Medium power busbar trunking

Similar documents
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Busbar Trunking Assembly

Canalis KS. Contents. Presentation. Description. Catalogue numbers Dimensions. Installation

Prefabricated busbar trunking KS A. Canalis. Catalogue

BUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Characteristics 5 TeSys k contactors and reversing contactors

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

MISTRAL SYSTEM IMPACT 2

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

Busbar and Modular Wiring Systems

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

3 - Protection components Circuit-breakers

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Low Voltage. Canalis. prefabricated busbar trunking from 20 to 400 A. Catalogue 2010

(1,5 modules per pole)

Electrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installing with LI system

Totally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system

Current / residual current and voltage transformers. Current / residual current and voltage transformers

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Cast resin transformers HARMONY TM

Cable Management Solutions with DLP TM

Multi-conductor Lighting Busbar System A

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

Raised Floor system LIMOGES Cedex. Phone : Fax :

Technical features table for miniature circuit-breakers SH 200 Series

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

TYPE APPROVAL CERTIFICATE

Mobile distribution Canalis KXA (50 to 160 A) with mobile connections

GROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

MODULOBLOC TRANSFORMERS

Empty enclosures AKL / AKi ITC - AKL / AKi Enclosures

Digital flow transmitter for continuous flow measurement

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

SUPER COMPACT - SCP 6 SUPER COMPACT

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

MINI-PS AC/24DC/1.3

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS

Controls Contactors and Contactor Assemblies Special Applications

Ceiling mounting application, U support and bracket. Standard mounting of a cable tray with support, type US.., and suitable support bracket, type AW.

Protection components

Measuring current transformers of the W, W series

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

Reduction - RD. Sample Order: 2000A / 1600A, Aluminium, Bolt-on, IP 55, 4 conductors KXA B - RD17. Right Side Feeder "T" Sample Order: B

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems

Digital flow ELEMENT transmitter for continuous flow measurement

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Low-Voltage Power Distribution and Electrical Installation Technology

GLS A GLS 15

Flush Floor system LIMOGES Cedex. Phone : Fax :

E-STOP relays, safety gate monitors

Cablelink Plus Flush Technical

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

SUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

OptiLine 45 Floor boxes

Coordination and protection of busbar distribution

Low-Voltage Power Distribution and Electrical Installation Technology

ALPHA DIN Wall-Mounted. Distribution Boards

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure transmitter For general industrial applications Model A-10

Automatic capacitor banks with detuned filters

Sizing conductors and selecting protection devices

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

VCE VET ENGINEERING STUDIES CERTIFICATE II

50 YEARS+ HX Range Catalogue. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

Safety switches with slotted hole lever

QUINT-PS-24DC/24DC/10

Output of three-phase motors at 50 Hz and 400 V

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Wanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Powerlink Plus Technical

Open Type Without Enclosure

Digital flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Electronic Circuit Breaker with reset input ESS20-1..

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

NEW CIRCUIT PROTECTIONRANGE

SIRIUS/SIKOSTART Soft Starters For Standard Applications

3. Barrier elements. Barrier posts. Stainles steel

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Transcription:

Canalis KS (100 to 800 A) For high density distribution in industrial and commercial buildings Presentation 4 1 2 5 1 Run components 7 ratings : 100, 160, 250, 400, 500, 630 and 800 A 4 live conductors. Straight lengths in fixed lengths of 1.5, 2. 3 and 5 m, cut to length for 0.5 to 2 m. 2 3 Connection components, feed units and end covers Feed the KS trunking from either end or along a run. Components for changing direction For adapting the Canalis KS to installation requirements : elbows, tees, crosses. 11030/2 Te

0 1 4 3 4 5 1 4 5 2 4 5 6 Fixing brackets Tap-off units Accessories For fixing KS trunking. 25 to 400 A connectors and fused tap-off units, circuit-breakers or modular equipment. Dust and damp proofing accessories. Te 11030/3

Selection guide: pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description General Canalis KS is designed for medium power distribution with high tap-off density in industrial and commercial buildings (exhibition halls, hypermarkets, office blocks, etc.). The range is available in 7 ratings from 100 to 800 A. The standard IP 52 degree of protection makes KS suitable for the majority of locations. It can be increased to IP 54 by the addition of dust and damp proof blanking plates on the tap-off outlets. Tapping off is via tap-off units. These units, from 25 to 400 A, can be safely removed while live. 100 to 250 A trunking can take connectors and tap-off units up to 250 A. Higher rated trunking can take any tap-off unit from the range. Run components Straight distribution lengths 2 1 3 4 5 6 Straight lengths are designed to carry current and feed loads with low or medium power. The straight lengths form the structure of the run. They comprise : 1 A casing of galvanised sheet steel, which is crimped closed. This casing, shaped and ribbed by rolling, provides excellent resistance to bending and twisting. Three casing widths cover the whole range. Casings are available in two finishes : - 54 mm wide galvanised sheet steel for 100, 160 and 250 A ratings (sheet steel with RAL 7032 grey finish available as an option). - 75 mm wide sheet steel with RAL 7032 grey finish for 400 and 500 A ratings. - 113 mm wide sheet steel with RAL 7032 grey finish for 630 and 800 A ratings. 2 4 live conductors of the same cross-section : - Bimetal silver-plated copper/aluminium laminate for 100, 160 A ratings. - Aluminium fitted with bimetal silver-plated copper/aluminium laminate riders electrically welded to junctions and tapoff positions for 250 to 800 A ratings. The lamination is a patented process by which the copper and aluminium molecules are fused together under extreme pressure. 3 Fibreglass reinforced polyester isolators, at 250 mm intervals. These hold the conductors securely within the casing. 4 A special protected earth (PE) conductor of the same type as the live conductors with a cross-section 1/2 of the phase cross-section. It is connected to the casing at each junction. 5 Tap-off outlets on both sides of the trunking, at 1 m intervals. They are connected to the isolators to form a block, holding the bars. They have a shuttered outlet which is opened and closed automatically when connectors or tap-off units are plugged in or removed. 6 A mechanical and electrical jointing device. Electrical connection is via a block with spring and silver graphite contacts. This block absorbs the differential conductor/casing expansion of each length equally. For 100, 160 and 250 A ratings, it automatically and simultaneously connects all the live conductors, ensures continuity of the protective earth conductor and its connection with the casing. For higher ratings (315 to 800 A), the electrical connection is made by a 1/4 screw turn for each conductor. 11031/2 Te

Selection guide: pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description Special components i Fire barrier length To cross a fire partition, between two areas of a building. Fire resistance : 2 h (A120) conforming to ISO 834. i Made to measure length To alter the length of a run (for example, between two components for changing direction). These components are manufactured, on request, from 500 mm to 1995 mm, in multiples of 5 mm. They do not have tap-off outlets. Connection components and feed units Feed units To feed a KS run by cables or directly from a distribution panel. The feed can be from one end (end feed) or along a run (centre feed). They can be connected by aluminium or copper cables fitted with suitable cable lugs. There is an undrilled aluminium gland plate which will accept cable glands. This plate can be replaced by a plate fitted with 1 to 3 cable clamps depending on the rating (to be ordered separately). 2 1 End feed box For 100 A busbar trunking only. It is mounted to the left or right of a straight length and fitted with a no. 29 cable gland. 1 2 End feed units For 100 to 250 A ratings : mounted to the left or right of a straight length, by inverting the initial section of the trunking. For 400 to 800 A ratings : available in left or right hand versions. 4 3 3 Centre feed unit Through run type (1 cable feeds the right and left sections). It is mounted along the run, between 2 straight lengths. 4 Flange feed unit Fitted with splayed bars and a mounting plate. It is used for connection to a distribution panel. It can be mounted at either end of a component. Te 11031/3

pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description Connection components and feed units (continued) KV-KS connector The KV-KS connector is fitted with a KV end length at one end and a KS end length at the other. Due to its flexible design, it ensures direct connection from a feed run to a distribution run and reduces any risk caused by alignment faults. End cover The end cover protects and isolates the ends of the conductors. It is mounted on the last length. Three products cover the entire KS range : 100 to 250 A, 400 and 500 A, 630 and 800 A. Components for changing direction 2 1 1 Edgewise elbow. One model for each size of casing for turning to left or right. 2 Flat elbow Two models for each size of casing (one ascending, one descending). Flat and edgewise elbows can be manufactured, on request, with made to measure connection lengths, with multiple angles, with built-in fire barrier, etc. (please consult your Regional Sales Office). 3 3 Edgewise tee and cross For vertical branches on the main run. Fixing devices (630 1 (630-800) - 800) (400 500) (315 500) (100 250) (100 250) 1 Universal brackets These brackets are used to fix the distribution run to the structure of the building, directly or via a threaded rod, a bracket, etc. There is one model for each size of casing which can be used for all mounting methods : ceilingmounted, suspended, wallmounted, etc. Suspension on chains or steel cables is not recommended. It is advisable to leave a space of 3 m between each bracket. 11031/4 Te

pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description Tap-off units These are used for instant connection of loads or secondary runs (for example, for low power distribution using Canalis KN). The connectors and tap-off units conform to installation standards and regulations whatever type of neutral point connection is used (TT, IT, TNS or TNC). i They can be removed and moved whilst live, with no load. i The tap-off outlets are opened and closed automatically when units are plugged in or removed. i With the cover open, no live part can be accessed. Degree of protection IP 2X. i Connectors and tap-off units are made in two versions : - Protected version, degree of protection IP 40, suitable for most industrial and commercial applications, - Dust and damp proof version, degree of protection IP 54, for very dusty locations and environments, or those subject to water splashes. A B PE = A B Tap-off unit - Isolation is achieved by unplugging the tap-off. - The electrical equipment and connection terminals can only be accessed with the tap-off unplugged. - A safety device prevents the tapoff being plugged into the trunking if the cover is not in place. Tap-off units with isolator Isolation (AC22 to AC 20) is achieved by opening the cover of the unit. A number of safety devices prevent the following : - Connection of the tap-off unit if the cover is closed, - Opening of the cover if the unit is not locked to the trunking, - Removal of the unit if the cover is closed, - Opening of the cover to position I (by locking) on units which have a switch or circuit-breaker. These tap-off units will take accessories such as an early break contact on the cover, a sealing kit, etc. (see page 11043/3). Tap-off 1 Tap-off with fuse carrier The tap-off is protected by means of fuses (not supplied). They can be fitted with carriers for the following fuses : - NF 10 x 38 - BS type 88A1 - DIN type Neozed DO1 1 2 2 Tap-off for modular equipment This tap-off will take most 17.5 mm modular equipment. - Nominal current : 25 A, - Capacity : 4 modules, - With window in front panel (equipment can be seen and accessed). Te 11031/5

pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description Tap-off units (continued) Fused tap-off units 1 2 3 These fused tap-off units are designed to protect the tap-off by means of fuses (not supplied). They can be fitted with carriers for the following fuses : - NF and DIN, 50 to 630 A, - BS, 30 to 160 A, - VDE and DIN, 25 to 400 A. Versions for NF fuses can be fitted with a single phase protection device. 1 25 to 125 A fused off-load tap-off unit. 2 160 A fused off-load tap-off unit. 3 250 to 400 A fused off-load tap-off unit. These units can only be mounted on trunking which is installed horizontally on edge. To make installation easier, it is performed in two stages : - The unit is hooked onto the trunking, then automatically located in front of the tap-off outlet by moving it sideways. - The fixing brackets are then locked and the mobile power block plugged in, using an internal device. Tap-off units with isolator for modular equipment These units will take most 17.5 modular equipment. They have a window in the front panel (equipment can be seen and accessed). There are two ratings : - 50 A nominal current, capacity 7.5 modules, - 100 A nominal current, capacity 11 modules. 11031/6 Te

0 1 Medium power busbar trunking pages 11032/2 to 11032/4 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Description Tap-off units for Merlin Gerin circuit-breaker These units are designed to take Merlin Gerin Compact NS circuit-breakers : - 100 to 400 A rating, - Fixed, with front sockets, - Version N, H or L, - With or without residual differential device, - With rotary switch. For other types of circuit-breaker : please consult your Regional Sales Office. Tap-off unit for integral contactor-breaker This unit is designed to take Telemecanique integral contactorbreakers and inverters. Isolating tap-off unit for industrial control and monitoring equipment This unit has a Telequick mounting plate and will take industrial control and monitoring equipment (for example, for controlling lighting in hypermarkets). Nominal current : 125 A. Two sizes : - With 300 x 300 mm mounting plate, - With 400 x 600 mm mounting plate. IP 54 dust and damp proofing accessories 1 In normal mounting position (edgewise, horizontal installation) the degree of protection of the KS range is IP 52. In other positions (flat and vertical installation) the degree of protection is reduced to IP 50. To achieve a higher degree of protection, IP 54, the following accessories must be added to the straight lengths. 2 1 Edgewise horizontal installation 1 Each tap-off outlet which is not being used should be fitted with a sealed tap-off blanking plate. Flat and vertical installation 1 Each tap-off outlet which is not being used should be fitted with a sealed tap-off blanking plate. 2 Each junction between components should be fitted with a jointing sleeve. Te 11031/7

pages 11031/2 to 11031/7 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Selection guide Information required i The types of load, and their characteristics and locations. i The power source, and its characteristics and location. i The structure of the premises (availability of fixing points for trunking). i Any influences external to the installation site. (ambient temperature, dust, water, etc). Distribution run layout The siting of distribution runs depends on the position of the loads, the location of the general power supply and the availability of fixing points. A single distribution run can serve an area 5 to 8 metres wide. Selection of the trunking according to the rated operating current Ib Ib = total current x k1 Total current = sum of currents drawn by the loads on a run k1 = average demand coefficient Applications k1 Rated operating current Ib Selected trunking Lighting, heating 1 0...100 A KSi-10 100...160 A KSi-16 Distribution (Engineering shop floors) 160...250 A KSi-25 2 or 3 loads 0.9 315...400 A KSi-40 4 or 5 loads 0.8 400...500 A KSi-50 6...9 loads 0.7 500...630 A KSi-63 10...40 loads 0.6 630...800 A KSi-80 40 or more 0.5 Permissible current Iz according to the ambient temperature (at the installation site) The nominal current Inc of the trunking is specified for an average daily ambient temperature of 35 C (and a maximum of 40 C). Depending on the actual temperature, an uprating or derating coefficient (f1) may be applied to the nominal current Inc : see the characteristics on page 11032/5. Checking the voltage drop The voltage drop in Canalis KS is given in V/100m/A in the characteristics table on page 11032/5. Polarity selection 3-pole distribution + N + PE (IT-TT-TNS) 3L + PE (IT-TT-TNS) 3L + N + PE (IT-TT-TNS) i KSA-iiED4ii trunking 3-pole + N + PE tap-offs possible, type 3-pole + PE or 3-pole + N + PE 3-pole distribution + PEN (TNC) i KSA-iiED4ii trunking 3-pole + PEN tap-offs possible, type 3-pole + PEN (TNC) or 3-pole + N + PE (TNS).. 3L + PEN (TNC) 3L + N + PE (TNS) 11032/2 Te

pages 11031/2 to 11031/7 page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Selection guide Protecting the trunking against overloads To enable it to be extended, prefabricated busbar trunking is generally protected to its nominal current Inc (or to its permissible current Iz if the f1 coefficient is applied according to the ambient temperature). Protection using fuses i Calculate the standard nominal current In of the fuse so that : In Inc 1 i Select the standard rating In which is equal to or immediately below. Check that In Ib. If this is not the case, select the next highest rating of trunking. Note : Protecting trunking using fuses is the same as limiting the rated operating current. Protection using a circuit-breaker i Select the circuit-breaker setting current Ir so that : Ib Ir Inc Note : Protecting trunking using a circuit-breaker makes it possible to use the trunking at full capacity. Electrodynamic protection against short-circuit currents The electrodynamic withstand of the trunking should be taken into account when selecting a protective device (permissible rated peak current). i Determine (1) the 3-phase short-circuit current, prospective lcc 3 (KA) at the start of the Canalis KS. i Check, on the current limitation curve of the selected protective device, that this limits the peak current (kâ) to a value below the permissible rated peak current of the KS trunking. Limited current Canalis current Protection using a Merlin Gerin Compact circuit-breaker The circuit-breaker/canalis coordination table below gives the maximum short-circuit current for which the KS trunking is protected, according to the type of circuit-breaker. Prospective Icc 3, max (Ka rms) voltage 380/415 V Canalis KS : rating (A) 100 160 250 400 500 630 800 Type of NS100 N 25 Merlin Gerin H 25 circuit-breaker L 25 NS160 N 20 36 H 20 70 L 20 70 NS250 N 36 36 H 55 70 L 55 150 NS400 N 45 45 H 45 70 L 45 150 NS630 N 45 45 45 H 70 70 70 L 150 150 150 C801 N 40 50 H 40 50 L 55 50 C1001 N 50 H 50 L 80 (1) By calculation or using graphs, precalculated tables, etc. Te 11032/3

page 11032/2 Caracteristiques : page 11032/5 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Selection guide Selection of IP degree of protection External influences are taken into consideration when siting the installation. The IP 52 degree of protection of Canalis KS means that it is suitable for installation in most industrial and commercial locations. For locations or sites which may be subject to water splashes in any direction the degree of protection should be raised to IP 54, by installing KSE-80YB2 sealed tap-off blanking plates (see page 11043/2). Changing levels in horizontal distribution KSA- LP42 KSE- YAi KSA- LP41 When trunking is mounted vertically, the degree of protection at a junction is IP 50. To maintain a degree of protection higher than IP 50, if required, each junction installed vertically must be fitted with a sealed jointing sleeve (IP 54). (See page 11043/2). Tap-off units n There are 2 ranges of tap-off units. i IP 40 protected range, low-cost and suitable for normal industrial and commercial environments. i IP 54 dust and damp proof range, for very dusty or damp environments. KSA-ii IP 40 KSE-ii IP 54 n Mounting position Edgewise Flat The preferred mounting position (for horizontal distribution) is edgewise. In some installation configurations (false ceiling, false flooring, locations with very little space, etc.) it may be necessary to install trunking flat. There are several suggestions for this. Please consult your Regional Sales Office. Selecting the power supply i 100 A end feed and 250 A (160 A) feed unit - mounted at either end of a run, - all types of neutral system. B A i 500 and 800 A feed unit. Two types depending on position : - right hand mounting (fig. A), - left hand mounting (fig. B). All types of neutral system. Connected by means of lugs. 11032/4 Te

pages 11031/2 to 11031/7 page 11032/2 References : pages 11033/3 to 11038/3 pages 11040/2 to 11042/3 Canalis KS (100 to 800 A) Characteristics (1) Type of trunking KSA-10 KSA-16 KSA-25 KSA-40 KSA-50 KSA-63 KSA-80 General Characteristics Number of live conductors 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 Rated thermal current lth A 100 160 250 400 500 630 800 Rated insulation voltage V 660 660 660 660 660 660 660 conforming to IEC 158-1 Rated operating voltage V 660 660 660 660 660 660 660 Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Conductor characteristics Live conductors Rb0 ph Average resistance per mω/m 1.059 0.490 0.216 0.142 0.091 0.074 0.045 conductor, cold state (ambient temperature 20 C) Rb1 ph Average resistance per mω/m 1.395 0.661 0.294 0.190 0.123 0.101 0.061 conductor at Ith (ambient temperature 35 C) X ph Average reactance per mω/m 0.457 0.233 0.192 0.112 0.116 0.070 0.071 conductor Z ph Average impedance per mω/m 1.468 0.701 0.351 0.221 0.170 0.123 0.094 conductor Protective conductor Cross-section (copper equivalent) mm 2 66 78 78 127 127 247 247 Average resistance, cold state mω/m 0.270 0.230 0.230 0.142 0.142 0.074 0.074 (ambient temperature 20 C) Fault loop impedance at 6 Ith Between live conductors mω/m 3.384 1.708 0.811 0.541 0.428 0.279 0.237 Between live conductors and PE mω/m 2.090 1.139 0.720 0.512 0.439 0.317 0.289 Other Characteristics Short-circuit withstand capacity Permissible rated peak current ka 13.6 22 28 49.2 55 67.5 78.7 (3-phase) Permissible rated short time current ka rms 8 11 14 24.6 27.1 32.5 38.3 (0.1 s) Maximum thermal limit A 2 s 6.8.10 6 20.2.10 6 100.10 6 354.10 6 733.10 6 1096.10 6 1798.10 6 Degree of protection In normal mounting position. Horizontal, edgewise installation. Standard IP 52 IP 52 IP 52 IP 52 IP 52 IP 52 IP 52 With sealing accessories IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 Other positions : horizontal installation, flat, vertical installation. Standard IP 50 IP 50 IP 50 IP 50 IP 50 IP 50 IP 50 With sealing accessories IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 Voltage drop Composite voltage drop, hot state, expressed in V/100 m/a for 3-phase 50 Hz current, with load distributed along the run. Where the load is concentrated at the end of the feed run, the voltage drops are twice the values indicated in the table. For a power factor 0.7 V/100 m/a 0.112 0.055 0.030 0.0184 0.0146 0.0104 0.0081 cos ϕ of 0.8 V/100 m/a 0.120 0.058 0.030 0.0190 0.0146 0.0106 0.0079 0.9 V/100 m/a 0.126 0.060 0.030 0.0190 0.0140 0.0105 0.0074 1.0 V/100 m/a 0.121 0.057 0.025 0.0164 0.0107 0.0087 0.0053 Determination of permissible current Derating or uprating factor to be applied to the rated thermal current of the trunkingwhere the average daily ambient lz for a busbar trunking system, temperature is other than 35 C. according to ambient temperature Average ambient temperature C 10 15 20 25 30 35 40 45 50 55 60 Factor f1 1,10 1,08 1,06 1,04 1,02 1,00 0,97 0,94 0,91 0,88 0,85 (1) Conforming to international standard IEC 439-2 and European standard EN 60439.2 Te 11032/5

KSA-iiEDiii KSA-iiAB4ii KSA-iiEF4ii KSA-iiTC40 KSA-iiEZi KSA-iiLC40 KSA-iiEDiii KSB-iiFA2 KSE-80YB2 KSA/KSE-05SFii KSA/KSE-iiDBi11 KSA-iiLC40 KSA-iiES4A KSA-iiLP42 11033/2 Te KSA-iiLP41 KSE-iiYAi

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 pages 11040/2 to 11040/5 Canalis KS (100 to 250 A) References Run components (IP 52/IP 54) (1) Description Rating Length Number of 3L + N + PE and 3L + PEN Weight A mm tap-offs Reference kg Straight 100 5000 10 KSA-10EA450 19.050 lengths 3000 6 KSA-10EA430 11.900 160 5000 10 KSA-16EA450 21.200 3000 6 KSA-16EA430 13.200 250 5000 10 KSA-25EA450 25.000 3000 6 KSA-25EA430 15.500 250 (2) 2000 8 KSA-25ED420 10.650 1500 6 KSA-25ED415 8.350 Straight length 250 (2) 500 1995 KSA-25ES4A (3) 8.000/m cut to length Fire barrier 250(2) 1200 2200 KSA-25EF4A (3) 8.000/m length Connection components and feed units (2) Description Rating Connection Mounting Reference Weight A Type/Max.cross-sect. kg End 100 Terminals/ Left or right KSA-10AB451 1.850 feed unit 5 x 16 mm 2 250 (2) Lugs/240 mm 2 Left or right KSA-25AB42 7.200 (M10 screw) Centre 250 (2) Lugs/240 mm 2 Along the run KSA-25BT42 12.00 feed unit (M10 screw) Flange 250 (2) Bars Left or right KSA-25ER4 1.700 feed unit (M10 screw) KV-KS 250 (2) KV0-25ER41001 connector N KV0-25ER41001 End 250 (2) Left or right KSB-25FA3 0.150 cover Components for changing direction (4) Type Rating Mounting Reference Weight A kg Elbows 250 (2) Edgewise KSA-25LC40 3.150 Flat upwards (1) KSA-25LP41 5.000 Flat downwards (1) KSA-25LP42 5.000 Tee 250 (2) Edgewise KSA-25TC40 4.300 Cross 250 (2) Edgewise KSA-25XC40 5.000 Fixing Device (Order in multiples of10) Bracket 250 (2) KSA-25EZ1 0.300 (1) IP 54 with sealing accessory : see page 11043/2. (2) This reference is suitable for 100 and 160 A ratings. (3) When ordering, state the required length in mm (in multiples of 5 mm) after the reference. Example : KSA-25ES4A L = 1250 mm. (4) Other components IP 54 as standard, common to versions of 3L+N+PE and 3L+PEN straight lengths. Te 11033/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 pages 11040/2 to 11040/5 Canalis KS (400 and 500 A) References Run components (IP 52/IP 54) (1) Description Rating Length Number of 3L + N + PE and 3L + PEN Weight A mm tap-offs Reference kg Straight 400 5000 10 KSA-40ED450 40.000 lengths 3000 6 KSA-40ED430 25.000 KSA-40ED450 500 5000 10 KSA-50ED450 44.500 3000 6 KSA-50ED430 28.000 500 (400) 2000 6 KSA-50ED420 20.000 1500 3 KSA-50ED415 15.900 Straight length 500 (400) 500 to 1995 KSA-50ES4A (3) 15 kg/m cut to length Fire barrier 500 (400) 1200 to 2340 KSA-50EF4A (3) 15 kg/m length Connection components and feed units (2) Description Rating Connection Mounting Unit Weight A Type/Max cross-sect. reference kg End 500 (400) Lugs/2 x 300 mm 2 Right KSA-50AB452 22.000 feed unit (M12 screw) KSA-50AB452 Left KSA-50AB462 22.000 Centre 500 (400) Lugs/2 x 300 mm 2 Along the run KSA-50BT402 39.000 feed unit (M12 screw) Flange 500 (400) Bars Left or right KSA-50ER4 4.100 feed unit (M12 screw) KV-KS 500 (400) KV0-50ER41001 connector End 500 (400) Left or right KSB-50FA2 0.440 cover Components for changing direction (2) N KV0-50ER41001 Description Rating Mounting Reference Weight A kg Elbows 500 (400) Edgewise KSA-50LC40 9.860 Flat upwards (1) KSA-50LP41 10.000 Flat downwards (1) KSA-50LP42 10.000 Tee 500 (400) Edgewise KSA-50TC40 15.000 Cross 500 (400) Edgewise KSA-50XC40 16.500 Fixing device (Order in multiples of10) Bracket 500 (400) KSA-50EZ3 0.330 11033/4 Te (1) IP 54 with sealing accessory : see page 11043/2. (2) Other run components IP 54 as standard, common to versions of 3L+N+PE and 3L+PEN straight lengths. (3) When ordering, state the required length in mm (in multiples of 5 mm) after the reference. Example : KSA-50ES4A L = 1250 mm.

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 pages 11040/2 to 11040/5 Canalis KS (630 and 800 A) References Run components (IP 52/IP 54) (1) Description Rating Length Number of 3L + N + PE and 3L + PEN Weight A mm tap-offs Reference kg Straight 630 5000 10 KSA-63ED450 58.500 lengths 3000 6 KSA-63ED430 36.200 KSA-63ED450 800 5000 10 KSA-80ED450 70.000 3000 6 KSA-80ED430 43.500 800 (630) 2000 6 KSA-80ED420 30.600 1500 3 KSA-80ED415 24.000 Straight length 800 (630) 500 to 1995 KSA-80ES4A (3) 19.600/m cut to length Fire barrier 800 (630) 1200 to 2340 KSA-80EF4A (3) 19.600/m length Connection components and feed units (2) Description Rating Connection Mounting Reference Weight A Type/Max cross-sect. kg End 800 (630) Lugs/3 x 300 mm 2 Right KSA-80AB452 36.200 feed unit (M12 screw) KSA-80AB452 Left KSA-80AB462 36.200 Centre 800 (630) Lugs/3 x 300 mm 2 Along the run KSA-80BT402 40.000 feed unit (M12 screw) Flange 800 (630) Bars Left or right KSA-80ER4 6.150 feed unit (4 x M10 screw) KV-KS 800 (630) KV0-80ER41001 connector End 800 (630) KSB-80FA2 0.510 cover Components for changing direction (2) N KV0-80ER41001 Description Rating Mounting Reference Weight A kg Elbows 800 (630) Edgewise KSA-80LC40 15.000 Flat upwards (1) KSA-80LP41 13.700 Flat downwards (1) KSA-80LP42 13.700 Tee 800 (630) Edgewise KSA-80TC40 18.240 Cross 800 (630) Edgewise KSA-80XC40 20.000 Fixing device (Order in multiples of 10) Bracket 800 (630) KSA-80EZ3 0.400 (1) IP 54 with sealing accessory : see page 11043/2. (2) Other run components IP 54 as standard, common to versions of 3L+ N + PE and 3L+ PEN straight lengths. (3) When ordering, state the required length in mm (in multiples of 5 mm) after the reference. Example : KSA-80ES4A L = 1250 mm. Te 11033/5

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11041/2 Canalis KS (100 to 800 A) IP 40 protected tap-off units for NF fuses References Tap-off unit Number of Conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS TNC IT TT TNS Tap-off TT TNS TNS IT TT TNS Tap-off scheme (2) Rating Fuse Connection Reference Reference Reference Reference A size mm 2 Weight (kg) Weight (kg) Weight (kg) Weight (kg) 25 10 x 38 4 KSA-02CF5 KSA-02CF5 KSA-02CF5 0.400 0.400 0.400 KSA-02CF5 Tap-off units with isolator and base units for fuses Number of Conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme IT (3) (2) TT, TNS (3) (4) KSA-05SF41 Rating Fuse Connection Reference Reference Reference Reference A size mm 2 Weight (kg) Weight (kg) Weight (kg) Weight (kg) 50 14 x 51 10 KSA-05SF41 KSA-05SF41 (5) KSA-05SF5 KSA-05SF41 2.500 2.500 2.500 2.500 100 22 x 58 35 KSA-10SF41 KSA-10SF41 (5) KSA-10SF5 KSA-10SF41 4.250 4.250 4.250 4.250 125 00 50 KSA-12SF41 KSA-12SF5 KSA-12SF41 4.250 4.250 4.250 160 0 70 KSA-16SF41 KSA-16SF41 (5) KSA-16SF5 KSA-16SF3 8.900 8.600 8.900 8.400 250 1 150 KSA-25SF41 KSA-25SF41 (5) KSA-25SF5 KSA-25SF3 16.700 16.700 17.000 16.000 400 2 240 KSA-40SF41 KSA-40SF41 (5) KSA-40SF5 KSA-40SF3 36.000 36.000 36.000 34.800 KSA-16SF3 630 3 2 x 120 KSA-63SF41 KSA-63SF41 (5) KSA-63SF5 KSA-63SF3 (6) 75.000 75.000 75.000 71.000 11034/2 Te Np : Neutral protected. (1) Conforming to publication IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If cross-section N is equal to the phase cross-sections. (3) For use with a breaker placed upstream or downstream of the tap-off. (4) If cross-section N is less than the phase cross-sections. (5) For use with a single phase protection device. (6) Tap-off units fixed on KSA-80 component, length 1 m.

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11041/3 Canalis KS (100 to 800 A) IP 54 dust and damp proof tap-off units for NF fuses References Tap-off unit Number of Conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS TNC IT TT TNS Tap-off TT TNS TNS IT TT TNS Tap-off scheme (2) Rating Fuse Connection Reference Reference Reference Reference A size mm 2 Weight (kg) Weight (kg) Weight (kg) Weight (kg) 25 10 x 38 4 KSE-02CF5 KSE-02CF5 KSE-02CF5 0.430 0.430 0.430 KSE-02CF5 Tap-off units with isolator and base units for fuses Number of Conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme (2) IT (4) TT, TNS (3) (4) KSE-05SF41 Rating Fuse Connection Reference Reference Reference Reference A size mm 2 Weight (kg) Weight (kg) Weight (kg) Weight (kg) 50 14 x 51 10 KSE-05SF41 KSE-05SF41 (5) KSE-05SF5 KSE-05SF41 2.600 2.600 2.600 2.600 100 22 x 58 35 KSE-10SF41 KSE-10SF41 (5) KSE-10SF5 KSE-10SF41 5.800 5.800 4.250 5.800 00 50 KSE-10SD41 KSE-10SD5 KSE-10SD41 5.000 5.000 5.000 160 0 70 KSE-16SF41 KSE-16SF41 (5) KSE-16SF5 KSE-16SF3 7.400 7.400 7.400 7.400 250 1 150 KSE-25SF41 KSE-25SF41 (5) KSE-25SF5 KSE-25SF3 18.000 18.000 18.000 17.400 KSE-25SF3 400 2 240 KSE-40SF41 KSE-40SF41 (5) KSE-40SF5 KSE-40SF3 37.000 37.000 37.000 36.200 Np : Neutral protected. (1) Conforming to publication IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If cross-section N is equal to the phase cross-sections. (3) If cross-section N is less than the phase cross-sections. (4) For use with a breaker placed upstream or downstream of the tap-off. (5) For use with a single phase protection device. Te 11034/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11041/3 Canalis KS (100 to 800 A) IP 54 dust and damp proof tap-off units for DIN and BS fuses References Tap-off units Number of conductors 3L + N + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS TNC IT TT TNS Tap-off TT TNS TNS IT TT TNS Tap-off scheme For Rating Type of Connection Reference Reference Reference fuses A fuses mm 2 Weight (kg) Weight (kg) Weight (kg) DIN 16 D01 4 KSE-02CD5 KSE-02CD5 KSE-02CD5 Neozed E14 0.450 0.450 0.450 KSE-02CG5 BS 20 BS88A1 4 KSE-02CG5 KSE-02CG5 0.350 0.350 (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. 11035/2 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11041/3 Canalis KS (100 to 800 A) IP 54 dust and damp proof tap-off units for DIN and BS fuses References Tap-off units with isolator and base units for fuses Number of conductors 3L + N + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS TNC TNC IT TT TNS Tap-off TT TNS TNC TNS IT TT TNS Tap-off scheme For Rating Type of Connection Reference Reference Reference fuses A fuses mm 2 Weight (kg) Weight (kg) Weight (kg) DIN 25 Diazed E27 6 KSE-02SD41 KSE-02SD5 KSE-02SD41 2.720 2.720 2.720 (2) 50 D02 10 KSE-05SD41 KSE-05SD5 KSE-05SD41 Neozed E18 2.600 2.600 2.600 KSE-16SD3 63 Diazed E33 16 KSE-06SD41 KSE-06SD5 KSE-06SD41 5.300 5.300 5.300 100 Size 00 50 KSE-10SD41 KSE-10SD5 KSE-10SD41 5.000 5.000 5.000 160 Size 00 50 KSE-16SD41 KSE-16SD5 KSE-16SD3 7.400 7.400 7.400 250 Size 1 150 KSE-25SF41 KSE-25SF5 KSE-25SF3 18.000 18.000 17.400 400 Size 2 240 KSE-40SF41 KSE-40SF5 KSE-40SF3 37.000 37.000 36.200 BS 30 (3) BS88A1 6 KSE-03SG41 KSE-03SG41 2.600 2.600 KSE-03SG41 60 BS88A1 or A3 35 KSE-06SG41 KSE-06SG41 5.000 5.000 160 BS88B1 or B2 70 KSE-16SG41 KSE-16SG41 7.400 7.400 (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If the neutral cross-section is equal to the phase cross-sections. (3) Do not use with scheme TNC TNC Te 11035/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11042/2 Canalis KS (100 to 800 A) Tap-off units for IP 40 protected equipment References Tap-off units for modular equipment (not supplied) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC IT TT TNS Tap-off TT TNS IT TT TNS TNS IT TT TNS Tap-off scheme (Example with circuit-breaker) (2) Rating Number Reference Reference Reference Reference A of modules Weight (kg) Weight (kg) Weight (kg) Weight (kg) KSA-02DA50010 25 4 KSA-02DA50010 KSA-02DA50010 KSA-02DA50010 KSA-02DA50010 0.500 0.500 0.500 0.500 Tap-off units with isolator Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme (Example with circuit-breaker) (2) KSA-05DA40010 For modular equipment (not supplied) Rating Number Reference Reference Reference Reference A of modules Weight (kg) Weight (kg) Weight (kg) Weight (kg) 50 7.5 KSA-05DA40010 KSA-05DA40010 KSA-05DA50010 KSA-05DA40010 2.400 2.400 2.400 2.400 100 11 KSA-10DB40030 KSA-10DB40030 KSA-10DB50030 KSA-10DB40030 5.000 5.000 5.000 5.000 For contact breakers (not supplied) With Telequick plate Reference Reference Reference Reference Type Weight (kg) Weight (kg) Weight (kg) Weight (kg) AM1-PA3030 KSA-12SU411 KSA-12SU511 KSA-12SU411 AM1-PA6040 KSA-12SU412 KSA-12SU512 11037/2 Te Np : Neutral protected. (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If the neutral cross-section is equal to the phase cross-sections.

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11042/3 Canalis KS (100 to 800 A) Tap-off units for IP 54 dust and damp proof equipment References Tap-off units with isolator for modular equipment (not supplied) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme (Example with circuit-breaker) (2) Rating Number Reference Reference Reference Reference A of modules Weight (kg) Weight (kg) Weight (kg) Weight (kg) 50 7.5 KSE-05DA4 KSE-05DA4 KSE-05DA5 KSE-05DA4 2.400 2.400 2.400 2.400 KSE-05DA4 100 7.5 KSE-10DA4 KSE-10DA4 KSE-10DA5 KSE-10DA4 3.400 3.400 3.400 3.400 Np : Neutral protected. (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If the neutral cross-section is equal to the phase cross-sections. Te 11037/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11042/2 Canalis KS (100 to 800 A) Tap-off units for IP 40 protected circuit-breakers References Tap-off units for Merlin Gerin Compact NS fixed circuit-breakers (3) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNS TNC IT TT TNS Tap-off scheme (2) With MCC type rotary handle (1) Rating Type of Reference Reference Reference Reference A circuit-breaker Weight (kg) Weight (kg) Weight (kg) Weight (kg) 100 NS 100 N, H, L KSA-16DB411 KSA-16DB411 KSA-16DB511 KSA-16DB511 9.000 9.000 9.000 9.000 160 NS 160 N, H, L KSA-16DB411 KSA-16DB411 KSA-16DB511 KSA-16DB511 9.000 9.000 9.000 9.000 KSA-16DB411 With extended rotary handle, short axis 250 NS 250 N, H, L KSA-25DB411 KSA-25DB411 KSA-25DB511 KSA-25DB511 13.500 13.500 13.500 13.500 400 NS 400 N, H, L KSA-40DB411 KSA-40DB411 KSA-40DB511 KSA-40DB511 13.500 13.500 13.500 13.500 Tap-off units with isolator for integral 18, 32 and 63 contactor-breakers (3) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme (2) KSA-02DL4 Rating Device Reference Reference Reference Reference A Weight (kg) Weight (kg) Weight (kg) Weight (kg) 18 integral 18 KSA-02DL4 KSA-02DL5 KSA-02DL4 4.000 4.000 32 integral 32 KSA-03DL4 KSA-03DL4 KSA-03DL5 KSA-03DL4 4.000 4.000 4.000 4.000 63 integral 63 KSA-06DL4 KSA-06DL5 KSA-06DL4 7.800 7.800 Np : Neutral protected. (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If the neutral cross-section is equal to the phase cross-sections. (3) Equipment not supplied. 11038/2 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 page 11042/3 Canalis KS (100 to 800 A) Tap-off units for IP 54 dust and damp proof circuit-breakers References Tap-off units for Merlin Gerin Compact NS fixed circuit-breaker (3) With extended rotary handle, short axis (1) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TT TNS IT TT TNS TNS TNC IT TT TNS Tap-off scheme Rating Type of Reference Reference Reference Reference A circuit-breaker Weight (kg) Weight (kg) Weight (kg) Weight (kg) 100 NS 100 N, H, L KSE-16DB411 KSE-16DB411 KSE-16DB511 KSE-16DB511 11.000 11.000 11.000 11.000 (2) 160 NS 160 N, H, L KSE-16DB411 KSE-16DB411 KSE-16DB511 KSE-16DB511 11.000 11.000 11.000 11.000 KSE-16DB411 250 NS 250 N, H, L KSE-25DB411 KSE-25DB411 KSE-25DB511 KSE-25DB511 13.500 13.500 13.500 13.500 400 NS 400 N, H, L KSE-40DB411 KSE-40DB411 KSE-40DB511 KSE-40DB511 13.500 13.500 13.500 13.500 Tap-off units with isolator for integral 18, 32 and 63 contactor-breakers (3) With non-adjustable handle on door, for dust and damp proof units (1) Number of conductors 3L + N + PE 3L + Np + PE 3L + PEN 3L + PE Scheme (1) Trunking TT TNS IT TT TNS TNC TNC IT TT TNS Tap-off TN TNS IT TT TNS TNC TNS IT TT TNS Tap-off scheme (2) KSE-02DL4 Rating Device Reference Reference Reference Reference A Weight (kg) Weight (kg) Weight (kg) Weight (kg) 18 integral 18 KSE-02DL4 KSE-02DL5 KSE-02DL4 4.000 4.000 32 integral 32 KSE-03DL4 KSE-03DL4 KSE-03DL5 KSE-03DL4 4.000 4.000 4.000 4.000 63 integral 63 KSE-06DL4 KSE-06DL5 KSE-06DL4 7.800 7.800 Np : Neutral protected. (1) Conforming to publications IEC 364-3-1/section 3 and UTE NF C 15-100. (2) If the neutral cross-section is equal to the phase cross-sections. (3) Equipment not supplied. Te 11038/3

Canalis KS (100 to 800 A) Dust and damp proofing accessories and additional components page 11031/7 page 11040/5 References IP 54 dust and damp proofing accessories for trunking installed edgewise Description Rating Use Reference Weight A kg Tap-off 100 to 800 1 per unused KSE-80YB2 0.080 blanking plate tap-off outlet KSE-80YB2 IP 54 dust and damp proofing accessories for trunking installed flat or vertically Sealed jointing 250 For straight lengths KSE-25YA2 1.280 sleeve (100 to 160) KSA-iiEDiii (1 per length) KSE-80YB2 For any other KSE-25YA3 1.280 length (1 per length) KSE-iiYAi 500 For any length KSE-50YA2 2.250 (400) (1 per length) 800 For any length KSE-80YA2 2.600 (630) (1 per length) Tap-off 100 to 800 1 per unused KSE-80YB2 0.080 blanking plate tap-off outlet 11043/2 Te

Canalis KS (100 to 800 A) Dust and damp proofing accessories and additional components References Additional accessories for tap-off units Description For unit For NF blade Reference Weight fuses kg Single phase KSi-05SFii 14 x 51 KSA-05EZ20 0.020 protection device (3L or 3L + N) For NF blade fuses KSi-10SFii 22 x 58 KSA-10EZ20 0.020 KSi-16SFii T0 KSA-16EZ20 0.050 KSi-25SFii T1 KSA-25EZ20 0.050 KSi-40SFii T2 KSA-40EZ20 0.100 KSi-63SFii T3 KSA-63EZ20 0.100 Description For unit Cable clamps Unit Weight Ø min. - max. reference kg Gland plate with KSA-05Siiii 8...20 mm KSA-05AZ1 0.150 cable clamps (IP 40) KSA-06Siiii 25...40 mm KSA-12AZ1 0.200 KSA-12SFiii KSA-16Siiii 30...55 mm KSA-16AZ1 0.250 KSA-25SFiii 30...70 mm KSA-40AZ1 1.100 KSA-40SFiii Cable clamp only 30...70 mm KSA-80AZ1 0.950 Gate switch KSA-05Siii to KSA-12AZ40 0.015 KSA-12Siii KSA-16Siii KSA-16AZ40 0.030 Sealing kit KSA-12AZ2 0.010 for unit end (Order in multiples of 20) Te 11043/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : pages 11033/3 to 11033/5 Canalis KS (100 to 800 A) Dimensions Trunking lengths 100, 160 and 250 A KSA-10EAiii, KSA-16EAiii and KSA-25EAiii 54 Trunking lengths 400, 500, 630 and 800 A KSA-40EDiii, KSA-50EDiii, KSA-63EDiii and KSA-80EDiii 146 146 250 1000 1000 1000 1000 750 750 1000 1000 1000 1000 250 5000 250 1000 1000 1000 1000 750 750 1000 1000 1000 1000 250 5000 a Rating (A) a 400/500 75 630/800 113 Straight lengths cut to length KSA-ii iies4a Fire barrier lengths KSA-ii iief4a (1) a (1) (1) a 1200 à 2340 Rating (A) a Rating (A) a 100 250 54 100 250 54 400 500 75 400 500 75 630 and 800 113 630 and 800 113 (1) Minimum 500, maximum 1995 (1) Minimum 600. (indicate the position of the fire barrier) 11040/2 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : pages 11033/3 to 11033/5 Canalis KS (100 to 800 A) Dimensions Feed units for 100 and 250 A trunking KSA-10AB451 KSA-25AB42 (1) (1) 60 mm minimum Cable outlet : cable gland 29 KSA-25BT42 Flange feed unit KSA-25ER4 Cable outlet. Feed units for 400 and 800 A trunking KSA-iiAB4i2 KSA-iiBT402 Ø 11 C-20 C G B F A D D1 Rating (A) A B C D D1 F G Rating (A) a a1 b 400/500 600 770 406 230 175 300 150 400/500 290 235 510 630/800 680 850 556 310 236 300 190 630/800 390 316 556 Cable outlet. Flange feed unit KSA-50ER4 KSA-80ER4 Ø 7 Ø 7 N N 290 340 370 80 80 40 16 80 80 b-20 b 212 315 390 284 112 505 400 126 170 N 390 600 170 270 126 430 280 294 45 90 105 81 143 253 61 61 49 43 Ø14 37 20 Ø 11 177 300 660 1000 170 a 290 340 370 80 80 a1 170 220 250 143 315 37 Ø14 20 210 166 260 338 290 Ø11 40 72 Te 11040/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : pages 11033/3 to 11033/5 Canalis KS (100 to 800 A) Dimensions KV-KS connector KV0-iiER41001 Rating (A) a 250 54 500 75 800 113 End covers KSB-25FA3 KSB-50FA2 KSB-80FA2 Elbows, tee and cross for 100 and 250 A trunking KSA-25LC40 KSA-25LP41 KSA-25LP42 N 165 54 N 165 250 165 250 KSA-25TC40 KSA-25XC40 N 165 N 165 165 250 a 146 2000 15 20 20 N 250 54 165 165 165 165 165 165 11040/4 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : pages 11033/3 to 11033/5 Canalis KS (100 to 800 A) Dimensions Elbows, tee and cross for 400 to 800 A trunking KSA-iiLC40 KSA-iiLP41 KSA-iiLP42 N 146 N 290 a 290 N 290 a 290 290 a 290 KSA-iiTC40 KSA-iiXC40 N a 290 290 580 290 146 N 290 290 580 146 Rating (A) a 400 500 75 630 and 800 113 a 290 290 580 Fixing brackets KSA-25EZ1 KSA-50EZ3 KSA-80EZ3 Sealing and joining kits (IP 54) KSE-25YA2 KSE-50YA2 KSE-80YA2 185 190 200 210 85 323 105 323 140 Tap-off blanking plate KSE-80YB2 155 40 40 40 50 50 36 176 50 50 36 176 50 50 36 176 80 30 8x14 115 30 8x14 152 30 8x14 95 a Rating (A) a 100 250 70 400 500 90 630 and 800 125 Te 11040/5

pages 11031/2 to 11031/7 Selection guide page 11032/2 page 11032/5 References : pages 11034/2 and 11035/2 Canalis KS (100 to 800 A) Tap-off units with/without isolator and fuse carriers Dimensions Tap-off units with/without isolator and fuse carriers KSA-02CF5 KSA-05SFii KSA-10SFii, KSA-12SFii KSA-16SFii 285 310 183 93 50 43* Ø8-20 270 50 113* 193 160 8 8 Ø25-40 50 113* 380 Ø30-55 430 130* 230 55 455 KSA-25SFii KSA-40SFii 565 415 460 90 100 430 45 200* 55 255 610 220* 63 KSA-63SFii 190 610 36 165 670 71 1000 290 63 (*) Side projection Cable outlets 11041/2 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : pages 11034/3 and 11035/3 Canalis KS (100 to 800 A) Dust and damp proof tap-off units with/without isolator and fuse carriers Dimensions Dust and damp proof tap-off units with/without isolator and fuse carriers KSE-02CF5 KSE-02CG5 KSE-02CD5 160 8 93 8 50 43* 93 8 50 90* KSE-05SFii KSE-02SDii, KSE-05SDii KSE-03SG41 KSE-10SFii, KSE-10SDii KSE-06SDii KSE-06SG41 183 195 160 8 270 50 113* 395 100 40 190 KSE-16SFii KSE-16SDii KSE-16SGii KSE-25SFii 285 415 460 90 430 130* 55 455 230 430 45 200* 255 55 KSE-40SFii KSE-63SFii 565 100 190 610 36 610 220* 63 165 670 1000 71 290 63 (*) Side projection Cable outlet Te 11041/3

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : page 11037/2 Canalis KS (100 to 800 A) Miscellaneous tap-off units with/without isolator Dimensions Tap-off units with/without isolator for modular equipment KSA-02DA50010 KSA-05DAi0010 KSA-10DBi0030 4 modules (79.5 x 47) 160 8 7,5 modules (140 x 47) 183 11 modules (205 x 47) 195 228 93 8 50 90* 56 Ø8-20 50 113* 48 270 395 100 190 40 48 Tap-off units with isolator for contact breakers KSA-12SUi11 KSA-12SUi12 Tap-off units for Merlin Gerin circuit-breaker KSA-16DBi11 KSA-25DBi11 KSA-40DBi11 Tap-off units for integral contactor-breaker KSA-02DLi, KSA-03DLi KSA-06DLi 230 255 375 188 235 453 126* 55 470 231 675 565 155* 55 582 260 15 368 15 163 590 207 257 200 215 330 110 580 250 300 368 18 163 780 275 325 400 140 230 40 500 300 195* 55 (*) Side projection. Cable outlet. 11042/2 Te

pages 11031/2 to 11031/7 page 11032/2 page 11032/5 References : page 11037/3 Canalis KS (100 to 800 A) Miscellaneous dust and damp proof tap-off units with/without isolator Dimensions Dust and damp proof tap-off units with/without isolator for modular equipment KSE-05DAi KSE-10DAi 7.5 modules (140 x 47) 7.5 modules (140 x 47) Dust and damp proof tap-off units for Merlin Gerin circuit-breaker KSE-16DBi11 KSE-25DBi11 KSE-40DBi11 Dust and damp proof tap-off units for integral contactor-breaker KSE-02DLi, KSE-03DLi KSE-06DLi 230 183 195 270 50 113* 70 395 100 190 40 52 368 15 163 368 15 163 465 147 197 590 207 257 780 275 325 200 215 368 163 18 400 140 230 40 195* 55 500 300 (*) Side projection. Cable outlets. Te 11042/3

Canalis KVA (200 to 800 A) For feeding and connections in : industry, commercial and service buildings and infrastructures Presentation 1 2 Run components Connection components and feed units 6 ratings : 200-315 - 400-500 - 630 and 800 A. 4 live aluminium conductors in fixed lengths of 4 metres or in 0.35 to 2 metre lengths as required. For connecting busbar trunking to switchboard connections, generators and transformers. Also for feeding distribution busbar trunking and for feeding feed trunking from the distribution trunking. These components are only available in copper. 1/4 Te

3 4 Components for changing direction For adapting to all the trunking runs. They are available as rigid units (elbow, tee) or flexible units. These components are only available in copper. Fixing brackets There are two types of fixing : horizontal and vertical. Te 1/5

Canalis KVA (200 to 800 A) For low density horizontal distribution in : industry, commercial and service buildings and infrastructures Presentation 1 2 Run components 6 ratings : 200-315 - 400-500 - 630 and 800 A. 4 live aluminium conductors in fixed lengths of 4 metres or in 0.35 to 2 metre lengths as required. Connection components and feed units For connecting busbar trunking to switchboard connections. These components are only available in copper. 1/6 Te

3 4 5 Components for changing direction Fixing brackets Tap-off units For adapting to all the trunking runs. They are available as rigid units (elbow, tee) and flexible units. These components are only available in copper. There are two types of fixing : horizontal and vertical. These bolted units can only be mounted at the junction of two feeder lengths (ET). They are designed to take Merlin Gerin Compact NS circuit-breakers. Te 1/7

Canalis KVA (200 to 800 A) For rising main distribution in : service buildings and infrastructures Presentation 1 Run components 6 ratings : 200-315 - 400-500 - 630 and 800 A. 4 live aluminium conductors in fixed lengths of 1, 2 or 3 metres or in 2.50 to 4 metre lengths according to the height between floors. 2 Connection components and feed units For connecting busbar trunking to switchboard connections. These components are only available in copper. 3 Components for changing direction For adapting to all the trunking runs. They are available as rigid units (elbow, tee) or flexible units. These components are only available in copper. 1/8 Te

4 Fixing brackets There are two types of fixing : horizontal and vertical. 5 Tap-off units These bolted units can only be mounted, with the power off, at the junction of two components. There are two types : single feeder and multi-feeder. Single feeder tap-off unit for Compact NS circuit-breaker. Available in 2 ratings (250 and 400 A). Multi-feeder tap-off unit : has the distribution switchboard function which will allow several feeders per floor. This distribution principle relies on the extensive Prisma range. Te 1/9

Selection : pages 11002/2 and 11002/3 pages 11003/2 and 11003/3 References : pages 11004/2 to 11004/13 pages 11005/2 to 11005/5 Canalis KVA (200 to 800 A) Description General Canalis KVA trunking is designed to feed medium power in industrial, commercial or service buildings. It can also be used to tap off directly from the joint, between two lengths, for rising main distribution or low density distribution applications. This trunking has a compact design, namely with plated conductors inside a metal enclosure. The standard range is IP 52 (IP 54 as an option). The isolated conductor bars are made of nickel plated aluminium. The range is divided into 6 ratings from 200 to 800 A. The insulation used on the conductors is halogen-free 130 C class B polyester. The trunking has : - 4 conductors for the 3-pole + neutral version (crosssection of the neutral equal to the cross-section of the phases). Recommended for TNC scheme. The metal enclosure in prelacquered galvanised sheet steel (RAL 7032) provides protection and mechanical resistance for the conductors along their entire length. Moreover, the metal enclosure is used as a protective conductor (conforming to NF C15-100) with continuity ensured at each junction along the length of the installation. As an option, Canalis KVA can be fitted with an additional copper protective conductor (cross-section equal to half the cross-section of the phase).recommended for TNS scheme. With its compact design (no free space within the trunking), Canalis KVA can be mounted horizontally, edgewise or vertically without derating the rated current Ith. Moreover, this design does not require the mounting of a fire barrier joint to pass through floors and walls. Canalis KVA is designed to be fire-resistant for up to 2 hours. Run components ET Type These are designed to feed current through horizontal or vertical runs. A joint between two lengths can be replaced by a special joint which can be used as a tap-off point. These lengths are produced in fixed lengths of 4 metres or in 0.35 m to 2 metre lengths as required. EV Type These are designed for rising main distribution. The joint between two lengths can be used as a tap-off point. These lengths are produced in fixed lengths of 1, 2 and 3 metres or in 2.50 m to 4 metre lengths as required. They should be mounted with the neutral on the left. Junction block 1 2 1 This is supplied with the ET run components and the components for changing direction. It provides an electrical and mechanical joint. When the run has a feed unit at both ends, an additional junction block must be ordered. 2 This is supplied with the EV run components. It can be ordered separately if ET components are used to replace the junction block and enable tap-off. It provides an electrical and mechanical joint as well as a tap-off point. The electrical junction is ensured by a single junction block (1 to 2 bolts per bar) which provides continuity for all the conductors. The bolt is made up of a screw and a contraction nut, the external head of which breaks when the tightening torque is reached. When the head of the nut breaks, a red washer is released, showing that the electrical junction operation has been completed successfully. For disassembly or maintenance operations, a second head is available. The recommended torque is thus 3 danm. The junction block contacts are silver-plated copper. 1/10 Te