Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

Similar documents
FSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids

FSM4000 Electromagnetic Flowmeter. The all-purpose flowmeter for conductive fluids

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

JUMO flowtrans MAG S01

OPTIFLUX 5000 Technical Datasheet

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

FieldIT Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE) with Pulsed DC Magnetic Field Excitation

Electro-Magnetic Flowmeters COPA-XE

OPTIFLUX 5000 Technical Datasheet

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Ambient Conditions. Operating Conditions. Pressure

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

FLOMID FX Electromagnetic Flowmeter

OPTIFLUX 1000 Technical Datasheet

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

HygienicMaster FEH500 Electromagnetic Flowmeter. A first-class choice for all hygienic applications

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Magnetic-Inductive flow Meter fmi

Mass Flowmeter CoriolisMaster FCM2000

Electromagnetic Flow Transmitter

JUMO flowtrans MAG H01

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

OPTIMASS 1000 Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet

ProcessMaster FEP610, HygienicMaster FEH610 Electromagnetic flowmeter

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Mass Flowmeter CoriolisMaster FCM2000

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

BATCHFLUX 5500 C Technical Datasheet

WATERFLUX 3070 Technical Datasheet

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

INLINE flowmeter for continuous flow measurement

BATCHFLUX and BATCHCONTROL

Coriolis Massflowmeter

ProcessMaster FEP300 Electromagnetic Flowmeter. The process industry's first choice

Electromagnetic Flowmeter FSM4000

ProcessMaster FEP500 Electromagnetic Flowmeter. The process industry's first choice. Maximum measuring accuracy Maximum measuring error: 0.

INLINE flowmeter for continuous flow measurement

Electromagnetic Flowmeter FSM4000

INSERTION paddle wheel flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Resistance thermometers for process technology

FXF2000 (COPA-XF) Electromagnetic Flowmeter. All in one -Flowmeter. With pulsed DC field excitation in a compact design

Electromagnetic Flow Measuring System promag 33

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

ProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice

TMU. Coriolis Mass Flow Meter. for liquids and gas

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Technical Information Proline Promag 10P

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

Design and applications

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Electromagnetic Flow Measuring System promag 35

Target disk flowmeter for liquids and gases

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Coriolis Massflowmeter

EN-2018 MAGNETIC FLOW METERS

OPTIFLUX 2000 Technical Datasheet

FLOWave SAW-Flowmeter

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

Digital flow ELEMENT transmitter for continuous flow measurement

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Proline Promag 55S. Technical Information

Digital flow ELEMENT transmitter for continuous flow measurement

IFC 010 Signal Converter

Coriolis Mass Flow Measuring System promass 40 E

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

ABB FCB330 FCH350 Mass Flowmeter datasheet

The transducer component converts the measured signal and displays the actual value.

Advanced instrumentation solutions crafted with highest precision

Proline Promag 55S. Technical Information

-MIL: Instrument Overview N [1/8-4 ] lowmeter Primary with ie ast Housing, langed, Wafer esign 10m max Model MG-X OP-X OP-X Remote Version onver

Proline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

KFS. Flap-type flow meter. Design and range of application

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

Proline Promag 50W, 53W

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Electromagnetic Flowmeter Comet F

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Digital conductivity transmitter

Electromagnetic flowmeters and switches DWM 1000/2000

8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Technical Information Proline Promag 55S

Full Metal Variable Area Flowmeter and Counter Model BGF

Digital flowmeter for continuous flow measurement

Magnetic Inductive Flowmeter

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

Transcription:

Contents Data Sheet D184S75U2 Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) The Electromagnetic Flowmeter (EMF) can be used to accurately measure the flowrate of liquids which have an electrical conductivity greater than 5 µs/cm (2 µs/cm for demineralized water). The COP-XE is a flow measurement system in a Compact Design. The MG-XE flow measurement system consists of a flowmeter primary and a remote mounted converter Flowmeter primary for hygienic processes - The basic flowmeter body is installed using threaded adapters which are matched to the respective pipeline connections. The following connections are available: - Weld stubs - Food industry fittings per DIN 11851 - Tri-Clamp - Wafer and fixed flange designs - Certificates EHEDG, FML, 3 Flowmeter primary for the process industry and water/waste water - Flange and wafer designs - DVGW Test Report - Certifiable for cold and waste water and fluids other than water Converter - Communication PROFIBUS DP, HRT-Protocol, FOUNDTION Fieldbus, PROFIBUS P - Pulse output, configurable (active/passive) - Data secured in a plug-in EEPROM - Graphic display - Self-monitoring functions - Comprehensive test and simulation functions Intelligent Compact and Effective

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Contents 1 FXE4 (COP-XE): Overview, Flowmeter Primary and Converter Designs:...3 2 FXE4 (MG-XE): Overview, Flowmeter Primary and Converter Designs...4 3 General information...5 3.1 Measuring ccuracy...5 3.2 Grounding...5 3.3 Installation Requirements...5 3.4 Flowmeter Sizes, Pressure Ratings, Flow Range...7 3.5 Flowrate nomograph...8 3.6 pproved EMF for custody transfer...9 4 Specifications:...1 4.1 Model DE41F, DE41W, DE43F, DE43W...1 4.2 Model DE 21, DE21F, DE23, DE23F...31 5 Transmitter...47 5.1 Specifications:...47 5.2 Housing Variants...47 5.3 In- / Outputs...48 5.4 Digital Communication...49 5.5 Converter scale drawing FXE 4-E4 (MG-XE)...58 6 Ordering Information Wafer ccessories (Table H)...61 7 Ordering Information Flowmeter Primary Simulator FXC 4...62 2

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 1 FXE4 (COP-XE): Overview, Flowmeter Primary and Converter Designs: Housing Material luminum Housing Series 4 Stainless Steel Housing Series 2 Flowmeter Primary Fixed Flange Wafer Design Fixed Flange Wafer Design Variable Connections Model Number DE43F DE43W DE23F DE23W DE23-R,-S,-T,-E ccuracy.5 % of rate, Optional.25% of rate DN PN DN PN DN PN DN PN DN PN Wafer Design - 3... 1 16-3... 1 1... 4 - Flange DIN 251/ EN 192-1 3... 1 1... 4-3... 1 1... 4 - - Flange SME B16.5 / B16.47 1/8... 4" CL 15... 3-1/8... 4" CL 15...3 - - - - - - 3... 1 1... 4 Food Ind. Fitting DIN 11851 (1/1... 4") - - - - 3... 1 1... 4 Weld stubs (1/1... 4") - - - - 3... 1 1... 4 Tri-Clamp per DIN 32676 (1/1... 4") - - - - 3... 1 1... 4 Tri-Clamp per SME BPE (1/1... 4") - - - - 3... 25 1 External threads ISO 228 (1/1... 1") Hard/soft rubber PTFE, PF (DN 3... 8) Liner PF PTFE (DN 1... 1) PF (vacuum tight) PF (vacuum tight) PF (vacuum tight) Conductivity > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) Electrodes SS 1.4571[316Ti], 1.4539, Hastelloy B2/C4, Platinum-Iridium, Tantalum, Titanium Process Connection Material Steel, 1.4571[316Ti] - 1.4571 [316Ti] - 1.444 [316L] Protection Class IP 67 IP 67 IP 67 IP 67 IP 67 Fluid Temperature * pprovals EEx Design Certifiable Press. Equip. Dir. 97/23/EG CRN ( Canadian Registration Number) Certificates Converter Supply Power Current Output Pulse Output Ext. Zero Return Ext. Totalizer Reset Forward/Reverse Flow Metering Empty Pipe Detector Self Monitor Local Display / Totalization Housing Communication -25... +13 C -13... +266 F -25... +13 C -13... +266 F -25... +13 C -13... +266 F -25... +13 C -13... +266 F TÜV 97, TEX 1173X (see separate data sheet) Cold- and Waste Water, Liquids other than Water With Conformity Evaluation per Category III, Fluid Group 1 Without pproval pproval Upon Request - - - - *) -25 C if the process connection is made of stainless steel / -1 C if the process connection is made of steel 1) Weld stubs, 2) Tri-Clamp, 3) Food Ind. Fittings, 4) External Threads C 1-23 V (-15/+1 %) / C 16.8-26.4 V / DC 16.8-31.2 V /2-1 m, -5 m, /4-2 m, /4-1/12-2 m ctive 24 V DC pulse or passive optocoupler Optocoupler input Optocoupler input Signal over optocoupler output from DN 1, Signal over optocoupler output yes yes Converter housing made of luminum (standard), converter made of stainless steel (option) PROFIBUS DP, PROFIBUS P, HRT-Protocol, FOUNDTION Fieldbus, SCII-Protocol (RS485) -25... +13 C -13... +266 F 3, EHEDG (Cleanability) 3

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 2 FXE4 (MG-XE): Overview, Flowmeter Primary and Converter Designs Housing Material luminum Housing Series 4 Stainless Steel Housing Series 2 Flowmeter Primary Fixed Flange Wafer Design Fixed Flange Wafer Design Variable Connections Model Number DE41F DE41W DE21F DE21W DE21-R,-S,-T,-E ccuracy.5 % of rate, Optional,25 % of rate DN PN DN PN DN PN DN PN DN PN Wafer Design - 3... 1 16-3... 1 1... 4 - Flange DIN 251/ EN 192-1 3... 1 1... 4-3... 1 1... 4 - - Flange SME B16.5 / B16.47 1/8... 4" CL 15... 3-1/8... 4" CL 15... 3 - - Food Ind. Fitting DIN 11851 Weld stubs Tri-Clamp per DIN 32676 Tri-Clamp per SME 32676 External threads ISO 228 Liner Conductivity - - - - 3... 1 (1/1... 4") - - - - 3... 1 (1/1... 4") 1... 4 1... 4 - - - - 3... 1 (1/1... 4") 1... 4 - - - - 3... 1 1... 4 (1/1... 4") - - - - 3... 25 1 (1/1... 1") Hard/soft rubber PF (DN 3... 8) PTFE, PF PTFE (DN 1... 1) PF (vacuum tight) PF (vacuum tight) PF (vacuum tight) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) > 5 µs/cm (2 µs/cm for demineralized water) Electrodes SS 1.4571[316Ti], 1.4539, Hastelloy B3/C4, Platinum-Iridium, Tantalum, Titanium Process Connection Material Steel, 1.4571[316Ti] - 1.4571 [316Ti] - 1.444 [316L] IP 67 IP 67 IP 67 IP 67 IP 67 Protection Class IP 68 (Option) IP 68 (Option) IP 68 (Option) IP 68 (Option) IP 68 (Option) -25... +13 C -25... +13 C -25... +13 C -25... +13 C -25... +13 C Fluid Temperature * -13... +266 F -13... +266 F -13... +266 F -13... +266 F -13... +266 F pprovals EEx Design Certifiable Press. Equip. Dir. 97/23/EG CRN ( Canadian Registration Number) Certificates Converter Supply Power Current Output Pulse Output Ext. Zero Return ext. Totalizer Reset Forward/Reverse Flow Metering Empty Pipe Detector Self Monitor Local Display / Totalization Housing Communication TÜV 97, TEX 1173X (see separate data sheet) Cold- and Waste Water, Liquids other than Water With Conformity Evaluation per Category III, Fluid Group 1 Without pproval pproval Upon Request - - - - C 1-23 V (-15/+1 %) / C 16.8-26.4 V / DC 16.8-31.2 V /2-1m, -5 m, /4-2 m, /4-1/12-2 m ctive 24 V DC pulse or passive optocoupler Optocoupler input Optocoupler input Signal over optocoupler output from DN 1, Signal over optocoupler output yes yes Field mount housing, Panel mount housing, Rail mount housing PROFIBUS DP, PROFIBUS P, HRT-Protocol, FOUNDTION Fieldbus, SCII-Protocol (RS485) *) -25 C if the process connection is made of stainless steel / -1 C if the process connection is made of steel 1) Weld stubs, 2) Tri-Clamp, 3) Food Ind. Fittings, 4) External Threads 3, EHEDG (Cleanability) 4

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Change from one to two columns 3 General information 3.1 Measuring ccuracy 3.1.1 Reference Conditions per EN 2914 Fluid Temperatures mbient Temperature Supply Power 2 C (68 F) ± 2 K 2 C (68 F) ± 2 K Line voltage per name plate UN ± 1 % and Frequency f ± 1 % Installation Conditions - Upstream >1xDN straight section - Downstream >5xDN straight section Warm Up Phase 3 min 3.1.2 Maximum Measurement error Pulse Output (Standard Calibration;.5% of rate): - Q>.7 Range max ±.5 % of rate - Q<.7 Range max ±.35 Range max Range max = maximum flowrate for the flowmeter size 1 m/s Pulse Output (Optional Calibration;.25 % of rate): - Q>.14 Range max ±.25 % of rate - Q<.14 Range max ±.35 Range max Range max = maximum flowrate for the flowmeter size 1 m/s nalog Output Effects Same as pulse output plus ±.1 % of rate. Y 6 5 4 3 2 1 2 4 6 7 8 1 14 2 4 6 8 1 %,5% v. M.,25% v. M. Q Q max DN 3.2 Grounding The grounding of the flowmeter primary is essential for both safety reasons, and to ensure trouble-free operation of the electromagnetic flowmeter. The ground screws on the flowmeter primary are to be brought to ground potential. For technical reasons, this potential should be identical to the potential of the metering fluid, if possible. For plastic or insulated lined pipelines, the fluid is grounded by installing ground plates. When there are stray currents present in the pipeline, a ground plate is recommended on both ends of the meter primary. To comply with the EMC- and Low Voltage Regulations the connection box/converter must be grounded in addition to the meter tube of the flowmeter primary. 3.3 Installation Requirements The following points must be observed for the installation: The meter tube must always be completely full. The flow direction must correspond to the identification if present. The maximum torque for all flange connections must be complied with. The devices must be installed without mechanical tension (torsion, bending). Flanged/wafer design flowmeters with coplanar counter flanges may only be installed with suitable seals. Use flange seals made from a compatible material for the fluid and fluid temperatures. Seals must not extend into the flow area since possible turbulence could influence the device accuracy. The pipeline may not exert any unallowable forces and torques on the device. Do not remove the plugs in the cable connectors until you are ready to install the electrical cable. Install the separate converter (MG-XE) at a largely vibrationfree location. Do not expose the converter to direct sunlight or provide for appropriate sun protection where necessary.,2,4,6,8 1 2 4 6 8 1 X Fig. 1 Y ccuracy ± of rate in [%] X Flow velocity v in [m/s] G6 5

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 3.3.1 Electrode axis Electrode axis (1) should be horizontal if at all possible or no more that 45 from horizontal. 3.3.4 Horizontal connections Meter tube must always be completely full. Provide for a slight incline of the connection for degassing. 3 max. 45 G38 Fig. 5 Fig. 2 3.3.2 In- and outlet pipe sections 1 G41 3.3.5 Free inlet or outlet Do not install the flowmeter at the highest point or in the drainingoff side of the pipeline, flowmeter runs empty, air bubbles can form (1). Provide for a siphon fluid intake for free inlets or outlets so that the pipeline is always full (2). Straight inlet section 3 x DN Straight outlet section 2 x DN DN = Flowmeter primary size Notice: For devices subject to calibration for commercial use, special conditions apply, see chapter "pproved EMF for custody transfer". Do not install fittings, manifolds, valves etc. directly in front of the meter tube (1). Butterfly valves must be installed so that the valve plate does not extend into the flowmeter primary. Valves or other turn-off components should be installed in the outlet pipe section (2). For compliance with the measuring accuracy, observe the inlet and outlet pipe sections. Fig. 6 1 3.3.6 Strongly contaminated fluids G4 For strongly contaminated fluids, a bypass connection according to the figure is recommended so that operation of the system can continue to run without interruption the during the mechanical cleaning. 2 1 2 3xDN 2xDN G37 Fig. 3 3.3.3 Vertical connections Vertical installation for measurement of abrasive fluids, flow preferably from below to above. Fig. 7 3.3.7 Installation in the vicinity of pumps G42 For flowmeter primaries which are to be installed in the vicinity of pumps or other vibration generating equip-ment, the utilization of mechanical snubbers is advantageous. G39 Fig. 4 G43 Fig. 8 6

Change from one to two columns Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 3.3.8 Installation in larger size pipelines Determine the arising pressure loss for use of flanged reducers (1): 1. Calculate the diameter ratio d/d. 2. Determine the flow velocity from the flow range nomograph (Fig. 1). 3. Read the pressure drop on the Y-axis in Fig. 1. Nomograph for pressure drop determinations For adaptor with α/2 = 8 Fig. 9 d v Δp D = Inside diameter of the flowmeter = Flow velocity [m/s] = Pressure drop [mbar] = Inside diameter of the pipeline Change from one to two columns 3.4 Flowmeter Sizes, Pressure Ratings, Flow Range Fig. 1 Meter Size 3 4 6 8 1 15 2 25 32 4 5 65 8 1 125 15 2 25 3 35 4 45 5 6 7 8 9 1 1/1 5/32 1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 1 12 14 16 18 2 24 28 32 36 4 Std. Press. Rating PN 4 4 4 4 4 4 4 4 4 4 4 4 4 16 16 16 1/16 1/16 1/16 1/16 1/16 1/16 1 1 1 1 1 1 Min. Flow Range Flow Velocity.5 m/s.2.4 1 1.5 2.25 5. 7.5 1 2 3 3 6 9 12 21 3 54 9 12 165 225 3 33 48 66 9 12 135 l/min l/min l/min l/min l/min l/min l/min l/min l/min l/min.1.1.3.4.6 1.3 2. 2.6 5.3 7.9 13 26 4 53 92 132 238 396 528 726 991 1321 1453 2113 296 3963 5283 5944 Max. Flow Range Flow Velocity 1 m/s 4 8 2 3 45 1 15 2 4 6 6 12 18 24 42 6 18 18 24 33 45 6 66 96 132 18 24 27 l/min l/min l/min l/min l/min l/min l/min l/min l/min l/min 1.1 2.1 5.3 7.9 12 36 4 53 16 159 264 528 793 157 1849 2642 4755 7925 1567 14529 19813 26417 2959 338 58118 79252 15669 118877 7

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) Flanged design and pressure ratings Meter Size Flange 1) Material PN DGRL 3... 25 (1/1... 1") DIN SME JIS SS1.4571[316Ti] or steel 4 bar CL15, CL3 1 bar SEP rt.3 bs.3 32 (1 1/4") 4 (1 1/2") 5 (2") 65 (2 1/2") 8 (3") 1 (4") 125 (5") 15 (6") 2 (8") 25 (1") 3 (12") 35... 6 (14... 24") 7... 1 (28... 4") DIN SME JIS DIN SME JIS DIN SME JIS DIN SME JIS DIN SME JIS DIN SME JIS DIN SME DIN SME DIN SME DIN SME DIN SME DIN SME DIN SME SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel 4 bar CL15, CL3 1 bar 4 bar CL15, CL3 1 bar 4 bar CL15, CL3 1 bar 16, 4 bar CL15, CL3 1 bar 4 bar CL15, CL3 1 bar 16, 4 bar CL15, CL3 1 bar 16, 4 bar CL15, CL3 16, 4 bar CL15, CL3 SS1.4571[316Ti] 1, 16, 25, 4 bar or steel CL15, CL3 SS1.4571[316Ti] 1, 16, 25, 4 bar or steel CL15, CL3 SS1.4571[316Ti] 1, 16, 25, 4 bar or steel CL15, CL3 SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel 1, 16, 25 bar CL15 1, 16, 25 bar CL15 1) Connection dimensions for flange according to DIN251 / EN192-1 or SME or JIS respectively. Selectively with or without conformity evaluation per Category III, Module B1+D, Fluid Group 1 Flowrange nomograph DN 3... 1 (1/1... 4") D184S75U2 3.5 Flowrate nomograph The volumetric flowrate is a function of both the flow velocity and the flowmeter size. The flow range nomograph shows the flowrates which can be metered with a specific flowmeter size and also which flowmeter sizes are suitable for a specific flowrate. Example: Flowrate = 7 (maximum value = flow range end value). Suitable are flowmeter primary sizes DN 2 : 3/4 to DN 65 : 2-1/2 for flow velocities between.5 and 1 m/s. Fig. 11 8

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 3.6 pproved EMF for custody transfer pprovals The design of the measurement instrument Electromagnetic volume flowrate totalizer with electrical counter has been approved by the National Institute for Science and Technology (Physikalisch- Technischen Bundesanstalt) in Braunschweig, Germany. The following approvals have been granted for the volume flowrate totalizer which consists of a flowmeter primary and a converter: 6.221 87.12 5.721 87.5 Electromagnetic volume flowrate totalizer with a Class and B electrical counter for cold water and waste water Electromagnetic volume flowrate totalizer with electrical counter for liquids other than water ppendix (EO6) or ppendix 5 (EO5) of the certification regulations of 1988 apply to the electromagnetic volume flowrate totalizer with electrical counter. Certification The electromagnetic volume flowrate totalizer is certified on the test stands in Göttingen, Germany which have been approved for certification calibrations. fter the calibration has been completed, the parameters which impact the certification regulations, can only be changed in the presence of a certification agent. 3.6.1 pproved flowmeter sizes for cold water and waste water DN 25 32 4 4 65 8 1 125 15 25 3 35 4 5 6 7 8 9 1 Min. llow. Flow Range End Value (approx. 2 m/s) 2,4 5 9 14 24 36 56 84 128 22 36 5 7 9 142 2 28 36 46 56 Max. llow. Flow Range End Value (approx. 1 m/s) 12 25 45 7 12 18 28 42 64 11 18 25 35 45 71 1 14 18 23 28 3.6.2 pproved flowmeter sizes for liquids other than water and chemical fluids Flowmeter Size and Maximum llowable Flowrates DN Q max Liter/min 25 32 4 5 65 8 1 15 Selectively Selectively Selectively Selectively Selectively Selectively Selectively Selectively 6... 2 1... 4 15... 75 25... 1 4... 2 7... 3 9... 45 2... 1 In steps of In steps of In steps of In steps of In steps of In steps of In steps of In steps of Minimum Flowrates and Fluids DN Minimum Flowrate Liter Fluid 25 32 4 5 65 8 1 15 2 2 2 2 5 5 2 2 Beer Beer Beer, Milk Beer, Wort Milk, Wort, Beer Milk, Wort, Beer Brine, Wort Brine 1 2 5 5 1 1 1 5 Min.flow range:approx. 2.5 m/s. Max. flow range approx. 1 m/s. The actual flow ranges must be in accord with the values listed in the tables. Subsequent range changes require a new calibration on an agency certified test stand. 3.6.3 Installation requirements for volume flowrate totalizers The following installation requirements are to be observed in each case: For flow metering in one flow direction: Cold/Waste Water In front of flowmeter primary fter flowmeter primary 5 x DN 2 x DN Other Fluids (other than water) 1 x DN 5 x DN For flow metering in both flow directions: Cold/Waste Water In front of flowmeter primary fter flowmeter primary 5 x DN 5 x DN Other Fluids (other than water) 1 x DN 1 x DN 8 D d 5xDN(1xDN) 2 x DN (5 x DN) 5xDN(1xDN) G1 Fig. 12 9

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 4 Specifications: 4.1 Model DE41F, DE41W, DE43F, DE43W E ich 4.1.1 General specifications Min. allow. Pressure as a function of Fluid Temperature Liner Hard rubber Soft rubber PTFE KTW approved PF 3... 1 Meter Size POperation mbar abs. at T Operation * 15... 25 (1/2... 1") < 9 C (194 F) 3... 1 < 9 C (194 F) (12... 4") 5... 25 < 7 C (158 F) (2... 1") 3... 1 < 7 C (158 F) (12... 4") 1... 6 27 < 2 C (68 F) (3/8... 24") 4 < 1 C (212 F) 5 < 13 C (266 F) < 13 C (266 F) (1/1... 4") * Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table Maximum llowable Cleaning Temperature. Liquid-cleaning PTFE, PF 14 C (284 F) 6 25 C (77 F) f the ambient temperature is > 25 C, then the difference must be subtracted from the max. cleaning temperature. T max - Δ C. Δ C = T mb. - 25 C). Min. llowable mbient Temperature as a function of Fluid Temperature For flowmeters with carbon steel flangers Fig. 13-1 14 Y 6 [ C] 14 [ F] 25 77 32-1 +14 5 122 For flowmeter with stainless steel flangers Y 6 [ C] 14 [ F] -25-13 25 77 32-25 -13 5 122 Fig. 14 Y = mbient temperature C/ F X = Fluid temperature C/ F Temperature range for COP-XE ------ Temperature range for MG-XE X 13 [ C] 266 [ F] X 13 [ C] 266 [ F] G378 G379 Notes regarding min./max. measuring temperature Liner Flange material min. temp max. temp Hard-rubber steel -1 C (14 F) 9 C (194 F) Hard-rubber stainless steel -15 C (5 F) 9 C (194 F) 1.4571 Soft-rubber steel -1 C (14 F) 7 C (158 F) Soft-rubber stainless steel -15 C (5 F) 7 C (158 F) 1.4571 PTFE / PF steel -1 C (14 F) 13 C (266 F) PTFE / PF stainless steel 1.4571-25 C (-13 F) 13 C (266 F) Materials, Flowmeter Primary Part Standard Options Liner PTFE, PF, hard rubber, soft rubber Signal and ground electrodes for Hast. B-3 (2.46), Hast. C-4 (2.461), - Hard rubber, soft rubber SS 1.4571 [316Ti] Titanium, Tantalum, Platinum-Iridium, 1.4539 [94L] - PTFE, PF Hast. C-4 (2.461) SS1.4571[316Ti] Hast. B-3 (2.46) Titanium, Tantalum, Platinum-Iridium, 1.4539 [94L] Ground plate SS 1.4571 [316Ti] Upon request Protection plate SS 1.4571 [316Ti] Upon request Process Connection Materials Part Standard Options Flange DN 3... 15 (1/1... ½") DN 2... 4 (3/4... 16") DN 45... 1 (18... 4") SS 1.4571 [316Ti] (standard) Steel (galvanized) Steel (painted) Max. llowable-cleaning Temperature CIP-Cleaning Liner T max T maxminutes T mb. Steam-cleaning PTFE, PF 15 C (32 F) 6 25 C (77 F) SS1.4571- [316Ti] SS1.4571- [316Ti] Part Standard Options Housing DN 3... 4(1/1... 16") Two-piece cast aluminum housing, painted, paint coat 6 µm thick, RL 92 DN 45... 1 (18... 4") Welded steel construction, painted, paint coat 6 µm thick, RL 92 Connection box Cast alum., painted, 6 µm thick, frame: dark gray, RL712, cover: light gray, RL 92 Meter tube SS 1.431 [34] PG-Connector Polyamide Storage Temperature -2 C (-4 F)... 7 C (158 F) Protection Class per EN 6529 IP 67 IP 68 (only for MG-XE flowmeter primary) Pipeline Vibration Following EN 668-2-6 The following applies for compact design FXE4 (COP-XE): In the range of 1-55 Hz max..15 mm deflection In the range of 55-15 Hz max. 2 g acceleration The following applies for separate converter (MG-XE): Converter In the range of 1-55 Hz max..15 mm deflection Flowmeter primary In the range of 1-55 Hz max..15 mm deflection In the range of 55-15 Hz max. 2 g acceleration Designs The flanged flowmeters comply with the installation lengths defined in VDI/VDE 2641, ISO 13359 or DVGW (W42, Design WP, ISO 464 short). 1

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 4.1.2 Material load for flanged design model DE41F / DE43F Limits for the allowable fluid temperature (TS) and allowable pressure (PS) are a function of the liner and flange materials of the flowmeter (see instrument name plate). Temperature limits Liner Flange material min. temp max. temp Hard-rubber Steel -1 C (14 F) 9 C (194 F) Hard-rubber Stainless steel -15 C (5 F) 9 C (194 F) 1.4571 Soft-rubber Steel -1 C (14 F) 7 C (158 F) Soft-rubber Stainless steel -15 C (5 F) 7 C (158 F) 1.4571 PTFE / PF Steel -1 C (14 F) 13 C (266 F) PTFE / PF Stainless steel 1.4571-25 C (-13 F) 13 C (266 F) DIN-Flange SS 1.4571 [316Ti] to DN 6 (24") PS [bar] 45 4 35 PN 4 3 25 2 PN 25 15 PN 16 1 5 PN 1-3 -1 1 3 5 7 9-22 14 32 5 86 122 158 194 Fig. 15 11 23 13 [ C] TS 266 [ F] G2 SME Flange SS1.4571[316TI] to DN 3 (12 ) (CL15/3) to DN 1 (4 ) (CL15) PS [bar] 55 Fig. 16 5 45 4 35 3 25 2 15 1 5-3 -22-1 14 32 1 5 CL3 CL15 3 86 5 122 7 158 9 194 11 23 13 [ C] TS 266 [ F] G21 SME flange carbon steel to DN 3 (12") (CL15/3) to DN 1 (4") (CL15) PS [bar] 55 5 CL3 45 4 35 3 25 2 CL15 15 1 5 Fig. 18-3 -22-1 14 32 1 5 3 86 5 122 7 158 9 194 11 23 13 266 [ C] TS [ F] G23 JIS 1K-B221 flange Meter Size Material PN TS PS [bar] 32... 1 (1¼... 4") SS1.4571 [316Ti] 1-25... +13 C (-13... +266 F) 1 32... 1 (1¼... 4") Carbon Steel 1-25... +13 C (-13... +266 F) DIN-Flange SS 1.4571 DN 7 (28") to DN 1 (4") PS [bar] 17 16 15 14 13 12 11 1 9 8 7 6-3 -22 Fig. 19-2 -1-4 14 32 1 5 2 68 1 DN 7 (28 ) PN 16 DN 9 (36 ) PN 16 DN 8 (32 ) PN 16 DN 1 (4 ) PN 16 DN 9 (36 ) PN 1 DN 8 (32 ) PN 1 DN 7 (28 ) PN 1 DN 1 (4 ) PN 1 3 4 5 6 7 8 9 [ C] TS 86 14 122 14 158 176 194 [ F] G24 DIN-Flange carbon steel DN 7 (28") to DN 1 (4") DIN-Flange Steel to DN 6 (24 ) PS [bar] 45 4 PN 4 35 3 25 2 PN 25 15 PN 16 1 5 PN 1-3 -1 1 3 5-22 14 32 5 86 122 Fig. 17 7 158 9 194 11 23 13 [ C] TS 266 [ F] G22 Fig. 2 11

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 4.1.3 Material load for wafer design models DE41W/DE43W Meter Size TS max TS min PS max [bar] 3-1 (1/1... 4") 13 C -1 C 16 (CL 15) (266 F) (14 F) 12

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Change from one to two columns 4.1.4 Flowmeter scale drawings for Model DE41F and DE43F Flange DN 3... 125 (1/1... 5") Tolerance: L* + / -3; Dimensions in mm Fig. 21 Flanges according to DIN/EN 192-1 8) Dimensions [mm] Weight approx. [kg] DN PN 1) D L 2)3) F C E COP-XE MG-XE 3-8 5) 1 15 2 1... 4 1... 4 1... 4 1... 4 9 9 95 15 13 2 2 2 219 243 243 243 62 82 82 82 157 181 181 181 6 6 6,5 7 5 5 5,5 6 25 32 4 5 65 8 1 125 1... 4 1... 4 1... 4 1... 4 1... 4 1... 4 1... 16 1... 16 115 14 15 165 185 2 22 25 2 2 2 2 2 2 25 25 243 25 25 256 267 267 289 299 82 92 92 97 18 18 122 13 181 188 188 194 25 25 227 237 Flanges according to SME B16.5 (for the dimensions F, C, E see table DIN flanges) Dimensions [mm] 8 9 1 12 16 19 22 29 Weight approx. [kg] 6,5 8 9 1 15 18 2 28 1) 2) 3) 4) 5) 6) 7) 8) CL15 CL3 L 3)4) 7) BB (old DN Zoll D D ISO 13359 installation length) 3-8 1/8... 5/16 6) 89 96 13 13 1 3/8 6) 89 96 2 27 15 1/2 89 96 2 27 2 3/4 98 118 2 27 25 32 4 5 65 8 1 125 1 1 1/4 1 1/2 2 2 1/2 3 4 5 18 118 127 153 178 191 229 254 124 134 156 165 191 21 254 28 2 2 2 2 2 2 25 25 27 28 28 28 33 34 4 45 COP-XE Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases as follows: DN 3... 1 by 3 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases as follows: DN 3... 1 by 6 mm. If protection flanges (mounted on each SME flange, old installation length) are installed, the L dimension increases as follows: - DN 3... 8 by 2 mm - DN 1 and larger by 25 mm Connection flange DN 1 Connection flange 1/2" For PF liner and SME flanges, only ISO installation lengths. Connection dimensions according to EN 192-1. For DN 65, PN 16 according to EN 192-1 please order PN 4. 6 6 6,5 7 8 9 1 12 16 19 28 36 MG-XE 5 5 5,5 6 6,5 8 9 1 15 18 27 35 13

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Flange DN 15... 4 (6... 16") MG-XE DE41F COP-XE DE43F 83,5 MG-XE DE41F COP-XE DE43F 23 12 88 88 35 D E 67 95 45 12 F L* G53 Tolerance: L* DN 15... 2 + / -3; DN 25 4 + / -5; Dimensions in mm Fig. 22 Flanges according to DIN/EN 192-1 Dimensions [mm] Weight approx. [kg] DN PN 1) D L F E COP-XE MG-XE 15 1-16 285 3 346 265 4 38 2 2 25 25 3 3 35 35 4 4 1 16 1 16 1 16 1 16 1 16 34 34 395 45 445 46 55 52 565 58 35 35 45 45 5 5 55 55 6 6 Flanges according to SME B16.5 (for the dimensions F, E see table DIN flanges) Dimensions [mm] Weight approx. [kg] CL15 CL3 2) 3) 4) L DN Zoll D D ISO 13359 BB (old installation COP-XE MG-XE length) 15 6 28 318 3 45 47 45 2 8 343 381 35 5 71 69 25 1 47 445 45 55 13 11 3 12 483 521 5 62 14 138 35 14 533-55 65 19 188 4 16 597-6 7 231 229 372 372 41 41 424 424 466 466 466 466 31 31 339 339 362 362 44 44 44 44 66 66 15 15 12 12 145 145 179 179 64 64 13 13 118 118 143 143 177 177 1) 2) 3) 4) Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases by 5 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases by 1 mm. If protection flanges (mounted on each SME flange, old installation length) are installed, the L dimension by 25 mm. 14

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Flange DN 45... 1 (18... 4") MG-XE DE41F 88 COP-XE DE43F MG-XE DE41F 88 35 COP-XE DE43F F G G1 67 Tolerance: L* DN 45... 5 + / -5; DN 6... 1 + / -1; Dimensions in mm Fig. 23 L* D G54 Flanges according to DIN/EN 192-1 Dimensions [mm] Weight approx. [kg] DN PN 1) D L F G G1 COP-XE MG-XE 5 1 67 65 31 492 43 196, 191, 6 1 78 78 361 543 454 276, 243, 7 1 895 91 448 57 495 319, 315, 8 1 115 14 58 62 545 49, 45, 9 1 1115 117 558 67 595 487, 483, 1 1 123 13 615 72 645 579, 575, Flanges up to DN6 (24 ) according to SME B16.5 (for the dimensions F see table DIN flanges) Flanges DN7 1 (28 4 ) according to SME B16.47 Serie B (for the dimensions F see table DIN flanges) Weight approx. [kg] Dimensions [mm] COP-XE MG-XE CL15 CL3 L 2) 3) 4) CL15 CL3 CL15 CL3 DN Inch D D ISO 13359 BB (old installation length) approx. kg approx. kg approx. kg 45 18 635-686 - 235-23 - 5 2 699-762 78 268-263 - 6 24 813-914 85 295-293 - 7 28 837 - - 91 387-385 8 32 942 - - 14 515-513 9 36 157 - - 117 664-552 1 4 138 - - 13 1134-1132 - approx. kg 1) 2) 3) 4) Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases by 5 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases by 1 mm. If protection flanges (mounted on each SME flange, old installation length) are installed, the L dimension by 25 mm. 15

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 4.1.5 Flowmeter scale drawings for Model DE41W and DE43W Wafer Design DN 3... 1 (1/1... 4") MG-XE DE41W COP-XE DE43W 77 MG-XE DE41W COP-XE DE43W 23 12 88 88 35 C E F 67 95 12 L B G6 Fig. 24 Dimensions in mm Dimensions [mm] Weight approx. [kg] DN PN L B C E F COP-XE MG-XE 3-1 16 69 75 62 157 281 3, 2, 15 16 69 75 62 157 281 3, 2, 25 16 91 95 73 168 292 4,5 3,5 32 16 99 13 78 173 297 5, 4, 4 16 14 112 82 177 31 6, 5, 5 16 119 13 9 185 337 6,5 5,5 65 16 13 146 14 199 365 8, 7, 8 16 13 163 11 25 377 9, 8, 1 16 133 19 13 225 417 1, 9, 16

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 4.1.6 Ordering Information Electromagnetic Flowmeter Variant digit No. 1-6 7 8 9 1 11 12 13 14 15 16 17 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Liner Material Meter Size PF DN 3 1/1 in. 1) 3) P 3 PF DN 4 5/32 in. 1) 3) P 4 PF DN 6 1/4 in. 1) 3) P 6 PF DN 8 5/16 in. 1) 3) P 8 PF DN 1 3/8 in. 1) P 1 PF DN 15 1/2 in. 1) P 1 5 PF DN 2 3/4 in. 1) P 2 PF DN 25 1 in. 1) P 2 5 PF DN 32 1-1/4 in. 1) P 3 2 PF DN 4 1-1/2 in. 1) P 4 PF DN 5 2 in. 1) P 5 PF DN 65 2-1/2 in. 1) P 6 5 PF DN 8 3 in. 1) P 8 PF DN 1 4 in. 1) P 1 H PTFE DN 1 3/8 in. T 1 PTFE DN 15 1/2 in. T 1 5 PTFE DN 2 3/4 in. T 2 PTFE DN 25 1 in. T 2 5 PTFE DN 32 1-1/4 in. T 3 2 PTFE DN 4 1-1/2 in. T 4 PTFE DN 5 2 in. T 5 PTFE DN 65 2-1/2 in. T 6 5 PTFE DN 8 3 in. T 8 PTFE DN 1 4 in. T 1 H PTFE DN 125 5 in. T 1 Q PTFE DN 15 6 in. T 1 F PTFE DN 2 8 in. T 2 H PTFE DN 25 1 in. T 2 F PTFE DN 3 12 in. T 3 H PTFE DN 35 14 in. T 3 F PTFE DN 4 16 in. T 4 H PTFE (only SME CL 15) DN 45 18 in. T 4 F PTFE DN 5 2 in. T 5 H PTFE DN 6 24 in. T 6 H Measuring Electrodes Material Grounding Electrodes 2) Hastelloy C-4 (2.461) Without H Hastelloy B-3 (2.46) Without B SST 1.4571 (316Ti) Without S Titanium Without M Tantalum Without T SST 1.4539 (94L) Without F Platinum-Iridium Without P Hastelloy C-4 (2.461) With O Hastelloy B-3 (2.46) With N SST 1.4571 (316Ti) With E Titanium With I Tantalum With Q SST 1.4539 (94L) With R Platinum-Iridium With G Continued on next page 1) PF with SME flanges only ISO-laid length (see pressure rating) 2) Grounding electrodes available only for meter size DN 3... DN 3 3) DN 3... DN 8 new laid length: 2 mm (for replacement with old laid length 13 mm please use model DE23F) Note to the 3 conformity: If 3 conformity is desired, please order model DE23 17

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 11 12 13 14 15 16 17 18 19 2 21 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Pressure Rating 3) PN 1 ISO laid length C PN 16 ISO laid length 4) D PN 25 ISO laid length E PN 4 Standard for DN 3... DN 8 ISO laid length F JIS K1 ISO laid length K SME CL 15 <= DN 6 (24 in.) old laid length, only for replacement P SME CL 3 <= DN 3 (12 in.) old laid length, only for replacement Q SME CL 15 <= DN 6 (24 in.) ISO laid length R SME CL 3 <= DN 4 (16 in.) ISO laid length S Material of Process Connection Steel from DN 2 1 SST 1.4571 (316Ti) Standard for DN 3... DN 15, option from DN 2 3 ccessories Without Protection rings 1.4571 (316Ti) (on both sides) 5) B Grounding ring 1.4571 (316Ti) (fastened on one side) 5) C Protection flanges 1.4571 (316Ti) (on both sides) 6) D Temperature Range Standard design <= 13 C (266 F) S Certificates PED Standard Material certificate per EN 124 3.1 + pressure test per D 2 D Pressure test per D 2 G Inspection certificate per EN 124 3.1 F without DGRL cerificate 7) K Calibration Certificates Standard Custody transfer, cold water / waste water (DN 25... DN 6 / 1 in.... 24 in.) B Custody transfer, fluids except water (DN 25... DN 15 / 1 in.... 6 in.) C Type of Protection IP 67 2 Power Supply 1... 23 V C N 16.8... 26.4 V C / 16.8... 31.2 V DC K Display Illuminated, with magnetic stick operation D Input / Output Options Current output active + Pulse output active + Contact input + Contact output 1 Current output active + Pulse output active + Contact input + Contact output + HRT 2 Current output active + Pulse output passive + Contact input + Contact output 3 Current output active + Pulse output passive + Contact input + Contact output + HRT 4 Current output active + Pulse output passive + Contact output + RS 485 5 Pulse output passive + Contact output + PROFIBUS DP 6 PROFIBUS P 3. 1 4 FOUNDTION Fieldbus not with Custody Transfer 1 5 PROFIBUS P 3. with M12 plug 1 6 Continued on next page 3) Connection dimensions for flanges acc. to DIN 251 or SME B16.5 or JIS B221-1K 4) DN 65 / PN 16 with connection dimensions acc. EN 192-1: Please order PN 4 5) Protection rings on both and grounding ring fastened on one side to flange, only possible for primary <= DN 3 and PTFE / PF lining 6) Only possible with SME flanges old laid length (pressure rating codes P, Q) and primary with PTFE / PF lining 7) possible from DN 5 (2 in.) 18

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 15 16 17 18 19 2 21 22 23 24 25 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Converter Housing Material Cable Entry luminium M2 x 1.5 luminium 1/2 in. NPT 2 luminium PF 1/2 in. 3 Name Plate German G English 8) E French 8) F Design Level (Specified by BB) * Electrode Design Standard 1 Excitation Frequency 6-1/4 Hz (DN 3... DN 6 1/1 in.... 24 in.) 1 12-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 2 7-1/2 Hz (DN 3... DN 6 1/1 in.... 24 in.) 3 15 Hz (DN 3... DN 1 1/1 in.... 4 in.) 4 25 Hz (DN 3... DN 2 1/1 in.... 3/4 in.) 5 8) not with Custody Transfer Electromagnetic Flowmeter Variant digit No. 1-6 7 8 9 1 11 12 13 14 15 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Liner Material Meter Size Hard rubber DN 15 1/2 in. H 1 5 Hard rubber DN 2 3/4 in. H 2 Hard rubber DN 25 1 in. H 2 5 Hard rubber DN 32 1-1/4 in. H 3 2 Hard rubber DN 4 1-1/2 in. H 4 Hard rubber DN 5 2 in. H 5 Hard rubber DN 65 2-1/2 in. H 6 5 Hard rubber DN 8 3 in. H 8 Hard rubber DN 1 4 in. H 1 H Hard rubber DN 125 5 in. H 1 Q Hard rubber DN 15 6 in. H 1 F Hard rubber DN 2 8 in. H 2 H Hard rubber DN 25 1 in. H 2 F Hard rubber DN 3 12 in. H 3 H Hard rubber DN 35 14 in. H 3 F Hard rubber DN 4 16 in. H 4 H Hard rubber (only SME CL 15) DN 45 18 in. H 4 F Hard rubber DN 5 2 in. H 5 H Hard rubber DN 6 24 in. H 6 H Hard rubber DN 7 28 in. H 7 H Hard rubber DN 8 32 in. H 8 H Hard rubber DN 9 36 in. H 9 H Hard rubber DN 1 4 in. H 1 T Soft rubber DN 5 2 in. S 5 Soft rubber DN 65 2-1/2 in. S 6 5 Soft rubber DN 8 3 in. S 8 Soft rubber DN 1 4 in. S 1 H Soft rubber DN 125 5 in. S 1 Q Soft rubber DN 15 6 in. S 1 F Soft rubber DN 2 8 in. S 2 H Soft rubber DN 25 1 in. S 2 F Soft rubber DN 3 12 in. S 3 H Soft rubber DN 35 14 in. S 3 F Soft rubber DN 4 16 in. S 4 H Soft rubber (only SME CL 15) DN 45 18 in. S 4 F Soft rubber DN 5 2 in. S 5 H Soft rubber DN 6 24 in. S 6 H Soft rubber DN 7 28 in. S 7 H Soft rubber DN 8 32 in. S 8 H Soft rubber DN 9 36 in. S 9 H Soft rubber DN 1 4 in. S 1 T Note to the 3 conformity: If 3 conformity is desired, please order model DE23 Continued on next page 19

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 1 11 12 13 14 15 16 17 18 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Measuring Electrodes Material Grounding Electrodes SST 1.4571 (316Ti) Without S Hastelloy C-4 (2.461) Without H Hastelloy B-3 (2.46) Without B Titanium Without M Tantalum Without T SST 1.4539 (94L) Without F Platinum-Iridium Without P SST 1.4571 (316Ti) With E Hastelloy C-4 (2.461) With O Hastelloy B-3 (2.46) With N Titanium With I Tantalum With Q SST 1.4539 (94L) With R Platinum-Iridium With G Pressure Rating 1) PN 1 ISO laid length C PN 16 ISO laid length 2) D PN 25 ISO laid length E PN 4 Standard for DN 15... DN 8 ISO laid length F JIS K1 ISO laid length K SME CL 15 <= DN 6 (24 in.) old laid length, only for replacement P SME CL 3 <= DN 3 (12 in.) old laid length, only for replacement Q SME CL 15 <= DN 6 (24 in.) ISO laid length R SME CL 3 <= DN 4 (16 in.) ISO laid length S Material of Process Connection Steel from DN 2 1 SST 1.4571 (316Ti) Standard for DN 15, option from DN 2 3 ccessories Without Temperature Range Standard design <= 9 C (194 F) S Certificates PED Standard Material certificate per EN 124 3.1 + pressure test per D 2 D Pressure test per D 2 G Inspection certificate per EN 124 3.1 F Without DGRL certificate 3) K Calibration Certificates Standard Custody transfer, cold water / waste water (DN 25... DN 6 / 1 in.... 24 in.) B Custody transfer, fluids except water (DN 25... DN 15 / 1 in.... 6 in.) C Type of Protection IP 67 2 Power Supply 1... 23 V C N 16.8... 26.4 V C / 16.8... 31.2 V DC K Continued on next page 1) Connection dimensions for flanges acc. to DIN 251 / EN 192-1 or SME B16.5 or JIS B221-1K 2) DN 65 / PN 16 with connection dimensions acc. EN 192-1: Please order PN 4 3) possible from DN 5 (2 in.) 2

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 18 19 2 21 22 23 24 25 26 FXE4-DE43F (COP-XE) Catalog No. DE43Fcompact with welded flange Display Illuminated, with magnetic stick operation D Input / Output Options Current output active + Pulse output active + Contact input + Contact output 1 Current output active + Pulse output active + Contact input + Contact output + HRT 2 Current output active + Pulse output passive + Contact input + Contact output 3 Current output active + Pulse output passive + Contact input + Contact output + HRT 4 Current output active + Pulse output passive + Contact output + RS 485 5 Pulse output passive + Contact output + PROFIBUS DP 6 PROFIBUS P 3. 1 4 FOUNDTION Fieldbus not with Custody Transfer 1 5 PROFIBUS P 3. with M12 plug 1 6 Converter Housing Material Cable Entry luminium M2 x 1.5 luminium 1/2 in. NPT 2 luminium PF 1/2 in. 3 Name Plate German G English 4) E French 4) F Design Level (Specified by BB) * Electrode Design Standard 1 Excitation Frequency 6-1/4 Hz (DN 3... DN 1 1/1 in.... 4 in.) 1 12-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 2 7-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 3 15 Hz (DN 3... DN 1 1/1 in.... 4 in.) 4 25 Hz (DN 3... DN 2 1/1 in.... 3/4 in.) 5 4) not with Custody Transfer 21

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 7 8 9 1 11 12 13 14 15 16 17 FXE4-DE41F (MG-XE) Catalog No. DE41Fremote with welded flange Liner Material Meter Size PF DN 3 1/1 in. 1) 3) P 3 PF DN 4 5/32 in. 1) 3) P 4 PF DN 6 1/4 in. 1) 3) P 6 PF DN 8 5/16 in. 1) 3) P 8 PF DN 1 3/8 in. 1) P 1 PF DN 15 1/2 in. 1) P 1 5 PF DN 2 3/4 in. 1) P 2 PF DN 25 1 in. 1) P 2 5 PF DN 32 1-1/4 in. 1) P 3 2 PF DN 4 1-1/2 in. 1) P 4 PF DN 5 2 in. 1) P 5 PF DN 65 2-1/2 in. 1) P 6 5 PF DN 8 3 in. 1) P 8 PF DN 1 4 in. 1) P 1 H PTFE DN 1 3/8 in. T 1 PTFE DN 15 1/2 in. T 1 5 PTFE DN 2 3/4 in. T 2 PTFE DN 25 1 in. T 2 5 PTFE DN 32 1-1/4 in. T 3 2 PTFE DN 4 1-1/2 in. T 4 PTFE DN 5 2 in. T 5 PTFE DN 65 2-1/2 in. T 6 5 PTFE DN 8 3 in. T 8 PTFE DN 1 4 in. T 1 H PTFE DN 125 5 in. T 1 Q PTFE DN 15 6 in. T 1 F PTFE DN 2 8 in. T 2 H PTFE DN 25 1 in. T 2 F PTFE DN 3 12 in. T 3 H PTFE DN 35 14 in. T 3 F PTFE DN 4 16 in. T 4 H PTFE (only SME CL 15) DN 45 18 in. T 4 F PTFE DN 5 2 in. T 5 H PTFE DN 6 24 in. T 6 H Measuring Electrodes Material Grounding Electrodes 2) Hastelloy C-4 (2.461) Without H Hastelloy B-3 (2.46) Without B SST 1.4571 (316Ti) Without S Titanium Without M Tantalum Without T SST 1.4539 (94L) Without F Platinum-Iridium Without P Hastelloy C-4 (2.461) With O Hastelloy B-3 (2.46) With N SST 1.4571 (316Ti) With E Titanium With I Tantalum With Q SST 1.4539 (94L) With R Platinum-Iridium With G Continued on next page 1) PF with SME flanges only ISO-laid length (see pressure rating) 2) Grounding electrodes available only for meter size DN 3... DN 3 3) DN 3... DN 8 new laid length: 2 mm (for replacement with old laid length 13 mm please use model DE23F) Note to the 3 conformity: If 3 conformity is desired, please order model DE21 22

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 11 12 13 14 15 16 17 18 19 2 21 FXE4-DE41F (MG-XE) Catalog No. DE41Fremote with welded flange Pressure Rating 3) PN 1 ISO laid length C PN 16 ISO laid length 4) D PN 25 ISO laid length E PN 4 Standard for DN 3... DN 8 ISO laid length F JIS K1 ISO laid length K SME CL 15 <= DN 6 (24 in.) old laid length, only for replacement P SME CL 3 <= DN 3 (12 in.) old laid length, only for replacement Q SME CL 15 <= DN 6 (24 in.) ISO laid length R SME CL 3 <= DN 4 (16 in.) ISO laid length S Material of Process Connection Steel from DN 2 1 SST 1.4571 (316Ti) Standard for DN 3... DN 15, option from DN 2 3 ccessories without Protection rings 1.4571 (316Ti) (on both sides) 5) B Grounding ring 1.4571 (316Ti) (fastened on one side) 5) C Protection flanges 1.4571 (316Ti) (on both sides) 6) D Temperature Range Standard design <= 13 C (266 F) S Certificates PED Standard Material certificate per EN 124 3.1 + pressure test per D 2 D Pressure test per D 2 G Inspection certificate per EN 124 3.1 F Without DGRL certificate possible from DN 5 (2 in.) K Calibration Certificates Standard Custody transfer, cold water / waste water (DN 25... DN 6 / 1 in.... 24 in.) B Custody transfer, fluids except water (DN 25... DN 15 / 1 in.... 6 in.) C Type of Protection Cable Entry IP 67 Thread for screw-type conduit fitting M2 x 1.5 2 IP 67 Thread for screw-type conduit fitting NPT 1/2 in. 4 IP 67 Thread for screw-type conduit fitting PF 1/2 in. 5 IP 68 Thread for screw-type conduit fitting M2 x 1.5 7) 7 IP 68 Cable connected and Connection box potted 8 Name Plate German G English E French F Design Level (Specified by BB) * Electrode Design Standard 1 Excitation Frequency 6-1/4 Hz (DN 3... DN 6 1/1 in.... 24 in.) 1 12-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 2 7-1/2 Hz (DN 3... DN 6 1/1 in.... 24 in.) 3 15 Hz (DN 3... DN 1 1/1 in.... 4 in.) 4 25 Hz (DN 3... DN 2 1/1 in.... 3/4 in.) 5 3) Connection dimensions for flanges acc. to DIN 251 / EN 192-1 or SME B16.5 or JIS B221-1K 4) DN 65 / PN 16 with connection dimensions acc. EN 192-1: Please order PN 4 5) Protection rings on both and grounding ring fastened on one side to flange, only possible for primary <= DN 3 and PTFE / PF lining 6) Only possible with SME flanges old laid length (pressure rating codes P, Q) and primary with PTFE / PF lining Related Converter FXE4-E4 7) Sealing compound (optionally) D141B38U1 23

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 7 8 9 1 11 12 13 FXE4-DE41F (MG-XE) Catalog No. DE41Fremote with welded flange Liner Material Meter Size Hard rubber DN 15 1/2 in. H 1 5 Hard rubber DN 2 3/4 in. H 2 Hard rubber DN 25 1 in. H 2 5 Hard rubber DN 32 1-1/4 in. H 3 2 Hard rubber DN 4 1-1/2 in. H 4 Hard rubber DN 5 2 in. H 5 Hard rubber DN 65 2-1/2 in. H 6 5 Hard rubber DN 8 3 in. H 8 Hard rubber DN 1 4 in. H 1 H Hard rubber DN 125 5 in. H 1 Q Hard rubber DN 15 6 in. H 1 F Hard rubber DN 2 8 in. H 2 H Hard rubber DN 25 1 in. H 2 F Hard rubber DN 3 12 in. H 3 H Hard rubber DN 35 14 in. H 3 F Hard rubber DN 4 16 in. H 4 H Hard rubber (only SME CL 15) DN 45 18 in. H 4 F Hard rubber DN 5 2 in. H 5 H Hard rubber DN 6 24 in. H 6 H Hard rubber DN 7 28 in. H 7 H Hard rubber DN 8 32 in. H 8 H Hard rubber DN 9 36 in. H 9 H Hard rubber DN 1 4 in. H 1 T Soft rubber DN 5 2 in. S 5 Soft rubber DN 65 2-1/2 in. S 6 5 Soft rubber DN 8 3 in. S 8 Soft rubber DN 1 4 in. S 1 H Soft rubber DN 125 5 in. S 1 Q Soft rubber DN 15 6 in. S 1 F Soft rubber DN 2 8 in. S 2 H Soft rubber DN 25 1 in. S 2 F Soft rubber DN 3 12 in. S 3 H Soft rubber DN 35 14 in. S 3 F Soft rubber DN 4 16 in. S 4 H Soft rubber (only SME CL 15) DN 45 18 in. S 4 F Soft rubber DN 5 2 in. S 5 H Soft rubber DN 6 24 in. S 6 H Soft rubber DN 7 28 in. S 7 H Soft rubber DN 8 32 in. S 8 H Soft rubber DN 9 36 in. S 9 H Soft rubber DN 1 4 in. S 1 T Continued on next page 24

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 1 11 12 13 14 15 16 FXE4-DE41F (MG-XE) Catalog No. DE41Fremote with welded flange Measuring Electrodes Material Grounding Electrodes SST 1.4571 (316Ti) Without S Hastelloy C-4 (2.461) Without H Hastelloy B-3 (2.46) Without B Titanium Without M Tantalum Without T SST 1.4539 (94L) Without F Platinum-Iridium Without P SST 1.4571 (316Ti) With E Hastelloy C-4 (2.461) With O Hastelloy B-3 (2.46) With N Titanium With I Tantalum With Q SST 1.4539 (94L) With R Platinum-Iridium With G Pressure Rating 1) PN 1 ISO laid length C PN 16 ISO laid length 2) D PN 25 ISO laid length E PN 4 Standard for DN 15... DN 8 ISO laid length F JIS K1 ISO laid length K SME CL 15 <= DN 6 (24 in.) old laid length, only for replacement P SME CL 3 <= DN 3 (12 in.) old laid length, only for replacement Q SME CL 15 <= DN 6 (24 in.) ISO laid length R SME CL 3 <= DN 4 (16 in.) ISO laid length S Material of Process Connection Steel from DN 2 1 SST 1.4571 (316Ti) Standard for DN 15, option from DN 2 3 ccessories Without Temperature Range Standard design <= 9 C (194 F) S Certificates PED Standard Material certificate per EN 124 3.1 + pressure test per D 2 D Pressure test per D 2 G Inspection certificate per EN 124 3.1 F Without DGRL certificate 3) K Calibration Certificates Standard Custody transfer, cold water / waste water (DN 25... DN 1 / 1 in.... 4 in.) B Custody transfer, fluids except water (DN 25... DN 15 / 1 in.... 6 in.) C Continued on next page 1) Connection dimensions for flanges acc. to DIN 251 / EN 192-1 or SME B16.5 or JIS B221-1K 2) DN 65 / PN 16 with connection dimensions acc. EN 192-1: Please order PN 4 3) possible from DN 5 (2 in.) Note to the 3 conformity: If 3 conformity is desired, please order model DE21 25

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 15 16 17 18 19 2 21 FXE4-DE41F (MG-XE) Catalog No. DE41Fremote with welded flange Type of Protection Cable Entry IP 67 Thread for screw-type conduit fitting M2 x 1.5 2 IP 67 Thread for screw-type conduit fitting NPT 1/2 in. 4 IP 67 Thread for screw-type conduit fitting PF 1/2 in. 5 IP 68 Thread for screw-type conduit fitting M2 x 1.5 4) 7 IP 68 Cable connected and Connection box potted 8 Name Plate German G English E French F Design Level (Specified by BB) * Electrode Design Standard 1 Excitation Frequency 6-1/4 Hz (DN 3... DN 1 1/1 in.... 4 in.) 1 12-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 2 7-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 3 15 Hz (DN 3... DN 1 1/1 in.... 4 in.) 4 25 Hz (DN 3... DN 2 1/1 in.... 3/4 in.) 5 Related Converter FXE4-E4 4) Sealing compound (optionally) D141B38U1 26

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 7 8 9 1 11 12 13 14 15 16 17 FXE4-DE43W (COP-XE) Catalog No. DE43Wcompact wafer type Liner Material Meter Size PF DN 3 1/1 in. P 3 PF DN 4 5/32 in. P 4 PF DN 6 1/4 in. P 6 PF DN 8 5/16 in. P 8 PTFE DN 1 3/8 in. T 1 PTFE DN 15 1/2 in. T 1 5 PTFE DN 25 1 in. T 2 5 PTFE DN 32 1-1/4 in. T 3 2 PTFE DN 4 1-1/2 in. T 4 PTFE DN 5 2 T 5 PTFE DN 65 2-1/2 in. T 6 5 PTFE DN 8 3 in. T 8 PTFE DN 1 4 in. T 1 H Measuring Electrodes Material Grounding Electrodes 1) Hastelloy C-4 (2.461) Without H Hastelloy B-3 (2.46) Without B SST 1.4571 (316Ti) Without S Titanium Without M Tantalum Without T SST 1.4539 (94L) Without F Platinum-Iridium Without P Hastelloy C-4 (2.461) With O Hastelloy B-3 (2.46) With N SST 1.4571 (316Ti) With E Titanium With I Tantalum With Q SST 1.4539 (94L) With R Platinum-Iridium With G Pressure Rating 2) PN 16 D SME CL 15 P JIS K1 K Certificates PED Standard Material certificate per EN 124 3.1 + pressure test per D 2 D Pressure test per D 2 G Inspection certificate per EN 124 3.1 F Calibration Certificates Standard Custody transfer, cold water / waste water (DN 25... DN 1 / 1 in.... 4 in.) B Custody transfer, fluids except water (DN 25... DN 1 / 1 in.... 4 in.) C Type of Protection IP 67 2 Power Supply 1... 23 V C N 16.8... 26.4 V C / 16.8... 31.2 V DC K Display Illuminated, with magnetic stick operation 1) Grounding electrodes available only for meter size DN 3... DN 3 2) Connection dimensions for flanges acc. to DIN 251 / EN 192-1 or SME B16.5 or JIS B221-1K ccessories see table H D Continued on next page 27

Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) D184S75U2 Electromagnetic Flowmeter Variant digit No. 1-6 13 14 15 16 17 18 19 2 21 22 23 FXE4-DE43W (COP-XE) Catalog No. DE43Wcompact wafer type Input / Output Options Current output active + Pulse output active + Contact input + Contact output 1 Current output active + Pulse output active + Contact input + Contact output + HRT 2 Current output active + Pulse output passive + Contact input + Contact output 3 Current output active + Pulse output passive + Contact input + Contact output + HRT 4 Current output active + Pulse output passive + Contact output + RS 485 5 Pulse output passive + Contact output + PROFIBUS DP 6 PROFIBUS P 3. 1 4 FOUNDTION Fieldbus not with Custody Transfer 1 5 PROFIBUS P 3. with M12 plug 1 6 Converter Housing Material Cable Entry luminium M2 x 1.5 luminium 1/2 in. NPT 2 luminium PF 1/2 in. 3 Name Plate German G English 3) E French 3) F Design Level (Specified by BB) * Electrode Design Standard 1 Excitation Frequency 6-1/4 Hz (DN 3... DN 1 1/1 in.... 4 in.) 1 12-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 2 7-1/2 Hz (DN 3... DN 1 1/1 in.... 4 in.) 3 15 Hz (DN 3... DN 1 1/1 in.... 4 in.) 4 25 Hz (DN 3... DN 15 1/1 in.... 1/2 in.) 5 3) not with Custody Transfer 28