Wiring Information. Blinds & Shades

Similar documents
DECORATOR COMFORT CONTROL (DCC)

MULTILINK. Installation and Operating Instruction

Radio Technology Somfy. Pocket Programming Guide

Sonesse 30 Programming & Operation Instructions

Radio Technology Somfy. Pocket Programming Guide

Radio Frequency Remote-Control FM Remote-Control Receiver/ Transmitter

Radio Technology Somfy. Pocket Programming Guide

Altus RTS, Orea RTS & Sonesse RTS Programming

B.E.G. Controls. B.E.G. Controls. The lighting control professionals. Wall Station Collection

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

CordLift WireFree Programming & Operation Instructions CT-32RT-12V

Energy Savings Material Savings Minimize Costs Ideal Uses

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Somfy RTS Motor Programming Instructions Motor Programming Instructions have been rewritten by

Operating Instructions

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

THE NEW WALL-MOUNTED CONTROL UNITS FROM SOMFY. Sensitive Touch for Motion

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

Regal Series Recessed Flatwalls

The DIY Lantern Blind Wiring Diagrams & Programming Instructions

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

The baton drawn system ( with components shown below ) is the most widely used hardware in guest rooms. Eyelet

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

HL25K INSTALLATION INSTRUCTIONS. Hidden Link Shelf Top Standard IR Receiver

Blue Point Engineering

Radio Link Starter Kit

UBLS - Under Bed Lift Swivel Mechanism

LSM PF 5 - Lift System Medium with Push Up Flap

LOM-15 CD-LOM15-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LOM-15. Duplex Receptacle

FinishLynx Interface. Includes: Power requirements: 9 VDC Power Adapter (included) Size: Approximately 5 x 3 x 2 Approximate weight: 5.57oz.

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

QA Quad Arm for Large Screens

AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

POWERRISE PLATINUM TECHNOLOGY REMOTE CONTROL GUIDE

XT-DL-IRK. DinkyLink IR Receiver Kit. Plasma / LCD / LED / CFL Friendly IR Receiver INSTALLATION INSTRUCTIONS

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

Crestron CLS-C6 Series ilux Integrated Lighting System User Guide

Soft Tones Sheer Shadings

The World s Most Advanced Wireless Door Control System

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

5 yr. Station Level Paging Adapter. Model 300PBX-SC LINKS TELEPHONE TO SELECTONE OR PUBLIC ADDRESS SYSTEM. dedicated extension

RCDC2 Radio Controlled Device Controller- 2 channel

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

INSTRUCTION MANUAL LCS TX

Radio Micro Force Manual v1.1

KMPS-7 Owners Manual. What s in the box?

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

POWERRISE PLATINUM TECHNOLOGY REMOTE CONTROL GUIDE

Wireless Rain and Wireless Rain/Freeze Sensor

Remote Control Outlets Operating Instructions

Technology. 2.4 GHz Handsender

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

Power Matrix Price List

VZ-WFF. (Wireless Follow Focus) Instruction Manual

Silent Gliss. Control Systems

QUICK PROGRAMMING FOR THERMO SUNIS INDOOR WIREFREE SENSOR

Remote Control Extender AUDIO / VIDEO DEVICES EXTENDING SYSTEM

Users Manual AgCam /EnduraCam TM

Eclipse SC Retractable Shading System Commercial & Residential Applications

Electro-Mech Scoreboard Co. Product Guide

WIRING DIAGRAMS FOR SMART MODELS

WLS-5500 Receiver (KSF & W26)

LSM-BE 7 - Lift System Medium with Box Enclosure

PROTOCOL WISH4 & WISH4-RP

INSTRUCTION BOOK EASILY REMOVEABLE DIES FOR YOUR BINDING NEEDS OD 4012 SHOWN WITH THE OPTIONAL PALM SWITCH FOR THE OD 4012

Workstation Outlets GigaFlex PS6+ Modules Category 6

Industrial Area Crossing Signal System

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

INSTRUCTION MANUAL LKG

PCK43302, PCK MHz Penta series Keyring Remotes with Frequency Hopping

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

REMOTE CONTROL EXTENDER MODEL IR-320 CHO4009 OWNERS MANUAL R1848

Radio Link Starter Kit

2, 4, & 6 Button Application Tool

Wireless Gas Detection System

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Qt 600. Sound Masking - Paging - Music Installation Guide. Purchase date: Install date: MAC Address

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

The Mural Collection II. Advanced All-Digital Decora-Style Dimmers with Preset and Scene Capable Models

05MM-RE03. Remote Control Extender User s Manual

05MM-RE03. Remote Control Extender User s Manual

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

The wireless alternative to expensive cabling...

NV-WA40W. Installation and User Guide

H-ITT ienable (TX3500) manual V1.1

RADIO CONTROL RADIO CONTROL & WIRED... 6 RADIO CONTROL & WIRED & MEDIA CONTROL... 7 MEDIA CONTROL OR IB-BUS-SYSTEM/KNX... 8


On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

Signet 2750 DryLoc ph/orp Sensor Electronics

INSTALLATION INSTRUCTIONS. mitter DL85K. Dinky Link TM Surface Mount Plasma / LCD / LED / CFL Friendly IR Receiver

2573 N.W. 74th Ave. Miami, Florida Phone: (305) /8672 Order Fax: (305)

Straight Isolation - Plug In (171 Series)

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Doc Rev - B. INSTALLATION AND PROGRAMMING INSTRUCTIONS FOR THE ClikCard NARROW BAND RESIDENTIAL GARAGE DOOR RECEIVER

Remote Radio Control. WAVE Push button radio control systems

IS-3000 SERIES INFRARED SCANNER

QUICK PROGRAMMING GUIDE FOR TILT WIREFREE

Transcription:

Wiring Information Blinds & Shades Except Silhouette Pirouette Vignette 3351 Jack Northrop Avenue, Hawthorne, CA 90250-4426 Tel: 310-220-2600 / 800-533-3040 Fax: 310-559-9764 email: sales@smautomatic.com web: www.smautomatic.com 2012 SM Automatic

Basic Switching Control Terminology and Information Guide Low Voltage Modular Switch (recessed wall installation) Available with drapery motors only. A specially designed three button switch, open-stop-close, which allows direction reversal at any point. Low voltage switching connections are made, using RJ-11 modular cable, from the switching port of the motor to a modular wall jack (phone type); then inside the wall to the junction box containing the switch. Power to the motor is supplied by a 9 foot power cord. Hard wired (HW) All motors (except drapery motors and Model 9700) come with a 4 wire, 6 foot pigtail, consisting of a common, two directional wires and a ground. Used for wiring to a powered, SPDT (single-pole, double-throw) 110VAC switch. The motor s pigtail is connected either by hard wiring or by plug/receptacle to an individual junction box. If more than one motor is controlled by a single switch, isolation (parallel) relays are required. Hard wired with Isolation Relays (HW/ISO) This variation of Hard Wiring is used when controlling two or more motors simultaneously from a single SPDT switch. Each motor pigtail (with relay incorporated) is connected either by hard wiring or by plug/receptacle to an individual junction box. The wiring from each junction box is connected from one to the next; with the wiring from the terminal junction box going to the switch. Radio Frequency Wireless Remote Control (SMA-RF) A radio frequency controlled system for most motors (except Model 9700). Transmitters are available to control from 1-24 motors, with individual, group and subgroup operation options. For Models 8000 and 9600, the RF receiver is concealed within the head rail, when ordered with the wireless remote control option. Infrared Wireless Remote Control (SMA-IR) The system is directional, digital coded and has a maximum range of 50 feet. Infrared systems are not subject to possible interference from outside sources, as is sometimes the case with radio frequency controls, but must have line of sight between the transmitter and sensor (sensors are available within or without a mounting case). Transmitters are available to control from 1-24 motors, with individual, group and subgroup operation options. A wide variety of configurations are possible, allowing for either individual or group operation; as well as auxiliary wall switches and control system interfaces. A receiving eye is plugged into the receiver using a modular cable, and takes it s signal from the transmitter.. Radio Frequency Wireless Remote Control (RTS) Radio Technology Somfy, provides a comprehensive method for radio frequency control of motorized systems, with cross platform control system integration. Available both as stand alone, single motor RF control, or as an integrated part of a whole house automated system. Control System Provides an interface with a home theater, multi-room control system, or whole-house automation system. For drapery motors interfacing with a home theater, multi-room control system, or whole-house automation system; two (2) momentary dry contacts (switching contacts with no voltage inputted) are required for open-stop-close (two button) operation. Operation initiates with either the Open or Close contact, and a second action with either contact produces the Stop function. All other motors (except model 9700) use two (2) momentary dry contacts. All motors are fully compatible with control systems by AMX, Crestron Electronics, LiteTouch, Lutron Electronics, Phast, Control4 and Vantage Controls. 2

Electrical/Electronic Control Accessories for Models 5100, 8000, 9600 and 9300 Series Switches S-DEC2 S-DEC1 S-DEC3 Decora style paddle switch (SPDT), three position with center off, and cover plate. Available as maintained or momentary. Colors: white, ivory or almond Decorator toggle switch (SPDT), three position with center off, and cover plate. Available as maintained or momentary. Colors: white, ivory or almond Decora style paddle switch (DPDT), three position with center off, and cover plate. To control two motors simultaneously, without using isolation relays. Available as either maintained or momentary. Color: white S-5 Combination momentary-maintained rocker switch, five position with center off. Used in conjunction with Model 8000. Using ISO relays, 10 motor MAX. Color: white S-DEC5 S-KEY PR TS-HW TS-CSI Decora style, combination momentary-maintained rocker switch, five center off. Used in conjunction with Model 8000. Using ISO relays, 2 motor MAX. Color: white Key switch Plug and receptacle for hard wiring alternative. Consisting of a four wire plug, matching single receptacle and cover plate. Tester switch used typically used for setting Model 9300 series (hard wired) motor limits when assembling COM shades, as well as confirming proper motor operation of Models 9300/9600/8000/5100, (hard wired) when installation site electrical hook up is not available Tester switch used typically used for setting Model 9300 series (with CSI option) motor limits when assembling COM shades, as well as confirming proper motor operation of Models 9300/9600/8000/5100, (hard wired) when installation site electrical hook up is not available. Relays and Interface CSI ISO Control System Interface Electronic (solid state) isolation (parallel) relay for all 110VAC hard wired motors and must be used when controlling multiple motors from a single SPDT switch. Available with or without plastic enclosure. 3

Electrical/Electronic Control Accessories for Models 5100, 8000, 9600 and 9300 Series Wireless Remote Control SMA-RF Radio frequency remote control receiver. Cost is already included in 5100, 9300 and 9600 price charts under the "wireless" heading. SMA-IR Infrared remote control receiver, receiving eye, and modular cable (3 foot) Cost is already included in 5100, 9300 and 9600 price charts under the "wireless" heading. RF/IR-T1 Radio Frequency or Infrared remote control transmitter (controls one motor) RF/IR-T2 Radio Frequency or Infrared remote control transmitter (controls up to 2 motors individually and as a group) RF/IR-T4 Radio Frequency or Infrared remote control transmitter (controls up to 4 motors individually and as a group) RF/IR-T12 Radio Frequency or Infrared remote control transmitter (controls up to 12 motors individually and as a group) RF/IR-T24 Radio Frequency or Infrared remote control transmitter (controls up to 24 motors individually and as a group) IR Keypad Recessed wall mount (single gang), keypad control. Includes built in infrared receiving eye. Available in configurations to control from 1-24 motors individually, as a group or as subgroups. RF Keypad Recessed wall mount (single gang), keypad control. Available in configurations to control from 1-24 motors individually, as a group or as subgroups. Custom configurations (both IR and RF versions) as well as custom labeling is available for an additional cost. RES-2 Infrared receiving eye splitter for 2 motor individual and group control 4

Electrical/Electronic Control Accessories for Models 5100, 8000, 9600 and 9300 Series RTS RTS-RCVR Telis 1 Telis 4 RTS Receiver for Models 5100, 9600 and 8000 (already included in 9300-RTS) One Channel Transmitter Four Channel Transmitter Telis 16 Sixteen Channel Transmitter (Telis 16 is for all motors except 5100, 8000 and 9600) Decoflex 1 One Channel Wireless Wall Switch Color: white or ivory Decoflex 1 One Channel Wireless Wall Switch Color: black Decoflex 2 Two Channel Wireless Wall Switch Color: white or ivory Decoflex 2 Two Channel Wireless Wall Switch Color: black Decoflex 3 Decoflex 3 Three Channel Wireless Wall Switch Color: white or ivory Three Channel Wireless Wall Switch Color: black Decoflex 4 Four Channel Wireless Wall Switch Color: white or ivory Decoflex 4 Four Channel Wireless Wall Switch Color: black Decoflex 5 Five Channel Wireless Wall Switch Color: white or ivory Decoflex 5 Five Channel Wireless Wall Switch Color: black Chronis Sunis Repeater Dry Contact Table Top S Table Top B Table Top W Universal Interface RTS Timer RTS Sun Sensor RTS Repeater (extends signal range) Single Channel Dry Contact Interface Table Top Wirelss Switch Housing (add appropriate Decoflex above) Color: silver Table Top Wirelss Switch Housing (add appropriate Decoflex above) Color: black Table Top Wirelss Switch Housing (add appropriate Decoflex above) Color: white RTS Universal Interface - Converts IR, RS232 or RS485 to RTS (Universal Interface is for all motors except 5100, 8000 and 9600) 5

RTS - Radio Technology Somfy Radio Technology Somfy (RTS) is a secure radio control system for the residential, commercial and hospitality markets. It offers a high performance, reliable and convenient wireless solution for motorization and automation, significantly reducing the wiring requirements. Wireless controls mean fast, easy installation with minimal impact on the building structure. With the exclusive SMA-RTS receiver, the RTS control platform now extends across the entire spectrum of our product line, and is available for every drapery, blind and shade application. Telis 1 Channel Transmitter Telis 5 Channel Transmitter Telis 16 Channel Transmitter DecoFlex 1 Channel Wireless Wall Switch DecoFlex 5 Channel Wireless Wall Switch Chronis Timer Universal Interface Repeater SMA-RTS Drapery Motor Receiver Dry Contact Interface Sunis Sun Sensor 6

Basic Electrical Wiring Information and Diagrams for Models 5100, 8000, 9600 and 9300 Series Hard wiring (HW) All motors come with a 4 wire 18 gauge grounded pigtail. This consists of a neutral, two directional wires, and a ground. This type of wiring is used when the motor is to be controlled by a recessed wall switch. The pigtail is connected by either hard wiring or a plug/ receptacle. A single motor is controlled by an SPDT (single pole, double throw) switch. Two motors can be controlled together by a DPDT (double pole, double throw) switch. When more than two motors are to be controlled by a single switch, isolation (parallel) relays are required for each motor. Neutral Ground Hot Motor Direction 1 Motor Direction 2 To Motor SPDT Switch Neutral Ground Hot Motor Direction 1 Motor Direction 2 SPDT Switch To Motor Hard wiring with Isolation (Parallel) Relays (HW/ISO) This variation of hard wiring is used when controlling two or more motors simultaneously from a single SPDT switch. Each motor s pigtail (with relay incorporated) is connected either by hard wiring or by plug/receptacle to an individual junction box. The wiring from each junction box is connected from one to the next; with the wiring from the terminal junction box being connected to the switch. Ten motors are the maximum to be operated by one, 15 amp switch. SMA-RF Wireless Remote Control A radio frequency system which is controlled by a hand-held transmitter. It is omnidirectional, digital coded, and has a maximum range of 100. Transmitters are available to control from 1-24 motors, with individual, group and subgroup operation options. Standard Hard wiring Motor Motor Motor Relay Relay Relay Junction Box Junction Box Hard wiring with optional plug/receptacle Junction Box Direction 1 Direction 2 Neutral Ground SPDT Switch RTS-RF Wireless Remote Control Radio Technology Somfy, provides a comprehensive method for radio frequency control of motorized systems, with cross platform control system integration. Available both as stand alone, single motor RF control, or as an integrated part of a whole house automated system. Electrical wiring required for either SMA-RF, SMA-IR, or RTS wireless remote control, is a standard 110 VAC duplex electrical outlet. SMA-IR Wireless Remote Control The system is directional, digital coded and has a maximum range of 50 feet. Infrared systems are not subject to possible interference from outside sources, as is sometimes the case with radio frequency controls, but must have line of sight between the transmitter and sensor. Transmitters are available to control from 1-24 motors, with individual, group and subgroup operation options. Control System Interface When interfacing with a home theater, multi-room control system, or whole-house automation system; two (2) momentary dry contacts (switching contacts with no voltage inputted) are required. 7

Switch and Transmitter Options for Models 5100, 8000, 9600 and 9300 Series Wall Switches S-DEC2 Almond S-DEC1 Ivory S-DEC3 White S-DEC5 Radio Frequency and Infrared Remote Control Please see page 6 for RTS Control Telis Transmitters and DecoFlex wireless switches. Custom transmitter and keypad configurations are available by special order RF/IR-T1 RF/IR-T2 RF/IR-T4 RF/IR-T12 Radio Frequency and Infrared Remote Control Keypads RF-K1 / IR-K1 RF-K3 / IR-K3 RF-K4 / IR-K4 RF-K6 / IR-K6 RF-12 / IR-K12 8

Electrical/Electronic Control and Wiring Legend S-DEC2 Decora Paddle Switch Radio Frequency Receiver S-DEC1 Decorator Toggle Switch Infrared Receiver S-DEC5 Decora 5 Position Switch (for Model 8000 only) IR Receiving Eye Standard / in case 1.75" 2.1" Optional without case.375".5" Modular Wall Jack (RJ-11) Control System Interface Modular Wall Jack Double (RJ-11) Standard 110 volt Duplex Outlet OPEN CLOSE OPEN CLOSE 1 ALL 2 8 3 9 4 10 5 11 Infrared or Radio Frequency Receiver Keypad 6 12 7 STOP Modular Cable (four conductor: 4/26) Automation Control System (supplied by others) In-wall Modular Cable (four conductor: 4/26) (supplied by others) Automation Control System User Interface (supplied by others) 9

Electrical Wiring Diagrams for Models 5100, 8000, 9600 and 9300 Series A. Hard wired Individual SPDT Control Optional Hard wiring Plug and Receptacle (PR) B. Hard wired Group Control using Isolation (parallel) relays C. Individual Radio Frequency Remote Control D. Individual Radio Frequency Remote Control with SPDT switch E. Individual Infrared Remote Control F. Individual Infrared Remote Control with SPDT switch Remote control receivers, relays and low voltage interfaces, are located inside the head rails on models 9600 and 8000; and are external on models 5100 and 9300 series motors. 10

Electrical Wiring Diagrams for Models 5100, 8000, 9600 and 9300 Series G. Automation Control System H. Automation Control System with SPDT Switch I. Automation Control System with Infrared (or Radio Frequency) Remote Control J. Automation Control System with Infrared (or Radio Frequency) Remote Control and SPDT Switch K. Modular Wiring for Automation Control System Modular RJ-11 Plug Connection Yellow - Down Direction Green - Common (common to Yellow) Red - Up Direction Black - Common (common to Red) 2-Green 3-Red 1-Yellow 4-Black Tab Side Modular Wall Jack Black Red Green Yellow SMA-RF and SMA-IR remote control receivers, relays and low voltage interfaces, are located inside the head rails on models 9600 and 8000; and are external on models 5100 and 9300 series motors (except 9300-RTS). 11

OPEN CLOSE OPEN CLOSE 1 2 3 4 5 6 7 ALL 8 9 10 11 12 STOP Electrical Wiring Diagrams for Models 5100, 8000, 9600 and 9300 Series L. Individual and Group Infrared Remote Control with Keypad Remote control receivers, relays and low voltage interfaces, are located inside the head rails on models 9600 and 8000; and are external on models 5100 and 9300 series motors. 12

Electrical Wiring Diagrams for Models 5100, 8000, 9600 and 9300 Series M. Control System Interfaces Installed within a Centralized Control Panel 110VAC Line in CSIs Installed in Control Panel Low Voltage Cable 13

Electrical Wiring Diagrams for Models 5100, 8000, 9600 and 9300 Series N. Individual and Group Infrared Remote Control with Automation Control System O. Model 9300 series motor and Drapery Motor, with Automation Control System and SPDT Switch Important Information Regarding Radio Frequency Interference All radio frequency (RF) wireless remote control systems are subject to radio wave interference. When present, RF interference may be constant or intermittent. According to FCC regulation, equipment used for RF wireless remote controlled window treatments, must follow these guidelines: Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference that may be received, including interference that may cause undesired operation. 14

Electrical Wiring Information and Diagrams - A Comparative Guide for Control Systems Roman and roller shades When interfacing with a home theater, multi-room control system, or whole-house automation system; two (2) momentary dry contacts are required. Operation initiates with either the Open or Close contact, and a second action with either contact produces the Stop function. Cellular shades When interfacing with a home theater, multi-room control system, or wholehouse automation system; two (2) momentary dry contacts are required. Operation initiates with either the Open or Close contact, and a second action with either contact produces the Stop function. Horizontal blinds When interfacing with a home theater, multi-room control system, or wholehouse automation system; two (2) SETS of momentary dry contacts are required. One set of contacts for tilting function must have timed contacts of less than 1.5 seconds. The second set of contacts for lifting function must have a timed contact of more than 1.5 seconds. Modular Wiring for Shades and Blinds Connecting to an Automation Control System Modular RJ-11 Plug Connection 1-Yellow 2-Green 3-Red 4-Black Black Red Green Yellow Yellow - Down Direction Green - Common (common to Yellow) Red - Up Direction Black - Common (common to Red) Tab Side Modular Wall Jack 15