Fisher 4200 Series Electronic Position Transmitters

Similar documents
Fisher 646 Electro-Pneumatic Transducers

Fisher 646 Electro Pneumatic Transducer

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Fisher LCP100 Local Control Panel

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IP26 Series Current to Pneumatic Converter

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Rosemount 148 Temperature Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 148 Temperature Transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

All TXI7850 products are ROHS compliant.

Range Spring, Bias Spring, and Spring Retainer/ Spacer Selection for Fisher 3570 Pneumatic Valve Positioners

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Single-Channel Safety Barriers Series 9001

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

CTE7000 Series Miniature pressure transmitters

Positioner with HART Communication Type 3780

Rosemount 148 Temperature Transmitter

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Head mounted Temperature Transmitter TF02/TF02-Ex

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Kotron Model 82 CE RF Level Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 148 Temperature Transmitter

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

LA-5000 SERIES LINEAR VALVE ACTUATORS

Operating Principles

Spring Return DuraDrive Proportional Actuator

Isolators A3/1. Vibration Transducer Supply Unit Series

Pressure transmitter AKS 32 and AKS 33

Two-Wire Programmable Transmitter for:

Non-Spring Return DuraDrive Modulating Actuator

The Rosemount 848T Wireless Temperature Transmitter

Customer Drawings Product Selection

Loop Powered Indicator

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

CTE8000 Series OEM pressure transmitters for industrial media

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Rosemount 248 Wireless Temperature Transmitter

Accutech GP10. Wireless gauge pressure field unit

Rosemount 702 Discrete Input Transmitter

Rosemount 3101, 3102, and 3105

Analog Universal Module HART for Zone 2 Series 9468/33

3500/64M Dynamic Pressure Monitor

Rosemount 248 Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

z47524 PXI Quad SPDT RF Changeover Switch Module

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol

Alphaline Temperature Transmitters

Accutech FL10. Wireless float level field unit

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

High Temperature Velocity and Acceleration Sensor

A6500-UM Universal Measurement Card

CB Scheme UL508 UL ATEX II3G

Echotel Model 910 Ultrasonic Level Switch

SALES SERVICE +358 (0)

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Process display RIA 261

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

XMU+ Environmental, Safety and Specifications

SMART TEMPERATURE TRANSMITTERS. smar

High precision measurement system for current and voltage IHC-A/B-RM01/03

Level Limit Switch nivotester FTL 325 P

JM Enclosure Dimensions (in mm)

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

TIY Programmable, Isolated Thermocouple Transmitter combines

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Accutech AM20. Wireless acoustic monitor field unit

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Vert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Echotel Model 910 Ultrasonic Level Switch

Digital Input Output Module for Zone 2 Series 9470/33

z488xx RF Switches/Multiplexers PXI

FLEX Ex Power Supplies

Rosemount 702 Wireless Discrete Transmitter

Temperature transmitter itemp RTD DIN rail TMT 127

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Isolators A3/1.

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Mass and Volume Flow Transmitter

Inductive sensor slot-type SI2-K08-AP7

T22. Torque transducer. Special features. Data sheet

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

LST100 Ultrasonic level transmitter for upstream oil and gas

Kotron Sentinel Model 804 RF Level Transmitter

Transcription:

Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic and mechanical expertise in a versatile, accurate instrument that senses the position of a device, and sends a standard (4-20 ma) output signal to an indicating device. The instrument is available as a transmitter with integral high and low electronic travel limit alarms, as a transmitter only, or with electronic travel limit alarms only. The instrument can sense the position of rotary or sliding-stem valves, vents, dampers or other devices. When the instrument is mounted, a potentiometer shaft is mechanically connected to the device to sense mechanical motion. For a standard instrument, a single potentiometer is provided for position input or an optional dual element potentiometer is available to allow independent electrical operation of the transmitter and alarm circuits. The instrument has standard, or long-stroke (see figure 5), capabilities for sliding-stem actuator applications. For long-stroke applications, a multi-turn potentiometer attached to a travel transducer assembly is used to sense linear motion of the actuator stem or other devices. The instrument with standard capabilities can also be used on quarter-turn actuators. For instruments equipped with electronic travel limit alarms, individual electronic high and low alarm circuits drive separate high and low alarm SPDT relays. The user adjusts the trip point and deadband of the high and low alarms to the desired travel limits. When the sense potentiometer voltage is higher than the high trip point, the electronic high alarm circuit de-energizes the high alarm relay. When the sense potentiometer voltage is lower than the low trip point, the low alarm circuit de-energizes the low alarm relay. The low trip point may be offset from the high trip point by as little as 5% of the remaining span. In the event of a power loss to the alarm circuits, both alarms are tripped (both relays are de-energized). This indicates a system failure because the actuator cannot be physically at both travel limits simultaneously. The relay contacts are isolated from the transmitter and alarm circuits. W9274 W966/IL W4271 1/IL Figure 1. Fisher 4200 Series Transmitter Figure 2. Fisher 4200 Series Transmitter on a Control Valve D200357012 www.fisher.com

4200 Series Transmitters Product Bulletin Specifications Available Configurations See table 1 Input Signal Source Standard single potentiometer, or optional dual potentiometer is the source for the transmitter and travel limit alarm circuit inputs. Refer to table 2 for zero and span limits. Transmitter Output Signal Range: 4-20 ma DC transmitter output Load Impedance: See figure 3. Output Current Limit: 30 ma DC maximum Travel Limit Alarms Number of Possible Alarms: Two or none. Each SPDT relay indicates limit and fault conditions as follows: Operating Condition Travel within limits Travel beyond limits Relay Coil State NC Contact State NO Contact State energized open closed de-energized closed open Power loss de-energized closed open NC Normally closed. Contacts are closed when relay is de-energized NO Normally open. Contacts are open when relay is de-energized. Power Supply Requirements See table 3 Recommended Power Supply +24 volts DC nominal Reference Accuracy ±1% of output span. Includes combined effects of hysteresis, linearity, and deadband Repeatability: ±0.25% of span Operating Influences Ambient Temperature: For a 56 C (100 F) change in normal operating conditions, maximum zero shift is ±0.5%, and the maximum span shift is ±0.75% of span Power Supply: Output signal changes less than ±0.1% when operating terminal voltage varies between 11 and 30 volts DC Electromagnetic Compatibility for 4211 and 4221 Meets EN 61326-1 (First Edition) Immunity Industrial locations per Table 2 of the EN 61326-1 standard. Performance is shown in table 4 below. Emissions Class A ISM equipment rating: Group 1, Class A Travel Limit Alarm Relays Type: Two single-pole, double-throw relays Contacts: 1 Form C, silver-nickel alloy with gold overlay Service Rating: The relay rating is 5 amperes at either 30 volts DC or 120 volts AC (resistive load). Life Expectancy: 100,000 operations at rated load, or 50,000 operations at a typical in-rush current of 10 amperes with a 120 volt AC lamp or motor load Operating Conditions Condition Ambient Temperature Ambient Relative Humidity Normal and Operative Limits 40 to 71 C ( 40 to 160 F) Transportation and Storage Limits 50 to 80 C ( 60 to 180 F) Normal Reference 25 C (77 F) 10 to 95% 10 to 95% 40% Construction Materials Transmitter Housing and Covers: Aluminum Alloy O-Rings: Nitrile Mounting Hardware: Steel Pipe Plug: Nickel coated steel Cable: Nylon-coated stainless steel (long stroke only) Mounting The instrument can mount on the actuator of sliding-stem or rotary valves (refer to figure 5), or it can be used for other applications (continued) 2

Product Bulletin Specifications (continued) Electrical Classification Intrinsic Safety, Explosion proof, Dust-Ignition proof, APPROVED Intrinsic Safety, Explosion proof, Dust-Ignition proof, Non-Incendive ATE Intrinsic Safety, Type n, Dust Refer to tables 5, 6, and 7 for additional information. Housing 4200 Series Transmitters NEMA 4; CSA Enclosure 4; IP66 Approximate Weight Transmitter Without Mounting Bracket: 1.8 kg (4 pounds) Options Long-stroke applications: 12 or 24 inch travel NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 Process Instrument Terminology. Table 1. Available Configurations TYPE NUMBER 4210 4211 4212 4215 4220 4221 4222 TRANSMITTER 1. See table 2 for zero and span limits. TRAVEL LIMIT ALARMS TRAVEL Standard Stroke Up to 105 mm (1) (Up to 4.125 Inches) Long Stroke Up to 610 mm (1) (Up to 24 Inches) DUAL POTENTIOMETER Table 2. Zero and Span Limits (1) TYPE NUMBER DEGREES OF POTENTIOMETER ROTATION Zero Span Position LINKAGE CONNECTION (2) mm INCHES Zero Span Zero Span Span Min. Max. Position Min. Max. Position Min. Max. 4210 1 0 to 51 8 51 0 to 2 0.315 2 4211 0 to 90 15 90 4212 2 0 to 105 17 105 0 to 4.125 0.670 4.125 4215 4220 12-inch Transducer 0 to 305 105 305 0 to 12 4.125 12 4221 0 to 884 150 884 4222 24-inch Transducer 0 to 610 305 610 0 to 24 12 24 1. Zero position is the range of values over which the transmitter zero can be adjusted. Span is the range of shaft rotation or stem travel the transmitter span can be adjusted. For example, a zero position of 45 degrees and a span of 15 degrees means the transmitter output is 4 ma DC after 45 degrees of shaft rotation. The output then increases from 4 ma DC to 20 ma DC as the shaft rotates from 45 to 60 degrees. 2. Refer to figure 6 for location of connections. 3

4200 Series Transmitters Product Bulletin Table 3. Power Supply Requirements and Wiring Connections TRANSMITTER TERMINAL FIELD WIRING CONNECTIONS VOLTAGE (VDC) CURRENT REQUIRED (MA) Min Max Supply Wire (1) Signal Wire (2) Relay Return Wire (3) Transmitter Only 11 30 20 max. Transmitter with Travel Limit Alarms 20 30 80 max. Travel Limit Alarms without Transmitter 20 30 50 max. indicates this connection required. 1. Supply wire provides power supply positive connection for electronic circuits and relay coils (in instruments with travel limit alarms). 2. Signal wire provides connection for device receiving 4 to 20 ma transmitter signal. 3. Relay return wire provides separate return wire for relay coil currents. To reduce field wiring requirements from 4 to 3 wires, the transmitter and alarm circuits share the positive supply wire. A separate return wire is required to isolate relay coil currents from the 4-20 ma transmitter signal. Features High Accuracy A precision film-element potentiometer in the standard unit and a precision multi-turn wirewound potentiometer in the long-stroke unit provide exceptional linearity by matching the span of the sense element to the application. Application Versatility This instrument may be used with sliding-stem or rotary valves as well as with other mechanical devices such as furnace dampers or louvers. LOAD IMPEDANCE (OHMS) 1000 750 650 500 250 0 0 10 20 30 11 24 A6765/IL POWER SUPPLY VOLTAGE (VOLTS DC) OPERATING REGION MAIMUM TRANSMITTER TERMINAL VOLTAGE NOMINAL SUPPLY VOLTAGE MINIMUM TRANSMITTER TERMINAL VOLTAGE Electronic Travel Limit Alarms To eliminate the need for externally mounted mechanical limit switches, instruments with travel limit alarms incorporate comparator circuits that monitor the sense potentiometer voltage output. Adjustable Deadband Electronic travel limit alarms have an adjustable deadband up to 10 percent of the maximum span. Compact Design The instrument, even with travel limit alarms, uses little space when mounted, allowing room for additional devices. Figure 3. Transmitter Load Limitations Durable Construction A rugged housing and a corrosion-resistant coating on the printed wiring board help protect the instrument from harsh environments. Simple Circuitry A simple hybrid electronic design combines the best qualities of discrete components and integrated circuits for improved reliability and performance. 4

Product Bulletin 4200 Series Transmitters PRINTED WIRING BOARD RELAY NUMBER 1 TERMINAL BLOCK NUMBER 1 FIELD PRINTED WIRING BOARD TERMINAL BLOCK NUMBER 3 TERMINAL BLOCK NUMBER 1 W9275 TERMINAL BLOCK NUMBER 2 W4675-1/il RELAY NUMBER 2 TRANSMITTER COMPARTMENT FIELD WIRING COMPARTMENT Figure 4. Fisher 4210 Transmitter Details Easy Maintenance The simple design of the transmitter and alarms allows easy maintenance. The high reliability of the instrument requires minimum spare parts inventory. Moisture Resistant The field wiring compartment is isolated from the electronic compartment. This protects the electronic circuits from any moisture brought into the housing via the field wiring ports. Field Reversible Action The output is easily reversed in the field simply by switching two potentiometer leads on the printed wiring board. Electromagnetic Interference (EMI) Filters Filters between the electronic compartment and the field wiring compartment of the housing help provide protection against electromagnetic interference. Applications Standard Position Transmitter Sliding-Stem Valve In typical valve applications, the transmitter is mounted on the actuator as shown in figure 1. Two linkage configurations sense up to 51 mm (2 inches) or up to 105 mm (4.125 inches) of stem travel. The linkages incorporate mechanical gearing to linearize the transformation from linear motion to rotational. To reduce the possibility of physical damage if the linkage should slip, the potentiometer has no physical stops. Zero and span can be adjusted as follows: Zero Between 0 and 51 mm (2 inches) of travel, or between 0 and 105 mm (4.125 inches) of travel. Span Between 9 mm (0.3 inch) minimum span and 51 mm (2 inches) maximum span, or between 17 mm (0.6 inch) minimum span and 105 mm (4.125 inches) maximum span. Rotary-Shaft Valve In typical valve applications, the transmitter is mounted on the actuator as shown in figure 2. A coupling connects the hub of the actuator to the potentiometer shaft. To reduce the possibility of physical damage if the coupling should slip, the potentiometer has no physical stops. Zero and span can be adjusted as follows: Zero Between 0 and 90 degrees of shaft rotation. Span Between 15 and 90 degrees of shaft rotation. Other Devices The transmitter is mounted such that the potentiometer shaft or linkage aligns with the motion of the device. The motion of the device should not exceed the zero and span input signal limits in degrees of rotation. 5

4200 Series Transmitters Product Bulletin PORT 1/2 NPT (2 PLACES) TRANSMITTER COMPARTMENT 102 (4.00) FIELD WIRING COMPARTMENT 159 (6.25) 102 (4.00) CAP (2 PLACES) 6 (0.25) DIA. 35 (1.38) 67 (2.62) END VIEW 21 (0.81) 75 (3.00) ALLOW 254 mm (10 INCHES) FOR MAINTENANCE (2 PLACES) 67 (2.62) POTENTIOMETER SHAFT SIDE VIEW 51 (2.00) 5/16-18UNC 13 DEEP (0.53) 51 (2.00) 19A7968 E B1910 3*A / IL BOTTOM VIEW Figure 5. Dimensions mm (INCH) Long-Stroke Position Transmitter Long-Stroke Sliding-Stem Valve The transmitter is mounted on the actuator as shown in figure 5. The travel transducer assembly can sense from a 105 mm (4.125 inch) minimum to a 610 mm (24 inch) maximum stem travel. The sensing element is a multi-turn potentiometer with physical stops. Two travel transducer sizes are available for long stroke applications. Zero Between 0 and 305 mm (12 inches) for the small transducer. Between 0 and 610 mm (24 inches) for the large transducer. Span Between 105 mm (4.125 inches) minimum and 305 mm (12 inches) maximum for the small transducer. Between 305 mm (12 inches) minimum and 610 mm (24 inches) maximum for the large transducer. 6

Product Bulletin 4200 Series Transmitters Other Devices The transmitter is mounted such that the travel transducer aligns with the motion of the device to allow straight retraction of the cable to the transducer. The motion of the device should not exceed the zero and span limits in mm (inches). 3. Valve body design. 4. Other applications Installation Field wiring is inserted into one of the ports and connected to the terminal blocks mounted on the printed wiring board in the field wiring compartment. The instrument with transmitter circuits and travel limit alarms, and the instrument with alarms only (no transmitter circuits), use terminal blocks numbered 1, 2, and 3 (see figure 4) on the printed wiring board. These terminal blocks are accessible when the field wiring compartment cover is removed. The instrument with transmitter circuits only (no alarms) uses a barrier strip mounted in the field wiring compartment without the printed wiring board. Dimensions of the transmitter housing are shown in figure 5. Mounting dimensions are shown in figure 6. Ordering Information When ordering, specify: 1. Transmitter type number. 2. Actuator type, size, and length of stroke. (Note: For Fisher 585CLS Series actuators, specify yoke boss and cylinder size.) Note Contact your Emerson Process Management sales office for assistance in determining the type and style of linkage and mounting hardware required for the application. Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end-user. 7

4200 Series Transmitters Product Bulletin 48 (1.88) 108 (4.25) 86 (3.40) 271 (10.69) 204 (8.00) ACTUATOR HOUSING 51 (2.00) CONNECTION NUMBER 1 CONNECTION NUMBER 2 TYPICAL MOUNTING BRACKET DIMENSIONS FOR SLIDING-STEM ACTUATORS TYPICAL MOUNTING BRACKET DIMENSIONS FOR ROTARY-SHAFT ACTUATORS FISHER 4200 SERIES TRANSMITTER MOUNTING 10 (0.38) 204 (8) 1 111 (4.38) GE16563-A / IL MOUNTING BRACKET DIMENSIONS FOR FISHER 585CLS ACTUATORS WITH A 152 mm (6-INCH) CHANNEL NOTE: 1 FOR OTHER SIZES OF 585CLS ACTUATORS, THE MOUNTING PLATE LENGTH WILL CHANGE DEPENDING ON THE CHANNEL WIDTH. FISHER 4200 SERIES TRANSMITTER (LONG-STROKE) MOUNTING Figure 6. Mounting Dimensions 8

Product Bulletin 4200 Series Transmitters Table 4. Fisher 4211 and 4221 Electronic Position Transmitter EMC Summary Results Immunity PORT PHENOMENON BASIC PERFORMANCE TEST LEVEL STANDARD CRITERIA (1) Electrostatic Discharge (ESD) IEC 61000-4-2 4 kv contact 8 kv air A Enclosure Radiated EM field IEC 61000-4-3 80 to 1000 MHz @ 10V/m with 1 khz AM at 80% 1400 to 2000 MHz @ 3V/m with 1 khz AM at 80% A 2000 to 2700 MHz @ 1V/m with 1 khz AM at 80% Rated power frequency magnetic field IEC 61000-4-8 60 A/m at 50 Hz A Burst (fast transients) IEC 61000-4-4 1 kv A Surge IEC 61000-4-5 1 kv (line to ground only, each) B I/O signal/control 150 khz to 80 MHz at 3 Vrms Conducted RF IEC 61000-4-6 A 1 khz AM at 80% Specification limit = ±1% of span 1. A = No degradation during testing. B = Temporary degradation during testing, but is self-recovering. Table 5. Fisher 4200 Series Electronic Position Transmitter Hazardous Area Classifications CSA (Canada) CERTIFICATION BODY CSA TYPE CERTIFICATION OBTAINED ENTITY RATING 4211, 4221 4210, 4211, 4212, 4215, 4220, 4221, 4222 4210, 4211, 4212, 4215, 4220, 4221, 4222 (Intrinsic Safety) Class/Division Class I,II,III Division 1 GP A,B,C,D,E,F,G per drawing GE16020 (Explosion Proof) Zone Ex d IIC T5 Class/Division Class I, Division 1 GP B,C,D T5 U i = 30 VDC I i = 150 ma P i = 1.0 W C i = 5 nf L i = 0 mh TEMPERATURE CODE T4(T amb 71 C) ENCLOSURE RATING 4 T5 (T amb 71 C) 4 Class II Division 1 GP E,F,G T5 T5 (T amb 71 C) 4 Table 6. Fisher 4200 Series Electronic Position Transmitter Hazardous Area Classifications FM (United States) CERTIFICATION BODY FM TYPE CERTIFICATION OBTAINED ENTITY RATING 4211, 4221 4210, 4211, 4212, 4215, 4220, 4221, 4222 4211, 4221 4210, 4211, 4212, 4215, 4220, 4221, 4222 (Intrinsic Safety) Class/Division Class I,II,III Division 1 GP A,B,C,D,E,F,G per drawing GE16019 (Explosion Proof) Zone Class I Zone 1 AEx d IIC T5 Class/Division Class I, Division 1 GP A,B,C,D T5 Class I Division 2 GP A,B,C,D T5 Class II Division 2 GP F,G T5 V max = 30 VDC I max = 150 ma P i =1.0 W C i = 5 nf L i = 0 mh TEMPERATURE CODE T4 (T amb 71 C) ENCLOSURE RATING 4 T5 (T amb 71 C) 4 T5 (T amb 71 C) 4 Class II Division 1 GP E,F,G T5 T5 (T amb 71 C) 4 9

4200 Series Transmitters Product Bulletin Table 7. Fisher 4211 and 4221 Electronic Position Transmitter Hazardous Area Classifications ATE CERTIFICATE TYPE CERTIFICATION OBTAINED ENTITY RATING II 1 GD TEMPERATURE CODE ENCLOSURE RATING ATE 4211, 4221 Gas Ex ia IIC T4/T5 Intrinsic Safety Dust Ex td A20 IP66 T81 C (T amb 71 C) Ex td A20 IP66 T50 C (T amb 40 C) U i = 30 VDC I i = 150 ma P i = 1.0 W C i = 5 nf L i = 0 mh T4 (T amb 71 C) T5 (T amb 40 C) IP66 II 3 GD 4211, 4221 Gas Ex nl IIC T4 Type n Dust Ex td A22 IP66 T81 C (T amb 71 C) T4 (T amb 71 C) IP66 10

Product Bulletin 4200 Series Transmitters 11

4200 Series Transmitters Product Bulletin Fisher is a mark owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end-user. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com Fisher 12 Controls International LLC 1985, 2009; All Rights Reserved