A METHOD OF CERTIFICATION FOR LTE SMALL CELLS IN THE HFC NETWORK

Similar documents
A DISCUSSION ON QAM SNARE SENSITIVITY

CPD POINTER PNM ENABLED CPD DETECTION FOR THE HFC NETWORK WHITE PAPER ADVANCED TECHNOLOGY

Screening Attenuation When enough is enough

LTE Band 7. Channel

QAM Snare Isolator User Manual

AN INTRODUCTION TO A NEW MICRO-REFLECTION LOCATION TECHNOLOGY

XCOR TODAY S APPROACH TO DETECTING COMMON PATH DISTORTION

Digital Leakage Today

LTE Interference UHF Leakage

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

9. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY

White Paper. 850 MHz & 900 MHz Co-Existence. 850 MHz Out-Of-Band Emissions Problem xxxx-xxxreva

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Signal Leakage Patrolling in the 700 MHz Frequency Band

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

Antenna Performance. Antenna Performance... 3 Gain... 4 Radio Power and the FCC... 6 Link Margin Calculations... 7 The Banner Way... 8 Glossary...

STC Test Report. Date : Page 1 of 13 No. : HM161169

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

QAM Snare Snoop User Manual

Proposal for ACP requirements

White Paper 850 MHz & 900 MHz Co-Existence 900 MHz Receiver Blocking Problem

Arqiva DAB Car receiver tests in the UK

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

Digital Leakage Today

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

EMC Evaluation at Green Bank: Emissions and Shield Effectiveness

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR49 August 29, 2012 First Approval Report

FCC Radio Test Report. Orpak Systems Ltd.

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

2. ETSO 2C40c#3 VHF Omni-directional Ranging (VOR) Equipment

Test Report Version. Test Report No. Date Description. DRTFCC Sep. 12, 2014 Initial issue

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

CX380X Advanced Spectrum and Burst QAM Analyzer

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Low Band Receiving Antennas

QAM Snare Navigator Plus User Manual

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

TEST REPORT NO. DATE DESCRIPTION

Radiated Spurious Emission Testing. Jari Vikstedt

FCC Verification TEST REPORT

FCC Test Report. Report No.: PTCDQ FC01

TEST REPORT. Table of Contents

Federal Communications Commission Office of Engineering and Technology Laboratory Division

Application Note: PathTrak QAMTrak Analyzer Functionality. Overview

Spectrian Dual Mode Cellular Power Amplifier Model No.: SCLPA 800 CR FCC ID: I2ONTHX51AA

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

Sunlight Supply, Inc.

Complimentary Reference Material

FCC PART 15 B CLASS B TEST REPORT

Rec. ITU-R F RECOMMENDATION ITU-R F *

ECC Report 276. Thresholds for the coordination of CDMA and LTE broadband systems in the 400 MHz band

TEST REPORT. Table of Contents

ADJACENT BAND COMPATIBILITY BETWEEN GSM AND TETRA MOBILE SERVICES AT 915 MHz

FCC PART & IC RSS GHz FHSS TEST REPORT

PRODUCT CATALOG. RF Test. VIAVI Solutions. Antennas

Computime Ltd. Application For Certification (FCC ID: DI2ML815TKT) Transmitter

FCC CERTIFICATION TEST REPORT

TEST REPORT. Table of Contents

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR

STUDIO TO TRANSMITTER LINKING SYSTEM

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

Return Plant Issues SCTE Cascade Range Chapter. Micah Martin January 13, 2008

Network Design Considerations and Deployment Concerns for a Ground Aircraft Communication System

Searcher Plus GT Leakage Detector OPERATION MANUAL

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR50 August 29, 2012 First Approval Report

Frequency Reuse How Do I Maximize the Value of My Spectrum?

6 th INTERNATIONAL FORUM ON DIGITAL TV, LA HABANA November 5 to 7, 2018 DIGITAL DIVIDEND SPECTRUM SHARING ISSUES

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 CERTIFICATION TEST REPORT FOR. WLAN 2X2 MIMO a/b/g/n/ac with BLUETOOTH

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

SET Congress Sao Paulo 24 August in the 700 MHz band

Description of Test Facility

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

T A B L E O F C O N T E N T S DESCRIPTION PAGE

Cell Extender Antenna System Design Guide Lines

FCC 47 CFR PART 15 SUBPART C ANSI C63.4: 2009

(Channel Bandwidth: 5 MHz)_MCH_16QAM_1RB#0

2016 Spring Technical Forum Proceedings

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Measurement Procedure & Test Equipment Used

TECHNICAL AND POLICY CONSIDERATIONS FOR BROADBAND POWERLINE (BPL) COMMUNICATION (2 30 MHz)

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR:

EMI -- T E S T R E P O R T

IEEE C /008. IEEE Broadband Wireless Access Working Group <

Broadband System - J

RF test report AU01+W02

International Journal of Engineering and Technology Volume 3 No. 6, June, 2013

UNIDEN AMERICA CORPORATION 4700 AMON CARTER BLVD. FORT WORTH TEXAS UNITED STATES

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

FCC Part 22H & 24E Measurement and Test Report

Transcription:

A METHOD OF CERTIFICATION FOR LTE SMALL CELLS IN THE HFC NETWORK 185 AINSLEY DRIVE SYRACUSE, NY 13210 800.448.1655 I WWW.ARCOMDIGITAL.COM

One of the problems associated with installations of LTE Small cells co-located on the HFC network is interference of LTE Tx signal with QAM signals carried on the network (LTE Ingress). This paper quantifies the level of leaks that will likely need to be mitigated to avoid interference, it describes the sensitivity required of a detector used in this application, and it proposes possible certification procedures that could be performed at locations where small cells will be installed. One method for estimation of interference from the LTE Tx signal is an expansion upon data acquired from drive outs performed at or very close to the LTE frequency. The test methodology would include the standard steps of measuring leakage by patrolling the HFC plant, and calculation of leak location. It would then need to be expanded to include measuring or calculation of the field strength of the LTE Tx signal at each leak location point, and then a calculation of CNR in the cable depending upon the level of QAM signal. This method has some disadvantages. 1. Leak source radiation patterns are assumed to be omni-directional, while in reality they fluctuate significantly and each leak can have nulls or maximums in the direction of the LTE Small cell. 2. Imprecision of the leak location will cause further inaccuracy of the re-calculation of leak level with respect to 10 feet and further inaccuracy of estimating CNR in the cable. 3. Re-calculation of LTE Tx signal level to the point of leak location in most cases is not very accurate because actual obstructed path losses of signal is random due to multipath effects, etc. 4. Invisibility to very small leaks due to the sensitivity of existing equipment. 2

While in general the drive out data is very useful with regard to general plant maintenance and monitoring for LTE egress and ingress, these imprecision points noted above for the LTE small cell scenario show that it is not reliable enough to be used exclusively in this application. A better method will be described below that discusses a certification procedure at the LTE Small cell location, with ongoing monitoring post-certification provided from a combination of drive-out data highlighting the cumulative level of all leaks at the Small cell location and from SNR at the LTE band of modems downstream of the Small cell. The alternative method of estimation of interference is based on measuring QAM leak levels from the point of the radiation interfering signal, i.e. from the location of the LTE Small cell. In this case both the radiation pattern of the leak source and the actual obstructed path losses of the leak signal (including multipath effects) will be taken into consideration. The allowable leakage level at the 750 MHz LTE band can be defined from formula (10) in the Arcom Digital Quantifying leakage thresholds for QAM LTE interference technical paper as follows: E Leak = 2 U qam - P Tx G Tx - CNR + 20 log D + OPL + 27.67, (1) where Eleak - is allowable leak level at distance 3 meters in dbμv/m; D is the distance from LTE transmitter to leak source in meters; P Tx is power of LTE transmitter in dbm; G Tx LTE transmitter antenna gain in dbi; OPL is obstructed path loss including leak source radiation pattern loss in db; CNR - is threshold of allowable CNR for QAM signal at cable in db (33 db for QAM-256). 3

The same leak signal at the location of the LTE Small cell will have level: ADVANCED TECHNOLOGY EleakLTE = E Leak - 20 log D - OPL + 20 log (3m) = 2 U qam - P Tx G Tx - CNR + 37.21 (2) Note, that the allowable leak level at the location of the LTE Small cell does not depend upon the distance to the leak (assumption being that the distance is more than 3 meters). In other words, in the case of measuring the leak level from the Small cell location, the allowable leak threshold for a leak located, for example, at a distance of 3 meters and for leaks located at distance 30 or 300 meters is the same and defined by formula (2). Also the allowable leak level measured at the Small cell location does not depends upon OPL (leak radiation pattern and other obstructed path loses). This means that all of the above random parameters are already taken into consideration and that there is no need to measure each leak locally from a distance of 3 meters, or to calculate LTE level and QAM signal levels at each location a significantly more practical approach than the initially described scenario. That is the good news, the problem becomes that the main challenge of measuring allowable leak level at the Small cell location is the required very high sensitivity of the leakage detector. The table below shows the allowable leak level for Small cells (Ptx = 43 dbm, Gtx = 4 dbi) depending from QAM signal level in cable with a threshold CNR=33 db. 4

The QAM signal level used should not be the QAM Signal at the point of the Small cell, but at the lowest level of plant in proximity to the Small cell where there is a potential leak source. As such, in this expected worst case where the signal level at cable is 10 dbmv, the sensitivity of QAM leakage detector should be better than 0.1 dbμv/m. Current leakage detectors used in the cable industry can t provide this sensitivity at the LTE band even with using directional active yagi antenna. For example, the sensitivity of Rohde& Schwartz leakage detector EFL110/220 with active yagi antenna at LTE band is only 11 μv/m, 40 db worse than the required sensitivity of 0.1 dbμv/m. To provide the required sensitivity we propose to use a cross-correlation QAM leakage detector (the same as the QAM Snare product), but with substantially longer signal accumulation time and with the reference QAM samples captured directly from the cable network where the Small cell will be installed. The current QAM Snare leakage detector implemented for drive-out was engineered for the desired sensitivity of the application and has sensitivity of approximately 3 μv/m at LTE band with an accumulation time of 1.2 msec and for a dipole loop antenna with gain of 4 dbi. Increasing the accumulation time from 1.2 msec to 100 msec will increase sensitivity by at least 25 db plus an additional 6 8 db is expected from using a directional active yagi antenna. The total expected improvement in sensitivity is more than 30 db or 30 times in μv/m. The block diagram of the proposed certification system is shown below. 5

The system works as follows. Technician sets up the required QAM channels for measuring leak (because of the different frequency response of leaks it is expected that multiple channels will need to be tested, likely four different QAMs at the LTE band), with antenna polarization (horizontal and vertical). Because all directions will need to be scanned for multiple channels and to avoid human error by scanning too quickly or in the wrong direction, an automated setup with an antenna rotator will be utilized. The system starts to scan different directions at azimuth plane and detects leak at selected QAM channels automatically. The results of scanning are stored in detector memory in the format: Polarization Azimuth - QAM channel - Leak level -Time delay. Then recorded data can be downloaded into computer for analysis and reporting. An example of the leak detector screen showing a detected leak is shown below. An alternative technique which could also be used for certification of Small cells is generation of a CW pilot signal at frequencies between adjacent QAMs at the Small cell location and then monitoring forward spectrum captured by cable modems (CM) within the nearest nodes. This method is shown at the picture below. Of course, generation of CW signal with a power of 20 W (same power as at Small cell) will likely require FCC approval because un-modulated CW signal can produce interference to other LTE cells. 6

CW TX signal can be placed, for example, at a frequency of 726 MHz between QAM channels 112 and 113. If this CW Tx signal enters the cable due to bad isolation, then it will be detected at FWD spectrum captured by CMs. Lab test shows (see below) that for RezBW = 30 khz (which is provided in case of capture spectrum at CM) the CW pilot with relative level -33 dbc (CNR threshold for QAM-256) can be detected between adjacent QAMs. But for effective detection it will be required to accumulate a number of captured spectrums from each of CM. This described process and approach would present a challenge to go in the field to affect repair, because the direction of the leak would not be known. 7

As described, the preferred process would be to certify a location prior to the Small cell activation using the coherent cross correlation technique with large accumulation time. Direction of the leak will be indicated, and the leaks can be mitigated using the other QAM Snare leakage detector tools intended for line technicians, operating at the same frequencies used for this certification. For ongoing maintenance, existing tools within the management software provide very useful data with regard to cumulative leak levels at each Small cell location, and alarms can be generated when the cumulative number exceeds some threshold level. While there will be inaccuracies in this number that have been previously discussed, it does provide some useful metrics. An example is shown below where the leak level existing at any location can be calculated and displayed. And lastly, as an additional monitoring tool, a realistic method for detection of LTE ingress is to place DOCSIS QAM channels or OFDM channels into the bandwidth of the LTE down-link spectrum and analyze degradation of SNR measured by CM. Using broadband spectrum capture to detect LTE ingress in all scenarios is not possible because the QAM signal level at CM input is too low and the corresponding LTE ingress of -30 dbc is below the noise floor. 8

WWW.ARCOMDIGITAL.COM FOR MORE INFORMATION CALL I 800.448.1655 OUTSIDE THE U.S. DIAL I +1.315.422.1230