LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

Similar documents
LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

all you Need for emc testing The complete product range Innovative equipment for emc testing and measuring

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

all you Need for emc testing The complete product range Innovative equipment for emc testing and measuring

LVA 4-Quadrant Amplifier 5000

IEC Electrical fast transient / Burst immunity test

RF Conducted Immunity and Automotive Transient Generator Test Systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

LVA 4-Quadrant Amplifier 1000

Voltage dips short interruptions with PFS and Netwave

automotive EMC solutions

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Voltage Transient Emission Test

Advanced Test Solutions for EMC AUTOMOTIVE ELECTRICAL DISTURBANCES TRANSIENT EMISSIONS, IMMUNITY AND BATTERY SIMULATIONS

LVA series of 4-Quadrant amplifiers

Application Note #42 Conducted Transients in Road Vehicles Supply Lines

CONDUCTED AUTOMOTIVE EMC

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TRANSIENT EMISSIONS, IMMUNITY and battery SIMULATIONS

Summary. Introduction

Center for Quality Engineering. Test Report No.: B0JA0002

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

CAR - TEST - SYSTEM 14

Center for Quality Engineering. Test Report No.: B0EF0002

ELECTRONICS TESTING CENTER, TAIWAN

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

SIOV metal oxide varistors

FLEXTRONICS LABORATORY MANAGEMENT SYSTEM

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

ELECTRONICS TESTING CENTER, TAIWAN

ISO/TS ELECTRICAL DISTURBANCES BY CONDUCTION AND COUPLING PART 4: ELECTRICAL TRANSIENT CONDUCTION ALONG SHIELDED HIGH VOLTAGE SUPPLY LINES ONLY

METRAClip87 and 88 Clamp Multimeters

We re In The Business Of Making Your Life Easier

PRODUCT DATA. Sound Intensity Calibrator Type 4297

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

FLEXTRONICS LABORATORY MANAGEMENT SYSTEM

Arbitrary power supplies. 160 W to 5200 W

2004/104/EC Measurement and Test Report

SPECIFICATION. LED Driver. Model : SI-EPF006650WW CUSTOMER : SAMSUNG CHECKED APPROVED DRAWN SAMSUNG #2, NONGSEO-DONG, GIHEUNG-GU,

High-precision process calibrator Model CED7000

METRAClip85 and 86 Clamp Multimeters

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Part 1: General. Part 3: Mechanical loads Part 4: Climatic loads Part 5: Chemical loads

User Manual for 24 GHz Blind-Spot Radar Sensor

MGA Magnetic field system. DC khz

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

Nsg inductive switch transient test circuit

Technical Manual Modulation Box

Product Introduction. MF2400C Series. Microwave Frequency Counter

Product Introduction. MF2400C Series. Microwave Frequency Counter

RADIATED IMMUNITY TEST SYSTEM 6 GHz

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Voltage Sensors URV5-Z

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

30 A AC/DC Current Probe TCP0030A Datasheet

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

Proper Bias-T Usage to Avoid PPG Damage

Pressure transmitter For general industrial applications Model A-10

Wide-band Models from DC to 100 MHz

Cable Identifier Reliable cable selection for energised and de-energised cables

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Low Frequency Measuring System

TESTING LABORATORY EQUIPMENT

Transcription:

LD 200N WITH CLIPPING-MODULE FOR TESTS ACCORDING TO... > BMW - (Airbag ECU) > BMW 600 13.0 (Part 1) > BMW 600 13.0 (Part 2) > BMW GS 95002 (1999) > BMW GS 95003-2 > Case New Holland ENS0310 > Chrysler CS-11979 > Chrysler PF-9326 > Claas CN 05 0215 > Cummins 14269 (982022-026) > DaimlerChrysler DC-10842 > DaimlerChrysler PF-10540 > EN 300329 > EN 300340 > EN 300342-1 > EN 301489-1 > EN 301489-17 > FAW Diesel ECU MY06.0 (Rev.7) > Fiat 9.90110 > Ford EMC-CS-2009.1 > Ford ES-XW7T-1A278-AB >... LD 200N - COMPACT HIGH-ENERGY Load Dump pulses simulate a sudden battery disconnection (e.g. by corrosion) from the alternator. Cause the lost of the battery load the alternator generates an overvoltage impulse. Such Load Dump pulses are high energy pulses with a high potential of destruction. The LD 200N simulates these high energy pulses having a duration time in the range of hundreds of milliseconds. The LD 200N generates the Load Dump pulses as per ISO 7637, ISO 16750-2, SAE J1113, SAE J1455, JASO and many more manufacturer specification, e.g. Ford, Chrysler, Renault, PSA, NISSAN etc. By means of a built-in clipping circuit the LD 200N also generates clipped load dump pulses as per international standards as well as manufacturer requirements. HIGHLIGHTS > Load Dump generator according to ISO 7637, ISO 16750-2, SAE J1113, SAE J1455, JASO, Nissan and most car manufacturer requirements APPLICATION AREAS AUTOMOTIVE TELECOM > Generates Clipped Load Dump pulses > Built-in 0.5-38 Ohm source impedance, selectable in 0.1 Ohm steps > up to 1,200ms EM TEST > PAGE 1/6

PULSE SPECIFICATION SAE J1455 FOR 12V BATTERY SUPPLY +86V ± 10% 100us (10% - 90%) 400ms ± 10% (10-10%) 0.4ohm 20V - 200V ± 10% ISO PULSE 5 AND 7 5ms - 10ms (10-90%) 40-400ms (10-10%) - 38ohm, selectable in steps of 0.1ohm Min. 30s ISO 16750-2, 12V SYSTEM +79V to 101V ± 10% 40-400ms ± 10% (10-10%) - 4ohm ISO 16750-2, 24V SYSTEM +151 V to 202 V ± 10 % 100-350ms ± 10% (10-10%) 1ohm - 8ohm ISO 7637-2:2004, 12V SYSTEM +65V to 87V ± 10% 40-400ms ± 10% (10-10%) - 4ohm ISO 7637-2:2004, 24V SYSTEM +123V to 174V ± 10% 100-350ms ± 10% (10-10%) 1ohm - 8ohm SAE J1455 FOR 24V BATTERY SUPPLY +122V ± 10% 100us 400ms ± 10% (10-10%) 0.8ohm JASO PULSE A1 +70V ± 10% 1us (10% - 90%) 200ms ± 10% (measured at tau) 0.8ohm 110mF JASO PULSE B1 (FIELD DECAY) -80V ± 10% 1us (10% - 90%) 60ms (measured at tau) 8ohm 3mF JASO PULSE D1 +110V ± 10% 1us (10% - 90%) 400ms (measured at tau) 1.5ohm 73mF EM TEST > PAGE 2/6

CHRYSLER PF 9326 PULSE 5 FORD EMC-CS-2009.1, PULSE G1 +91.5V ± 10% 5-10ms (10% - 90%) 300ms td (10-10%) 300ms ± 20% Loaded pulse +45.75V ± 10% into a load 30V ± 10% into a load > 95ms (10-10%) 120s FORD EMC-CS-2009.1, PULSE G2 FORD ES-XW7T CI 240 (AB-VERSION) 30V ± 10% into a load 21.5V (-1/+0V) Voltage (suppressed) 300ms (10% - 10%) 30V ± 10% into a 0.7ohm load 150ms ± 10% (10-10%) 3 pulses every 30s FORD ES-XW7T CI 220G (AC-VERSION) 300ms (10% - 10%) 30V ± 10% into a load 150ms ± 10% (10-10%) 3 pulses every 30s FORD FMC1278, CI222 PULSE 5A 300ms ± 20% 30V ± 10% into a loadv FORD FMC1278, CI222 PULSE 5B 30V ± 10% into a load Voltage (suppressed) 21.5V (-1/+0V) EM TEST > PAGE 3/6

LOAD DUMPGENERATOR MERCEDES BENZ MBN 10 284 PART 2 NISSAN PULSE A1 100V ± 10% (Pulse 5a for 12V) + < 0.1ms (10% - 90%) 1ms ± 50% (10% - 90%) 400ms (10-10%) R1 18ohm 2ohm R2 0.66ohm 200V ± 10% (Pulse 5a for 24V) 15mF < 0.1ms (10% - 90%) 500ms (10-10%) NISSAN PULSE A2 2ohm + 100V ± 10% (Pulse 5a for 42V) 1ms ± 50% (10% - 90%) < 0.1ms (10% - 90%) R1 11ohm 400ms (10-10%) R2 0.8ohm 2ohm 1mF 120s NISSAN PULSE B1 SCANIA TB1400 +80V ± 10% +90V ± 10% for trucks 1ms ± 50% (10% - 90%) R1 20ohm 300ms (10-10%) R2 20ohm +125V ± 10% for buses 1mF 480ms (10-10%) 1.5ohm SCANIA TB1700 +125V ± 10% 480ms (10-10%) 1.5ohm TEST ROUTINES ISO 7637-2 Load Dump & Field Decay PF-9326 Pulse 5a and 5b Ford ES-XW7T, AB & AC versions EMC-CS-2009.1 MBN 10284 Pulse 5a, 5b and 5c SCANIA Pulse 5 & 5b (TB1400 and TB1700) JASO Pulse A1, B1, D1 NISSAN Pulse A1, A2, B1 Service Service, setup, self test EM TEST > PAGE 4/6

FREESTYLE MODE LOAD DUMP GENERAL DATA PULSE PROGRAMMING MODE DIMENSIONS AND WEIGHT Dimensions 19"/6HU, 500mm x 450mm x 290mm Weight approx. 25kg Supply voltage 115V/230V +10%/-15% Fuses 2x T2AT (230V) or 2x T4AT (115V) <1us 10us - 90us with 10us steps 100us - 900us with 100us steps 1ms - 10ms with 1ms steps 10ms - 1,200ms - 38ohm, in steps of 0.1ohm OUTPUT MODULE CLIPPED LOAD DUMP TEST ROUTINES +/- output Safety laboratory connectors Coupling To the battery +line Decoupling Via diode DUT supply Max. 80V/30A Standard Test routines pre-programmed and controlled via iso.control ISO 7637-2 for 12V and 24V ISO/WD 16750 SAE J1113-11 EMC-CS-2009.1 (Ford) Pulse G2 FIAT 9.90110 Pulse 5a PSA B21 7110 for 12V Volvo Pulse 5a and 5c GS 95003-2 Porsche EMV Pulse 5 GMW 3097 36.00.808 TSC 7034G Iveco Scania TB1400 OPTIONS Scania TB1700 iso.control ES 96100-02 Software to control the test, including standard library, test report facility and data conversion generator CA ISO Pulse verification set for micropulse and load dump pulse verification PULSE PROGRAMMING MODE Clipped Voltage 15V - 99.5V, in steps of 0.5V 100us - 10ms 10ms - 1,200ms - 38ohm, in steps of 0.1ohm INTERFACE Serial interface USB Parallel interface IEEE 488, addresses 1-30 CN interface To control external CN - UCS 200N ENVIRONMENT Temperature 10 C to 35 C Humidity 30 % to 75 %, non condensing Atmospheric pressure 86 kpa (860 mbar) to 106 kpa (1,060 mbar) OPTIONS EM TEST > PAGE 5/6

COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland USA / Canada EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837 Phone +1 (732) 417-0501 Internet: > E-mail: sales.emtest@ametek.com Germany AMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Phone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: > E-mail: info.cts@ametek.de France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Phone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr P.R. China E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Phone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: > E-mail: info@emtest.com.cn Republic of Korea EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Phone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Poland EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Phone +48 (0)518 64 35 12 Internet: /pl > E-mail: infopolska.emtest@ametek.com Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject to change without further notice. EM TEST > PAGE 6/6