 28 + - -BAT, pos.15 * Symbol for disconnecting switch for battery, ignition lock and other fuses. Connecting the emergency stop and voltage supply. NOTICE Do not use the chassis as the negative terminal. Supplying a high current draw system If the is used to control several digital outputs simultaneously, it is recommended to source power thru the +BAT2 and -BAT2 positions in addition to the +BAT and -BAT. Change the fuse to 30A, fast. * + - Emergency Stop 30 A +BAT2, pos. 42 +BAT, pos. 28 -BAT2, pos.29 -BAT, pos.15 * Symbol for disconnecting switch for battery, ignition lock and other fuses. Connecting the emergency stop and voltage supply. 9

Communication 6 Installation Communication RS232 and modem connection The has an RS232 interface for communicating with the programming software, IQANdevelop. A flying lead, panel-mount, adapter cable, 5030089, may be connected to the TOC8 to provide an HR12 connector interface. This will match to the PC communication cable provided in the IQANdevelop software package. Instead of using recommended Parker adapter cable 5030089, a DB9-F serial connector may be wired to connect directly to a PC. The basic wiring for use of a DB9-F serial connector is shown below. READY_OUT, pos. 39 BSL_IN, pos. 40 1 6 GND (DATA), pos. 38 DATA_IN, pos. 26 DATA_OUT, pos. 25 Connecting DB9-F for RS232 usage. When using the recommended Parker adapter cable, 5030089, the connection from TOC8 to PC can be made with the IQANdevelop included cable, 5030024, and from TOC8 to modem with a separately purchased cable, 5030080. NOTICE The Remote Diagnostic cable 5030080 must be used when connecting a modem to the TOC8. Use of the MDM-RS232 cable 5030024 may damage the modem. Using a modem Start modem communication as follows: Attach the modem to the TOC8. Power up the modem first, then power up or reset the TOC8. Wait 45 seconds for the modem to initialize. The TOC8 will blink a double fast yellow code to indicate the modem is attached. Dial up the modem -- the TOC8 will automatically answer. A fast yellow-red double blink indicates ringing. If a Reset Master command is sent or a new application is downloaded, the TOC8 will reset. Modem communication will not cease but with some equipment the blink code will change from the fast double yellow blink code to the normal status single blink. CAN connection The module has a CAN interface that can be used to connect to SAE J1939 or similar bus for communication between and other systems. 10

Reference voltage, VREF 6 Installation Connecting to CAN interface The interface is connected from the engine s SAE J1939 interface to the CAN_H and the CAN_L. EXAMPLE Connect the SAE J1939 CAN_H and CAN_L pins to the CAN_H, position 16 and the CAN_L, position 30 on the. Customer provided connector 120 ohm CAN-H, pos. 16 CAN-L, pos. 30 Connecting a SAE J1939 interface to the TOC8 CAN hub. Reference voltage, VREF The is internally equipped with two voltage regulators to generate the reference voltages VREF A and VREF B. These reference voltages will feed different kinds of sensors. -VREF-B, pos. 13 +VREF-B, pos. 11 -VREF-A, pos. 4 +VREF-A, pos. 2 VREF positions. NOTICE Maximum load for the VREF A and VREF B is different according to 12/24 Vdc power supply, see Appendix A, on page 22. 11

Voltage inputs 6 Installation Voltage inputs Connecting sensors to the voltage inputs The sensor signal range must be 0-5 Vdc. To detect signal errors such as short circuits or interruptions the active signal range should be within 0.5-4.5 Vdc. [V] 5 Error detection range Active signal 0 Active signal range. t Error detection range The current consumption related to the voltage input is negligible. The positive terminal of the sensor is connected to the +VREF position and the corresponding negative terminal to the -VREF position. The sensor signal is connected to appropriate VIN position. EXAMPLE Connect the positive and negative terminals of the position sensor to +VREF-A, position 2, and -VREF-A, position 4, respectively. Then connect the sensor signal to VIN-A, position 3. -VREF-A, pos. 4 VIN-A, pos. 3 +VREF-A, pos. 2 Position Sensor Connecting VREF-A and sensor signal VIN-A. NOTICE The negative terminal of the sensor must not be connected to the chassis. Maximum load for each VREF position, see Appendix A, on page 22. 12

Voltage inputs 6 Installation Connecting a 2-wire temperature sensor to voltage in When you connect a PTC (positive temperature coefficient) temperature sensor you may need to use a pull up resistor on the input signal. Please check the technical data for your specific temperature sensor. EXAMPLE Connect the negative terminal of the temperature sensor to -VREF-A, position 4, and the signal to VIN-A, position 3. The pull up resistor will be connected between VIN-A, position 3 and +VREF-A, position 2. pull up +VREF-A pos 2 VIN-A pos 3 Sensor -VREF-A pos 4 Connecting -VREF-A and temperature sensor signal VIN-A. The pull up resistor value for a R 25 =2000Ω, PTC sensor is 4,7 KΩ. 13

Voltage inputs 6 Installation Connecting switches to the voltage inputs Switches could be connected to the voltage inputs, to create a digital on/off signal. The switches may be connected to +VREF and VIN respectively. The current consumption for the voltage input is negligible. It is also possible (recommended) to connect system voltage +BAT to the voltage input through a switch. EXAMPLE Connect the positive and negative terminals of the switch to +VREF-A, position 2, and VIN-A, position 3, respectively. +VREF-A, pos. 2 switch VIN-A, pos. 3 Connecting a switch to VIN-A. NOTICE Maximum load for each VREF position, see Appendix A, on page 22. EXAMPLE Connect the positive and negative terminals of the switch to +BAT and VIN-A, position 3, respectively. +BAT VIN-A, pos. 3 switch Connecting a switch to VIN-A and +BAT. 14

Frequency inputs 6 Installation Frequency inputs Connecting sensors to the frequency inputs For the frequency ranges and trigger levels, see Appendix A, on page 22. Simple frequency sensor The positive terminal of the frequency sensor is connected to the +VREF and the negative terminal to the -VREF respectively. The sensor signal is connected to a FIN position. If the current consumption for the sensor exeeds the maximum load for the VREF, the sensor could be connected to the BAT positions. EXAMPLE Connect the positive and negative terminals of the frequency sensor to +VREF-A, position 2, and -VREF-A, position 4, respectively. Then connect the sensor signal to FIN-A, position 3. +VREF-A, pos. 2 OR FIN-A, pos. 3 -VREF-A, pos. 4 Frequency sensor Connecting of frequency sensor. NOTICE The negative terminal of the sensor must not be connected to the chassis. Maximum load for each VREF position, see Appendix A, on page 22. 15

Current outputs 6 Installation Current outputs The current output signals control proportional valves and devices. For the current range see Appendix A, on page 22. Dither frequency and amplitude To obtain the best performance from proportional valves the control produces a direct current (DC) with a dither. The dither frequency and the dither amplitudes can be adjusted in IQANdevelop software. Depending on what kind of valve is to be used, a certain recommended dither frequency/amplitude set-up can be supplied by Parker Hannifin Corporation in order to obtain an optimized valve hysteresis. Both frequency and amplitudes will then be set using IQANdevelop software. Connecting loads to current outputs Connecting a load, e.g. one proportional valve, to the current output is done by using the COUT/CRET pair positions. EXAMPLE Positive direction: Connect the proportional valve to the COUT-A, position 17 and the CRET-A+, position 18 respectively. Negative direction: Connect the proportional valve to the COUT-A, position 31 and the CRET-A-, position 32 respectively. COUT-A+ COUT-A- CRET-A- CRET-A+ Direction Valve Connecting a load to the current output. 16

Digital outputs 6 Installation Digital outputs The digital outputs control relays and on/off valves. For the maximum load per output see Appendix A, on page 22. Soft start Soft start is used whenever start-up is required to be smoother than the normal procedure offers. A desired ramp function provides the smoother start-up according to the figure below. The ramp function is set up in IQANdevelop software. Output signal [V] Max Soft start t The Soft start function. Peak and Hold The Peak and Hold feature makes it possible to decrease the voltage to the valve solenoid. Shortly after a valve has been activated, the voltage can be decreased to a lower level, sufficient to maintain the position of the valve, but also reducing the heat generated in the valve (due to this lower voltage). The reducing of heat, is the primary reason for selecting the Peak and Hold feature. Both the peak time and the hold value are set up in IQANdevelop software. Output signal Hold value Peak t The Peak and Hold value voltage graph. 17

Digital outputs 6 Installation Connecting loads to digital outputs Connecting of loads to the digital outputs such as on/off valves is done by using the DOUT positions and chassis as ground. Protection against voltage transients A clamping diode must be placed between the digital output and ground, as close to the load as possible, to protect the output against high voltage transients. For example: use diode: 1N5408 (3A/1000V). Depending on load, other clamping diodes might be used instead. EXAMPLE Connect the on/off valve to the digital output using the DOUT-A, position 21, and the chassis as ground. A clamping diode must be placed as close to the load as possible, see figure below. DOUT-A, pos.21 d1 Connecting a load to the digital output. If the load is controlled in parallel with another system, the digital output shall be protected with a diode. +BAT DOUT-A, pos.21 d2 d1 Digital output protected with a diode. 18

PWM outputs 6 Installation PWM outputs The PWM outputs (Pulse Width Modulation) control pilot valves. Maximum load should not exceed 3.0 A per output. Connecting loads to PWM outputs The load is connected between the PWMOUT and the chassis ground. Maximum load per output, see Appendix A, on page 22. Protection against voltage transients A clamping diode must be placed between the output and ground, as close to the load as possible, to protect the output against high voltage transients. For example: use diode: 1N5408 (3A/1000V). Depending on load, other clamping diodes might be used instead EXAMPLE Positive direction: Connect the load between the PWMOUT-A, position 22, and the chassis as ground. Negative direction: Connect the load between the PWMOUT-B, position 21, and the chassis as ground. A clamping diode will be placed as close to the pilot valve as possible. PWMOUT-A, pos. 21 PWMOUT-B, pos. 22 d2 d1 Connecting a load to the PWM output. Directional valve 19

Start-up procedures 7 Start-up 7 Start-up Start-up procedures This chapter contains instructions for action to be taken in connection with the initial start. WARNING Risk of injury! If the control system is not fitted properly, the machine could move uncontrollably. The machine s engine shall not be started before the control system is completely fitted and its signals are verified. Starting the control system Start the control system as follows: Prior to start, all modules and cables are to be fitted correctly. Check fuses, i.e. make sure that the supply voltage to the modules is equipped with the correct fuse. Make sure that connections for supply voltage and return lines are correct in the cable s conductor joint. Make sure an emergency stop is installed. The emergency stop should disconnect the supply voltage to all modules. Alternatively, the emergency stop may also shut off the diesel engine or a dump valve, and with that, depressurize the hydraulic system. Prepare for system start WARNING Make sure no one is in dangerous proximity to the vehicle to avoid injuries when it starts. Prepare for the initial system start as follows: The engine for the hydraulic system s pump shall be in off position. Make sure that all connectors are properly connected. Turn on the control system. Make sure that voltage is being supplied to all modules; the power/status diode shall be illuminated on all modules. Also, make sure that the master is in contact with all modules by reading the master s display. Make sure the emergency stop is functioning properly. Start the system Start the system as follows: Start the engine for the hydraulic system s pump, assuming that the above mentioned inspections have been carried out and shown correct values. Calibrate and adjust input and output signals according to the instructions related to the master menu system and check each and every output function carefully. 20

Start-up procedures 8 System Diagnostics 8 System Diagnostics The yellow blinking LED on the top of the unit indicates normal status. The TOC8 control indicates error status through the red blinking LED and a yellow secondary blinking pattern. This gives an immediate indication as to the cause of an error. Yellow/ red, status LED Green, power on The location of the LED indicators on the control. The green LED indicates power on. The yellow/red LED, will be blinking a pattern showing status, and also when an error has been detected. To get futher information about the error messages, see Appendix B, on page 25. 21

Technical Overview Appendix A Appendix A Technical Overview Absolute maximum ratings T A = +25 C (unless otherwise specified) Parameter Limit values min. typ. max. Unit Remark Operating ambient temperature, T A Storage temperature 40 40 +80 +100 C Voltage supply, V BAT 6 36 V Analog input levels, VIN -36 36 V Digital input levels, DIN -36 36 V Load current, COUT A internally limited Load current, DOUT A internally limited Load current, total all outputs 20 A Environmental ratings Parameter Limit values min. typ. max. Unit Remark EMI ISO 11452-2 ISO 14982 ISO11452-4 ISO7637-2 50 50 V/m V/m ESD EN 61000-4-2 (external) 15 kv CAN-bus length a 100 m Mechanical environment IEC 60068-2-64 Fh (random, 10-250 Hz) IEC 60068-2-27 Es (shock, 11ms) IEC 60068-2-29 Eb (bump, 6ms) Climate environment IEC 60068-2-18 Rb2 (water) IEC 60068-2-30 Db (var1: damp, cyclic) IEC 60068-2-3 Ca (damp, heat steady state) IEC 60068-2-2-Bb (heat) IEC 60068-2-1 Ab (cold) IEC 60068-2-14 Nb (change of temperature) 0.1 40 40 3 72 240 72 16 10 x 6 g 2 /Hz g g min hour hour hour hour hour Chemical environment IEC 60068-2-52 Kb (salt mist, cyclic) 72 hour 30kPa, 12.5 l/min 25-55 C, 95% RH 44 C, 93% RH 70 C -30 C -30-70 C a. CAN is only used with IQANsimulate, SAE J1939 or during factory testing of the control. Instruction book, 22

Technical Overview Appendix A Operation -40 C < T A <+70 C (unless otherwise specified) Parameter Limit values min. typ. max. Unit Remark Ambient temperature (no load), T A 40 +75 C Voltage supply, V BAT 9 34 V Output voltage, VREF 4.9 5.0 5.1 V Maximum load current, VREF A, B V BAT =14V V BAT = 28V 50 20 ma VREF A+ VREF B Current supply V BAT =14V V BAT =28V 90 105 ma outputs = off I/O -40 C < T A < +70 C (unless otherwise specified) Parameter Limit values min. typ. max. Unit Remark VIN (Voltage input) Signal range low 0 0.05 V Signal range high 4.9 5.0 5.1 V Input resistance 62 kω Signal resolution 5 mv Total unadjusted error 15 35 mv (vref as source) FIN (Frequency input) Trigger level high 4.0 V @1kHz Trigger level low 1.8 V @1kHz Frequency range 2 10000 Hz 5V source Pulse width 10 ms Frequency resolution < 1kHz < 5kHz < 10kHz 0,8 20 80 Hz f 2 ----------------------------- 1, 25 10 6 Instruction book, 23

Technical Overview Appendix A I/O (cont.) Parameter Limit values min. typ. max. Unit Remark DOUT (Digital output) Load current each channel active (A,B,C,D,E,F) Load current one channel in each group (A or B, C or D, E or F) Voltage drop (V BAT -V DOUT ) load I L = 0,5A load I L = 3A 0.2 0.8 3 A 4 A The DOUT are divided into three groups. V Short Circuit current limit 6 A PWMOUT (Pulse Width Modulation output) Load current each channel active (A,B,C,D,E,F) Load current one channel in each group (A or B, C or D, E or F) Voltage drop (V BAT -V DOUT ) load I L = 0,5A load I L = 3A 0.2 0.8 3 A 4 A The PWMOUT are divided into three groups. V Short Circuit current limit 6 A PWM frequency 25 2000 Hz COUT (Current out) Signal range 50 1800 ma Resolution 0.7 ma Load 4 W Total unadjusted error ±5 ma T A = 25 C Deviation between modules a ±2 ma Power supply rejection V BAT = 9... 18V V BAT = 24... 34V 1 1 ma R L =6 W -25 W Load regulation V BAT =14V, R L =4... 9 W V BAT =28V,R L =22... 34 W ±1 ±3 ma Dither frequency 25 150 Hz Dither amplitude 0 500 ma a. In case of switching modules, note that the current values differs between different modules. Instruction book, 24

Error codes, messages and actions Appendix B Appendix B Error codes, messages and actions If one of the following errors is detected, a message will be presented via the LED error codes on the control. In some cases, the control will stop operating or at least shut down the outputs, to increase safety. WARNING Don t use the machine if an error message or error code is activated. LED indicator showing different TOC8 modes Status Blink (yellow light) Invalid application Modem connected Modem ring (yel./red) Normal operation IQANSimulate (red) Fatal software (red) Error code Error Primary Blink (red) Error category Secondary Blink (yellow) Error description 1 Output error 1 Input error 1 VREF error 1 Supply or checksum 2 Temp. error none 3 Wrong modem SIM code 3 Missing SIM code The following sections will present what measures to take for different error situations. Instruction book, 25

Error codes, messages and actions Appendix B ERROR: OUTPUT HIGH Situation Error code Action TOC8 Comment COUT: Current return low or high Error 1-1 Active output shuts off. Check wiring and loads COUT: Both directions commanded Error 1-1 Active output shuts off. Check application DOUT: Overload Error 1-1 Active output shuts off. Check load PWMOUT: Both directions commanded Error 1-1 Active output shuts off. Check application COUT/DOUT: Internal driver failure Error 6 Active output shuts off. Contact supplier ERROR: INPUT Situation Error code Action TOC8 Comment VIN: > specified max or < specified min Error 1-2 Active input goes to error value. Check wiring and sensors ERROR: VREF Situation Error code Action TOC8 Comment VREF_ < 4,9 V Error 1-3 - Check voltage VREF_ > 5,1 V Error 1-3 - Check voltage Instruction book, 26

Error codes, messages and actions Appendix B LOW/ HIGH SUPPLY VOLTAGE Situation Error code Action TOC8 Comment +BAT < 8,5 V Error 1-4 - Check voltage supply +BAT > 34 V Error 1-4 - Check voltage supply ERROR: PARAMETER Situation Error code Action TOC8 Comment Parameter error (checksum) Error 1-4 - Contact supplier HIGH TEMPERATURE Situation Error code Action TOC8 Comment Internal temperature > max temp Internal temperature sensor error Error 2 - Check ambient temperature Error 6 - Contact supplier ERROR: COMMUNICATION Situation Error code Action TOC8 Comment Modem error (wrong SIM code) Modem error (missing SIM code) Error 3-1 - Enter proper code in IQANdevelop Error 3-2 - Enter proper code in IQANdevelop ERROR: SOFTWARE Situation Error code Action TOC8 Comment Software error Error 6 The unit stops operating. Contact supplier. Instruction book, 27

Dimensioning of the module Appendix C Appendix C Dimensioning of the module 7 mm/m6(x2) 32 67 52 75 142 164 60 Unit = mm Instruction book, 28

For latest information visit our website www.iqan.com Information in this instructionbook is subject to change without notice Parker Hannifin Electronic Controls Division SE-435 35 Mölnlycke Sweden Tel +46 31 750 44 00 Fax +46 31 750 44 21 www.parker.com Parker Hannifin Electronic Controls Division 1651 N. Main Street Morton, IL 61550 USA Tel +1 309 266 2200 Fax +1 309 266 6674 Publ no HY33-8304-IB/UK Edition 2011-08-10