BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

Similar documents
Full Metal Variable Area Flowmeter and Counter Model BGF

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

Coriolis Mass Flow Meter Model TM

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

Magnetic Inductive Flowmeter

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Coriolis Massflowmeter

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

TMU. Coriolis Mass Flow Meter. for liquids and gas

Coriolis Massflowmeter

Coriolis Massflowmeter

N 2. Bypass Level Indicators NBK -03/ -06/ -07/ -10/ -31/ -32/ -33. Measuring length: single-part max mm over 5500 mm two-part or multipart

Level Sensors Reed Contact Chain

KFS. Flap-type flow meter. Design and range of application

Design and applications

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview

Liquid Level Switches

Metal tube variable area flowmeters for gases, liquids and steam

OPTIFLUX 5000 Technical Datasheet

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Resistance thermometers for process technology

Electromagnetic flowmeter in all metal design Model MIM

Target disk flowmeter for liquids and gases

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Ambient Conditions. Operating Conditions. Pressure

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

Density meter DWF. Device description. Device description DWF Page 1 of 22

OPTIFLUX 5000 Technical Datasheet

COMPACT-LINE. Transmitter for ph-value

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Mass Flowmeter CoriolisMaster FCM2000

OPTIFLUX 1000 Technical Datasheet

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

CombiTemp TCR6 Standard RTD temperature sensor

SM-10. Features. Variable Area Flowmeter with Sight Glass for Small Flow Volumes. Description: Application: / Indication without power supply

Mass Flowmeter CoriolisMaster FCM2000

Vortex Meter VTX2. P e

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Electronic Flow Monitor

Rotamass TI Coriolis Mass flow meter

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

2-Wire. Level Gauge BM 702

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

ABB FCB330 FCH350 Mass Flowmeter datasheet

Temperature Transmitters

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

NGR. Guided Wave Radar Level Transmitter

TIDALFLUX 2300 F Technical Datasheet

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

Indumax CLS50/CLS50D. Technical Information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level and Pressure. Product Information. Vibrating level switches

OEM radar transmitter, for aggressive media level measurement

Rotamass TI Coriolis Mass flow meter

H250 Technical Datasheet

Technical Specification FLUXUS ADM 8127B

Float Switches with Permanent Magnet For Vertical Installation Model RSM

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Certificate of Conformity

EN-2018 MAGNETIC FLOW METERS

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Electrical Temperature Measurement

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Level Switch Catalogue

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

Liquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

SITRANS P. Transmitters for level. Introduction 1/42. Application

NEW EPB DISC MILL HOLDERS

Operation. LEVEL Transmitters

VTM Local Display Unit with Frequency and Analogue Output

FLOMID FX Electromagnetic Flowmeter

Pressure and level transmitter PASCAL CV LEVEL,

FLOWave SAW-Flowmeter

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

OPTISONIC 7300 Technical Datasheet

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

4.00 ULTRASONIC ANALYZER

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

CoriolisMaster FCB330, FCB350 Coriolis Mass Flowmeter. 4-wire compact device For flow measurement of liquids and gases

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

Flow Measurement SITRANS F M

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Transcription:

Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF Special versions up to 600 bar S2 Measuring range: 10-100... 4000-40000 l/h water 0.3-3.0... 110-1100 m³/h air (20 C, 1.013 bar) ccuracy: ± 2% of full scale p max : PN 40 (option: PN 400); t max : -40... +200 C Connection: Flange DN 15... DN 80, NSI ¾"... 3" Material: stainless steel 1.4404/1.4571, PTFE ptions: O Contacts, analogue output with HRT, PROFIBUS -P, Foundation Fieldbus, counter KOBOLD companies worldwide: RGENTIN, USTRI, BELGIUM, BULGRI, CND, CHILE, CHIN, COLoMBI, CZECHI, DOMINICN REPUBLIC, EGYPT, FRNCE, GERMNY, GRET BRITIN, HUNGRY, INDI, INDONESI, ITLY, MLYSI, MEXICO, NETHERLNDS, PERU, POLND, ROMNI, SINGPORE, SOUTH KORE, SPIN, SWITZERLND, TIWN, THILND, TUNISI, turkey, US, VIETNM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com 1

Full Metal Variable rea Flow Meter and Counter Model BGF Description Inside the flow tube, there is a star guided float which works towards a spring. n annular gap is produced between the cone-shaped magnet system and the meter ring in case of flows other than zero. The position of the magnet system depends on the resulting force of all forces acting upon it. These forces comprise the flow force, a spring force acting opposite to the flow force, and the buoyancy and weight force significant for the measurements in case of vertical installation. Each position of the magnet holder corresponds to a flow value measured during calibration, which is transferred to a scale. The BGF flow meter consists of a meter tube with connections, a meter ring, and a conical magnet holder. By means of a magnet, the position of the magnet system is transferred to an encapsulated follow magnet, which has been fitted to a pointer axle. The position of a second annular follow magnet fitted on the pointer axle is transferred to the scale by means of the pointer. pplication The BGF meter is suitable for flow measurement of liquid or gaseous products in pipes. The special advantage is that it can be used for all directions of flow. It shows the current flow rate in volume or mass per unit in time. reas of application Flow measurement, dosing, monitoring, adjusting and control of liquid and gaseous products. The meter s design makes it ideal for processes under difficult and adverse operating conditions. The devices are available with additional electrical equipment for process monitoring and control. large spectrum of wetted materials Magneto-resistive signal transmission Special design for high-pressure and high-temperature applications Excellent heat tracing technology (as option) Double eddy current damping (as option) Technical data Sensor Materials: 1.4404 (316 L) / 1.4571 (316 Ti), Hastelloy C-22, PTFE other materials on request Process connection: Flanges acc. to EN 1092, SME B16.5, DIN 2512, JIS, NPT, screw pipe, connection, special connections on request Nominal pressure: PN 40, SME Cl150 / 300 (standard) (BGF-S) PN 16, SME Cl150 (standard) (BGF-P) higher pressure rates on request (max. 400 bar) Process temperature: -40 C... +150 C (BGF-S with electrical output) -40 C... +200 C (BGF-S without electrical output) -40 C... +200 C (BGF-S with option V / H / W) -40 C... +125 C (BGF-P) mbient temperature: -40 C... +80 C ccuracy Liquid/Gas: ± 2 % of full scale dditional inaccuracy by transmitter (ES): ± 0.2 % Repeatability: ± 0.8 % of full scale Schutzart: IP 65 (luminium housing) IP 67 (Stainless steel housing) Certificate and accreditation Explosion protection: BVS 03 TEX H/B 112 dvertisement Material: Electr. outputs: luminium (stove-enameled) Stainless steel (optional) inductive switch (standard) inductive switch (safety design) microswitch others on request mbient temperature: -40 C... +80 C (without switch) -40 C... +65 C (with switch) 2 www.kobold.com

Full Metal Variable rea Flow Meter and Counter Model BGF Technical data (continued) Transmitter ES with HRT -protocol ES with HRT -protocol and 2 NMUR-switches ES with HRT -protocol and 1 NMUR-switch / 1 pulse output ES with Profibus-P ES with HRT -protocol and counter module Power supply: 14-30 V DC Outputs: passive, galvanically isolated Currency: 4-20 m Binary 1 and 2: Ui =30 V, Ii =20 m, Pi = 100 mw Input Binary: Counter reset (only for ES with counter module) mbient temperature: -40 C... +70 C Certification and accreditation Explosion protection: DMT 00 TEX E 075 Type of protection: II 2G EEx ia IIC T6 dditionall options Other materials Other flange versions and sizes Certifications and certificates Display with pressure compensations against condensate build up Microswitch Inductive switches with safety design 1/08-2013 www.kobold.com 3

Full Metal Variable rea Flow Meter and Counter Model BGF Order details (example: BGF-S 15 305B H K O 00 S 1 0) Model BGF-S = stainless steel tube BGF-P = stainless steel tube, PTFE-liner Measuring range water [l/h] Measuring range air at 20 C, 1013 mbar [Nm 3 /h] Connection size Pressure stage Max. pressure loss [mbar] Code 2) flange DIN EN 1092-1 Form B1 Code 2) flange SME Class 150 RF 10-100 0.3-3.0 DN 15, (¾") PN 40 on request 15 305B H 15 202R H 16-160 0.5-4.6 DN 15, (¾") PN 40 110 15 305B I 15 202R I 25-0.7-7.0 DN 15, (¾") PN 40 110 15 305B J 15 202R J 40-400 1.0-11 DN 15, (¾") PN 40 110 15 305B K 15 202R K 60-600 1.7-17 DN 15, (¾") PN 40 120 15 305B L 15 202R L 100-1000 3.0-30 DN 15, (¾") PN 40 90 15 305B M 15 202R M 160-1600 4.0-46 DN 15, (¾") PN 40 105 15 305B N 15 202R N - 0 7.0-70 DN 15, (¾") PN 40 130 15 305B P 15 202R P 400-4000 1) 11-110 1) DN 15, (¾") PN 40 240 15 305B Q 15 202R Q 10-100 0.3-3.0 DN 25, 1" PN 40 on request 25 309B H 25 203R H 16-160 0.5-4.6 DN 25, 1" PN 40 110 25 309B I 25 203R I 25-0.7-7.0 DN 25, 1" PN 40 110 25 309B J 25 203R J 40-400 1.0-11 DN 25, 1" PN 40 110 25 309B K 25 203R K 60-600 1.7-17 DN 25, 1" PN 40 120 25 309B L 25 203R L 100-1000 3.0-30 DN 25, 1" PN 40 90 25 309B M 25 203R M 160-1600 4.0-46 DN 25, 1" PN 40 105 25 309B N 25 203R N - 0 7.0-70 DN 25, 1" PN 40 130 25 309B P 25 203R P 400-4000 1) 11-110 1) DN 25, 1" PN 40 240 25 309B Q 25 203R Q - 0 7.0-70 DN 40, 1 ½" PN 40 75 40 317B P 40 205R P 400-4000 11-110 DN 40, 1 ½" PN 40 110 40 317B Q 40 205R Q 600-6000 17-170 DN 40, 1 ½" PN 40 130 40 317B R 40 205R R 400-4000 11-110 DN 50, 2" PN 40 100 50 321B Q 50 206R Q 600-6000 17-170 DN 50, 2" PN 40 110 50 321B R 50 206R R 1000-10000 29-290 DN 50, 2" PN 40 120 50 321B S 50 206R S 1600-16000 46-460 DN 50, 2" PN 40 130 50 321B T 50 206R T 0-00 70-700 DN 50, 2" PN 40 200 50 321B U 50 206R U 1600-16000 46-460 DN 80, 3" PN 40 110 80 331B T 80 208R T 0-00 70-700 DN 80, 3" PN 40 130 80 331B U 80 208R U 4000-40000 110-1100 DN 80, 3" PN 40 200 80 331B V 80 208R V Reference conditions: water at 20 C, 1 mpas 1) Not for model BGF-P (PTFE-casing) 2) Other flange connections: Form C, N, D, JIS or Class 300 on request 4 www.kobold.com

Full Metal Variable rea Flow Meter and Counter Model BGF Continuation order details for liquids (example: BGF-S 15305B H K O 00 S 1 0) Magnet bearer Flow direction Heating 1) / Cooling Certificates Display Scale Electrical output K = PP 1) (to 80 C, from DN 50) P = PTFE (BGF-S to 150 C) (BGF-P to 125 C) S = st. steel 1) O = top to bottom L = left to right R = right to left U = bottom to top 0 = without 1 = with heating ermeto 12 mm 2 = with heating DIN-flange DN 15 / PN40 3 = with heating NSI-flange ½" Class 150 0 = without certificate 1 = Certificate of compliance with the order 2.1 2 = Certificate of compliance with the order 2.2 B = Inspection certificate with material certificate 3.1 C = Inspection certificate with material certificate 3.2 S = aluminium V = aluminium, assembled at 200 C E = st. steel H = st. steel, assembled at distance up to 200 C T = aluminium with pressure compensation W = aluminium with pressure compensation, assembled at distance up to 200 C Water 1 = %-scale 2 = measuring range Media 4 = %-scale 5 = measuring range Please specify mediadata in plain text (see below) 0 = without 1 = 1 inductive switch 2 = 2 inductive switches C = 1 microswitch D = 2 microswitches 6 = transmitter ES with HRT, EEx ia, 4-20 m, SIL 7 = transmitter ES with HRT, EEx ia, 4-20 m and 2 Namur-switches, SIL 8 = transmitter ES with HRT, EEx ia, 4-20 m, 1 Namur switch and 1 pulse output 9 = electrical transmitter ES with Profibus -P, EEx ia I = 4-20 m with HRT counter module K = electrical transmitters ES with Foundation Fieldbus 1) Not for model BGF-P (PTFE-coating) For the right design of the flowmeter we need the following data: measuring range with unit, measured media, process temperature and pressure, viscosity, operating density (liquids), norm density (gases), mechanical connection. Dimensions [mm] DN PN I. W. (aluminium) (stainless steel) 15 40 26 74 100 25 40 32 77 103 40 40 46 85 110 50 40 70 98 123 80 40 102 114 140 Dimensional deviations: +100 mm with forward advanced display 1/08-2013 www.kobold.com 5

Full Metal Variable rea Flow Meter and Counter Model BGF Dimensions [mm] Display: aluminium 165,5* 90,5 44,5 90,5 165,5* 165,5* 90,5 44,5 44,5 Display: stainless steel 81 158* Ø 196 Ø 196 68 158* Ø 196 81 81 158* 68 6 www.kobold.com 68