Solitel Vibrating Rod Level Switch

Similar documents
Solitel Vibrating Rod Level Switch

Echotel Model 910 Ultrasonic Level Switch

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

Echotel Model 911/921 Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Model 910 Ultrasonic Level Switch

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

RHS SERIES RH Set Point Controller/Probe

Non-Submersible Industrial Pressure Transducer

Kotron Series 82 CE. Level. Transmitter. Installation and Operating Manual

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

Instruction Manual. HB Series Mini Level Sensor

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 350/351

MODEL AT-10 ANALOG TRANSMITTER

Programmable K-Factor Scaler B and Programming Software Kit B

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM

Technologies, Solutions, and Applications. Level Switching

Echotel Model 961/962 Ultrasonic Level Switches

Princo MagneLevel Model LML

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

Broadband Step-Up Transformer. User Manual

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Model Sono-Trak Transit Time

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Operator s Manual. PP022 Passive Probe

BUL L E T I N I N S T A L L A T I O N & O P E R A T I O N. DuraVibe. Ordinary Location and Hazardous Location. Standard Diamond-Shaped Probe

Spring Return DuraDrive Proportional Actuator

CS02 CAPACITANCE TRANSMITTER. Continuous Output Transmitter with Advanced Features INSTALLATION AND OPERATIONS MANUAL

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch

K-FACTOR SCALER B & B

Broadband Current Probe Series Operation Manual

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

ECHOTEL 961/962 LINE POWERED

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Operator s Manual. PP016 Passive Probe

R.F. Capacitance Dual-Point Level Control INSTALLATION & OPERATION MANAUL

Operator s Manual. PP017 and PP018 Passive Probes

H O R I Z O N G U I D E D W A V E R A D A R

ChuteMaster Microwave-blocked chute detection and point level instrument

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

Instruction Manual Inductive Gauging Sensor

Non-Spring Return DuraDrive Modulating Actuator

Horizon Model 704 Guided Wave Radar Level Transmitter

CSIS CAPACITANCE TRANSMITTER. Intrinsically-Safe Continuous Output Level Transmitter INSTALLATION AND OPERATIONS MANUAL

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Global Water Instrumentation, Inc.

One Revolution Tube Cutter

Instruction Manual Model M Switch, DPDT, Manual Select

LT3000 ULTRASONIC LEVEL TRANSMITTER

200Amp AC Clamp Meter + NCV Model MA250

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

ECHOTEL 961/962 LINE POWERED

OPM 3000 Opacity/Dust Density Monitor

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Non-Spring Return EconoDrive Proportional Actuator

I N S T R U C T I O N - M A N U A L RF-ADMITTANCE POINT LEVEL SWITCH

Guided Wave Radar Liquid-Liquid Interface Transmitter

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Broadband Current Probe Series Operation Manual

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

Digital Lighting Systems, Inc.

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Instruction Manual IUC-7X-RTX. X=1: Deg. F. X=2: Deg. F. X=3: Deg. F. X=7: X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7:

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Digital conductivity transmitter

MODEL: M2DYS SEN TRONIC AG

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1-

Model SPDT Power Switch Module

SHEET METAL MACHINES, INC. SAFETY & INSTRUCTION MANUAL FOR MODEL N12016 BRAKE MADE IN USA

AC/DC Current Oscilloscope Probe Model SL261

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

Low Frequency Velocity Sensor

Soliphant T FTM20, FTM21

AMP-13 OPERATOR S MANUAL

V-SOLDER BON-8103/8203. V-cut solder machine. Applicable solder wire diameter 0.3 ~ 0.8 mm

Transcription:

Solitel Vibrating Rod Level Switch D E S C R I P T I O N Solitel Vibrating Rod Level Switches provide reliable level detection of powders and bulk solids. This compact, integral switch is suitable for high or low level detection in hoppers or silos. It may also be used for plugged chute detection. The single-piece probe and the unique self-clean cycle avoid problems of buildup. Sensitivity of the instrument can be adjusted to detect a variety of solid materials ranging from heavy granular materials to light powders with bulk densities less than one pound per cubic foot. T E C H N O L O G Y The Solitel rod vibrates at a frequency of 350 Hz. When in contact with the media, the vibration is dampened. The attenuation of the vibration is detected by the integral mount electronics which change the states of the relay. The unique self-clean feature is activated when the vibration is dampened. The self-clean circuitry increases the amplitude of the vibration to dislodge any build-up which may have occurred. F E A T U R E S Single rod design eliminates clogging High temperature version up to 320 F (160 C) Self-clean cycle and polished probe minimize solids build-up Class I, Div. 2 and Class II, Div. 1 approval Adjustable sensitivity adjustment allows easy calibration for various bulk densities Extended rigid probes up to 100 inches (2540 mm) Extended flexible lengths to 65 feet (20 meters) A P P L I C A T I O N S Powders and bulk solids with maximum particle size of 1 2 inch (10 mm) including: Plastic powders and pellets Wood chips and sawdust Pulverized coal Fly ash Cement, lime Perlite Aerosil (fume silica)

S P E C I F I C A T I O N S Input voltage 110 VAC +10/-15% 220 VAC +10/-15% 24 VDC (±10%) Power consumption Less than or equal to 3 VA Operation frequency 350 Hz Output relay SPDT 8 amp @ 250 VAC (resistive) SPDT 1 amp @ 24 VDC (resistive) Time delay 4 to 10 seconds (depending on sensitivity adjustment) Process 1 1 2" NPT Housing NEMA 4X, 9 Operating process temperature Standard: -4 to +230 F (-20 to +110 C) Enhanced performance: -40 to +320 F (-40 to +160 C) Ambient electronics temperature -40 to +140 F (-40 to +60 C), refer to chart below Relative humidity 98% Maximum process pressure 360 PSIG Materials Vibrating rod: 316 stainless steel Rigid extension: 316 stainless steel Cable for flexible probe Polyethylene coated steel Insertion length Standard VXH: 8.25 inches (209 mm) Extended rigid probe VXR: 10 to 100 inches (25 to 254 cm) Extended flexible probe VXK: 3 to 65 feet (1 to 20 meters) 180 F (60 C) Ambient Temp. -40 F (-40 C) 95 F (35 C) 0 0 167 F (75 C) 320 F (160 C) -40 F (-40 C) Process Temp. AGENCY APPROVALS AGENCY MODEL APPROVED APPROVAL CLASSES CSA VXX-D1BX-XXX Class I, Div. 2; Groups A, B, C, & D Class II, Div. 1; GroupE, F, & G, TYPE 4X These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. NRTL/C These units have been evaluated to the applicable UL and CSA standards. CSA is accredited as a NRTL (National Recognized Testing Laboratory) in the United States. 2

M O D E L N U M B E R S T A N D A R D & E X T E N D E D R I G I D Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). DESIGN TYPE 1 Standard, -4 to +230 F (-20 to +110 C), insertion length in inches 2 Enhanced performance, -40 to +320 F (-40 to +160 C), insertion length in inches 3 Standard, -4 to +230 F (-20 to +110 C), insertion length in centimeters 4 Enhanced performance, -40 to +320 F (-40 to +160 C), insertion length in centimeters PROBE TYPE H Standard rigid probe, 8.25" insertion length R Extended rigid probe, see Insertion length below INPUT VOLTAGE 0 110 VAC 1 220 VAC 2 24 VDC INSERTION LENGTH Probe Type Code R, Design Type Code 1 or 2 Length in inches from 10 to 100 inches (example: 10 inches = Code 010) Probe Type Code R, Design Type Code 3 or 4 Length in centimeters from 25 to 254 cm (example 25 cm = Code 025) Probe Type Code H, Design Type Code 1 or 3 Specify Code 000 Probe Type Code H, Design Type Code 2 or 4 Specify Code 000 V D 1 B 3

M O D E L N U M B E R E X T E N D E D F L E X I B L E DESIGN TYPE 1 Standard, -4 to +230 F (-20 to +110 C), insertion length in feet 3 Standard, -4 to +230 F (-20 to +110 C), insertion length in meters INPUT VOLTAGE 0 110 VAC 1 220 VAC 2 24 VDC INSERTION LENGTH Design Type Code 1 Length in feet from 3 to 65 feet (example: 10 feet = Code 010) Design Type Code 3 Length in meters from 1 to 20 meters (example 15 meters = Code 015) V K D 1 B D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m ) plugged 4.63 (117) Dia. 3.44 (87) Rotation clearance 4.63 (117) Dia. 3.44 (87) Rotation clearance 4.63 (117) Dia. 3.44 (87) Rotation clearance 3.63 (92) 2.75 (69) 3.63 (92) 2.75 (69) 3.63 (92) 2.75 (69) Insertion length 8.25 (209) 6.34 (161) Conduit 1 1 /2" NPT process 1.73 (44) Dia. plugged Insertion length 1 1 /2" NPT process 1.73 (44) Dia. Conduit plugged Insertion length 1 1 /2" NPT process 1.73 (44) Dia. 1.73 (44) Dia Conduit 6.34 (161) 6.34 (161) Standard Rigid Probe Extended Rigid Probe Extended Flexible Probe 4

INSTALLATION IMPORTANT: Handle the instrument with great care, especially the probe. Any impact on the probe can damage the vibration system. Ensure that the slope angle of the material is considered when positioning the probe in the vessel. When using an extended version for low level alarm, mount the probe above the outlet of the vessel to avoid the probe being dragged along by the outflowing material. Side mounted units are best installed at an angle. Avoid mounting the sensor in a recess where build-up could dampen the vibration. A deflection plate is required when the probe is exposed to falling material or, in the case of a low level switch, when the drag force of the emptying material exceed the specifications. Observe the specifications for bending force(f), torque(m) and pull force(f) as indicated below: Standard: F = 100 pounds (445 N) M = 63 foot pounds (85 Nm) Extended Rigid: M = 63 foot pounds (85 Nm) Extended Flexible: F = 10,000 pounds (45 kn) VXH VXR VXK F M M F 5

Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. E S P Expedite Ship Plan Several Solitel Vibrating Rod Level Switches are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 56-601. 5300 Belmont Road Downers Grove, Illinois 60515-4499 630-969-4000 Fax 630-969-9489 www.magnetrol.com 6291 Dorman Road Mississauga, Ontario L4V-1H2 905-678-2720 Fax 905-678-7407 Heikensstraat 6 B 9240 Zele, Belgium 052 45.11.11 Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. Burgess Hill, Sussex RH15 9TL U.K. 01444-871313 Fax 01444-871317 Copyright 2002 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. BULLETIN: 56-101.5 EFFECTIVE: April 2002 SUPERSEDES: June 1999 Performance specifications are effective with date of issue and are subject to change without notice. The brand and product names contained within this document are trademarks or registered trademarks of their respective holders.