ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Similar documents
Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Pre Conference Workshop on Advanced Digital imaging

OPTIMIZATION OF SCANNING PARAMETERS OF COMPUTED RADIOGRAPHY FOR CHARACTERIZATION OF EXPANDED POLYSTYRENE

The HOIS recommended practice for in-service computed radiography of pipes

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Computed Radiography

Examination of Pipe Welds by Image Plate Based Computed Radiography System

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Gamex CR 2.0 Program description and operating manual

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Amorphous Selenium Direct Radiography for Industrial Imaging

ISO INTERNATIONAL STANDARD

Experiences of users in Digital Radiography

Digital Radiology with Photon Counting Detectors

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

CARESTREAM INDUSTREX Digital Imaging Plates

CARESTREAM INDUSTREX Digital Imaging Plates

Performance evaluation of a photon counting detector for high energy NDT applications

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

Strategies for Film Replacement in Radiography - a comparative study -

This document is a preview generated by EVS

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Fig.2: Scanner VistaScan for image plates

Advanced Digital Radiography for Field NDT

Projection Radiography. application on stream

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Computed Radiography of Resistance Temperature Sensor for Indian PHWR

Radiographic Testing (RT) [10]

Modelling Computed Radiography Detectors with a Cascaded Linear System Model

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Ray Detection Digital Image Quality and Influential Factors

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Digital Imaging Considerations Computed Radiography

Advancements In Digital Radiography: CR, DR, and DICONDE

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

Digital Radiography for the Inspection of Small Defects

A Modified Detectability Criterion for Conventional Radiography Simulation

Use of Back Scattered Ionizing Radiation for Measurement of Thickness of the Catalytic Agent Active Material

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY

ON THE WAY TO DIGITAL RADIOGRAPHY

Digital Profile Radiography Practical uses and limitations

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Advancements in Pipeline Girth Weld Inspection

Digital Radiography Systems Techniques and Performance Evaluation for Space Applications

RADIOGRAPHIC EXPOSURE

THE CR SPECIALISTS HD-CR CR 35 NDT

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Real Time Linear Array Imaging. Brian Caccamise

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

X-rays in medical diagnostics

Seminar 8. Radiology S8 1

X-ray backscattering: Variable irradiation geometry facilitates new insights

Hardware for High Energy Applications 30 October 2009

CR Basics and FAQ. Overview. Historical Perspective

Investigation of the film Kodak MX 125 in Agfa NDT S eco processing

Digital Radiography : Flat Panel

Acquisition, Processing and Display

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE

Digital Detector Array Image Quality for Various GOS Scintillators

Curved arrays for improved horizontal sizing in small pipe welds

Photomultiplier Tube

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

Digital Profile Radiography Practical uses and limitations

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Introduction To NDT. BY: Omid HEIDARY

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

REAL TIME-RESOLVED FLASH X-RAY CINEMATOGRAPHIC INVESTIGATION OF INTERFACE DEFEAT AND NUMERICAL SIMULATION VALIDATION

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

Part 3: Image quality classes

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR) Marko Rakvin *, Damir Markučič, Boris Hižman Faculty of Mechanichal engineering and naval arhitecture, University of Zagreb, Ivana Lučića 1, Zagreb, Croatia Abstract Specific properties of imaging plates, like wide dynamic range and greater sensitivity to radiation dose compared to radiographic film, as well as possibility of computer assisted analysis of digital radiographic image make computed radiography (CR) excellent non destructive method for pipe corrosion/erosion monitoring, especially insulated pipes in processing industry. Paper presents methodology for evaluation of pipe wall thickness based on the measurement of achieved radiographic contrast between areas of wall thinning and surrounding material. This technique could be used as complementary technique to usual tangential radiographic technique. Dependence of pixel intensities of digital radiographic image and radiation intensity that reaches imaging plate at three different X-ray energy levels was established. Based on that, optimatization of exposure parameters and selection of X-ray radiation energy (tube voltage) is discussed and the technique based on measurement of radiographic contrast for evaluation of the wall pipe thinning was proposed. This technique was validated by experimental measurement of wall thickness on pipe sample with artificial wall thinning areas. Measurement error was less than 5% for given sample. 2014 The Authors. Published by Elsevier Ltd. 2014 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of DAAAM International Vienna. Selection and peer-review under responsibility of DAAAM International Vienna Keywords: computed radiography; corrosion monitoring; pipe; radiographic contrast 1. Introduction Development of appropriate X and gamma radiation sensors for digital radiography enabled it to become a viable alternative to the classic film industrial radiography in almost all aspects of industrial radiography applications * Corresponding author. Tel.: +385 1 6168364; Fax: +385 1 6168 466 E-mail address: mrakvin@fsb.hr 1877-7058 2014 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of DAAAM International Vienna doi: 10.1016/j.proeng.2014.03.112

Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 1217 [1]. Due to the simplicity of the implementation of new technology in the existing systems and the similarities in application with film radiography, currently the most common form of digital industrial radiography is - computed radiography (CR). CR system consists of ionizing radiation source (X-ray tube or radioactive isotope), computer unit, CR scanner and phosphor imaging plate (IP). Phosphor IPs used for industrial radiography contain BaBr:Eu 2+ active layer in which, after radiographic exposure, latent image is formed. Scanning preexposed IP in CR scanner with laser beam enables photo luminance effect and thus transforming latent image into visible light. Emitted visible light is collected by light guides, amplified in photomultiplier tube and transferred into digital image by A/D converter. Possibility of digital radiographic image analysis, unique properties of IPs compared to radiographic film, like wide dynamic range and greater dose radiation sensitivity, CR is particularly suitable for pipe corrosion/erosion mapping and monitoring in process industry. The most common technique for this application is tangential radiographic technique. By using CR instead of film radiography problems like side wall burn off and subjectivity of the examiner is avoided and even automated, computer based evaluation can be implemented [2]. The main drawback of this technique is that only the pipe side wall perpendicular to the direction of ionizing radiation can be evaluated. This results in the need for a great number of radiographic exposures if the wall thickness over the entire pipe diameter wants to be inspected and measured. Also, this technique of determining wall thickness is limited to pipes and other cylindrical hollow objects. The relationship between radiation dose and the amount of scanning induced photoluminescence from the exposed imaging plate image plate is proportional [3][4] with radiation intensity that reaches the IP in a wide dose range and therefore CR is suitable for evaluation of wall thickness based on the quantity of X or gamma radiation penetration through matter. This technique can be considered as complementary technique to tangential radiography allowing reduction in necessary exposures for pipe corrosion/erosion monitoring. This is an indirect technique for wall thickness determination and a calibration step in the process is needed. Commonly, reference block is positioned beside the test object during the exposure and is evaluated on the same digital radiogram as the test piece. This setting is not always practical, especially for field testing. For that reason, novel method based on radiographic contrast measurement is proposed where calibration is conducted prior and separately from the testing procedure. 1.1. Theoretical background When penetrating through matter, radiation photons interact with matter what leads to absorption. Reduction of initial mono energy radiation intensity after penetrating through matter can be expressed by Beer s absorption law [5]: where: (1) I-intensity of photons transmitted across distance t, I 0 -initial photons intensity, μ-linear attenuation coefficient, t-penetrated thickness As can be seen absorption of radiation depends on material thickness and linear attenuation coefficient. Linear attenuation coefficient for given material is strongly dependent on the photon energy. For industrial radiography applications radiation produced by X-ray tubes and radioactive isotopes (like Ir192,Co60 and Se75) has multi energy radiation spectrum, continues in case of x-rays and discrete in case of radioactive isotopes. For that reason, equation 1 for multi-energetic radiation sources can be written as: (2) Linear attenuation coefficient can also be measured for given radiation source material combination. That way it is possible to establish μ eff for exact testing scenario [6]. Equations (1),(2) are based on the assumption that there is no scattered radiation present in the beam. Because of absorption mechanisms of radiation in the energy range used for industrial radiography, scattered radiation is always present. This leads to a phenomenon that radiation intensity

1218 Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 that reaches the sensor after radiation penetrates through the test object is greater than one calculated from the equation 2. For that reason, coefficient known as build-up factor is used. Build-up factor and can be defined as the ratio of total intensity of collided and un-collided photons received by the detector to the intensity of un-collided photons reach to the detector. The absorption equation can then be written as: (3) Value of the build-up factor depends mostly on radiation energy, material type and material thickness [7][8]. imaging plate pipe radiation source corrosion Δ I Fig. 1. Setup for pipe wall thickness evaluation based on radiation absorption. Figure 1 presents test setup for wall thickness determination based on difference of radiation intensity. Due to lesser amount of material that radiation has to penetrate through the wall thinning area, radiation intensity that reaches IP will be higher. By measuring the difference in intensities, assessment of local wall thinning is enabled. Amount of wall thinning can then be calculated using the equation (4) and (5), if the radiation absorbed by the detector is linearly proportional to the intensity of the radiation penetrated and the effective absorption coefficient is determined. where: (4) I Δt - intensity at double wall thickness + Δt, I norm - intensity at double wall thickness (5) Because of some CR scanner output, IP properties, build up factor influence and geometrical setup of the inspection this estimation is not straightforward. For this reason, in order to obtain reliable measurement results, one should first characterize its own CR system.

Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 1219 Instead of determining attenuation coefficient, in this paper relations between radiation dose and pixel intensity values for used CR system were determined experimentaly and wall thickness was estimated indirectly through radiographic contrast measurment. 2. Optimization of parameters In order to optimize exposure parameters, IP response to a certain dose of X-ray radiation was established experimentally. Steel step wedge samples of known thickness were exposed at three X-ray radiation energy levels: 175 kev(14mamin), 200keV (8mAmin) and 250 kev (4mAmin). Source detector distance (SDD) was 700mm. Thickness of the sample steps are given in table 1. CR system used, as well as scanning parameters are presented in table 2. Table 1. Step wedge thickness range Step No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Thickness [mm] 1 2 3 4 5 6 7 8 9 10 16,4 17,6 18,8 21,2 24 29 Table 2. CR system used Radiation source CR scanner Imaging plate Scanning parameters Balteau 300D VMI CR 5100 M 16bit Kodak Industrex flex GP Resolution 100 μm, Laser power 15 J/m 2, PMT 5,25 V Mean values of the pixel intensities were measured at each step and the obtained results are shown by figure 2a. Figure 2b illustrates the response curve of the IP at different doses of x-ray radiation of 175 kev. It is possible to discern three distinctive regions of the curve, of which only region II of the curve can be approximated by a linear function. Part I presents saturation of the IP that occurs when it is exposed to too great dose of radiation, while the nonlinearity of the curve in the III region is caused by scattered radiation (buildup effect). For that reason, it is essential to adjust radiographic exposure in a way that expected pixel intensities of tested object on a digital radiogram are in the linear portion of the curve. This ensures that equal radiographic contrast will be achived between two different areas of penetrated thickness. For CR system used in this research this reagion is between 48000 and 30000 pixel intensity value.

1220 Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 I. II. III. a) b) Fig.2. a)results of step wedge exposures;b) dependence od pixel intensity on penatrated steel wedge thickness at tube voltage 175 kv. Radiation energy influences the shape of the curve (figure 3). When exposing the samples with higher energy radiation less scattered radiation is produced (the II. region is wider) but the gradient of the curve is lesser, resulting in decreased radiographic contrast on the digital radiographic image. For this reason, radiation energy has to be chosen in respect to wall thickness and material of tested object. 3. Technique validation Fig. 3. Influence of radiation energy on radiographic contrast. In order to validate proposed technique, steel pipe sample with artificial wall loss defects of known dimensions was radiographed. Specimen is shown with figure 4. Areas with wall thickness reduction are marked 1. to 4.. Wall thickness of the sample pipe is 8,2mm.

Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 1221 1. 2. 3. 4. a) b) Fig. 4. a) pipe sample image; b) digital radiogram of pipe sample. Dependence of pixel intensity value upon penetrated thickness was obtained by exposing steel step wedge. Thickness range of the step wedges was chosen according to the pipe specimen wall thickness. Also in respect to penetrated material thickness for double wall radiography technique of pipe specimen and in accordance with ISO 17636-2 [9] the tube voltage of 200 kv and exposure of 6mAmin at SDD of 700 mm was chosen. Table 3 presents steps dimensions and measured mean pixel intensities on each step. Graphically results are present by figure 5 with corresponding regression line fitted. Table 3. Steps dimensions and measured mean pixel intensities Step No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Thickness [mm] 11,2 12,2 13,2 14,2 15,4 16,4 17,4 18,4 19,4 20,4 Pixel intensity 44011 43330 42664 41842 40978 40434 39619 38644 37567 36593

1222 Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 44000 Pixel intensity 42000 40000 38000 36000 34000 y = -790,2x + 53053 R² = 0,992 32000 30000 10 12 14 16 18 20 22 Thickness [mm] Fig. 5. Dependence of pixel intensity upon steel thickness and corresponded regression line. From collected data dependence of pixel intensity upon steel thickness for given x-ray radiation and CR system was established as follows: I px = -790,21 t + 53053 where: (5) I px pixel intensity value for penetrated thickness, t penetrated thickness. Pipe sample was exposed using radiographic exposure of 200 kv tube voltage, 6 mamin at 700 mm SDD. Double-wall penetration single-image radiographic technique was used. Mean pixel intensity values on reagions of interest were measured as shown on figure 6. Fig. 6. Example of aquisation of data for radiographic contrast calculation. The wall thickness was calculated based on the achieved radiographic contrast. Radiographic contrast (C)

Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 1223 represents the difference in pixel intensity values of the areas of interest on radiographic image. In this case, it was calculated as difference of mean pixel intensity values at areas of reduced wall thickness and surrounding material (figure 5). C= I px red - I px norm where : (6) I px red mean pixel intensity value at reduced wall thickness area, I px norm - mean pixel intensity value at area without wall degradation. From equasions 5 i 6 total penetrated material thickness can be calculated as: where: (7) t red total penetrated thickness at area of reduced wall thickness, t norm total penetrated thickness at area without wall degradation. Results are presented in the table 4. Table 4. Results of wall thickness estimation of pipe sample Position 1. 2. 3. 4. I red I norm I red I norm I red I norm I red I norm Pixel intensity 49130 43008 46548 42817 44807 41752 41747 43661 Contrast 6122 3731 3055 1914 Calculated penetrated thickness [mm] 8,253 11,48 12,3 13,77 Measured penetrated thickness [mm] 8,2 11 12,8 14,4 Measurement error [%] 0,6 3,6 4,2 4,3 Measurement error was less than 5%. This level of accuracy is comparable to the results obtained by other authors [2] [6]. It was assumed that geometrical setup (position of test sample in relation to radiation source) influences the measurement accuracy, as well as the X-ray beam uniformity and the scanning process of the IP. The results confirm the applicability of the method for pipe wall thinning evaluation. 4. Conclusion Radiography is the only NDT technology that enables thickness wall measurements of pipes under the insulation. Computed radiography is especially suitable for this kind of measurement using tangential technique, because of great dynamic range of phosphor imaging plates, easier analysis of digital radiographic image, reduced exposure ect. Because of the attribute of imaging plates that signal output during scanning is greatly proportional to intensity of radiation reaching the IP, material thickness penetrated by X or gamma radiation can be calculated indirectly by measuring pixel intensity value on the digital radiographic image. The problem with this technique is that results of such measurements are generally less reliable in comparison to the tangential radiographic technique due to effects such as scatted radiation, incorrectly chosen exposure parameters and radiographic testing geometric settings. Also, this technique involves the use of reference block for calibration on the same digital radiogram as the tested object. For that reason, influence of radiographic exposure at 175, 200 and 250 kev X-ray energy levels on IP response was analyzed and optimized in order to prevent IP saturation or excessive amount of scattered radiation. Optimal interval of pixel intensity values between 30000 and 48000 was established. Dependence between pixel intensity and penetrated steel thickness for certain radiation energy and exposure was determined. Based on these findings, wall thickness measurement based on achieved radiographic contrast was enabled with no need of using reference block on the same digital radiogram. To validate proposed method, pipe wall thickness measurement based on

1224 Marko Rakvin et al. / Procedia Engineering 69 ( 2014 ) 1216 1224 radiographic contrast was conducted on the pipe sample containing artificial wall thinning defects. Measurement error was within 5%. Further improvement of the presented method will be conducted through determining the influence of geometric settings of the test arrangement (relative position of defect to the radiation source) on the measurement accuracy. References [1] U.Ewert, U.Zscherpel, C.Heyne, M.Jechow, Strategies for Film Replacement, VII. Hungarian NDT-Conference, Eger, Hungary, April 12-14,2011. [2] U. Zscherpel, O. Alekseychuk, C. Bellon, U. Ewert, BAM Berlin, P. Rost, M. Schmid, BASF AG Ludwigshafen: Korrosionsmapping an Rohrleitungen, DGZfP-Berichtsband 80 auf CD, Jahrestagung 2002 Weimar. [3] J.A.Rowland, The physics of computed radiography, Physics in medicine and biology, 47, R123 R166, 2002. [4] T. Wawrzinek, U. Zscherpel, C. Bellon, "Wall Thickness Determination in Digital Radiography", COFREND Congress on NDT, Nantes 1997, conference proceedings, vol. 1, pp. 79-83. [5] NDT Resource Center, Introduction to Radiographic Testing, http://www.ndt-ed.org. [6] U. Zscherpel, Y. Onel, U. Ewert, New concepts for corrosion Inspection of Pipelines by Digital Industrial Radiology (DIR), 15 th WCNDT, Roma 2000. [7] B. Rokrok, A. Movafegi, K. Edalati, A. Kermani, M. Seiedi, N.Rastkhah, Monte Carlo Simulation of Scattering Phenomenon Effects on Industrial Radiography. [8] Moore, P. O. (Editor), Nondestructive Testing Handbook, Vol. 4, Radiographic Testing, American Society for Nondestructive Testing (ASNT), 3rd Edition, 2002. [9] ISO 17636-2:2013, Non-destructive testing of welds -- Radiographic testing -- Part 2: X- and gamma-ray techniques with digital detectors.