MANUAL. Electrostatic Field Meter EFM 120. System Prof. Dr.-Ing. Hans Kleinwächter

Similar documents
MANUAL. Electrostatic Field Meter EFM 235 / 255. System Prof. Dr.-Ing. Hans Kleinwächter

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

DIGITAL MULTIMETER INSTRUCTION MANUAL

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

Model: &

ProfiScale MULTI Multimeter

FMX 003. Gebruikershandleiding NL Pagina 3. Bedienungsanleitung D Seite 12. User s Manual UK Page 21. Notice d uilisation F Page 30

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

VC835 DIGTAL MULTIMETER Operation Manual

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

4.5 Auto Power Off During use Preparation For Measurement Symbols...3

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

AMM-1022 Digital Multimeter USER`S MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Analog Technologies VC99. Multimeter FEATURES

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

Dawson DDM190. Digital Multimeter User s Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DIGIT & POINTER MULTIMETER

200Amp AC Clamp Meter + NCV Model MA250

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

LF Conductivity Measuring Probe

USER'S MANUAL DMR-6700

3B SCIENTIFIC PHYSICS

MS2109A AC/DC Clamp Meter. User Manual. Contents

Model DIGITAL MULTIMETER

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

3B SCIENTIFIC PHYSICS

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

audionet amp II G2 Owner's Manual Mono - Amplifier

CONTENTS MS2033A. 1.Introduction Safety Information...01

400Amp True RMS AC Clamp Meter + NCV

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

Starship Lighting Kit

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OPERATOR S INSTRUCTION MANUAL

DM-46 Instruction Manual

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

MS2030 CAT III 600 V A V AUTO RS232

DDM350 Pen-Type Digital Multimeter User s Manual

Telemetrie-Messtechnik Schnorrenberg

400Amp True RMS AC/DC Clamp Meter Model EX613

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User Manual Digital Multimeter

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MS8223A. CAT.IIi 600 V

Passive Component LCR Meter

METRAVI. Table of Contents

DVM1190 DIGITAL MULTIMETER

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

MI-10kV. Technical specifications Operating instructions. Supplier:

GFL-1000 User Manual Ground Fault Locator

GENERAL OPERATING INFORMATION

7006 Loop Mate 1 Loop / Voltage / Current Simulator

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

The Meter Structure The Figure 2-1 shows the Meter structure.

Schlöder GmbH - EMC Test and Measurement Systems Model #

AC MASTER Switch mode sine wave inverter

User s Guide. Model MA A AC Mini Clamp-on Meter

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

USER'S MANUAL DMR-4350

0.01kV (0 to ±0.99 kv)

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

User Guide. AC/DC Mini Clamp Meter. Model

True RMS AC / DC Power Clamp Meter Model

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

USER'S MANUAL DMR-4300

OPERATING INSTRUCTION

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TS-700/1000 INVERTER Instruction Manual

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

2015 RIGOL TECHNOLOGIES, INC.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Multifunction Digital

5XP-A 15XP-A 35XP-A Compact Digital Multimeters

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Transcription:

MANUAL Electrostatic Field Meter EFM 120 System Prof. Dr.-Ing. Hans Kleinwächter

2 Manual EFM 120 Contents General information on electrostatics... 3 Origin of electrostatic charge... 3 Product description... 3 Specifications... 4 Legend... 4 Manual... 5 Measuring principle... 5 Application Areas... 5 Initiation... 5 Measurement Range Switching / Automatic Mode... 5 Measurement Range Exceeding... 5 Display... 6 Recorder Output... 6 Battery Supervision... 6 Grounding... 6 Zero Point Adjustment... 6 Electric Field Strength... 6 Voltage Metering with MK11... 7 Maintenance... 7 NiMH Storage Battery... 7 Warranty... 7 Scope of Delivery... 8 Warning Notices... 8 Calibration... 8

General information on electrostatics 3 General information on electrostatics Nowadays ESD 1 is a problem at many workstations, because modern microelectronics 2 is easily destroyed by the sequels of ESD. Other branches of industry like e.g. telecommunications-, plastics-, and explosive material industry are also heavily affected by ESD. ESD causes losses of time as well as high financial losses and can endanger the human health. Charges of over 10000 Volts can emerge on people, clothes, materials and equipment. Devices that are sensitive to electrostatics can be damaged by electrostatic discharges of less than 100 Volts. Charges of 3000 Volts and more can cause sparks. In endangered areas that can cause explosions. Origin of electrostatic charge Triboelectricity 3 is caused by attrition of different materials. Electrons are transferred from one material to the other. As electrons are charged negative the material that releases electrons is charged positive. The material admitting electrons is charged negative. There are different ways to avoid or to discharge electrostatic charges. But to find an effective and reasonable solution first of all the emergence, amount and polarity of the charge have to be found. Our devices are suitable for that purpose and for the supervision of favored charge. Product description The unit is housed into an EMV plastic enclosure. The influence electrode is star shaped. In front of it in a small distance apart a rotating grounded modulation propeller with the same shape as the electrode is located. The influence electrode is enclosed by a ring electrode system that is used as mechanical shield for the propeller wheel and the sensor plate. Measurement values are displayed with a 21 digit LED bargraph. The device has an integrated micro computer with the following functions: Automatic functional check on powering on One button operation Permanent supervision of the battery voltage with automatic shut-down 1 electrostatic discharge 2 integrated circuits 3 Greek: tribeia = friction

4 Manual EFM 120 Specifications Dimensions (L x B x H): Approx. 80mm x 100mm x 40mm Weight: Approx. 380g Calibration in a plate capacitor: 285mm x 285mm, distance 100mm Calibration accuracy: < 2,5% Output voltage ±1V Internal resistance >1kΩ Power supply Integrated battery / charger 230V 50Hz Battery: NiMH storage battery pack 7,2V 350mAh Operating time: Min. 4h in battery mode Measurement ranges ±20kV/m, ±200kV/m, ±2MV/m Legend 1 2 1 0 1 2 - + 7 2 200 kv/m 20 kv/m 2 MV/m auto 8 range 3 9 4 on/off range 10 EFM 120 5 11 6 12 1 LED bargraph 7 Protective cap 2 Range indicator LEDs 8 Modulator system 3 Battery charge indicator 9 Buzzer 4 «on/off/range» button 10 Automatic LED 5 Charge socket 11 Recorder output 6 Grounding socket 12 Zero point trimmer

Manual 5 Manual Measuring principle The electrostatic field meter is a parametric amplifier. The electric field influences a current proportional to the electrostatic field. The current is amplified and measured with a selective amplifier. No energy is taken from the field over time means. No radioactive matters are used! Application Areas Detection and Control of electrostatic fields resp. charges, measuring of electric charges, electrostatic charges, very high-resistance voltage sources, very low currents or high resistances. Initiation By pressing the «function/on/range» button on the front panel the device is switched on. By holding the «function/on» button pressed until the device buzzes, the EFM 120 is switched off. The protective cap on the modulator system has to be removed before measuring! Measurement Range Switching / Automatic Mode The device has 3 manual measurement ranges and an automatic mode. Switching is performed by pressing the «on/off/range» button briefly while the unit is switched on. After switching on the most sensitive range (± 20kV/m manual) is selected. After pressing the button, the range switches to ± 200 kv/m and to ± 2MV/m after pressing again. If the button is pressed in ± 2MV/m mode, the EFM 120 switches to automatic mode. This indicated by the automatic indicator LED. In automatic mode the device selects the optimal measurement range and displays it by LEDs. Each time the button is pressed, the measurement range is changed in the following order: 20kV/m 200kV/m 2MV/m Automatik 20kV/m... Measurement Range Exceeding If the measurement rang is exceeded in manual mode, the outer two LEDs will flash on the side were the exceeding takes place (+ or -). In addition an audio warning resounds. In this case a higher range has to be selected. In automatic mode the device switches to the next higher measurement range when the range is exceeded. If highest range is already selected, the outer LEDs start flashing next on the side where the exceeding took place (+ or -). Additionally an audio alert resounds. In this case the distance to the object to be measured has to be increased. If the measured value falls below 10% of the range s maximum value the EFM 120 switches to a lower range if possible.

6 Manual EFM 120 Display The measured value display is a 21 digit LED bargraph with zero point (green LED). The measured value is displayed by 10 LEDs for each polarity. Due to the smooth transition, the scalereading precision is about 5%. Recorder Output On the rear side of the device a recorder output with jack bush for the connection of an external recorder or voltmeter is located. The output voltage is ±1V proportional to the electric field strength measured. The metering precision is ±2.5% in a homogeneous field. Battery Supervision The device has an integrated battery supervision function. If the battery voltage falls below 6.8V, the " " LED lights. By falling below 6.5V the device buzzes (a long beep followed by a short one). To prevent total discharge of the battery the device is automatically powered off. In this case the battery has to be loaded with the shipped charger for about 12-14h. Grounding The device has to be grounded properly to measure the amount and the polarity of an electrostatic field. For that purpose the device has to be connected to ground by using the grounding jack (4). Grounding the device by a grounded person (e.g. over conductive shoes or wrist strap) touching the grounding jack suffices under most circumstances. Zero Point Adjustment Under normal circumstances a zero point adjustment is not necessary. If green led does not light while the modulator system is screened (e.g. mounted cover cap) the zero point can be adjusted using the trimmer (12) on the right side of the device. Electric Field Strength For measuring the electric field strength at first the protective cap has to be removed. Afterwards the electro static field meter has to be adjusted with the modulator system parallel to the object to be measured. The distance between the EFM 120 and the object to be measured must be kept constant, as the distance is for the voltage calculation. The measured field strength is displayed in kv/m. The charge in Volt is obtained by multiplying the displayed value with the distance in meters. For example: The distance d between the object and the device is 5cm and the measured field strength E is 1,6kV/m, the surface potential U is calculated as follows:: pontential = strength distance U = E d = 1600V m 0, 05m = 80V Please pay attention to use correct units. To avoid this problem we recommend using SI units.

Maintenance 7 Voltage Metering with MK11 With the optional voltage gauge head MK11 voltages up to ±2kV can be measured with an internal resistance R i >10 15 Ω. For high voltage measurements the guidelines of the European standard EN 10100 need to be considered. The voltage gauge head has to be mounted on the modulator system of the static meter for measurements. As the internal teflonized field plate is located in a distance of 1cm to the modulator field plate, the following measurement ranges are obtained: ±200V ±2kV Measurements up to ±20kV are not realizable due to potential spark formation in this range. The generated linear voltmeter has the following outstanding properties: Input capacitance: Input resistance: approx. 5pF >10 16 Ω with appropriate gauge head Maintenance The modulator system or parts of it must not be touched. Those parts have to be protected of dust, isolating impurity layers, color- or paint haze and condensate. If required the modulator system can be cleaned with ethyl alcohol and a lint-free cotton cloth. NiMH Storage Battery Even if the device is not used for longer terms, the battery has to be charged after 6 month to prevent total discharge. If the battery cannot be charged anymore, the battery must be changed. For that purpose the device has to be sent to the manufacturer. Warranty We provide a 24 month warranty in case of proper application according to the manual. Excluded of the guarantee are: The battery resp. the accumulator, damage by electric shock, wrong grounding and mechanical damage of the device. The guarantee expires if the device was opened.

8 Manual EFM 120 Scope of Delivery The basic equipment of the electrostatic field meter includes the following components: Carrying case Electro static field meter Charger Phone jack for the recorder output Grounding spiral cable Manual Declaration of factory calibration Optional available: Voltage gauge head MK11-S1 with banana jack Voltage gauge head MK11-S2 with BNC connector Warning Notices The electrostatic field meter must not be opened. By opening the guarantee expires. The electrostatic field meter must not be used in explosive areas. No admission for explosive areas! If high charges are possible the electrostatic field meter must be grounded. An adequate distance must be kept. Flashovers on the modulator system must be avoided! The use of the device in power plants or comparable areas is prohibited! The device can not measure alternating fields > 1Hz! Calibration A check of the measurement values is recommended annually. 2011 - Kleinwächter GmbH