Photovoltaic Systems I EE 446/646

Similar documents
CHAPTER-3 Design Aspects of DC-DC Boost Converter in Solar PV System by MPPT Algorithm

Sliding Mode Control based Maximum Power Point Tracking of PV System

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by:

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

Comparative Study of P&O and InC MPPT Algorithms

Maximum Power Point Tracking for Photovoltaic Systems

In this lab you will build a photovoltaic controller that controls a single panel and optimizes its operating point driving a resistive load.

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

Proposed System Model and Simulation for Three Phase Induction Motor Operation with Single PV Panel

Development of a Fuzzy Logic based Photovoltaic Maximum Power Point Tracking Control System using Boost Converter

Photovoltaic Systems Engineering

Photovoltaic Maximum Power Point Tracking based on an Adjustable Matched Virtual Load

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

(or Climbing the Peak without Falling Off the Other Side ) Dave Edwards

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

DESIGN & SIMULATION OF LOW POWER HOME UTILITY GRID CONNECTED PV SYSTEM USING P&O METHOD

Finite Step Model Predictive Control Based Asymmetrical Source Inverter with MPPT Technique

HYBRID SOLAR SYSTEM USING MPPT ALGORITHM FOR SMART DC HOUSE

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM

OPTIMAL DIGITAL CONTROL APPROACH FOR MPPT IN PV SYSTEM

Implementation of P&O MPPT for PV System with using Buck and Buck-Boost Converters

Understanding Temperature Effects on Crystalline PV Modules

A NEW APPROACH OF MODELLING, SIMULATION OF MPPT FOR PHOTOVOLTAIC SYSTEM IN SIMULINK MODEL

Parallel or Standalone Operation of Photovoltaic Cell with MPPT to DC Load

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications.

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

A Current Sensor-less Maximum Power Point Tracking Method for PV

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

The table below gives some summary facts to the two set of data and show that they correlate to a high degree of the course of a year.

Hardware Implementation of Maximum Power Point Tracking System using Cuk and Boost Converters

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

MEASURING EFFICIENCY OF BUCK-BOOST CONVERTER USING WITH AND WITHOUT MODIFIED PERTURB AND OBSERVE (P&O) MPPT ALGORITHM OF PHOTO-VOLTAIC (PV) ARRAYS

Solar Energy Conversion Using Soft Switched Buck Boost Converter for Domestic Applications

PV System Components: Inverters and Charge Controllers. EE 495/695 Spring 2011

Microcontroller Based MPPT Buck-Boost Converter

DESIGN, SIMULATION AND REAL-TIME IMPLEMENTATION OF A MAXIMUM POWER POINT TRACKER FOR PHOTOVOLTAIC SYSTEM

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

CHAPTER 6 INPUT VOLATGE REGULATION AND EXPERIMENTAL INVESTIGATION OF NON-LINEAR DYNAMICS IN PV SYSTEM

VERY HIGH VOLTAGE BOOST CONVERTER BASED ON BOOT STRAP CAPACITORS AND BOOST INDUCTORS USED FOR PHOTOVOLTAIC APPLICATION USING MPPT

Voltage-MPPT Controller Design of Photovolatic Array System Using Fuzzy Logic Controller

Chapter-4. Fixed and Variable Step-Size Perturb Voltage MPPT Control for Photovoltaic System

A WIDE RANGE FUZZY BASED MAXIMUM POWER POINT TRACKER FOR IMPROVING THE EFFICIENCY AND SIZING OF PV SYSTEMS

PV Charger System Using A Synchronous Buck Converter

Maximum Power Point Tracking of PV System under Partial Shading Condition

A Single Switch DC-DC Converter for Photo Voltaic-Battery System

Modeling of PV Array and Performance Enhancement by MPPT Algorithm

ISSN: X Impact factor: (Volume3, Issue2) Simulation of MPPT based Multi-level CUK converter

Design and Implementation of MPPT for a PV System using Variance Inductance Method

THE DESERT KNOWLEDGE AUSTRALIA SOLAR CENTRE: HIGH VOLTAGE EFFECTS ON INVERTER PERFORMANCE.

A Double Input DC to DC Buck-Boost Converter for Low Voltage Photovoltaic/Wind Systems

Design and Simulation of a Solar Regulator Based on DC-DC Converters Using a Robust Sliding Mode Controller

Design and Development of Solar Pump using MPPT (P&O) Algorithm

Chapter-5. Adaptive Fixed Duty Cycle (AFDC) MPPT Algorithm for Photovoltaic System

International Journal of Engineering Research ISSN: & Management Technology March-2016 Volume 3, Issue-2

CHAPTER 3 PHOTOVOLTAIC SYSTEM MODEL WITH CHARGE CONTROLLERS

INCREMENTAL CONDUCTANCE BASED MPPT FOR PV SYSTEM USING BOOST AND SEPIC CONVERTER

Comparison Of DC-DC Boost Converters Using SIMULINK

Voltage Control of Hybrid Photovoltaic/ Battery Power System for Low Voltage DC Micro grid

PV Energy Utilization

A Three-Phase Grid-Connected Inverter for Photovoltaic Applications Using Fuzzy MPPT

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

[Sathya, 2(11): November, 2013] ISSN: Impact Factor: 1.852

Solar Array Maximum Powerpoint Tracker

Study and Analysis of Distributed Maximum Power Point Tracking Under Partial Shading Conditions. Vadigi Chaitanya 710ee3074

CHAPTER 4 FUZZY LOGIC BASED PHOTO VOLTAIC ENERGY SYSTEM USING SEPIC

International Journal of Scientific & Engineering Research, Volume 7, Issue 4, April ISSN

Selection of Power Converter for Stand-alone Photovoltaic System

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: ,p-ISSN: , PP

Photovoltaic Battery Charging System Based on PIC16F877A Microcontroller

MAXIMUM POWER POINT TRACKING OF PV ARRAYS UNDER PARTIAL SHADING CONDITION USING SEPIC CONVERTER

Harmonic Analysis of 1.5 kw Photovoltaic System in the Utility Grid

Simulation based study of Maximum Power Point Tracking and Frequency Regulation for Stand-alone Solar Photovoltaic Systems

Solar fed Induction Motor Drive with TIBC Converter and Voltage Multiplier Circuit

Grid Connected photovoltaic system based on Chain cell converter Using Simulink

Comparative study of maximum power point tracking methods for photovoltaic system

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Perturb and Observe Method MATLAB Simulink and Design of PV System Using Buck Boost Converter

Improvement of a MPPT Algorithm for PV Systems and Its. Experimental Validation

Figure.1. Block of PV power conversion system JCHPS Special Issue 8: June Page 89

COMPARISON OF PERTURB AND OBSERVE MPPT FOR PV SYSTEMS CONJUCTION WITH BUCK BUCK-BOOST CONVERTERS

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

CHAPTER 3 MODELLING OF PV SOLAR FARM AS STATCOM

A Survey and Simulation of DC-DC Converters using MATLAB SIMULINK & PSPICE

Boost Converter with MPPT and PWM Inverter for Photovoltaic system

Simulation and Analysis of Photovoltaic Stand-Alone Systems. Tulika Dutta Roy

Modeling of PV Interconnected Distribution System using Simulink

Simulink Based Analysis and Realization of Solar PV System

Fuzzy Logic Based MPPT for Solar PV Applications

UC Berkeley, EECS Department

Designof PV Cell Using Perturb &Observe and Fuzzy Logic Controller Based Algorithm

Load Controlled Adaptive P&O MPPT Controller PV Energy Systems

SIMULATION OF INCREMENTAL CONDUCTANCE BASED SOLAR MPPT SYSTEM

Modeling of Multi Junction Solar Cell and MPPT Methods

EE283 Electrical Measurement Laboratory Laboratory Exercise #7: Digital Counter

Tel Fax

Maximum Power Point Tracking for Photovoltaic System by Incremental Conductance Method Using Boost and Buck-Boost Converter

Transcription:

Photovoltaic Systems I EE 446/646

PV System Types & Goal Types of PV Systems: Grid-tied systems that feed power directly into the utility grid, Residential Systems (1-10kW) Commercial/industrial systems (10-250 kw) Utility systems (10 s 100 s MW) stand-alone systems that serve the load and charge batteries, perhaps with generator back-up, Applications in which the load is directly connected to the PV: case of water-pumping systems. Goal: to learn how to properly size photovoltaic systems to provide for the various types of systems above. Power delivered by a photovoltaic system will be a function of not only ambient conditions (i.e., solar intensity, spectral variations associated with overcast conditions, ambient temperature, and wind speed) but also what type of loads the photovoltaics are supplying.

Grid-Connected PV Systems (residential) If the PV supplies less than the immediate demand of the building, the building draws supplementary power from the utility grid. If the PV supplies more power than is needed, the excess is sent back onto the grid - spinning the electric meter backwards. The system is relatively simple since failure-prone batteries are not needed for back-up power, although sometimes they may be included if utility outages are problematic.

Grid-Connected PV Systems (residential) Grid-connected PV systems have a number of desirable attributes. Their relative simplicity results in high reliability; their maximum-power-tracking unit assures high PV efficiency; their potential to be integrated into the structure of the building (i.e. no additional cost to land), in some cases, materials displaced by PVs in such systems may offset some of their costs; their ability to deliver power during the middle of the day, when utility rates are highest, increases the economic value of their kilowatt-hours. On the other hand, they have to compete with the retail price of utility power.

Grid-Connected PV Systems (Commercial, and Utility Scale) Commercial/industrial electricity rates are different from residential rates. Utility scale PV systems have to compete with the electricity wholesale prices.

Stand-alone (off-grid) PV system Stand-alone PV systems are cost effective in remote locations. These systems suffer from several inefficiencies, including: battery losses, and the system requires more attention and care, the PV usually operates well off its most efficient operating point. if generator usage is to be minimized (or eliminated), those using the energy may need to modify their lifestyles.

Water pumping PV system In here, the PV is directly coupled to the load, without any batteries or major power conditioning equipment. When the sun shines, water is pumped. There is no electric energy storage, but potential energy may be stored in a tank of water up the hill for use when needed.

I-V Curve of Different loads The I V curve of a photovoltaic cell, module, or array does not by itself tell us anything about just where on that curve the system will actually be operating. This determination is a function of the load into which the PV delivers its power. Loads do have their own I-V curves: The same voltage is across both the PV and load, and the same current runs through the PV and load. the intersection point of the two curves is the operating point.

Resistive Load I-V Curve Ohm s law: V = IR or I = V/R As R increases, the intersection point moves along the PV I V curve from left to right. The value of resistance that will result in maximum power: R m = V m /I m were V m and I m are the voltage and current at the maximum power point (MPP).

Resistive Load I-V Curve With a fixed resistance the operating point slips off the MPP as the solar irradiance changes. Later, a device called a maximum power point tracker (MPPT) will be introduced, the purpose of which is to keep the PVs operating at their highest efficiency point at all times.

Problem 6.8: Example

DC motor I-V curve DC motors (such as those used in PV-water-pumping systems ) exhibit a current voltage relationship that is similar to that of a resistor. As the motor spins, it develops a voltage (back emf) that is proportional to the motor speed (ω). The voltage current relationship for a dc motor is given by V = IR + e with e = kω where R is the motor armature resistance and k is a constant.

DC motor I-V curve At start-up, while ω = 0, the current rises rapidly with increasing voltage until it is sufficient to create enough torque to break the motor loose from static friction. Once the motor starts to spin, the back emf drops the current, and thereafter I rises more slowly with increasing voltage. A dc motor runs at nearly constant speed for any given applied voltage even though the torque requirement of its load may change. Furthermore, the motor torque is proportional to armature current.

DC motor I-V curve The mismatch of operating points with the ideal MPP is apparent in the figure below. Notice that the motor doesn t have enough current to overcome static friction until insolation reaches at least 400 W/m 2. Once it starts spinning, however, it only needs about 200 W/m 2 to keep running.

Battery I-V Curve For most off-grid applications, energy is stored in batteries for use whenever it is needed. An ideal battery has an I V curve that is a vertical line (i.e., the voltage is constant for any current). A real battery has some internal resistance and is often modeled with an equivalent circuit consisting of an ideal battery of voltage V B in series with some internal resistance R i.

Battery I-V Curve During the charge cycle, V = V B + R i I with V > V B ; as the process continues, V B increases so the I V line slides to the right. During the discharge cycle, V = V B - R i I with V < V B, the slope of the I V line flips, and the I V curve moves back to the left.

Example: Hour-by-hour I V curves with three different load types: dc motor, fixed resistor, 12-V battery Fixed resistor

Maximum Power Point Tracker (MPPT) Significant efficiency gains could be realized if the operating points for resistive, dc motor, and battery loads could somehow be kept near the knee of the PV I V curves throughout the ever-changing daily conditions. Devices to do just that, called maximum power trackers (MPPTs), are available and are a standard part of many PV systems especially those that are grid-connected. The key is to be able to convert dc voltages from one level to another. A buck-boost converter is capable of raising or lowering a dc voltage from its source to whatever dc voltage is needed by the load (see next slide) The transistor switch flips on and off at a rapid rate (on the order of 20 khz) under the control of some sensing and logic circuitry.

Maximum Power Point Tracker (MPPT) When the switch is closed, the input voltage is applied across the inductor, driving current through the inductor. The load is served by the capacitor. When the switch is open, the inductor current now flows through the capacitor, the load, and the diode. With a fast enough switch and a large enough inductor and capacitor, the circuit can be designed to have nearly constant inductor current and capacitor voltage.

Maximum Power Point Tracker (MPPT) The duty cycle D (0 < D < 1) of the switch is the fraction of the time that the switch is closed (see figure below). The variation in the fraction of time the switch is in one state or the other is referred to as pulse-width modulation (PWM). Over a complete cycle, the energy flow into and out of the inductor must be equal this results in the following relation between the input and output voltages:

Maximum Power Point Tracker (MPPT) For D = 0.5, the output voltage is the same as the input voltage. For D = 0.67, the output voltage is double the input voltage, For D = 0.33, the output voltage is half the input voltage An actual MPP tracker needs some way for the dc-to-dc converter to know the proper duty cycle to provide at any given instant. This can be done with a microprocessor that periodically varies the duty cycle up and down a bit while monitoring the output power to see whether any improvement can be achieved. One way to visualize the impact of the MPPT is to redraw the I V curves using D as a parameter. For the MPPT s output voltage and current, one goes up and the other goes down compared with the original PV I V curve (see next slide).

Maximum Power Point Tracker (MPPT)

MPPT Techniques Most common among many methods: Perturb-and-observe (hill climbing) Incremental conductance method

Example (Refer to Problem 5.13) Module voltage and current at maximum power: V = 49.2 V, I = 1.78 A, NOCT = 45 deg., Power temp. coeff. = -.25%. 14/49.2 = 0.284 = D/(1-D). Hence D = 0.284/1.284 = 0.222 or 22.2%. Current delivered to battery: I = 87.5/14 = 6.25 A Cell temp. = 25 +(45-20)x1/0.8 = 56.25 deg. Module maximum power = 87.5*(1-0.0025(56.25-25))= 80.7 W. Battery current: I = 80.7/14 = 5.76 A