Fly Elise-ng Grasstrook HG Eindhoven The Netherlands Web: elise-ng.net Tel: +31 (0)

Similar documents
Edge Blender Controller

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

All projected images must be visible from the camera point of view. The content exists in 2D - an "unwrapped" view of the content in the aspect ratio

ISCapture User Guide. advanced CCD imaging. Opticstar

How to combine images in Photoshop

KoPa Scanner. User's Manual A99. Ver 1.0. SHENZHEN OSTEC OPTO-ELECTRONIC TECHNOLOGY CO.,LTD.

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS

Contents Technical background II. RUMBA technical specifications III. Hardware connection IV. Set-up of the instrument Laboratory set-up

QImaging. All rights reserved. QUICK START GUIDE

DAVID SLS-1. Getting Started Guide

NanEye in Awaiba Viewer

Mighty Scope 5M. Instruction Manual. aveninc.com

User Guide of ISCapture

Motic Live Imaging Module. Windows OS User Manual

Movie 7. Merge to HDR Pro

ID Photo Processor. Batch photo processing. User Guide

We recommend downloading the latest core installer for our software from our website. This can be found at:

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

DigiScope II v3 TM Aperture Scope User s Manual

1 VIOSO CALIBRATOR manual english VIOSO CALIBRATOR. Autocalibration Software. english version

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

G-700 multiple Channel 4K Curve Edge Blending Processor

Digital Microscope. User Manual

CobraCam USB III Portable Inspection Camera with USB Interface Instruction Manual

ImagesPlus Basic Interface Operation

Optika ISview. Image acquisition and processing software. Instruction Manual

User Manual for VIOSO BlackBox 2.0

GXCapture 8.1 Instruction Manual

Adobe Photoshop. Levels

CONTENTS. Chapter I Introduction Package Includes Appearance System Requirements... 1

Extending the Dynamic Range of Film

HP Advanced Profiling Solution Quick Start Guide

Photoshop Elements Hints by Steve Miller

Basic Tutorials Series: Import A Photograph. RenoWorks Support Team Document #HWPRO0003

ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

Reference Guide. Color Image Scanner

Input of Precise Geometric Data

G-302 Dual Projector Edge Blender Quick User Guide

CALIBRATION MANUAL. Version Author: Robbie Dowling Lloyd Laney

inphoto ID Canon camera control software Automatic ID photography User Guide

Geometric Functions. The color channel toolbar buttons are disabled.

1. Setup Output mode. 2. Using a Fixed tile size

Apple Photos Quick Start Guide

Advanced Diploma in. Photoshop. Summary Notes

Marshall Electronics. Full-HD (3G/HD-SDI) Mini-Broadcast POV Cameras. CV343, CV502, CV345, CV505 models. Operation Manual

Digital Portable Overhead Document Camera LV-1010

ToupSky Cameras Quick-guide

Micro-Image Capture 8 Installation Instructions & User Guide

Manual. ios App. Ver2.2. v Mall Drive, Commack, NY (P) (F)

Digital Imaging - Photoshop

EinScan-SE. Desktop 3D Scanner. User Manual

REV.C. SmartScope 5M

VSCO FILM 01 MANUAL FOR: LIGHTROOM 4 & ADOBE CAMERA RAW 7

Photoshop CC: Essentials

MEASUREMENT CAMERA USER GUIDE

PHOTOSHOP LIGHTROOM 5

User Manual Of Einscan-Pro. Brief Introduction

Visioneer OneTouch 7300 Scanner FOR USB CONNECTION. Installation Guide

PC System Requirement For Dual Microscope

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

Stacking Correction Tool

μscope Microscopy Software

INSTRUCTION MANUAL MM-A209

Operation Manual Full-HD Miniature POV Camera

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

AreaSketch Pro Overview for ClickForms Users

Movie Merchandising. Movie Poster. Open the Poster Background.psd file. Open the Cloud.jpg file.

Installation & User Manual Micro-Image Capture 7

SCD-0017 Firegrab Documentation

ScanGear CS-U 6.0. for CanoScan D646U Color Scanner. User s Guide

CHROMACAL User Guide (v 1.1) User Guide

Leica DMi8A Quick Guide

Getting Started. with Easy Blue Print

Color Management User Guide

Veterinary Digital X-Ray System Quick Start Guide

Operating Rausch ScanCam within POSM.

Alignment of the camera

Sense. 3D scanning application for Intel RealSense 3D Cameras. Capture your world in 3D. User Guide. Original Instructions

Enhanced Eyes. Here's the image I'll be working with (glamour eyes photo from Shutterstock): Here's what the eyes will look like when we're done:

USB Line Camera 8M. Coptonix GmbH

Stacking Correction Tool

FEATURES Industry windows paperless solutions High speed portable document scanner is well-suited for a wide variety of Window industry

What is real? What is art?

Reference and User Manual May, 2015 revision - 3

M a c i n t o s h. Canon Plug-in Module CS-U 3.9 for CanoScan D660U Color Image Scanner. User's Guide

Minolta Scanner Plugin

SPECTRALIS Training Guide

Manual Stitching of Multiple Images to Produce a Panorama

HD-01e High Definition Easy Scope

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Chlorophyll Fluorescence Imaging System

ScanGear CS-U 5.6. for CanoScan FB1210U Color Scanner. User s Guide

Before you start, make sure that you have a properly calibrated system to obtain high-quality images.

Magic Wand Portable Scanner with Auto-Feed Dock. PDSDK-ST470-VP-BX2 User Manual

Introduction to: Microsoft Photo Story 3. for Windows. Brevard County, Florida

Watec USB Camera. User s Manual

Transcription:

Fly Elise-ng Grasstrook 24 5658HG Eindhoven The Netherlands Web: http://fly.elise-ng.net Email: info@elise elise-ng.net Tel: +31 (0)40 7114293 Fly Elise-ng Immersive Calibration PRO Step-By Single Camera Copyright 2012/2017 Fly Elise-ng, All Rights Reserved 1

1 Introduction... 3 2 Configure the PC displays... 6 3 Start and configure the projectors setup... 7 4 Camera selection... 10 5 Camera position and camera properties... 11 6 Camera masking... 15 7 Projector scanning configuration... 17 8 Warp setup... 20 9 Blend setup... 22 10 Load and use calibration results... 24 2

1 Introduction This is a 10 minutes step-by-step guide for setting-up a seamless immersive projection using any type of continuous projection screen surface with one or more overlapping projectors. The calibration produces perfectly aligned and geometrically correct image by taking into account the projector positions and the screen surface. At the end of the calibration, Immersive Calibration PRO exports the warping and blending configuration that can be loaded and used in Immersive Display PRO for warping and blending the PC output image to get one seamless display. For this calibration one web cam is needed. The camera needs to be positioned so that the camera can capture and see the complete projection screen including the projectors images on the screen. Because of this, this Single Camera calibration method is most suitable for calibration of multi-projector setups where the angle (field of view) of the projection screen does not exceed 160 degrees and the complete screen can be seed in the camera view. The Single Camera calibration is usable for creating: - Game setups with single game camera view - Video shows and presentations - Windows 7/8/10 Desktop presentations - Power Point and other interactive presentations - Touch display walls and interactive floors. - Etc For the purpose of this step-by-step guide we will use a cylindrical projection screen with the following parameters: horizontal angle 120 degrees, height 1.5 meters and radius 2.0 meters (diameter 40 meters). The 3 BenQ 1024x768 projectors are positioned in such a way that the complete projection screen is covered by a projection images from projectors and that the projector images overlap by about 15%. A Logitech Webcam PRO 9000 HD camera is positioned in front of the projection screen and can capture the complete screen. 3

Note: For the best calibration results with this Single Camera calibration method it is important that the projectors are positioned in such a way that the complete projector image overshoots the screen edges. This Single Camera calibration method does not require the projection screen edges to be marked. During the calibration process the software will make sure that the projected images is combined as one seamless image and this image is projected on the projection screen as one single wallpaper. 4

Before calibration After calibration 5

2 Configure the PC displays We will use single PC to perform the calibration: The PC has at least 3 outputs connected to the 3 projectors. The displays must be configured as one wide display (3x1) created either by using Matrox TripleHead 2 Go or ATI Display Group or NVidia SLI Surround or NVidia Mosaic mode. Desktop and all other software will be stretched on this large extended display. 3x1 grouped display configuration 6

3 Start and configure the projectors setup Use the Single.exe program to start Single Camera calibration. A window will open to select the projectors configuration on the detected PC displays. Because we have one large display connected to 3 projectors, we can set the projector configuration to 3x1. The projectors identity images will be shown on the display and the projectors. Right-click on the display that is connected to the projectors and select projector configuration 3x1 from the popup menu. 7

The displays will be configured in 3x1 mode and the projector numbers will be shown on the projectors. 8

Press the Select camera button on the lower right part of the window to go to the camera selection window 9

4 Camera selection In the camera selection window all the connected webcams on the PC will be listed. If the camera is not listed, make sure that the camera is plugged in the USB port or try another USB port and restart the software. Select the camera to be used for calibration and select the highest resolution available from the camera. Although the software can be successfully used with standard definition webcams, it is highly recommended to use HD web cam. The cameras from Logitech and Microsoft are very good HD webcams. Press the Camera position button on the lower right part of the window to go to the camera position and preview window. 10

5 Camera position and camera properties p Position the camera so that the camera can capture the complete projection screen and the projection screens occupies a large portion of the camera image. Note: The camera has to be fixes and should not be moved during the rest of the calibration. For successful calibration it is important that all automatic camera features (auto-focus, auto-zoom, white balance, etc.) have to be turned off. Press the camera properties button to open the camera properties widow. This window is provided by the camera drivers and can look differently for different cameras. 11

No Auto focus No Auto Gain and Auto White Balance 12

Use the camera controls to adjust the camera image for the best projector scanning and calibration results. The primary control of the camera image is the Exposure control. Use the Exposure to get the most natural looking camera image. The camera image should look natural and should not be too dark, too bright or saturated. The black and darker colors and the white and brighter colors should utilize the complete camera colors range. In order to help and facilitate the adjustments of the camera properties, the software comes with a tool called Histogram to evaluate and calculate the used camera dynamic range. Select the Histogram button and press on the calculate button. The software will project a number of patterns on the projection screen and will calculate the range between the dark colors and the bright colors as well as the middle distance. 13

Camera histogram The camera histogram shows two peeks. The left peek is for the dark colors and the right peek is for the bright colors. Camera histogram peeks Use the camera properties (primarily the Exposure) to change the camera properties in such a way that the two peeks are as far as possible and that there orange line lies in the middle between those peeks. Note: Make sure that you recalculate the Histogram each time the camera parameters have been changed. Press the Camera mask button on the lower right part of the window to go to the camera masking window 14

6 Camera masking The camera masking is necessary to ensure that the calibration process will only focus on scanning of the projectors and calibrating of the screen projection surface. Using the masking grid points ensure that the grid mask is aligned with the edges of the projection screen. Use the grid properties function to add or remove grid control along the horizontal or vertical edges of the mask grid or to reset the masking grid. Once the masking grid is aligned with the screen it can be saved to a file and used later for a new calibration or recalibration. 15

Aligned masking grid Press the Configure projector1 button on the lower right part of the window to go to the projectors scanning configuration window. 16

7 Projector scanning configuration In the projector scanning configuration configures the size and the number of the white circles that will be used for scanning the projectors and calculating the calibration. Projector scanning configuration This can be configured for a single projector or for the all projectors at once. The default values for Circle size, Distance and Max ratio should be good to successful projector scanning. Press the Recognize circles button to pre-scan the projectors and recognize the while circles. After the circles recognition, the recognized circles will be marked with green color and the not recognized circles will be marked with red color. 17

Use the Circle size, Distance and Max ratio to increase or decrease the number and the size of the circles to ensure that as much as possible whole circles are recognized and marked as green. If there are still unrecognized red circles the software will reconstruct them during the scanning. Press the Configure projector2 button on the lower right part of the window to go to the projectors scanning configuration window for the next projector. Repeat the same steps for all projectors and press on the Scan projectors button to start the scanning and calibration process. After the calibration is finished the software will create a combined rectangular projector image with minimal size to fit the screen. 18

Finished calibration 19

8 Warp setup In the warp setup window use the warping grid to map the combined projector image on the projection screen. When the masking grid has been used to mask the projection scanning, the masking grid can be used to automatically map the projection image to the screen. Press the Take mask button to take the mask grid and use it for screen mapping. When the combined projection image is mapped to the projection screen use the grid control points to fine tune the mapping. Add additional control points in horizontal or vertical direction to get more control on the mapping. Use the mouse of keyboard to move the grid control points. 20

The projection screen will show the combined warped and blended test image. Press the Blend setup button on the lower right part of the window to go to the blending configuration window. 21

9 Blend setup In the blend setup window the soft-edge blending parameters can be adjusted to fine tune soft-edge blending regions and to make sure the images from multiple projectors are perfectly blended. The default blending parameters have been chosen to fit most of the projectors and projection screen. However, if the overlapped regions after the scanning are brighter or darker, it is only needed to use slightly change the Gamma parameters in order to achieve the perfect blending. The Gain and the Slope parameters can be used in more advanced blending configurations. This is the last step in the automatic multi-projector calibration. The output of the projectors is warped and edge-blended so that when the projectors project on the projection screen they will produce one single projected image. 22

Projected images from the projectors Projection on the screen Press the Save config button on the lower right part of the window save the calibration results as *.procalib file that can be loaded in Immersive Display PRO. Note: If running on Windows 8 or higher, make sure that you save the *.procalib file in the Immersive Display PRO installation folder (<Program Files>/Immersive Display PRO/) to ensure that the desktop warping will be able to find the saved file. 23

10 Load and use calibration results Start Immersive Display PRO, and click on the display that has been used to calibrate. Select External calibration and select the just saved *.procalib file. Press the Save button and enabled the desktop warping. The complete windows desktop will be warped and blended on the projection screen. All applications started on the desktop will be automatically edge-blended. 24

Windows desktop warping Movie player 25

Racing game 26