Description of Potential Errors in Laser Thickness Measurement Systems

Similar documents
Technical Explanation for Displacement Sensors and Measurement Sensors

PHYS 1112L - Introductory Physics Laboratory II

In-line measurements of rolling stock macro-geometry

1393 DISPLACEMENT SENSORS

Automatic gauge control (AGC)/

SECTION HOLLOW METAL DOORS AND FRAMES

MEASUREMENT APPLICATION GUIDE OUTER/INNER

Mission Statement. State Steel strives to provide quality products and services at competitive

Design for Manufacturability Guide

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

Measurement technology for inline quality inspection in plastics production. More Precision

FIBEROPTIC DISPLACEMENT SENSOR. with Analog Output

Improving Product Quality with Advanced Hot Width Measurement and Automatic Width Control in Hot Strip Mill of Bokaro Steel Plant

Optical Isolator Tutorial (Page 1 of 2) νlh, where ν, L, and H are as defined below. ν: the Verdet Constant, a property of the

ACEEE Int. J. on Electrical and Power Engineering, Vol. 03, No. 02, May 2012

Double Bar Plate Dowels for Saw-Cut Contraction Joints

High precision laser sensors. for dimensional measurement. TPreciCura line

ADVANCES IN NON-CONTACT LENGTH AND SPEED MEASUREMENTS WITH ZERO SPEED AND AUTOMATIC DIRECTION DETECTION FOR PROCESS AUTOMATION 1

MEASURING SYSTEMS FOR THE STEEL INDUSTRY

Metrology Prof.Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Physics 248 Spring 2009 Lab 1: Interference and Diffraction

L-742 Ultra-Precision Roll Alignment System for Printing Presses/Paper Machines

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

Fastener Hole Crack Detection Using Adjustable Slide Probes

Chapter 29/30. Wave Fronts and Rays. Refraction of Sound. Dispersion in a Prism. Index of Refraction. Refraction and Lenses

FIBER OPTIC DISPLACEMENT SENSORS. with Analog Output

NEW SITUATION IN COLD MILLS SINCE VTLG THICKNESS MEASUREMENT WITH LASER IS POSSIBLE

Test Review # 9. Physics R: Form TR9.15A. Primary colors of light

Bringing Answers to the Surface

Week IX: INTERFEROMETER EXPERIMENTS

Hybrid Surface Contour Measuring Machine FORMTRACER CS-5000

Section Member. H (in.) WT. lb./ft. Pull Out Strength Slip Resistance Torque Size / Thread All Series

Corso di Studi di Fabbricazione

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

GLOSSARY OF TERMS SECTION 8

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

New generation of welding and inspection systems

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

thin and flexible probes factory calibration certificate with traceability High precision Analog output: DC 35 khz (depending on probe type)

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic

Sensors & Applications Glass Industry. More Precision

Precision Folding Technology

Test Review # 8. Physics R: Form TR8.17A. Primary colors of light

Severance Offers Four Types of Hand Files To Solve Virtually Every Application

High-Accuracy Surface Scanning Method

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics

Digital CMOS Laser Sensor GV Series. Up to 1 m. Away. Stable detection of. metal targets. Innovative solution for. black targets

Laser Application DAL7020 DFL7020 DFL7161 DFL7160 DFL7341 DFL7360FH DFL7361 DFL7560L. Ablation Process. Stealth Dicing.

MINIATURE METAL BELLOWS COUPLINGS

DCB-FA 330 DOUBLE COLUMN AUTOMATIC MITER BANDSAW MACHINE

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

SOLDER PASTE STENCIL MANUFACTURING METHODS AND THEIR IMPACT ON PRECISION AND ACCURACY

Mini-MAG Positioning Products

Watermark Labelstm. a division of lustre-cal corporation

Material Parameter Measurement (MPM)

SECTION BULLET- RESISTANT DOORS

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

DIRECT METAL LASER SINTERING DESIGN GUIDE

( This link will provide you with a list of all ISO-6983 G-Codes

Digital CMOS Laser Sensor GV Series. Up to 1 m. Away. Stable detection of. metal targets. Innovative solution for. black targets

RB&W. GLOBAL LIGHTWEIGHT MATERIAL PRESENTATION April 14, SPAC Applications 1

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Test procedures Page: 1 of 5

Advances in slabs defects inspection with Conoscopic Holography. Ignacio Alvarez, J.M. Enguita (UniOvi) J. Marina, R.

Thin Lenses. Lecture 25. Chapter 23. Ray Optics. Physics II. Course website:

THICKNESS CHECK NON-CONTACT THICKNESS MEASUREMENT OF FLAT PRODUCTS

MY NEW WA 80. FEATURES, OPTIONS.

Steel Plate in Oil Rig Blowout Preventer Valves

Chapter 7. Optical Measurement and Interferometry

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Fig. (8.1) types of riveted joints

AP Physics Problems -- Waves and Light

The Renishaw Additive Manufacturing formula

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Sealing Elements. Technical Handbook O-rings. 15. Tolerances and Surface Imperfections

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

ADVANCE VISUAL ULTRASONIC DACON INSPECTION SERVICES TESTING INSPECTION

CATALOG No. US FORMTRACER CS Hybrid Surface Contour Measuring Machine

WORKSHOP DRAWING & DESIGN STANDARDS

Solutions for Lithium Ion Battery Manufacturing

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

Applications of Maskless Lithography for the Production of Large Area Substrates Using the SF-100 ELITE. Jay Sasserath, PhD

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Sheet Metal Forming. Part 1

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

A Revolution in Profile Measurement

Applications and Setups

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Manufacturing Workmanship Standards. KSO Rev 1

Catalog 2017/2018. ROENTGEN Over 100 years experience in quality improvement you can t beat it!

Radial Polarization Converter With LC Driver USER MANUAL

3M Impact Protection Profile Installation System Instructions

Wire and tube Drawing

Area Detection Fiber Sensors

Transcription:

Description of Potential Errors in Laser Thickness Measurement Systems Advanced Gauging Technologies, L.L.C. Scott A. Cook, President & C.E.O. October 7, 2016

Introduction Since 1998, Advanced Gauging Technologies (A.G.T.) has been the market leader in isotope thickness gauging for steel service centers throughout North America. In 2012 the company began development of a laser thickness gauge with countless hours of testing and development. The AGT800 Laser Thickness Gauge & S.P.C. Reporting System is the result, and was introduced in 2013. The first system was commissioned in 2014, and later that year the gauging system was an American Metals Market top five finalist for Best Innovation Product. In 2015, the company was awarded U.S. Patent #9,151,595 for laser thickness gauge and method including passline angle correction. Since its introduction, the AGT800 has steadily gained market acceptance and popularity. AGT800 Laser Thickness Gauge The AGT800 Laser Thickness Gauge & S.P.C. Reporting System is a complete thickness profile measurement system developed to measure any opaque material in strip, coil or sheet form. New versions are currently being designed to gauge cold and hot steel and aluminum plate, along with wall thickness of pipe and pole. Customized C-frames are manufactured with two (or three*) Keyence LK-G/H series Class 2 laser sensors. Each sensor has individual adjustability in order to retain collinearity. Ultra high speed, high accuracy CCD sensors are used to measure distance and the thickness is interpolated. Built-in air knives protect glass sensor windows and ensure repeatability by keeping them free of oil and debris. Our proprietary S.P.C. reporting system provides fast and reliable thickness measurements and data storage. Direct benefits include documented compliance with ISO and various other quality specifications, improved process control, increased productivity and scrap reduction. *Two laser sensors are used to measure flat rolled material. One sensor is mounted below the strip, and the other above. Optionally, an additional sensor can be mounted above the strip. This allows the top two sensor readings to compare readings and determine material passline angle. A Passline Angle Correction factor is then applied.

Issues that Affect Overall Measurement Accuracy Following is a list of issues that can affect the overall measurement accuracy of laser thickness gauging systems in general. 1. Design of laser sensors 2. Shape of the laser beam spot 3. Linearity of laser sensors 4. Alignment of the lasers sensors, and collinearity of the laser beams 5. Perpendicularity of the laser sensors to the material to be measured or material passline angle changes 6. Cleanliness of laser sensors and laser sensor covers 7. Thermal expansion of C-frame, accuracy of C-frame temperature monitoring and accuracy of temperature correction routine/algorithm 8. Tuning fork effect of C-frame design 9. Surface cleanliness of material to be measured 10. Electronic noise 11. Filtering

Ways These Factors Are Minimized in the AGT800 System Here are the design elements incorporated into the AGT800 thickness gauging system that serve to reduce the measurement errors as much as possible. 1. Design of laser sensors Since a charge coupled device (CCD) has digital output characteristics for each pixel, the errors caused by gradual outputs generated at the edge of pixels was a barrier to higher accuracy. As a countermeasure, Keyence developed a linearized CCD (LI-CCD ) that outputs the position of reflected light in a pixel, achieving excellent accuracy that is two times higher than conventional models. In addition, the dedicated design of the sensor has achieved a speed that is 25 times faster and sensitivity ten times better than conventional models. Refer to the following image from Keyence for more details.

2. Shape of the laser beam spot Surfaces such as aluminum slabs that appear flat, will often contain minute projections and depressions once magnified. This microscopic surface roughness can often cause measurement errors with conventional narrow spot sensors. By using sensor heads with wider beam spots, the effect of the uneven surface is averaged and stable measurements of coarse targets are possible. For this reason, the AGT800 incorporates these wide beam laser spots. The difference in beam widths is illustrated in the following graphic from Keyence. 3. Linearity of laser sensors All laser sensors have some degree of linearity, meaning their accuracy will be dependent on the position of material within the measurement window. The AGT800 utilizes Keyence LK-H series CCD laser displacement sensors. These are the highest quality sensors available in the industry, and boast linearity specifications of 0.02% of full scale. For this reason, minor vertical movement of the slab within the measurement range will have negligible effect on the measurement accuracy.

4. Alignment of the laser sensors, and collinearity of the laser beams. It is paramount that the top and bottom laser beams be aimed at the same spot on the target material, and are installed so the beams are collinear. It is so important, in fact, that A.G.T. received a patent for the way we address collinearity issues with respect to floating material. The AGT800 incorporates specific design elements allowing simple laser sensor alignment adjustments to be made, assuring laser beam collinearity, and thereby eliminating this potential source of measurement error. The above diagram from our U.S. Patent #9,151,595 shows the need to correct for lack of laser beam collinearity. The following formula is used in these cases. Ta = Tm x cos θ Do x sin θ - Db Ta is actual thickness Tm is measured thickness θ is the angle between the target material surface and an imaginary line drawn perpendicular to the laser beam Do is S1 versus S2 Collinearity Offset Db is S1 versus S2 Beam Dynamics Correction

5. Perpendicularity of the laser sensors to the material to be measured or material passline angle changes The laser sensor beams and the target material must be perpendicular for the most accurate measurements. In the AGT800 design, the laser sensors are mounted in an extremely rigid C-frame, maintaining the proper perpendicularity at all times. However, the angle of the material itself may change. In these cases a third laser sensor may be installed. The top two sensor readings can then be compared to determine material passline angle, and our patented Passline Angle Correction factor can be applied. 6. Cleanliness of laser sensors and laser sensor covers With any type of optical gauging system, cleanliness of the laser sensors is critical. To ensure accurate measurements, each of the laser sensors will be covered with an individual glass window. The AGT800 C-frames will also incorporate individual air knives to help keep the glass windows as clean as possible. 7. Thermal expansion of C-frame, accuracy of C-frame temperature monitoring and accuracy of temperature correction routine/algorithm The AGT800 C-frame design includes a temperature sensor to monitor C-frame temperature at all times. Any time the gauge is calibrated, the C-frame temperature is stored by the software. Going forward, the current temperature is compared to the calibration temperature and a temperature correction is made. Ta = Tm - TCF * (TMPc - TMPn) Ta is actual thickness Tm is measured thickness TCF is Temperature Correction Factor TMPn is C-frame temperature at last calibration TMPc is C-frame temperature at current time

8. Tuning fork effect of C-frame design The AGT800 C-frames are assembled from HSS (hollow structural section) 8 x 8 inch (top arm), 8 x 4 inch (bottom arm) and HSS 8 x 8 inch (double uprights). In addition, upper and lower gussets are incorporated into the design. No fasteners are used. Instead, all components are welded together. This extra rigid C-frame construction serves to minimize the tuning fork effect as much as possible. 9. Surface cleanliness of material to be measured The most repeatable and accurate thickness readings will be maintained when the material to be measured is as clean as possible. Compressed air may be used to keep the sensors clear of debris, scale, mist, etc. Thin oil films are not an issue for this gauge design. 10. Electronic noise The Keyence LK-H series laser sensors produce digital displacement measurements within the sensors themselves. This eliminates analog signals being transmitted through cables over long distances, which means there is no electronic noise present. 11. Filtering The AGT800 design incorporates a combination of several types of data filtering. a. Moving Average. The measurement values are set with a moving average in the range of 1 to 262,144 times. This number will be set for best possible performance in the AGT800 system. b. Median Filter. This function applies a 7, 15 or 31-point median filter to prevent measurement fluctuations by ignoring sudden changes in the measured value. This function is useful when the target moves fast. This number will be set for the best possible performance in the AGT800 system. c. High-Pass Filter. Abrupt changes are ignored and only moderate changes are detected, based on a specific cutoff frequency. d. Low-Pass Filter. Moderate changes are ignored and only abrupt changes are detected, based on a specific cutoff frequency.