FCC DoC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Similar documents
FCC DoC TEST REPORT. TESTED : Sep. 01 to 02, 2010 APPLICANT : LOGITECH FAR EAST LTD.

VCCI TEST REPORT. TESTED : June 22 to 23, 2010 APPLICANT : LOGITECH FAR EAST LTD.

FCC DoC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC DoC TEST REPORT. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC Test Report (15.249)

FCC SUPPLEMENTARY TEST REPORT

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC TEST REPORT. SendFar Technology Co., Ltd.

FCC TEST REPORT (RFID)

FCC TEST REPORT. LAB ADDRESS: No. 47, 14 th Ling, Chia Pau Tsuen, Linko Hsiang 244, Taipei Hsien, Taiwan, R.O.C.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

FCC TEST REPORT th Lin, Chiapau Tsun, Linko, Taipei, Taiwan, R.O.C. No. 19, Hwa Ya 2 nd Rd., Kueishan, Taoyuan, Taiwan, R.O.C.

RADIO TEST REPORT (AS/NZS 4268)

FCC TEST REPORT (Z-Wave)

FCC Verification Test Report

Supplemental Transmit Simultaneously Test Report

RADIO TEST REPORT (AS/NZS 4268)

TEST REPORT. The submitted sample of the above equipment has been tested for according to the requirements of the following standards:

FCC TEST REPORT. Summit Data Communications, Inc. Advance Data Technology Corporation

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC Verification Test Report

TEST REPORT. Table of Contents

FCC TEST REPORT. Cisco-Linksys LLC. 121 Theory Drive, Irvine, CA (USA) Advance Data Technology Corporation

Equipment : UPS Brand Name : Test Model No. : SRT3000RMXLW-IEC Multiple Listing :

FCC Test Report RF141003E10B-1. Report No.: PY FCC ID: EX6150. Test Model: Received Date: Apr. 17, Test Date: Apr. 22 to July 21, 2015

FCC Test Report (Zigbee-Thread)

FCC TEST REPORT. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

FCC TEST REPORT. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

TEST REPORT. Table of Contents

FCC Test Report (IEEE )

FCC 47 CFR PART 15 SUBPART B

FCC TEST REPORT. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

FCC 47 CFR PART 15 SUBPART B TEST REPORT

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

FCC 47 CFR PART 15 SUBPART B TEST REPORT

FCC Test Report (Zigbee)

FCC Test Report. TD-W8961N, TD-W8961ND (refer to item 3.1 for more details)

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

FCC TEST REPORT (WLAN )

FCC TEST REPORT (Bluetooth)

Declaration of Conformity (DoC)

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

FCC Test Report (Zigbee-Thread)

FCC TEST REPORT (15.407)

FCC/IC Test Report. : 2AOIMOMATA1 Equipment authorization required : SDoC IC ID

FCC Part 15 Subpart B

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Test Report. Product Name : IPC Model No.

TEST REPORT. 4F,-4, No.669 Jingping Rd., Zhonghe City, TaiPei county 235, Taiwan R.O.C.

FCC TEST REPORT (15.407)

FCC Test Report (BT-LE)

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

FCC 47 CFR PART 15 SUBPART B TEST REPORT. For. External USB 2.0 HDD Enclosure

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

FCC Test Report. Report No.: RF160715C03 FCC ID: PY Test Model: EX6150v2. Received Date: Jul. 11, Test Date: Jul. 15 ~ Aug.

FCC Test Report. Zebra Technologies Corporation. Zebra Technologies Corporation

FCC TEST REPORT (WLAN )

FCC TEST REPORT. for. 47 CFR, Part 15, Subpart C. SPORTON International Inc.

FCC Test Report R Lumewave IoT Platform

FCC Test Report. Report No.: RF170922C07 FCC ID: 2AGDE-WRT3061. Test Model: WRT3061. Received Date: Sep. 22, 2017

CE EMC TEST REPORT. TESTED : June 22 to 23, 2010 APPLICANT : LOGITECH FAR EAST LTD.

FCC CLASS B COMPLIANCE REPORT (DoC)

FCC DoC Test Report. Series Model: xxxzeus-248yt-xxxxxxx (The "y" is E & S,"x" Can be 0 to 9 & A to Z,"-" or blank ) Received Date: Feb.

DFS TEST REPORT. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

FCC Test Report. Report No.: RF160715C03-1 FCC ID: PY Test Model: EX6150v2. Received Date: Jul. 11, Test Date: Jul. 15 ~ Aug.

TEST REPORT. Issued for:

CERTIFICATE. Issued Date: May 21, 2008 Report No.: R-ITUSP02V01

FCC TEST REPORT. according to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class B Digital Device. Equipment : IPC Bare Bone System

EMI Test Report. : BTv4.0 Dual Mode USB Dongle

FCC Test Report (WLAN)

CE EMC TEST REPORT. LAB LOCATION : No. 81-1, Lu Liao Keng, 9 Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien, Taiwan

FCC CLASS B COMPLIANCE REPORT (DOC)

FCC 15B Test Report. : ac/a/b/g/n + Bluetooth 4.2 module (please refer to section for more details.)

Neutron Engineering Inc.

IC Test Report. SPORTON INTERNATIONAL INC. No. 52, Hwa Ya 1 st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

FCC Test Report. Report No.: RF180206E02 FCC ID: 2ACH3UKAZA2A0. Test Model: UKAZA2A001. Received Date: Feb. 06, Test Date: Feb.

FCC TEST REPORT (15.407)

CERTIFICATE. Issued Date: Aug. 20, 2009 Report No.: R-ITUSP02V01

FCC 15B Test Report. : Bluetooth 4.2 module (BLE only) (Refer to item for more details)

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

C E R T I F I C A T I O N

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

FCC TEST REPORT (PART 22)

TEST REPORT. Table of Contents

FCC Test Report. RBS50, SRR60, SRS60 (refer to item 3.1 for more details)

TRANSMITTER MODEL: KAS-2030M

EN RF Test Report

FCC Test Report (WLAN)

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

FCC C2PC Test Report

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

EMI Test Report. W66N220 Commerce Court, Cedarburg, Wisconsin 53012, USA : CISPR 32:2015/COR1:2016, Class B AS/NZS CISPR 32:2015, Class B

Transcription:

FCC DoC TEST REPORT REPORT NO. : FD981207H01 MODEL NO. : N-I0004 RECEIVED : Dec 07, 2009 TESTED : Dec. 08, 2009 ISSUED: Dec. 14, 2009 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 27 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by TAF, NVLAP or any government agencies. The test results in the report only apply to the tested sample. Report No.: FD981207H01 1 Report Format Version 3.0.0

Table of Contents 1 CERTIFICATION...3 2 SUMMARY OF TEST RESULTS...4 2.1 MEASUREMENT UNCERTAINTY...4 3 GENERAL INFORMATION...5 3.1 GENERAL DESCRIPTION OF EUT...5 3. DESCRIPTION OF TEST MODE...5 3.2 DESCRIPTION OF SUPPORT UNITS...6 3.3 CONFIGURATION OF SYSTEM UNDER TEST...7 4 EMISSION TEST...8 4.1 CONDUCTED EMISSION MEASUREMENT...8 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT...8 4.1.2 TEST INSTRUMENTS...8 4.1.3 TEST PROCEDURE...9 4.1.4 DEVIATION FROM TEST STANDARD...9 4.1.5 TEST SETUP...9 4.1.6 EUT OPERATING CONDITIONS...10 4.1.7 TEST RESULTS...11 4.2 RADIATED EMISSION MEASUREMENT...15 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT...15 4.2.2 TEST INSTRUMENTS...16 4.2.3 TEST PROCEDURE...17 4.2.4 DEVIATION FROM TEST STANDARD...17 4.2.5 TEST SETUP...18 4.2.6 EUT OPERATING CONDITIONS...18 4.2.7 TEST RESULTS (MODE 1)...19 4.2.8 TEST RESULTS(MODE 2)...21 5 PHOTOGRAPHS OF THE TEST CONFIGURATION...23 6 INFORMATION ON THE TESTING LABORATORIES...26 7 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB...27 Report No.: FD981207H01 2 Report Format Version 3.0.0

1 CERTIFICATION PRODUCT : Remote control Harmony 300 BRAND NAME : Logitech MODEL NO. : N-I0004 TESTED : Dec. 11, 2009 TEST SAMPLE : ENGINEERING SAMPLE APPLICANT : LOGITECH FAR EAST LTD. STANDARDS : FCC Part 15, Subpart B, Class B CISPR 22: 1997, Class B ICES-003: 2004, Class B ANSI C63.4-2003 The above equipment (Model: N-I0004) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample s EMC characteristics under the conditions specified in this report. PREPARED BY :, DATE: Dec. 14, 2009 ( Midoli Peng, Specialist ) TECHNICAL ACCEPTANCE :, DATE: Dec. 14, 2009 ( Ray Yeh, Deputy Manager ) APPROVED BY :, DATE: Dec. 14, 2009 ( May Chen, Deputy Manager ) Report No.: FD981207H01 3 Report Format Version 3.0.0

2 SUMMARY OF TEST RESULTS Standard Test Type Result Remarks FCC Part 15 Subpart B, Class B CISPR 22: 1997, Class B ICES-003: Class B Conducted Test PASS Radiated Test PASS Meets Class B Limit Minimum passing margin is -10.35 db at 16.348 MHz Meets Class B Limit Minimum passing margin is -5.09 db at 144.00 MHz Note: The limit for radiated test was performed according to CISPR 22, which was specified in FCC PART 15 Subpart B 15.109(g). Also the limits of ICES-003: 2004 and CISPR 22 are same. 2.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Measurement Conducted emissions Radiated emissions(30mhz-1ghz) Value 2.45 db 3.83 db Report No.: FD981207H01 4 Report Format Version 3.0.0

3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT Remote control Harmony 300 MODEL NO. POWER SUPPLY POWER CORD DATA CABLE SUPPLIED N-I0004 DC 3V from batteries or DC 5V from host equipment NA I/O PORT USB port x 1 ASSOCIATED DEVICES NOTE: JEM recharge USB cable (Shielded, 0.69m) NA 1. The EUT was pre-tested under the following test modes for three different axes placements: Test Mode Description Mode A X-Y plane Mode B X-Z plane Mode C Y-Z plane From the above modes, the worst emission level was found in Mode A. Therefore only the test data of the modes were recorded in this report individually. 2. For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual. 3. DESCRIPTION OF TEST MODE The EUT was tested with the following modes: Conducted test Test Mode Description Mode 1 Remote + USB Radiated test Test Mode Description Mode 1 Remote + USB Mode 2 Remote control only Report No.: FD981207H01 5 Report Format Version 3.0.0

3.2 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. No. Product Brand Model No. Serial No. FCC ID 1 PC DELL DCSM G84QL1S FCC DoC 2 MONITOR DELL E228WFPc CN-OX765G-64180-88P-09ZM FCC DoC 3 PRINTER CANON K10202 FASF84644 FCC DoC 4 MODEM ACEEX 1414 0206026775 IFAXDM1414 5 KEYBOARD DELL SK-8115 MY-0J4635-71619-67V-0114 FCC DoC 6 MOUSE DELL M056UOA FOROOBSN FCC DoC No. Signal cable description 1 0.69m foil unshielded wire, USB Connector, with two cores. 2 1.8m braid shielded wire, VGA & DVI connector, with two cores. 1.8 m braid shielded wire, terminated with DB25 and centronics connector via metallic frame, w/o 3 core 4 1 m braid shielded wire, terminated with DB25 and DB9 connector via metallic frame, w/o core. 5 1.9m foil shielded wire, USB Connector, w/o core. 6 1.8m foil shielded wire, USB Connector, w/o core. NOTE: All power cords of the above support units are non shielded (1.8m). Report No.: FD981207H01 6 Report Format Version 3.0.0

3.3 CONFIGURATION OF SYSTEM UNDER TEST For Remote + USB mode USB cable (0.69m) 3. PRINTER 1. PC EUT 2. MONITOR 4. MODEM 5. KEYBOARD 6. MOUSE TEST TABLE For Remote control only mode EUT TEST TABLE Report No.: FD981207H01 7 Report Format Version 3.0.0

4 EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT TEST STANDARD: FCC Part 15, Subpart B (Section: 15.107) CISPR 22: 1997 (section 5) ICES-003: 2004 (Class A: section 5.2) (Class B: section 5.3) FREQUENCY (MHz) Class A (dbuv) Class B (dbuv) Quasi-peak Average Quasi-peak Average 0.15-0.5 79 66 66-56 56-46 0.50-5.0 73 60 56 46 5.0-30.0 73 60 60 50 NOTE: (1) The lower limit shall apply at the transition frequencies. (2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz. (3) All emanations from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above. 4.1.2 TEST INSTRUMENTS DESCRIPTION & MANUFACTURER ROHDE & SCHWARZ Test Receiver Line-Impedance Stabilization Network (for EUT) Line-Impedance Stabilization Network (for Peripheral) MODEL NO. SERIAL NO. CALIBRATED DATE CALIBRATED UNTIL ESCS 30 100287 Mar. 05, 2009 Mar. 04, 2010 KNW-407 8-1395-12 May 04, 2009 May 03, 2010 ENV-216 100072 June 08, 2009 June 07, 2010 RF Cable (JYEBAO) 5DFB COACAB-001 Dec 15, 2009 Dec 14, 2010 50 ohms Terminator 50 3 Nov. 05, 2009 Nov. 04, 2010 Software BV ADT_Cond_V7.3.7 NA NA NA Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in Shielded Room No. A. 3 The VCCI Con A Registration No. is C-817. Report No.: FD981207H01 8 Report Format Version 3.0.0

4.1.3 TEST PROCEDURE The basic test procedure was in accordance with ANSI C63.4-2003 (section 7), CISPR 22 (section 9) and ICES-003: 2004 (section 4). a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected to the power mains through a line impedance stabilization network (LISN). Other support units were connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference. c. The frequency range from 150 khz to 30 MHz was searched. Emission levels under (Limit-20dB) were not recorded. 4.1.4 DEVIATION FROM TEST STANDARD No deviation 4.1.5 TEST SETUP Vertical Reference Ground Plane Test Receiver 40cm EUT 80cm LISN Horizontal Reference Ground Plane Note: 1. Support units were connected to second LISN. 2. Both of LISNs (AMN) are 80 cm from EUT and at least 80 cm from other units and other metal planes support units. For the actual test configuration, please refer to the related Item - Photographs of the Test Configuration. Report No.: FD981207H01 9 Report Format Version 3.0.0

4.1.6 EUT OPERATING CONDITIONS 1. Turn on the power of all equipment. 2. PC runs the test program "Logitech runclient.bat" to enable EUT under transmission/receiving condition continuously via one USB cable. Report No.: FD981207H01 10 Report Format Version 3.0.0

4.1.7 TEST RESULTS TEST MODE Mode 1 PHASE Line (L) INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS 120Vac, 60 Hz 6dB BANDWIDTH 9 khz 22 deg. C, 60 % RH, 1015 hpa TESTED BY Leo Peng Freq. Corr. Reading Value Emission Level Limit Margin No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 4.441 0.15 36.93-37.08-56.00 46.00-18.92-2 6.488 0.18 37.30-37.48-60.00 50.00-22.52-3 7.168 0.19 46.59-46.78-60.00 50.00-13.22-4 12.633 0.30 37.66-37.96-60.00 50.00-22.04-5 15.361 0.36 43.95-44.31-60.00 50.00-15.69-6 16.695 0.40 45.82-46.22-60.00 50.00-13.78 - REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD981207H01 11 Report Format Version 3.0.0

TEST MODE Mode 1 PHASE Neutral (N) INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS 120Vac, 60 Hz 6dB BANDWIDTH 9 khz 22 deg. C, 60 % RH, 1015 hpa TESTED BY Leo Peng Freq. Corr. Reading Value Emission Level Limit Margin No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 0.974 0.08 32.92-33.00-56.00 46.00-23.00-2 4.441 0.17 39.42-39.59-56.00 46.00-16.41-3 6.486 0.20 38.51-38.71-60.00 50.00-21.29-4 7.166 0.21 47.37-47.58-60.00 50.00-12.42-5 14.676 0.38 45.01-45.39-60.00 50.00-14.61-6 16.348 0.42 49.23-49.65-60.00 50.00-10.35 - REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD981207H01 12 Report Format Version 3.0.0

TEST MODE Mode 2 PHASE Line (L) INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS 120Vac, 60 Hz 6dB BANDWIDTH 9 khz 25 deg. C, 55 % RH, 1015 hpa TESTED BY Leo Peng Freq. Corr. Reading Value Emission Level Limit Margin No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 0.205 0.17 40.63-40.80-63.42 53.42-22.62-2 0.463 0.08 30.98-31.06-56.65 46.65-25.59-3 0.888 0.06 32.16-32.22-56.00 46.00-23.78-4 1.434 0.06 32.00-32.06-56.00 46.00-23.94-5 2.934 0.10 26.93-27.03-56.00 46.00-28.97-6 8.773 0.21 33.67-33.88-60.00 50.00-26.12 - REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD981207H01 13 Report Format Version 3.0.0

TEST MODE Mode 2 PHASE Neutral (N) INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS 120Vac, 60 Hz 6dB BANDWIDTH 9 khz 25 deg. C, 55 % RH, 1015 hpa TESTED BY Leo Peng Freq. Corr. Reading Value Emission Level Limit Margin No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 0.205 0.18 46.36-46.54-63.42 53.42-16.88-2 0.271 0.15 36.95-37.10-61.08 51.08-23.99-3 0.341 0.12 36.27-36.39-59.17 49.17-22.78-4 0.463 0.09 32.30-32.39-56.65 46.65-24.26-5 0.955 0.08 24.83-24.91-56.00 46.00-31.09-6 8.875 0.24 29.06-29.30-60.00 50.00-30.70 - REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD981207H01 14 Report Format Version 3.0.0

4.2 RADIATED EMISSION MEASUREMENT 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT TEST STANDARD: FCC Part 15, Subpart B (Section: 15.109) CISPR 22: 1997 (section 6) ICES-003: 2004 (Class A: Section 5.4) (Class B: Section 5.5) FOR FREQUENCY BELOW 1000 MHz (47 CFR Part 15 Subpart B) FREQUENCY Class A (at 10m) Class B (at 3m) (MHz) uv/m dbuv/m uv/m dbuv/m 30 88 90 39.1 100 40.0 88 216 150 43.5 150 43.5 216-960 210 46.4 200 46.0 Above 960 300 49.5 500 54.0 FOR FREQUENCY BELOW 1000 MHz (CISPR 22) FREQUENCY (MHz) Class A (at 10m) Class B (at 10m) dbuv/m dbuv/m 30 230 40 30 230-1000 47 37 Note: The limit for radiated test was performed according to CISPR 22, which was specified in FCC PART 15 Subpart B 15.109(g) and ICES-003 clause 7. LIMIT OF RADIATED EMISSION OF FCC PART 15, SUBPART B FOR FREQUENCY ABOVE 1000 MHz FREQUENCY (MHz) Class A (dbuv/m) (at 3m) Class B (dbuv/m) (at 3m) PEAK AVERAGE PEAK AVERAGE Above 1000 80.0 60.0 74.0 54.0 Note: (1) The lower limit shall apply at the transition frequencies. (2) Emission level (dbuv/m) = 20 log Emission level (uv/m). (3) All emanation from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above. Report No.: FD981207H01 15 Report Format Version 3.0.0

FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators) Highest frequency generated or Upper frequency of measurement used in the device or on which the Range (MHz) device operates or tunes (MHz) Below 1.705 30 1.705 108 1000 108 500 2000 500 1000 5000 Above 1000 5 th harmonic of the highest frequency or 40 GHz, whichever is lower 4.2.2 TEST INSTRUMENTS DESCRIPTION & CALIBRATED CALIBRATED MODEL NO. SERIAL NO. MANUFACTURER DATE UNTIL ADVANTEST Spectrum Analyzer U3751 160200410 July. 17, 2009 July. 16, 2010 ADVANTEST Spectrum Analyzer U3772 160100280 Sep. 21, 2009 Sep. 20, 2010 HP Pre_Amplifier 8449B 3008A01922 Sep. 25, 2009 Sep. 24, 2010 ROHDE & SCHWARZ Test Receiver ESVS 30 841977/002 Oct. 28, 2009 Oct. 27, 2010 SCHAFFNER(CHASE) Broadband Antenna CBL6112B 2798 April 29, 2009 April 28, 2010 Schwarzbeck Horn_Antenna BBHA9120-D1 D123 Sep. 21, 2009 Sep. 20, 2010 Schwarzbeck Horn_Antenna BBHA 9170 BBHA9170153 Jan. 23, 2009 Jan. 22, 2010 RF Switches MP59B 6100175593 Sep. 01, 2009 Aug. 31, 2010 RF Cable 8DFB STBCAB-001 Sep. 01, 2009 Aug. 31, 2010 Software ADT_Radiated_ V7.6.15.9.2 NA NA NA CT Antenna Tower & Turn Table NA NA NA NA CORCOM AC Filter MRI2030 024/019 NA NA Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The horn antenna, HP preamplifier (model: 8449B) and Spectrum Analyzer (model: U3772) are used only for the measurement of emission frequency above 1GHz if tested. 3. The test was performed in Open Site No. B. 4. The VCCI Site Registration No. is R-847. 5. The FCC Site Registration No. is 92753. 6. The CANADA Site Registration No. is IC 7450G-2. Report No.: FD981207H01 16 Report Format Version 3.0.0

4.2.3 TEST PROCEDURE The basic test procedure was in accordance with ANSI C63.4-2003 (section 8), CISPR 22 (section 10) and ICES-003: 2004 (section 4). a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 10-meter open field site. The table was rotated 360 degrees to determine the position of the highest radiation. b. The EUT was set 10 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the turn table was turned from 0 degrees to 360 degrees to find the maximum reading. e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum hold mode when the test frequency is below 1 GHz. f. The test-receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets average limit, measurement with the average detector is unnecessary. NOTE: 1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at frequency below 1GHz. 2. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz for Peak detection at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz. 3. For measurement of frequency above 1000 MHz, the EUT was set 3 meters away from the interference-receiving antenna. 4.2.4 DEVIATION FROM TEST STANDARD No deviation Report No.: FD981207H01 17 Report Format Version 3.0.0

4.2.5 TEST SETUP EUT& Support Units 80cm Ant. Tower 10m 3m-above 1GHz Turn Table 1-4m Variable Ground Plane Test Receiver For the actual test configuration, please refer to the related item Photographs of the Test Configuration. 4.2.6 EUT OPERATING CONDITIONS For test mode 1: 1. Turn on the power of all equipment. 2. PC runs the test program "Logitech runclient.bat" to enable EUT under transmission/receiving condition continuously via one USB cable For test mode 2: 1. The EUT under typical use condition. Report No.: FD981207H01 18 Report Format Version 3.0.0

4.2.7 TEST RESULTS (MODE 1) TEST MODE Mode 1 FREQUENCY RANGE 30-1000 MHz INPUT POWER (SYSTEM) DETECTOR FUNCTION & BANDWIDTH 120Vac, 60 Hz Quasi-Peak, 120kHz ENVIRONMENTAL CONDITIONS 25 deg. C, 60 % RH, 1015 hpa TESTED BY Eagle Chen No. ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10 M Freq. (MHz) Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) 1 123.95 23.17 QP 30.00-6.83 4.00 H 337 10.62 12.55 2 144.00 24.91 QP 30.00-5.09 4.00 H 269 12.56 12.35 3 223.23 24.27 QP 30.00-5.73 4.00 H 37 11.85 12.42 4 244.09 26.63 QP 37.00-10.37 4.00 H 333 12.98 13.65 5 312.80 25.67 QP 37.00-11.33 3.13 H 40 9.97 15.70 6 475.30 30.75 QP 37.00-6.25 2.13 H 320 10.91 19.84 REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD981207H01 19 Report Format Version 3.0.0

TEST MODE Mode 1 FREQUENCY RANGE 30-1000 MHz INPUT POWER (SYSTEM) DETECTOR FUNCTION & BANDWIDTH 120Vac, 60 Hz Quasi-Peak, 120kHz ENVIRONMENTAL CONDITIONS 25 deg. C, 60 % RH, 1015 hpa TESTED BY Eagle Chen No. ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10 M Freq. (MHz) Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) 1 120.00 23.16 QP 30.00-6.84 1.00 V 36 10.56 12.60 2 143.06 19.68 QP 30.00-10.32 1.00 V 20 7.34 12.34 3 192.00 18.16 QP 30.00-11.84 1.00 V 342 7.34 10.82 4 223.23 21.68 QP 30.00-8.32 1.00 V 42 9.26 12.42 5 240.20 24.09 QP 37.00-12.91 1.00 V 20 10.67 13.42 6 475.30 30.53 QP 37.00-6.47 1.00 V 344 10.69 19.84 REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD981207H01 20 Report Format Version 3.0.0

4.2.8 TEST RESULTS(MODE 2) TEST MODE Mode 2 INPUT POWER DC 3V from batteries FREQUENCY RANGE 30-1000 MHz DETECTOR FUNCTION & BANDWIDTH Quasi-Peak, 120kHz ENVIRONMENTAL CONDITIONS 25 deg. C, 60 % RH, 1015 hpa TESTED BY Eagle Chen No. ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10 M Freq. (MHz) Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) 1 123.95 22.67 QP 30.00-7.33 4.00 H 340 10.12 12.55 2 144.00 24.51 QP 30.00-5.49 4.00 H 272 12.16 12.35 3 223.23 23.57 QP 30.00-6.43 4.00 H 39 11.15 12.42 4 244.09 25.83 QP 37.00-11.17 4.00 H 335 12.18 13.65 5 312.80 25.07 QP 37.00-11.93 3.13 H 43 9.37 15.70 6 475.30 30.35 QP 37.00-6.65 2.13 H 323 10.51 19.84 REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD981207H01 21 Report Format Version 3.0.0

TEST MODE Mode 2 INPUT POWER DC 3V from batteries FREQUENCY RANGE 30-1000 MHz DETECTOR FUNCTION & BANDWIDTH Quasi-Peak, 120kHz ENVIRONMENTAL CONDITIONS 25 deg. C, 60 % RH, 1015 hpa TESTED BY Eagle Chen No. ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10 M Freq. (MHz) Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) 1 120.00 21.76 QP 30.00-8.24 1.00 V 39 9.16 12.60 2 143.06 18.48 QP 30.00-11.52 1.00 V 24 6.14 12.34 3 192.00 16.96 QP 30.00-13.04 1.00 V 345 6.14 10.82 4 223.23 20.58 QP 30.00-9.42 1.00 V 45 8.16 12.42 5 240.20 22.79 QP 37.00-14.21 1.00 V 23 9.37 13.42 6 475.30 29.03 QP 37.00-7.97 1.00 V 347 9.19 19.84 REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD981207H01 22 Report Format Version 3.0.0

5 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: FD981207H01 23 Report Format Version 3.0.0

RADIATED EMISSION TEST(MODE 1) Report No.: FD981207H01 24 Report Format Version 3.0.0

RADIATED EMISSION TEST(MODE 2) Report No.: FD981207H01 25 Report Format Version 3.0.0

6 INFORMATION ON THE TESTING LABORATORIES We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and approved by the following approval agencies according to ISO/IEC 17025. USA Germany Japan Norway Canada R.O.C. Netherlands Singapore Russia FCC, NVLAP TUV Rheinland VCCI NEMKO INDUSTRY CANADA, CSA TAF, BSMI, NCC Telefication GOST-ASIA (MOU) CERTIS (MOU) Copies of accreditation certificates of our laboratories obtained from approval agencies can be downloaded from our web site: www.adt.com.tw/index.5/phtml. If you have any comments, please feel free to contact us at the following: Linko EMC/RF Lab: Tel: 886-2-26052180 Fax: 886-2-26052943 Hsin Chu EMC/RF Lab: Tel: 886-3-5935343 Fax: 886-3-5935342 Hwa Ya EMC/RF/Safety/Telecom Lab: Tel: 886-3-3183232 Fax: 886-3-3185050 Email: service@adt.com.tw Web Site: www.adt.com.tw The address and road map of all our labs can be found in our web site also. Report No.: FD981207H01 26 Report Format Version 3.0.0

7 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB No any modifications are made to the EUT by the lab during the test. ---END--- Report No.: FD981207H01 27 Report Format Version 3.0.0

CONSTRUCTION PHOTOS OF EUT Page 1

Page 2

Page 3

Page 4