Technical Information Output Configurations for PLUS+1 Controllers powersolutions.danfoss.com

Similar documents
Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com

S42 Pump Electrical Displacement Control (EDC)

H1B Motor Electric Proportional Control L1, L2

Electrohydraulic Actuators PVEA/H/S

S45 Pump Electric Proportional Control

MP1 Pumps Non-Feedback Proportional Electric (NFPE) Control

Electrohydraulic Actuator Type PVEP / PVEP-F

Sensor EMD Speed Sensor

MAKING MODERN LIVING POSSIBLE. Electrical Installation. Pulse Pickup KPP PPU. powersolutions.danfoss.com

Sensors Q625A Remote Setpoint Module

MAKING MODERN LIVING POSSIBLE. Electrical Installation. M46 Pumps HC EDC. powersolutions.danfoss.com

Sensors ACE100B DC Millivolt Input Amplifier

MCX103A Non-Contact Rotary Position Sensor. Technical Information

ACX104B Potentiometer Rotary Position Sensor. Technical Information

Ultrasonic Controller/Sensor. Technical Information

POWER SYSTEM MODE STATUS

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

MCHXXX Control Handle

Global Application Development Centers. Creating and proving solutions to customer challenges. A truly global team working for. you.

PLUS+1 High Current Controller Family

Technical Information. FDCA Fan Drive Control Assembly

DIGITAL CONTROL OF ELECTRO-HYDRAULIC STEERING TEST BENCH

Zero-Drift, High Voltage, Bidirectional Difference Amplifier AD8207

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Electronic regulator for PWM controlled proportional solenoid valves FABER -

NXP Repetitive short-circuit performances

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

Dual, High Voltage Current Shunt Monitor AD8213

HB-25 Motor Controller (#29144)

Doc. No: part_numbering_110.doc Phone (860) Dolphin Road Rev: A Date: Fax (860) Bristol, CT, 06010

TECHNICAL DATASHEET #TDAX022420

Hydraulic Valve Interface Products

New Eagle PWM to Analog Converter

Analog amplifier RA. RE Edition: Replaces:

Simple-H User Manual

High Voltage, Bidirectional Current Shunt Monitor AD8210

Features. +12V to +36V MIC nf. High-Side Driver with Overcurrent Trip and Retry

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

High Voltage Current Shunt Monitor AD8211

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

High Voltage, Bidirectional Current Shunt Monitor AD8210

Electro-Hydraulic Components Electronic Controllers Machine Management Systems. Working out integration between related technologies

Castle Creations, INC.

Simple Bridge Stand Alone H-Bridge Data Sheet Revision 1 August 2005

Single-Supply, 42 V System Difference Amplifier AD8206

Configuration Worksheet Instructions

Electrohydraulic Actuators PVE, Series 4 and PVHC

Single-Supply 42 V System Difference Amplifier AD8205

Application Note. Brushless DC Motor Control AN-1114

High Voltage, Current Shunt Monitor AD8215

New Eagle PWM to Analog Converter

L9914. All silicon voltage regulator. Features. Description. Multiwatt8

Autonomous Robot Control Circuit

Infocal 9 Energy calculator

BASIC-Tiger Application Note No. 059 Rev Motor control with H bridges. Gunther Zielosko. 1. Introduction

Designing with the Si9976DY N-Channel Half-Bridge Driver and LITTLE FOOT Dual MOSFETs

Electrohydraulic Actuators PVE, Series 4 and PVHC

Adaptive Power MOSFET Driver 1

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Application Note AN- 1117

Building an autonomous light finder robot

Implementation Of Solid State Relays For Power System Protection

Digital Interface Card DEC005000

High Voltage, Current Shunt Monitor AD8215

Parallel Configuration of H-Bridges

Programmable with Electronic Assistant Simulink

YVPC ELECTRONIC REGULATOR FOR PWM CONTROLLED SOLENOID

Precision Voltage Control System

Considerations for Choosing a Switching Converter

Microprocessors B Lab 4 Spring Motor Control Using Pulse Width Modulation (PWM)

Speed Control Of Transformer Cooler Control By Using PWM

MP V-to-15V, 700mA, Bipolar Stepper-Motor Driver with Integrated MOSFETs

EE152 Final Project Report

with Electronic Assistant

NX Series Inverters. HVAC Pocket Programming Guide

DeviceCraft Revision #1 11/29/2010

Application Note: CBLIO-ISO1-xM Cables for the Class 5 D-Style SmartMotor, Revised: 11/9/2016.

Overview. Features. Specifications. Important Notes

Analog Servo Drive 25A20DD

POLOLU DUAL MC33926 MOTOR DRIVER FOR RASPBERRY PI (ASSEMBLED) USER S GUIDE

AH5792 SINGLE PHASE HALL EFFECT LATCH SMART FAN MOTOR CONTROLLER. Description. Pin Assignments. Features. Applications

LM1801 Battery Operated Power Comparator

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

IMP2526 IMP2526. Dual USB High-Side PowerP Switch. Dual switch esistance ance at 3/5V MIC2526 pin compatible POWER MANAGEMENT.

STARTER / GENERATOR MOTOR CONTROLLER

AN2129 APPLICATION NOTE

DC-Motor Driver circuits

Functional Safety Application Guide

L9473 Car alternator voltage regulator Features Description

Pololu Dual G2 High-Power Motor Driver for Raspberry Pi

Electro-Hydraulic Components Electronic Controllers Machine Management Systems. Working out integration between related technologies

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Bend Sensor Technology Electronic Interface Design Guide

LM555 and LM556 Timer Circuits

Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)

PHASE BRUSHLESS DC MOTOR CONTROLLER/DRIVER FEATURES

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Transcription:

MAKING MODERN LIVING POSSIBLE Technical Information Output s for PLUS+1 Controllers powersolutions.danfoss.com

Output s for PLUS+1 Controllers Revisions Revision History Table of Revisions Date Page Changed Rev 17 Sep 2013 All New layout EA 11 Mar 2013 6 Single Pole Double Throw Switch drawing updated DA 17 Oct, 2008 Various Various content update and literature type changed from CA Tech Note to Technical Information 11 Oct, 2005 5 Changed sentence Use digital... B 13 Jul, 2005 1 PVG 120 photo updated A 2 520L0922 Rev EA Sep 2013

Output s for PLUS+1 Controllers Contents PLUS+1 Controllers Configurable Outputs Driving Different Types of Loads... 4 Driving a Relay or ON/OFF Valve... 4 Driving an Incandescent Lamp... 6 Driving a Bidirectional Proportional Valve... 7 Driving a Unidirectional Proportional Valve... 9 Driving a PVE Valve... 9 Driving a 4-20 ma Device... 9 FMEA Considerations Open Wire to Controller... 10 Open Battery+ Wire to Controller... 10 Open Wire to Load... 11 About This Manual This publication is intended to share circuits, products and other useful application information not otherwise found in other Danfoss publications. It is written to inform and aid the reader in the successful application of Danfoss products. 520L0922 Rev EA Sep 2013 3

Output s for PLUS+1 Controllers PLUS+1 Controllers Configurable Outputs Driving Different Types of Loads PLUS+1 controllers have configurable outputs that can be used to drive a variety of different loads. Danfoss recommends the following ways for using the PLUS+1 outputs to drive different types of loads. Driving a Relay or ON/OFF Valve Danfoss recommends using a digital output for ON/OFF loads, such as a relay or valve. This encompasses outputs labeled as DOUT or DOUT/PVG Pwr. The recirculating diode across the relay coil is optional. The internal diode will provide the same functionality. These outputs always provide a high voltage (sourcing battery voltage) as the output when in the ON state. Logic circuits Optional Relay 2295 If you need to use a multi-function PWM output for ON/OFF loads, then set the configuration in the application program to one of the digital output selections. This can be push/pull, sourcing, or sinking. (PinConfig = 0, 1, or 2) Sourcing and Sinking options are not available for all pins. Please refer to the API specification for the particular hardware. 4 520L0922 Rev EA Sep 2013

Output s for PLUS+1 Controllers Driving a Relay or ON/OFF Valve (continued) It is recommended to use the push/pull configuration for every situation where a load is exclusively driven by the controller. Sourcing configuration (PinConfig = 1 or 0) Sourcing or Push/Pull Optional Relay Sinking configuration (PinConfig = 2 or 0) 2296 Sinking or Push/Pull Optional Relay 2297 In the Sinking configuration, with the load tied to there is the potential for up to 5 milliamps leakage current through the output when it is in the OFF state. 520L0922 Rev EA Sep 2013 5

Output s for PLUS+1 Controllers Driving a Relay or ON/OFF Valve (continued) Use sourcing or sinking when there are other sources tied in parallel, such as a jog switch. Sourcing Single Pole Single Throw Switch 2395 Sourcing Single Pole Double Throw Switch 2396 Driving an Incandescent Lamp Danfoss only recommends using a digital output for driving incandescent lamps. This encompasses outputs labeled as DOUT or DOUT/PVG Pwr. These outputs always provide a high voltage (sourcing battery voltage) as the output when in the ON state. Logic circuits Lamp It is not recommended to use multi-function PWM outputs for driving incandescent lamps. There are limitations when driving incandescent lamps from multi-function outputs. An incandescent lamp has an inrush current. Inrush is a spike in current just as you turn the lamp on when the filament is cold. Multi-function outputs have a hard current limit which will trip the output off if this limit is exceeded. When driving an incandescent lamp this can happen even though the average current requirements for the lamp are well within the output pin s drive capability. Depending on the inrush current, it cannot be guaranteed that the multi-fuction output will reliably drive an incandescent lamp. This has sometimes been effectively addressed by setting the output to open loop PWM (PinConfig = 3) and then ramping the PWM percentage from 0 to 100 percent, but this is not guaranteed to work for all applications. 2298 6 520L0922 Rev EA Sep 2013

Output s for PLUS+1 Controllers Driving a Bidirectional Proportional Valve Option 1 H bridge configuration for single coil Certain output pin pairs may be set for the H bridge configuration. Please refer to the API specification for the pinouts on a particular hardware. This is an open loop PWM configuration (PinConfig = 7). H-bridge Load H-bridge 2299 PWM Closed Loop Current Load PWM Closed Loop Current 2300 Option 2 closed loop current controlled configuration for single coil You may also use two outputs configured for closed loop current control to drive a bi-directional valve. Certain output pin pairs may be used for this configuration (PinConfig = 8). Set the current command to the desired milliamps. Please refer to the API specification for the pinout pairs available on a particular hardware. 520L0922 Rev EA Sep 2013 7

Output s for PLUS+1 Controllers Driving a Bidirectional Proportional Valve (continued) Option 3 push/pull configuration for dual coil You may also use two outputs to drive a bidirectional dual coil valve such as a dual coil EDC when wired as shown below. This configuration will allow you to check the resistance of the coils for more accurate diagnostics. Setting PinConfig = 4 on both outputs will give closed loop current control. Refererence FMEA Considerations, pages 10 and 11. PWM Closed Loop Current Coil A PWM Closed Loop Current Coil B 2302 PWM Closed Loop Current Coil A PWM Closed Loop Current Coil B 2303 8 520L0922 Rev EA Sep 2013

Output s for PLUS+1 Controllers Driving a Unidirectional Proportional Valve It is recommended to use PWM configuration for unidirectional proportional valves. This may be set for open loop PWM (PinConfig = 3) or closed loop current control (PinConfig = 4 or 5). Recirculating diodes across the load should never be used if the valve requires closed loop current control. They are optional for open loop PWM control. Refererence FMEA Considerations, pages 10 and 11. PWM Open Loop Load 2304 Driving a PVE Valve When driving a Danfoss PVE valve, it is recommended to use the PVE output configuration (PinConfig = 6). Set the PWM frequency at 4000 Hz. PWM Open Loop PVE 2305 Driving a 4-20 ma Device Driving a 4-20 ma device is not recommended. The minimum controllable current is presently about 10 ma in the closed loop push/pull configuration. 520L0922 Rev EA Sep 2013 9

Output s for PLUS+1 Controllers FMEA Considerations One consideration during a system FMEA (Failure Mode Effects Analysis) on an application is the possibility of an open wiring connection. Here are three examples. Open Wire to Controller Effects of an Open Losing the ground connection can cause the battery current to find another path to ground if it is available. When the load is grounded externally, rather than through the controller, such a path is available. Current will find its way through the load even when the output is in the OFF state. This may result in unintentional movement of the function that is controlled by the load. Below is a simple schematic to show how this can happen. The arrows indicate the path of current. Load Open 2306 The only way to remove the current completely is to return the load current back to the controller, through another output. If you are driving an EDC type load (dual coil) and are driving both coils to get a forward / reverse type function, this could be done by driving one coil bi-directionally with no additional outputs consumed. If there are enough valves connected to the controller to provide multiple current paths, you might be able to reduce the amount of current in each valve enough so that it is no longer above the threshold of any one valve. If you have multiple ground connections to the controller, you might be able to reduce the occurrence of the fault enough so that it no longer a significant risk (rates below 100 on the System FMEA.) You may also be able to improve the wiring integrity to minimize the occurrence of the fault. Open Battery+ Wire to Controller Open Battery+ Wire Losing the Battery + connection can cause the battery current to find another path to ground if it is available. When the load is tied to Battery+ externally, rather than through the controller, such a path is available. Current will find its way through the load even if the output is in the OFF state. This may result in unintentional movement of the function that is controlled by the load. 10 520L0922 Rev EA Sep 2013

Output s for PLUS+1 Controllers Open Battery+ Wire to Controller (continued) Below is a simple schematic to show how this can happen. The arrows indicate the path of current. Open Load 2307 The only way to remove the current completely is to source the load current from the controller, through another output. If you are driving an EDC type load (dual coil) and are driving both coils to get a forward / reverse type function, this could be done by driving one coil bi-directionally with no additional outputs consumed. If there are enough valves connected to the controller to provide multiple current paths, you might be able to reduce the amount of current in each valve enough so that it is no longer above the threshold of any one valve. If you have multiple power connections to the controller, you might be able to reduce the occurrence of the fault enough so that it no longer a significant risk (rates below 100 on the System FMEA). You may also be able to improve the wiring integrity to minimize the occurrence of the fault. Open Wire to Load Open Load Wire If you are using a dual coil device with a common ground for bidirectional control, this could be a problem if the common ground wire is open. When using this configuration, the current can flow out of the sourcing output and will try to find a path to ground. If you have the other coil connected to a low impedance source, the current can flow through both coils. This may cause unintended or erroneous movement of the controlled device. Connecting the non-active coil to a high impedance source will prevent this from occurring. See the recommended configurations Open Battery+ Wire to Controller, page 10 and above, for driving this type of load. 520L0922 Rev EA Sep 2013 11

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Danfoss Your Strongest Partner in Mobile Hydraulics. Go to www.powersolutions.danfoss.com for further product information. Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Please contact the Danfoss Power Solution representative nearest you. Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmuellerinverter.com Turolla www.turollaocg.com Valmova www.valmova.com Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com Local address: Danfoss Power Solutions US Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions 22F, Block C, Yishan Rd Shanghai 200233, China Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 520L0922 Rev EA Sep 2013 www.danfoss.com Danfoss A/S, 2013-09