DSL#08-1814.EC 2009 Ethicon Endo-Surgery. All rights reserved. 2009 PRODUCT CATALOG
Why Harmonic? Harmonic ACE Harmonic technology is the leader in advanced energy with over 6.5 million procedures performed worldwide in general surgery, gynecology, urology, vessel harvesting, and other specialties. Harmonic FOCUS Minimized Risk Eliminates potential hazards of monopolar surgery as outlined in the AORN guidelines Precise cutting with minimal thermal damage allows for safer dissection near vital structures No electricity passes to or through the patient. This is an important benefit for patients with cochlear implants, defibrillators, pacemakers, body piercings or those requiring a tracheotomy. Harmonic WAVE Maximized Efficiency Harmonic Devices are truly versatile cut, coagulate, grasp and dissect without instrument exchange May reduce operative time* Harmonic SYNERGY Reliability Every single Ethicon Endo-Surgery device is thoroughly inspected, measured, and tested to ensure quality Confidently seal and cut vessels up to 5mm with ACE, WAVE and FOCUS. (Other shears up to 3mm, blades up to 2mm; see IFU for specifications.) Reliably seals blood vessels and lymphatics (see IFU for specifications) * As shown in thyroidectomy with FOCUS vs. clamp, cut and tie (06-1289); and in Lap Cholecystectomy with LCSC5 shears vs. monopolar electrosurgery (06-0355).
Consolidate! Ethicon Endo-Surgery can provide a solution for all the energy needs in your hospital. Partner with your Ethicon Endo-Surgery sales representative to: Consolidate energy technologies across many surgeon specialties Obtain clinical benefit comparisons for any competitive technology Schedule a product demonstration Demonstrate a side-by-side competitive comparison Harmonic and EnSeal devices are used in a wide range of procedures. Contact your local sales representative for more information.
Laparoscopic shears CODE DESCRIPTION GRIP BLADE shaft DIAMETER shaft LENGTH COMPATIBLE WITH QTY ACE36E Harmonic ACE Ergonomic Curved 5mm 36cm HP054 6 ACE36P Harmonic ACE ( To be discontinued mid-year 2009, recommended replacement is ACE36E) Pistol Curved 5mm 36cm HP054 6 LCSC5HA LCSC1HA Laparoscopic Coagulating Shears/ with Hand Controls ( To be discontinued mid-year 2009, recommended replacement is ACE36E) Laparoscopic Coagulating Shears/ with Hand Controls ( To be discontinued mid-year 2009, recommended replacement is ACE36E) Pistol Curved 5mm 36cm HP054 6 Pistol Curved 5mm 36cm HP054 1
Laparoscopic shears CODE DESCRIPTION GRIP BLADE shaft DIAMETER shaft LENGTH COMPATIBLE WITH QTY LCSC5L Laparoscopic Coagulating Long Shears Pistol Curved 5mm 45cm HP054 6 LCSC5 Laparoscopic Coagulating Shears Pistol Curved 5mm 36cm HP054 6 LCSC1 Laparoscopic Coagulating Shears ( Single sales unit to be discontinued mid-year 2009, recommended replacement is ACE36E) Pistol Curved 5mm 36cm HP054 1
OPEN shears CODE DESCRIPTION GRIP BLADE shaft DIAMETER shaft LENGTH COMPATIBLE WITH QTY ACE23E Harmonic ACE Ergonomic Curved 5mm 23cm HP054 6 ACE23P Harmonic ACE ( To be discontinued mid-year 2009, recommended replacement is ACE23E) Pistol Curved 5mm 23cm HP054 6 ACE14S Harmonic ACE Scissor Curved 5mm 14cm HP054 6 FCS9 Harmonic FOCUS Scissor Curved N/A N/A HPBLUE 6
OPEN shears CODE DESCRIPTION GRIP BLADE shaft DIAMETER shaft LENGTH COMPATIBLE WITH QTY WAVE18S Harmonic WAVE Scissor Straight 8.5mm 18cm HP054 6 CS14C Coagulating Shears Scissor Curved 5mm 14cm HP054 6 CS23C Coagulating Shears Scissor Curved 5mm 23cm HP054 6
Laparoscopic Blades CODE DESCRIPTION shaft DIAMETER Shaft LENGTH COMPATIBLE with qty HBC05 Laparoscopic Ball Coagulator 5mm 31cm HP054, HSA08 6 HC325 Laparoscopic Curved Blade 5mm 32cm HP054, HSA08 6 HDH05 Laparoscopic Dissecting Hook 5mm 32cm HP054, HSA08 6
OPEN BLADES CODE DESCRIPTION Compatible with QTy HK105 Combination Hook Blade HP054, HSA08 6 SNGCB Harmonic SYNERGY Curved Blade HPBLUE 6 SNGHK Harmonic SYNERGY Hook Blade HPBLUE 6
Customer Support Center Supporting Your Goal of Quality Patient Care Whether you need usage instructions, clinical guidelines, service and repair, or emergency assistance, you ll receive peer-to-peer, 360 support from our team of specially-trained and experienced medical professionals: RNs with expertise in OR, outpatient surgery, critical care, ICU/CCU, pediatrics, pediatric ICU and med/surg Biomedical engineering technologists X-ray and mammography technologists Cardiac electrophysiology professional education specialists Complaint management specialists When You Call Our goal is to answer your call within 30 seconds If you have an emergency, press 4 to receive immediate attention 24/7 If you call after hours, emergencies will be routed immediately to a nurse or biomedical tech. Non-emergency calls will be returned the next business day (business hours are 7:30 am 6:30 pm EST). E-mail inquiries are usually answered within twenty-four hours of receipt How to Reach Us Ethicon Endo-Surgery Phone 800-873-3636 (800-USE-ENDO) Fax 513-337-7912 E-mail CSC Business Hours On-call Clinical Support Quick Dial Phone Selections customersupport@eesus.jnj.com 7:30 am 6:30 pm EST Available 24/7 Web Site ethiconendo.com 1 For pricing, availability, or to place a product order 2 For faxed latex and other product documentation 3 For technical assistance or troubleshooting for your capital equipment 4 For emergency assistance with product usage and troubleshooting 5 For product complaints 6 To speak with a registered nurse * Company directory # Main menu
CAPITAL CODE DESCRIPTION qty GEN04 Generator 300 (110v) 1 CRT01 Generator Cart 1 FSW01 Footswitch and Cable 1
CAPITAL CODE DESCRIPTION COMPATIBLE with qty HP054 Harmonic Hand Piece ACE36E, ACE36P, LCSC5HA, LCSC1HA, LCSC5L, LCSC5, LCSC1, ACE23E, ACE23P, ACE14S, WAVE18S, CS14C, CS23C, HBC05, HC325, HDH05, HK105, HSA08 1 HPBLUE Harmonic BLUE Hand Piece FCS9, SNGCB, SNGHK 1
The products specifically impacted are as follows: Code DESCRIPTION GEN01 Harmonic Scalpel Generator, Model G-110 GEN02 GEN03 Generator Cart Foot switch and cable HP052 Harmonic Scalpel Hand Piece for Generator G-110 Discontinued in 2008: Harmonic Scalpel Generator, Model G-110 220 As of December 31, 2008, Ethicon Endo-Surgery will no longer provide technical support, repair service or replacement parts for the Generator G-110 and related ancillary products. Ethicon Endo-Surgery, Inc. [EES] has not manufactured or sold Generator G-110 since December 2001. In conformance with EES policy to support capital products for 7 full years after date of last sale, December 31, 2008 will represent the last day that EES will support the Generator G-110 and related ancillary products. Support for only the above products will be affected. EES remains committed to service and support for all other Harmonic products, including Generator 300 [GEN04] and its corresponding cart, foot switch, and hand pieces. Note: If your generator does not have the name UltraCision Harmonic Scalpel on the faceplate, it is not a Harmonic generator. Why Should You Replace Your Discontinued Harmonic Generator G-110? Generator G-110 is a high-quality, reliable product. If you are still using one, you have already received at least seven years of use from it. Your Generator G-110 may continue to function beyond December 2008. However, as with any electronic device, the older it gets the more likely it is that certain components will wear out. In addition, Generator G-110 utilizes older technology that is not compatible with Harmonic instruments introduced since 2003. Notice of this discontinuation was mailed in February 2007, January 2008, and October 2008. If you have any questions, or if you are interested in learning more about our current generation Harmonic generator, the Generator 300 [GEN04], please contact your Ethicon Endo-Surgery sales representative, or our Customer Support Center at 1-800-USE-ENDO or via email to customersupport@eesus.jnj.com.
ACCESSORIES CODE DESCRIPTION COMPATIBLE with qty HSA06 5mm Blade System Adapter 2 HSA07 Hand Switching Adapter ( To be discontinued mid-year 2009, recommended replacement is HSA08) 1 HSA08 Disposable Hand Switching Adapter HBC05, HC325, HDH05, HK105, HP054 1 HAOSSL Harmonic ACE 5mm Open Sleeve 6
ACCESSORIES CODE DESCRIPTION qty HST01 Sterilization Tray 1 HST02 Test Tip 1 TLB01 Torque Lock Blade Wrench 2 TTBLUE Harmonic BLUE Test Tip 1 WAREX One Year Harmonic Extended Warranty 1