PARAMETER LIST MICROFUSION

Similar documents
MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

Solectria Renewables Modbus Level 6 For models SGI 500XT

Solectria Renewables Modbus Level 5 For models PVI KW

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

HPVFP High Performance Full Function Vector Frequency Inverter

BACnet- MS/TP COMMUNICATION V

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

MICROFUSION SCR POWER CONTROLLERS USER S MANUAL MicroFUSION Operator s Manual Rev 2.37

H8238/MCM MODBUS POINT MAP

E50 MODBUS POINT MAP

Modular Metering System ModbusTCP Communications Manual

COMMUNICATION MODBUS PROTOCOL MFD44 NEMO-D4Le

SE-330/SE-330AU/SE-330HV PROFIBUS-DP INTERFACE

In the event of a failure, the inverter switches off and a fault code appears on the display.

PACSystems* RX3i IC695MDL765

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Mx7x. Manual. Mx7x. Modbus for Bitronics 70 Series GRID

MODBUS RS485 SERIAL PROTOCOL

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718*

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Series F4P Communications Guide

Relay Driver Overview and Applications

70 SERIES MEASUREMENT SYSTEM

Modbus communication module for TCX2: AEX-MOD

Contents. Introduction and description Package contents Device identification PM Options... 80

TAS APFC Controller / Load Managers with MOD-BUS Interface

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

Brushless DC Motor Controller Specification Assemblies 025F0248

NLG5_CAN Spec CAN definitions Bitrate: 500 kbit/s standard Frame used CAN 2.0B specifications

Model cpci-75ld1 3U. Eight (8) LVDT/RVDT-to-Digital Channels

8510 AC Spindle Drive System

Data Acquisition Modules/ Distributed IO Modules

Know your energy. Modbus Register Map EB etactica Power Bar

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

ADP1043A Evaluation Software Reference Guide EVAL-ADP1043A-GUI-RG

815PT Smart Pressure Transmitter

GS1 Parameter Summary Detailed Parameter Listings...4 9

PAM & SAM System User s Manual

Know your energy. Modbus Register Map EM etactica Power Meter

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

AC 01.2 Modbus TCP/IP

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

PowerPlex PowerPlex. DNP3 Interface Option Manual. June 15, 2010 ML0009 Document Revision C 2010 by Bitronics, LLC

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide

Redkoh Industries RK2000. Microprocessor Transformer Rectifier Control for Electrostatic Precipitators V1.40

Compact Multiprotocol I/O Module for Ethernet 8 Universal Digital Channels, Configurable as PNP Inputs or 0.5A Outputs TBEN-S1-8DXP

815LT Submersible Smart Level Transmitter

CONTENTS Project name WMHpc Revision 1.3

CET 5 Motor Protection Relay. Programming Menu Structure

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

ES-777-MV-P2_A1 03/01/10

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

NX Series Inverters. HVAC Pocket Programming Guide

Designing with STM32F3x

Addendum SmartPAC Third Party Communications Firmware

To define the procedure for operating the FGRIO-S, FGR2-IOS and I2-IOS radios in Modbus:

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

I-7088, I-7088D, M-7088 and M-7088D User Manual

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Specification GRUNER YSP 227C

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Compact IP20 Multiprotocol Ethernet I/O Station 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels FEN20-4DIP-4DXP-DIN

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Microprocessor Control Board Set Up Procedures (OR PLC)

ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters

CHAPTER 1 INTRODUCTION...

CONTROLS CS-I. MFDC/AC Inverter Weld Control

IO Slave (enclosed) FGR2-IOS-CE-U

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Inverter Drive /Vector Drive Motors & Controls

Status Indicator LED PWR LINK COL

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

75DS2 3U cpci SYNCHRO/RESOLVER or LVDT/RVDT CONVERTER

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

CT435. PC Board Mount Temperature Controller

MTY (81)

DeviceNet for Penning Gauges

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

ASCII Programmer s Guide

DEIF A/S. Description of options. Option H1, CAN open communication Basic Gen-set Controller. Description of option. Functional description

Table of Contents. HWIO-Gateway User Manual

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

HPP Laser Diode Pulser

Seren IPS DeviceNet Implementation for RF Generators

MultiComm. DNP3 Protocol Option Manual. June 15, 2010 ML0005 Document Revision C 2010 by Bitronics, LLC

PROCESS & TEMPERATURE CONTROLLERS

SERIES PM172 POWERMETERS COMMUNICATIONS. DNP Communications Protocol REFERENCE GUIDE

MultiComm & MultiComm RTH

APPENDIX APPENDIX A 1

Transcription:

MICROFUSION PARAMETER LIST MicroFUSION controllers contain nonvolatile EEPROMs, and writing too frequently to an individual parameter may wear out the EEPROM and cause the controller to fail. Control Concepts recommends allowing an average of five minutes between consecutive writes to an individual parameter within the range of 1-199, with the exception of digital setpoint commands 100-107 and the digital system command 129. Digital setpoints and digital system command may be written continually. SP 1 Feedback Type Maximum: 7 (2 for High Performance) Selections: 1 = Voltage feedforward 2 = RMS Voltage 3 = AVG Voltage 4 = RMS Current 5 = AVG Current 6 = Real Power 7 = Apparent Power SP 2 Firing Mode Maximum: 3 Default: 2 Selections: 1 = Zero Cross 2 = Phase Angle 3 = Zero Cross Transformer (ZCT) Mode SP 3 Control Loop Selections: 0 = Open Loop 1 = Closed Loop SP 4 Ramp Time Seconds Decimal Places: 0 Maximum: 300 SP 5 Slew Rate (Control Response) 00 0 SP 6 Reserved SP 7 ZCT Phase Angle to ZC Switch Threshold AC Line Cycles 5 0 Default: 20 SP 8 Full Scale Voltage Volts 5.0 Maximum: 600.0 Default: 480.0 SP 9 Full Scale Current Amps.0 Maximum: 80.0 Default: 80.0 (Set to Amp size) SP 10 Full Scale Power kw.1 58.4 Default: 115.2 (Set according to Amp size and default voltage) SP 11 Voltage Limit Volts (RMS or AVG) 4.0 Maximum: 660.0 Default: 600.0 Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 1

SP 12 Current Limit Zone 1 Amps (RMS or AVG).0 Maximum: 84.0 Default: 84.0 (Set according to 105% Amp size) SP 13 Current Limit Type Selections: 1 = RMS 2 = AVG SP 14 Current Trip Amps RMS Maximum: 360 140 (Set according to 175% Amp size, Default: 400% for zero cross) SP 15 Power Limit kw.1 66.4 76.9 (Set 105% according to Amp size Default: and default voltage) SP 16 Relay Alarm Mask 1 000_0000_0000_0000 111_1111_1111_1111 Default: 24576 = 6000 hex (0110_0000_0000_0000) 15 = TBD 14 = Heatsink Over Temp 13 = Current Trip 12 = Heatsink High Temp Warning 11 = AC Line Phase Loss 10 = Shorted SCR 9 = Power Limit 8 = Current Limit 7 = Voltage Limit 6 = Digital RUN Enable (RUN State Request) 5 = TBD 4 = 3 Phase Load Imbalance 3 = Low Output 2 = Deviation Alarm 1 = Output% High or Tap Change Up 0 = Output% Low or Tap Change Down SP 17 Reserved SP 18 Deviation Band Percent.00 00.00 SP 19 Feedback Source Maximum: 4 Selections: 1 = Internal Feedback Signal (V, I, P) 2 = Analog Setpoint 1 3 = Analog Setpoint 2 4 = Transducer Card SP 20 Over-Current Trip Retry Setting Retry count Maximum: 3 SP 21-83 Reserved SP 84 Hero Mode Enable (**Voids MFG Warranty when enabled**) (Ignore temperature alarms) Selections: 0 = OFF 1 = ON 2 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

SP 85 System Relay Mask 000_0000_0000_0000 111_1111_1111_1111 (0000_0000_0000_0000) 15 = TBD 14 = TBD 13 = TBD 12 = TBD 11 = TBD 10 = TBD 9 = TBD 8 = TBD 7 = TBD SP 86 Reserved 6 = RUN Enable (Switch terminals OPEN) 5 = Controller is in RUN State 4 = PLL Lock Loss 3 = Watchdog Timeout 2 = Memory Error 1 = Communications Error 0 = Processor Error Trap SP 87 3 Phase Load Current Imbalance Threshold % 00 [Disabled] SP 88-89 Reserved SP 90 Analog Setpoint 1 Type Default: 2 (Current) Selections: 1 = Voltage Input 2 = Current Input SP 91 Analog Setpoint 1 Lo Command V, ma -5.00 5.00 Default: 4.00 SP 92 Analog Input 1 Lo Output % (Based on full scale value).00.00 SP 93 Analog Input 1 Hi Command V, ma -5.00 5.00 Default: 20.00 SP 94 Analog Input 1 Hi Output & (Based on full scale value).00 00.00 SP 95 Analog Input 2 Type [Voltage] Selections: 1 = Voltage Input 2 = Current Input SP 96 Analog Input 2 Lo Command V, ma -5.00 5.00.00 SP 97 Analog Input 2 Lo Output % (Based on full scale value).00.00 SP 98 Analog Input 2 Hi Command V, ma -5.00 5.00 Default: 5.00 SP 99 Analog Input 2 Hi Output % (Based on full scale value).00 00.00 SP 100 Fieldbus Setpoint [RAM] NONE (counts) 64000 (see SP-115 Setpoint Resolution Maximum: Select) Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 3

SP 101 Keypad Setpoint [RAM] NONE (counts) 64000 (see SP-115 Setpoint Resolution Maximum: Select) SP 102 Setpoint 1 Source 1 Maximum: 5 NOTE: Default = 3 when digital fieldbus option is Modbus TCP, EtherNet/IP, or PROFINET Selections: 1 = Analog Input 1 2 = Analog Input 2 3 = Fieldbus Setpoint 4 = Keypad Setpoint 5 = PWM Setpoint SP 103 Setpoint 2 Source 1 Maximum: 5 NOTE: Default = 1 when digital fieldbus option is Modbus TCP, EtherNet/IP, or PROFINET. Default = 4 if Analog Setpoint 2 feature is not enabled Selections: 1 = Analog Input 1 2 = Analog Input 2 3 = Fieldbus Setpoint 4 = Keypad Setpoint 5 = PWM Setpoint SP 104 Control Setpoint Select 1 Selections: 1 = Setpoint 1 Source 2 = Setpoint 2 Source SP 105-107 Reserved SP 108 Network Timeout Setpoint NONE (counts).00 Maximum: 64000 (see SP-115 Setpoint Resolution Select) SP 109 Clear Error Latch [RAM] 0 Selections: 0 = Do Not Clear 1 = Clear the Latch Bits to 0 SP 110 Clear Fault [RAM] 0 Selections: 0 = Do Not Clear 1 = Clear the Fault State SP 111-114: Reserved SP 115 Setpoint Resolution Select ***NOTE: Locked out during RUN state Selections: 1 = Low = 10000 2 = High = 64000 SP 116 Display Auto Scroll Enable 0 Selections: 0 = Disabled 1 = Enabled SP 117 Reserved SP 118 MAC ID (CCI Bus) 0 Maximum: 63 Default: 63 SP 119 Auto Configuration 0 Selections: 0 = Disabled 1 = Enabled 4 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

SP 120-124 Reserved SP 125 Communications Heartbeat Time Seconds SP 126 IP Address HI Default: 65535 [255.255] SP 127 IP Address LO Default: 65535 [255.255] SP 128 Network Timeout Action Selections SP 129 Digital RUN/STOP [RAM] Default: See XP-3401 Selections 0 = NONE, Continue 1 = STOP, Fault Shutdown 2 = Use network timeout setpoint (SP-108) 0 = STOP 1 = RUN SP 130 Relay Normal State Selections 0 = OFF (De-energized) 1 = ON (Energized) SP 131 Sync Guard Enable (1 if SYNC-GUARD feature is enabled) Selections 0 = OFF 1 = ON SP 132 Shorted SCR Check Enable [0 for Three Phase] Selections: 0 = OFF 1 = ON SP 133 GP Digital Input Function Selections: 0 = NONE 1 = SP-104 Control Setpoint Select 2 = SP-3 Control Loop SP 134-135 Reserved SP 136 Analog Input 1 Monitor Full Scale Value.0 Maximum: 3200.0 000.0 SP 137 Analog Input 2 Monitor Full Scale Value.0 Maximum: 3200.0 000.0 SP 138-139 Reserved SP 140 Meter 1 Output Type Selections: 1 = Voltage Output 2 = Current Output Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 5

SP 141 Meter 1 Signal Select 2 Selection: 1 = Load Voltage A 2 = Load Current A 3 = Load Voltage B 4 = Load Current B 5 = Load Voltage C 6 = Load Current C 7 = Load Power 8 = 3 Phase Load Power 9 = Direct Out [SP-146] 10 = Load Resistance A 11 = Load Resistance B 12 = Load Resistance C SP 142 Meter 1 Command Lo Value %, Based on full scale values.00.00 SP 143 Meter 1 Signal Lo Output V, ma.00 0.00.00 SP 144 Meter 1 Command Hi Value, Based on Full Scale Values.00 00.00 SP 145 Meter 1 Signal HI Output V, ma.00 0.00 Default: 5.00 SP 146 Meter 1 Out Direct V, ma.00 0.00.00 \ SP 147 Meter 2 Output Type Selections: 1 = Voltage Output 2 = Current Output SP 148 Meter 2 Signal Select 2 Default: 2 Selection: 1 = Load Voltage A 2 = Load Current A 3 = Load Voltage B 4 = Load Current B 5 = Load Voltage C 6 = Load Current C 7 = Load Power 8 = 3 Phase Load Power 9 = Direct Out [SP-153] 10 = Load Resistance A 11 = Load Resistance B 12 = Load Resistance C SP 149 Meter 2 Command Lo Value, Based on Full Scale Values.00.00 SP 150 Meter 2 Signal Lo Output V, ma.00 0.00.00 SP 151 Meter 2 Command HI Value, Based on Full Scale Values.00 00.00 SP 152 Meter 2 Signal HI Output V, ma.00 0.00 Default: 5.00 6 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

SP 153 Meter 2 Out Direct V, ma.00 0.00.00 SP 154 Load Resistance Maximum (for Retransmit scaling) Ohm.00 Maximum: 650.00 Default: 50.00 SP 155 PWM Input LO Duty Cycle %.00.00 SP 161 Transducer Feedback Select 0 Selection: 1 = V1 2 = I1 3 = V2 4 = I2 5 = V3 6 = I3 7 = P1 8 = P2 9 = P3 10 = 3ph Power SP 162-199 Reserved SP 156 PWM Input LO Command Output %.00.00 SP 157 PWM Input HI Duty Cycle %.00 00.00 SP 158 PWM Input HI Command Output %.00 00.00 SP 159 Reserved SP 160 Transducer MAC ID (CCI Link Server Node) Maximum: 63 Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 7

MONITOR PARAMETERS User List, Range: 200 to 389 MP 200 Setpoint Selected 0 Note: S1 = Setpoint 1 source, S2 = Setpoint 2 source 1 = S1 Analog Input 1 2 = S1 Analog Input 2 3 = S1 Fieldbus Setpoint 4 = S1 Keypad Setpoint 5 = S1 PWM Setpoint 6 = S2 Analog Input 1 7 = S2 Analog Input 2 8 = S2 Fieldbus Setpoint 9 = S2 Keypad Setpoint 10 = S2 PWM Setpoint MP 201 PWM Setpoint % -100.00 MP 202 Analog Input 1 %, Based on full scale values -100.00 MP 203 Analog Input 1 Command Value -99999.9 Maximum: 99999.9 MP 204 Analog Input 1 Signal V, ma -99.99 Maximum: 99.99 MP 205 Analog Input 2 %, Based on Full Scale Values -100.00 MP 208 Analog Input 1 Monitor Value -9999.9 Maximum: 9999.9 MP 209 Analog Input 2 Monitor Value -9999.9 Maximum: 9999.9 MP 210 Inhibit Alarm Status 000_0000 111_1111 Representation MSB 7 = Watchdog Timeout 6 = Memory Error (Not Active) 5 = Not Used 4 = Not Used 3 = Line Phase Loss 2 = PLL Lock Loss 1 = Heatsink Over-Temp LSB 0 = Current Trip MP 211 Controller Status Maximum: 4 0 = Disabled 1 = Enabled 2 = Diagnostic 3 = Calibration 4 = Program Mode MP 212: Reserved MP 206 Analog Input 2 Command Value -99999.9 Maximum: 99999.9 MP 207 Analog Input 2 Signal V, ma -99.99 Maximum: 99.99 8 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

MP 213 Digital I/O Status 000_0000 111_1111 0 = open/not active, 1 = closed/active MSB 7 = Not Used 6 = Not Used 5 = Not Used 4 = Relay 3 = Not Used 2 = Not Used 1 = GP I/O LSB 0 = Run/Stop-Reset MP 214-217 Reserved MP 218 AC Line Phase Coded: AC Line Phasing for Phases C, B 0 = Not Determined Maximum: EE Phase Positive Negative 0 Degrees 1 9 30 Degrees 2 A 60 Degrees 3 B 90 Degrees 4 C 120 Degrees 5 D 150 Degrees 6 E MP 219 AC Line Frequency Hz.0 Maximum: 99.9 MP 220 Line Voltage A RMS Volts.0 MP 221 Load Voltage A Volts RMS or AVG.0 MP 222 Load Current A Amps RMS or AVG.0 Maximum: 9999.9 MP 223 Load Resistance A Ohm.00 9 MP 224 Heatsink Temp A C.0 MP 225 Line Voltage B RMS Volts.0 MP 226 Load Voltage B Volts RMS or AVG.0 MP 227 Load Current B Amps RMS or AVG.0 Maximum: 9999.9 MP 228 Load Resistance B Ohm.00 9 MP 229 Reserved MP 230 Line Voltage C RMS Volts.0 MP 231 Load Voltage C Volts RMS or AVG.0 MP 232 Load Current C Amps RMS or Average.0 Maximum: 9999.9 MP 233 Load Resistance C Ohm.00 9 MP 234-244 Reserved MP 245 Load Power HI (MSW) Watts or VA Maximum: 32767 Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 9

MP 246 Load Power LO (LSW) Watts or VA MP 247 Line Power Factor.00 Maximum: 9.99 MP 248 Controller State Maximum: 3 0 = STOP 1 = RUN 2 = FAULT 3 = FAULT RESET MP 249 Output Duty Cycle % % of Full ON.0 MP 250 Setpoint Reference HI (MSW) V, A, W -99 Maximum: 99 MP 251 Setpoint Reference LO (LSW) V, A, W MP 252 Feedback HI (MSW) V, A, W -99 Maximum: 99 MP 253 Feedback LO (LSW) V, A, W MP 254 Control Loop Error HI (MSW) V, A, W -99 Maximum: 99 MP 255 Control Loop Error LO (LSW) V, A, W MP 256 Warning Alarm Status 000000000 = 0 111111111 = 1023 MSB 9 = Deviation 8 = Output% High or Tap Change Up 7 = Output% Low or Tap Change Down 6 = Low Output 5 = Load Imbalance 4 = Shorted SCR 3 = Heatsink Tmp 2 = Power Limit 1 = Current Limit LSB 0 = Voltage Limit MP 257 Load Power Factor.00 Maximum: 9.99 MP 258-304: Reserved MP 305 KWh Consumption HI (MSW) (Not yet activated) KWH Maximum: 32767 MP 306 KWh Consumption LO (LSW) (Not yet activated) KWH MP 307 Power-up Count Counts MP 308 Low Power Count Counts MP 309 In Service Time HI (MSW) Hour Maximum: 32767 MP 310 In Service Time LO (LSW) Hour 10 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

MP 311-321 Reserved MP 322 USB Status 000_0000 111_1111 Representation MSB 7 = CRC or LRC Error 6 = Not Used 5 = Not Used 4 = Not Used 3 = Parity Error 2 = Framing Error 1 = Receive Buffer Overrun LSB 0 = Address received, Message Error encountered MP 323 Network Status (CCI Link) 000_0000 111_1111 Representation MSB 7 = Bus OFF State 6 = Bus Passive State 5 = Duplicate MAC ID Detected 4 = Connection Timeout 3 = Cyclic Connection Established 2 = Reserved 1 = Explicit Connection Established LSB 0 = ON Line MP 324 Slave Connection Status (CCI Link) 000_0000 111_1111 Representation MSB 7 = Connection 2 Timeout 6 = Connection 2 Cyclic or Poll 5 = Connection 2 Explicit 4 = Connection 2 Allocated/Connected 3 = Connection 1 Timeout 2 = Connection 1 Cyclic or Poll 1 = Connection 1 Explicit LSB 0 = Connection 1 Allocated/Connected MP 325 Master Connection Status (CCI Link) 000_0000 Maximum: 0000_1111 Representation MSB 7 = Not used 6 = Not used 5 = Not used 4 = Not used 3 = Connection 1 Timeout 2 = Connection 1 Cyclic or Poll 1 = Connection 1 Explicit LSB 0 = Connection 1 Allocated/Connected MP 326 Comm Status (Communications Module) 000_0000 111_1111 Representation MSB 7 = Heartbeat Timer Timout 6 = Module Not Responding = Timeout 5 = Module Reset 4 = IP Address Query 3 = Configuration Error 2 = Configuration Mode 1 = IP Address Is Set Correctly LSB 0 = Communicating (Active) MP 327 EE Calibration Bits, Stored HI (MSW) ADC Bits -32768 Maximum: 32767 MP 328 EE Calibration Bits, Stored LO (LSW) ADC Bits MP 329 Live Calibration Bits In HI (MSW) ADC Bits -32768 Maximum: 32767 MP 330 Live Calibration Bits In LO (LSW) ADC Bits MP 331 Firmware ID Maximum: 32767 Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 11

MP 332 Firmware Version.00.01 Maximum: 99.99.99 MP 333 Minor Revision (Appended to Firmware Version) 1 Maximum: 99 MP 334 Reserved MP 335 Misc Status 000_0000_0000_0000 111_1111_1111_1111 MSB 15 = Not Used 14 = Not Used 13 = Not Used 12 = Not Used 11 = Not Used 10 = Not Used 9 = Not Used 8 = Not Used 7 = Load Trace is ON, Collecting Data 6 = AC Line Trace is ON, Collecting Data 5 = Load Trace is Enabled, Waiting for Trigger 4 = AC Line Trace is Enabled, Waiting for Trigger 3 = Waiting for the Enter Key during Initialization 2 = USER Unlock, Access Code Successfully Entered 1 = Not Used LSB 0 = MFG Unlock, Access Code Successfully Entered MP 336 EEPROM Status 000_0000_0000_0000 111_1111_1111_1111 MSB 15 = Not Used 14 = Not Used 13 = EEPROM SP Definition Table update required 12 = EEPROM is write-protected 11 = Backup User SP V-table checksum failure 10 = Not Used 9 = Not Used 8 = Repair record checksum failure 7 = Error Code Record checksum failure 6 = MFG Data Table checksum failure 5 = Calibration Data Table checksum 4 = MP 337-341 Reserved failure CAL Parameter V-Table checksum failure 3 = MFG SP V-Table checksum failure 2 = User SP V-Table checksum failure 1 = Blank, Initialization required LSB 0 = Read/Write failure MP 342 AC Line Status 000_0000 111_1111 MSB 7 = Feedback ADC Timing OK 6 = Control Loop Timing OK 5 = Phase Rotation 3-2-1 (0 = Phase Rotation 1-2-3) 4 = Phase Rotation Determined (Three Phase) 3 = Not Used 2 = Line Voltage C Present 1 = Line Voltage B Present LSB 0 = Line Voltage A Present 12 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

MP 343 Load Status 000_0000 111_1111 MSB 7 = Not Used 6 = Open Load C 5 = Open Load B 4 = Open Load A 3 = Not Used 2 = Shorted SCR C 1 = Shorted SCR B LSB 0 = Shorted SCR A MP 344 Zone Status 000_0000_0000 Maximum: 0000_0001_0000 MSB 15 = Not Used 14 = Not Used 13 = Not Used 12 = Not Used 11 = Not Used 10 = Not Used 9 = Not Used 8 = Not Used 7 = Not Used 6 = Not Used 5 = Not Used 4 = Zone 1: (0 = Not at Setpoint, 1 = at Setpoint) 3 = Not Used 2 = Not Used 1 = Not Used LSB 0 = Zone 1: (0 = Normal, 1 = FAULT) MP 345 Error Latch 000_0000_0000_0000 111_1111_1111_1111 MSB 15 = (0) Reserved 14 = (0) Reserved 13 = (0) Reserved 12 = (0) Reserved 11 = (0) Reserved 10 = (0) Reserved 9 = (0) Reserved 8 = (0) Reserved 7 = (0) Reserved 6 = (0) Reserved 5 = (0) Reserved 4 = ADC/DMA Feedback Re-Sync performed 3 = AC Line Re-Sync performed 2 = AC Line Frequency check failure 1 = Phase Loss or Missing AC Line cycle detected LSB 0 = AC Line Phase Lock Loss MP 346 Alarms 000_0000_0000_0000 Maximum: 0111_1111_1111_1111 = 32767 MSB 15 = Not Used 14 = Watchdog Timeout 13 = Output% High or Tap Change Up 12 = Output% Low or Tap Change Down 11 = Line Phase Loss 10 = PLL Lock Loss 9 = Heatsink Overtemp 8 = Current Trip 7 = Deviation 6 = Low Output (at MAX Output) 5 = Load Imbalance 4 = Shorted SCR 3 = Heatsink Close to Overtemp 2 = Power Limiting 1 = Current Limiting LSB 0 = Voltage Limiting MP 347 Reserved MP 348 Network Message Error Count (CCI Link) Counts Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 13

MP 349 Firmware Update Code MP 350-369 Reserved MP 370 Network Heartbeat Timer Seconds MP 371-378: Reserved MP 379 Bootloader Version.00 Maximum: 99.99 MP 380 PGA Gain AC Line Maximum: 32 MP 381 PGA Gain Load Voltage Maximum: 32 MP 382 Load Voltage Range Maximum: 3 MP 383-384 Reserved MP 385 PGA Gain Load Current Maximum: 32 MP 386-388 Reserved MP 389 PGA Gain Message Count PGA Gain Update Message Count per AC Line 1/2 Cycle 14 MicroFUSION Parameter List Rev 2.33 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2014

SPECIAL PARAMETERS User List, Range: 3400 to 3401 XP 3400 Digital RUN/STOP Configuration Selections: 0 = 1 = 2 = Never use Digital RUN/Stop, use switch Analog use switch only, Digital use Dig Sys RUN/Stop and switch Always use Digital RUN/Stop and switch XP 3401 Digital RUN/Stop Power-Up Default Selections: 0 = STOP 1 = RUN XP 3402 Output% High Alarm Threshold %.00 00.00 XP 3403 Output% Low Alarm Threshold %.00.00 XP 3410 High/Low Out% Alarm Display Text Select Out% HIGH / OUT% LOW Maximum: 2 TAP CHANGE UP / TAP CHANGE DOWN 00.00 Control Concepts Inc., 2014 www.ccipower.com 1-800-765-2799 MicroFUSION Parameter List Rev 2.33 15