Honeywell. User Manual. SmartVFD COMPACT. Variable Frequency Drives for Constant and Variable Torque Applications

Similar documents
safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

Document code: DPD00343A Edited:

NX Series Inverters. HVAC Pocket Programming Guide

vacon 10 ac drives quick guide

SmartVFD HVAC2 APPLICATION MANUAL

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

NX series Constant and variable torque Variable Speed Drives for induction motors

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

vacon nx all in one application manual ac drives Phone: Fax: Web: -

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

S11 Adjustable Speed Drive Engineering Specification

Drive IT Low Voltage Drives. User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

VF-nC1 Adjustable Speed Drive Engineering Specification

ACH550 HVAC Drive Submittal

vacon nxs robust drive for heavy use

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

E3 Adjustable Speed Drive Engineering Specification

Manual Overview...1 2

vacon 100 flow ac drives application manual

vacon nx ac drives all in one application manual

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

user's manual nx frequency converters beam pump application asfiff13

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AF91 Adjustable Frequency Drives Series B

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

M-Max series drives. The next generation of OEM drives

for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual

In the event of a failure, the inverter switches off and a fault code appears on the display.

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual

6.9 Jump frequency - Avoiding frequency resonance

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001

13. Before making a service call Trip information and remedies

ADJUSTABLE SPEED DRIVES FS1

CHAPTER 3 WIRING DANGER

SX (690 V) System configuration

SX (400 V) System configuration

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Phoenix DX Clean Power (18 Pulse) AC Drive

SX (400V) System configuration

vacon 100 flow ac drives application manual

Multi-purpose Control Application II

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

This operation manual is intended for users with basic knowledge of electricity and electric devices.

HV9000 AF Drives Series C Manual

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

High Frequency Sinewave Guardian TM Filter

PowerFlex 400 Submittal

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

General Specifications FECA-TE /2010. Phone: Fax: Web:

QUINT-PS/ 3AC/24DC/10

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

Installation, Programming Operation, & Maintenance Manual V

GS1 Parameter Summary Detailed Parameter Listings...4 9

Fan and Pump AC Inverter

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

The new Yaskawa Varispeed G7 Inverter

BC145 SIGNAL ISOLATOR BOARD

PowerFlex 400 AC Drive Guide Specification

This Chapter contains:

Inverter Drive /Vector Drive Motors & Controls

EN 50178, IEC

Operating Instructions

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

MINI-PS AC/24DC/1.3

ACS 100 AC Drives for Speed Control of. 1 / 6 to 3 Hp (0.18 to 2.2 kw) AC Induction Motors

Altivar 28 drive Altivar 28 enclosed drive

smd frequency inverter

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

Comp-AC. User s Manual for type ACS 100 frequency converters from 0.12 to 2.2 kw

*MG21E122* Instruction Manual VLT Automation VT Drive FC 322 MAKING MODERN LIVING POSSIBLE

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

High Frequency SineWave Guardian TM Filter

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

vacon nxp arfiff30 user manual generator application ac drives

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

KBE2 DIGITAL AC ADJUSTABLE SPEED DRIVES

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

QUINT-PS/ 3AC/24DC/40

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

Transcription:

Ho Honeywell User Manual SmartVFD COMPACT Variable Frequency Drives for Constant and Variable Torque Applications

Honeywell 1 User s Manual Index 1. SAFETY...3 1.1 Warnings...3 1.2 Safety instructions...5 1.3 Grounding and Ground fault protection...5 1.4 Before running the motor...6 2. RECEIPT OF DELIVERY...7 2.1 Type designation code...7 2.2 Storage...8 2.3 Maintenance...8 2.4 Warranty...8 3. TECHNICAL DATA...9 3.1 SmartVFD COMPACT technical data...9 3.2 Power ratings...11 3.2.1 SmartVFD COMPACT - Mains voltage 208-240 V, 1~11 3.2.2 SmartVFD COMPACT - Mains voltage 208-240 V, 3~11 3.2.3 SmartVFD COMPACT - Mains voltage 115 V, 1~...12 3.2.4 SmartVFD COMPACT - Mains voltage 380-480 V, 3~12 3.2.5 SmartVFD COMPACT - Mains voltage 600 V, 3~...13 4. INSTALLATION...14 4.1 Mechanical installation...14 4.1.1 SmartVFD COMPACT dimensions...15 4.1.2 Cooling...16 4.1.3 EMC levels...16 4.1.4 Changing the EMC protection class from C2 or C3 to C4 for IT networks...17 4.2 Cabling and connections...18 4.2.1 Power cabling...18 4.2.2 Control cabling...19 4.2.3 Cable and fuse specifications...21 4.2.4 General cabling rules...22 4.2.5 Stripping lengths of motor and mains cables...23 4.2.6 Cable installation and the UL standards...23 4.2.7 Cable and motor insulation checks...24 5. COMMISSIONING...25 5.1 Commissioning steps of SmartVFD COMPACT...25 6. SMARTVFD COMPACTFAULT TRACING...27 7. SMARTVFD COMPACT APPLICATION INTERFACE...31 7.1 Introduction...31 7.2 Control I/O...33 8. CONTROL PANEL...35

2 Honeywell 8.1 General...35 8.2 Display...35 8.3 Keypad...36 8.4 Navigation on the SmartVFD COMPACT control panel...37 8.4.1 Main menu...37 8.4.2 Reference menu...38 8.4.3 Monitoring menu...38 8.4.4 Parameter menu...40 8.4.5 Fault history menu...41 9. GENERAL PURPOSE APPLICATION PARAMETERS...42 9.1 Quick setup parameters (Virtual menu, shows when par.13.1 = 1)...43 9.2 Motor settings (Control panel: Menu PAR -> P1)...44 9.3 Start/stop setup (Control panel: Menu PAR -> P2)...46 9.4 Frequency references (Control panel: Menu PAR -> P3)...46 9.5 Ramps and brakes setup (Control panel: Menu PAR -> P4)..47 9.6 Digital inputs (Control panel: Menu PAR -> P5)...48 9.7 Analogue inputs (Control panel: Menu PAR -> P6)...49 9.8 Digital and analogue outputs(control panel: Menu PAR->P7)50 9.9 Protections (Control panel: Menu PAR -> P9)...51 9.10 Autorestart parameters (Control panel: Menu PAR -> P10).52 9.11 PI control parameters (Control panel: Menu PAR -> P12)...52 9.12 Easy usage menu (Control panel: Menu PAR -> P0)...53 9.13 System parameters...54 10. PARAMETER DESCRIPTIONS...55 10.1 Motor settings (Control panel: Menu PAR -> P1)...55 10.2 Start/Stop setup (Control panel: Menu PAR -> P2)...59 10.3 Frequency references (Control panel: Menu PAR -> P3)...62 10.4 Ramps & brakes setup (Control panel: Menu PAR -> P4)...63 10.5 Digital inputs (Control panel: Menu PAR -> P5)...67 10.6 Analoque inputs (Control panel: Menu PAR -> P6)...68 10.7 Digital and analoque outputs (Control panel: Menu PAR -> P7) 69 10.8 Motor thermal protection (parameters 9.7-9.10)...70 10.9 fault Autorestart parameters (Control panel: Menu PAR -> P10) 74 10.10 PI control parameters (Control panel: Menu PAR -> P12).75 10.11 Easy usage menu (Control panel: Menu PAR -> P9)...76 10.12 Fieldbus parameters (Control panel: Menu PAR -> S2)...78 10.12.1 Termination resistor...78 10.12.2 Modbus address area...78 10.12.3 Modbus process data...79

Honeywell Safety 3 1 1. SAFETY ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! This manual contains clearly marked cautions and warnings which are intended for your personal safety and to avoid any unintentional damage to the product or connected appliances. Please read the information included in cautions and warnings carefully: = Dangerous voltage Risk of death or severe injury! = General warning Risk of damage to the product or connected appliances 1.1 WARNINGS 1 2 3 4 5 The components of the power unit of the frequency converter are live when SmartVFD COMPACT is connected to mains potential. Coming into contact with this voltage is extremely dangerous and may cause death or severe injury. The control unit is isolated from the mains potential. The motor terminals U, V, W (T1, T2, T3) and the possible brake resistor terminals -/+ are live when SmartVFD COMPACT is connected to mains, even if the motor is not running. The control I/O-terminals are isolated from the mains potential. However, the relay output terminals may have a dangerous control voltage present even when SmartVFD COMPACT is disconnected from mains. The ground leakage current of SmartVFD COMPACT frequency converters exceeds 3.5mA AC. According to standard EN61800-5- 1, a reinforced protective ground connection must be ensured. If the frequency converter is used as a part of a machine, the machine manufacturer is responsible for providing the machine with a main switch (EN 60204-1).

1 4 Safety Honeywell 6 7 If SmartVFD COMPACT is disconnected from mains while running the motor, it remains live if the motor is energized by the process. In this case the motor functions as a generator feeding energy to the frequency converter. After disconnecting the frequency converter from the mains, wait until the fan stops and the indicators on the display go out. Wait 5 more minutes before doing any work on SmartVFD COMPACT connections.

Honeywell Safety 5 1 1.2 SAFETY INSTRUCTIONS!!!!! 1 2 3 4 5 The SmartVFD COMPACT frequency converter has been designed for fixed installations only. Do not perform any measurements when the frequency converter is connected to the mains. Do not perform any voltage withstand tests on any part of Smart- VFD COMPACT. The product safety is fully tested at factory. Prior to making resistance measurements on the motor or the motor cable, disconnect the motor cable from the frequency converter. Do not open the cover of SmartVFD COMPACT. Static voltage discharge from your fingers may damage the components. Opening the cover may also damage the device. If the cover of SmartVFD COMPACT is opened, warranty becomes void. 1.3 GROUNDING AND GROUND FAULT PROTECTION The SmartVFD COMPACT frequency converter must always be grounded with an grounding conductor connected to the grounding terminal. See figure below: The ground fault protection inside the frequency converter protects only the converter itself against ground faults. If fault current protective switches are used they must be tested with the drive with ground fault currents that are possible to arise in fault situations.

1 6 Safety Honeywell 1.4 BEFORE RUNNING THE MOTOR Checklist:!!!! Before starting the motor, check that the motor is mounted properly and ensure that the machine connected to the motor allows the motor to be started. Set the maximum motor speed (frequency) according to the motor and the machine connected to it. Before reversing the motor shaft rotation direction make sure that this can be done safely. Make sure that no power correction capacitors are connected to the motor cable. s

Honeywell Receipt of Delivery 7 2. RECEIPT OF DELIVERY After unpacking the product, check that no signs of transport damages are to be found on the product and that the delivery is complete (compare the type designation of the product to the code below). Should the drive have been damaged during the shipping, please contact primarily the cargo insurance company or the carrier. If the delivery does not correspond to your order, contact the supplier immediately. 2.1 TYPE DESIGNATION CODE HVFDCD 3 C 0000 F 0 0 EMC Filter 0 = No Filter 1 = Filter included Enclosure 0 = Open Chassis 1 = NEMA 1 Control IO F = Full IO L = Limited IO Nominal Horsepower 0007 =.75 HP 0010 = 1 HP 0100 =10 HP Nominal Voltage A = 110 V B = 208 V - 230 V C = 480 V D = 600 V Phases 1 = Single Phase 3 = Triple Phase Product Family HVFDCD = Honeywell SmartVFD COMPACT Figure 2.1: SmartVFD COMPACT type designation code 2

8 Receipt of Delivery Honeywell 2.2 STORAGE If the frequency converter is to be kept in store before use make sure that the ambient conditions are acceptable: Storing temperature -40 F (-40 C) +70 F (21 C) Relative humidity < 95%, no condensation 2.3 MAINTENANCE In normal operating conditions, SmartVFD COMPACT frequency converters are maintenance-free. 2.4 WARRANTY Only manufacturing defects are covered by the warranty. The manufacturer assumes no responsibility for damages caused during or resulting from transport, receipt of the delivery, installation, commissioning or use. The manufacturer shall in no event and under no circumstances be held responsible for damages and failures resulting from misuse, wrong installation, unacceptable ambient temperature, dust, corrosive substances or operation outside the rated specifications. Neither can the manufacturer be held responsible for consequential damages. Variable frequency drive devices (VFD) and accessories: new products for thirty-six (36) months and factory refurbished drives for twelve (12) months from date of installation when start-up and commissioning is performed by Honeywell VFD Authorized and trained personnel. All VFD warranty return products must have prior authorization (Form No. 87-0284) and be returned only to the VFD Service Center in Chattanooga, TN. 2

Honeywell Technical Data 9 3 3. TECHNICAL DATA 3.1 SMARTVFD COMPACT TECHNICAL DATA Dimensions and weight Mains connection Supply network Motor connection Control characteristics Frame H (in) W (in) D (in) Weight (lb) MI1 6.1 2.6 3.9 1.2 MI2 7.7 3.5 4.0 1.5 MI3 10.3 3.9 4.3 2.18 115V, -15%...+10% 1~ 208 240V, -15%...+10% 1~ Input voltage U in 208 240V, -15%...+10% 3~ 380-480V, -15%...+10% 3~ 600V, -15%...+10% 3~ Input frequency 45 66 Hz Line current THD > 120% Connection to mains Once per minute or less (normal case) Networks Short circuit current Output voltage Output current Starting current / torque Output frequency Frequency resolution Control method Switching frequency Frequency reference Field weakening point Acceleration time Deceleration time Braking torque SmartVFD COMPACT (400V) cannot be used with corner grounded networks Maximum short circuit current has to be < 50kA 0 - U in Table 3.1 : SmartVFD COMPACT technical data Continuous rated current I N at ambient temperature max.122 F(+50 C)(depends on the unit size), overload 1.5 x I N max. 1min/10min Current 2 x I N for 2 secs in every 20 sec period. Torque depends on motor 0 320 Hz 0,01 Hz Frequency Control U/f Open Loop Sensorless Vector Control 1,5...16 khz; Factory default 6 khz Resolution 0.01 Hz 30 320 Hz 0.1 3000 sec 0.1 3000 sec 100%*T N with brake option (only in 3~ drives sizes MI2 and MI3) 30%*T N without brake option

3 10 Technical Data Honeywell Ambient conditions EMC Standards Certificates and manufacturer s declarations of conformity Ambient operating temperature Storage temperature Relative humidity Air quality: chemical vapours mech. particles Altitude Vibration: EN60068-2-6 Shock IEC 68-2-27 Enclosure class Pollution degree Immunity Emissions 14 F(-10 C) (no frost) +104/122 F(+40/ 50 C)(depends on the unit size): rated loadability I N -40 F(-40 C)...+158 F(+70 C) 0 95% RH, non-condensing, non-corrosive, no dripping water IEC 721-3-3, unit in operation, class 3C2 IEC 721-3-3, unit in operation, class 3S2 100% load capacity (no derating) up to 1000m(3281ft). 1% derating for each 100m(328.1ft) above 1000m (3281ft); max. 2000m (6562ft) 3...150 Hz Displacement amplitude 1(peak) mm at 3...15.8 Hz Max acceleration amplitude 1 G at 15.8...150 Hz UPS Drop Test (for applicable UPS weights) Storage and shipping: max 15 G, 11 ms (in package) IP20 (Open Chassis), option: NEMA 1 PD2 Complies with EN50082-1, -2, EN61800-3 115V: Complies with EMC category C4 230V : Complies with EMC category C2; With an internal RFI filter 400V: Complies with EMC category C2; With an internal RFI filter 600V: Complies with EMC category C4 All: No EMC emission protection (Honeywell level N): Without RFI filter For EMC: EN61800-3, For safety: UL508C, EN61800-5-1 For safety: CB, CE, UL, cul, For EMC: CE, CB, c-tick (see unit nameplate for more detailed approvals) Table 3.1 : SmartVFD COMPACT technical data

Honeywell Technical Data 11 3 3.2 POWER RATINGS 3.2.1 SmartVFD COMPACT - Mains voltage 208-240 V, 1~ Product code Mains voltage 208-240 V, 50/60 Hz, 1~ series 100% contin. current I N [A] Rated loadability 150% overload current [A] Motor shaft power P [HP] 3.2.2 SmartVFD COMPACT - Mains voltage 208-240 V, 3~ Nominal input current Mechanical size and weight (lb) [A] HVFDCD1B0003xxx 1.7 2.6 0.25 4.2 MI1 1.2 HVFDCD1B0005xxx 2.4 3.6 0.5 5.7 MI1 1.2 HVFDCD1B0007xxx 2.8 4.2 0.75 6.6 MI1 1.2 HVFDCD1B0010xxx 3.7 5.6 1 8.3 MI2 1.5 HVFDCD1B0015xxx 4.8 7.2 1.5 11.2 MI2 1.5 HVFDCD1B0020xxx 7.0 10.5 2 14.1 MI2 1.5 HVFDCD1B0030xxx 9.6 14.4 3 15.8 MI3 2.18 Table 3.2 : SmartVFD COMPACT power ratings, 208-240 V, 1~ Product code Mains voltage 208-240 V, 50/60 Hz, 3~ series 100% contin. current I N [A] Rated loadability 150% overload current [A] Motor shaft power Nominal input current Mechanical size and weight (lb) P[HP] [A] HVFDCD3B0003xxx 1.7 2.6 0.33 2.7 MI1 1.2 HVFDCD3B0005xxx 2.4 3.6 0.5 3.5 MI1 1.2 HVFDCD3B0007xxx 2.8 4.2 0.75 3.8 MI1 1.2 HVFDCD3B0010xxx 3.7 5.6 1 4.3 MI2 1.5 HVFDCD3B0015xxx 4.8 7.2 1.5 6.8 MI2 1.5 HVFDCD3B0020xxx 7.0 10.5 2 8.4 MI2 1.5 HVFDCD3B0030xxx 11 16.5 3 13.4 MI3 2.18 Table 3.3 : SmartVFD COMPACT power ratings 208-240 V, 3~

3 12 Technical Data Honeywell 3.2.3 SmartVFD COMPACT - Mains voltage 115 V, 1~ Product code Mains voltage 115 V, 50/60 Hz, 1~ series 100% continuous current I N [A] Rated loadability 150% overload current [ A] Note! The output voltage of the 115 V drives is 230 V. Motor shaft power 380-480V supply P[HP] 3.2.4 SmartVFD COMPACT - Mains voltage 380-480 V, 3~ Nominal input current [A] Mechanical size and weight (lb) HVFDCD1A0003xxx 1.7 2.6 0.33 9.2 MI2 1.5 HVFDCD1A0005xxx 2.4 3.6 0.5 11.6 MI2 1.5 HVFDCD1A0007xxx 2.8 4.2 0.75 12.4 MI2 1.5 HVFDCD1A0010xxx 3.7 5.6 1 15 MI2 1.5 HVFDCD1A0015xxx 4.8 7.2 1.5 16.5 MI3 2.18 Table 3.4 : SmartVFD COMPACT power ratings 115 V, 1~ Product code Mains voltage 380-480 V, 50/60 Hz, 3~ series 100% continuous current I N [A] Rated loadability 150% overload current [A] Motor shaft power 380-480V supply P[HP] Nominal input current [A] Mechanical size and weight (lb) HVFDCD3C0005xxx 1.3 2.0 0.5 2.2 MI1 1.2 HVFDCD3C0007xxx 1.9 2.9 0.75 2.8 MI1 1.2 HVFDCD3C0010xxx 2.4 3.6 1 3.2 MI1 1.2 HVFDCD3C0015xxx 3.3 5.0 1.5 4.0 MI2 1.5 HVFDCD3C0020xxx 4.3 6.5 2 5.6 MI2 1.5 HVFDCD3C0030xxx 5.6 8.4 3 7.3 MI2 1.5 HVFDCD3C0040xxx 7.6 11.4 4 9.6 MI3 2.18 HVFDCD3C0050xxx 9.0 13.5 5 11.5 MI3 2.18 HVFDCD3C0075xxx 12.0 18.0 7.5 14.9 MI3 2.18 Table 3.5 : SmartVFD COMPACT power ratings, 380-480 V, 1~

Honeywell Technical Data 13 3 3.2.5 SmartVFD COMPACT - Mains voltage 600 V, 3~ Product code Mains voltage 600 V, 50/60 Hz, 3~ series 100% contin. current I N [A] Rated loadability 150% overload current [A] Motor shaft power Nominal input current Mechanical size and weight (lb) P[HP] [A] HVFDCD3D0010xxx 1.7 2.6 1 2 MI3 2.18 HVFDCD3D0020xxx 2.7 4.1 2 3.6 MI3 2.18 HVFDCD3D0030xxx 3.9 5.9 3 5 MI3 2.18 HVFDCD3D0055xxx 6.1 9.2 5.4 7.6 MI3 2.18 HVFDCD3D0075xxx 9 13.5 7.5 10.4 MI3 2.18 Table 3.6 : SmartVFD COMPACT power ratings 600 V, 3~ Note 1: The input currents are calculated values with 100 kva line transformer supply. Note 2: The mechanical dimensions of the units are given in Chapter 4.1.1.

14 Installation Honeywell 4. INSTALLATION 4.1 MECHANICAL INSTALLATION There are two possible ways to mount the SmartVFD COMPACT to the wall; either screw or DIN-rail mounting. The mounting dimensions are given on the back of the drive and on the following page. MI1 MI2-3 =M 4 =M 5 Figure 4.1: Screw mounting 1 2 Figure 4.2: DIN-rail mounting 4

Honeywell Installation 15 4.1.1 SmartVFD COMPACT dimensions W2 W3 D2 H1 H2 H3 Honeywell W1 D1 Figure 4.3: SmartVFD COMPACT dimensions, MI1-MI3 Type H1 H2 H3 W1 W2 W3 D1 D2 MI1 6.2 5.8 5.4 2.6 1.5 0.2 3.9 0.3 MI2 7.7 7.2 6.7 3.5 2.5 0.2 4 0.3 MI3 10.3 9.9 9.5 3.9 3.0 0.2 4.3 0.3 Table 4.1 : SmartVFD COMPACT dimensions in inches 4

16 Installation Honeywell 4.1.2 Cooling Forced air flow cooling is used in all SmartVFD COMPACT drives. Enough free space must be left above and below the frequency converter to ensure sufficient air circulation and cooling. The required dimensions for free space are given in the table below: Type Dimensions (inch) A B MI1 3.9 2.0 MI2 3.9 2.0 MI3 3.9 2.0 Table 4.2 : Dimensions required for cooling Type Cooling air required (CFM) MI1 5.89 MI2 5.89 MI3 17.7 Table 4.3 : Required cooling air 4.1.3 EMC levels SmartVFD COMPACT frequency converters are divided into five classes according to the level of electromagnetic disturbances emitted, the requirements of a power system network and the installation environment (see below). The EMC class of each product is defined in the type designation code. Category C1: Frequency converters of this class comply with the requirements of category C1 of the product standard EN 61800-3 (2004). Category C1 ensures the best EMC characteristics and it includes converters the rated voltage of which is less than 1000V and which are intended for use in the 1st environment. NOTE: The requirements of class C are fulfilled only as far as the conducted emissions are concerned. Category C2: Frequency converters of this class comply with the requirements of category C2 of the product standard EN 61800-3 (2004). Category C2 includes converters in fixed installations and the rated voltage of which is less than 1000V. The class H frequency converters can be used both in the 1st and the 2nd environment. Category C3: Frequency converters of this class comply with the requirements of category C3 of the product standard EN 61800-3 (2004). Cateory C3 includes converters the rated voltage of which is less than 1000V and which are intended for use in the second environment only. 4

Honeywell Installation 17 Category C4: The drives of this class do not provide EMC emission protection. These kinds of drives are mounted in enclosures. Category C4 for IT networks: Frequency converters of this class fulfil the product standard EN 61800-3 (2004) if intended to be used in IT systems. In IT systems, the networks are isolated from earth, or connected to earth through high impedance to achieve a low leakage current. NOTE: if converters are used with other supplies, no EMC requirements are complied with. Environments in product standard EN 61800-3 (2004) First environment: Environment that includes domestic premises. It also includes establishments directly connected without intermediate transformers to a low-voltage power supply network which supplies buildings used for domestic purposes. NOTE: houses, apartments, commercial premises or offices in a residential building are examples of first environment locations. Second environment: Environment that includes all establishments other than those directly connected to a low-voltage power supply network which supplies buildings used for domestic purposes. NOTE: industrial areas, technical areas of any building fed from a dedicated transformer are examples of second environment locations. 4.1.4 Changing the EMC protection class from C2 or C3 to C4 for IT networks The EMC protection class of SmartVFD COMPACT frequency converters can be changed from class C2 or C3 to class C4 for IT networks by removing the EMCcapacitor disconnecting screw, see figure below. Note! Do not attempt to change the EMC level back to class C2 or C3. Even if the procedure above is reversed, the frequency converter will no longer fulfil the EMC requirements of class C2/C3!! 4

18 Installation Honeywell 4.2 CABLING AND CONNECTIONS 4.2.1 Power cabling Note! Tightening torque for power cables is 4-5 in-lbs. 3~ (230V, 400V) 1~ (230V) Motor out MAINS Strip the plastic cable coating for 360 earthing MOTOR Figure 4.4: SmartVFD COMPACT power connections, MI1 3~ (230V, 400V, 600V) External brake resistor 3~ (230, 400V) 1~ (230V) 1~ (115V) Motor out L1 L2/N L3 R+ R- U/T1 V/T2 W/T3 Strip the plastic cable coating for 360 earthing MAINS BRAKE RESISTOR MOTOR Figure 4.5: SmartVFD COMPACT power connections, MI2 - MI3 4

Honeywell Installation 19 4.2.2 Control cabling Attach the support AFTER installing the power cables Attach this plate BEFORE installing the power cables Figure 4.6: Mount the PE- plate and API cable support 4

20 Installation Honeywell Figure 4.7: Open the lid Control cable tightening torque: 3 in-lbs Strip the plastic cable coating for 360 earthing Figure 4.8: Install the control cables. See Chapter 7.2 4

Honeywell Installation 21 4.2.3 Cable and fuse specifications Use cables with heat resistance of at least 158 F (+70 C). The cables and the fuses must be dimensioned according to the tables below. Installation of cables according to UL regulations is presented in Chapter 4.2.6. The fuses function also as cable overload protection. These instructions apply only to cases with one motor and one cable connection from the frequency converter to the motor. In any other case, ask the factory for more information. EMC class Level H Level L Level N Mains cable types 1 1 1 Motor cable types 3 2 1 Control cable types 4 4 4 Table 4.4 : Cable types required to meet standards. EMC levels are described in Chapter 4.1.3 Cable type Description Power cable intended for fixed installation and the specific 1 mains voltage. Shielded cable not required. (NKCABLES/MCMK or similar recommended) Power cable equipped with concentric protection wire and 2 intended for the specific mains voltage. (NKCABLES /MCMK or similar recommended). Power cable equipped with compact low-impedance shield and intended for the specific mains voltage. (NKCABLES /MCCMK, SAB/ÖZCUY-J or similar recommended). 3 *360º grounding of both motor and FC connection required to meet the standard Screened cable equipped with compact low-impedance shield 4 (NKCABLES /Jamak, SAB/ÖZCuY-O or similar). Table 4.5 : Cable type descriptions Frame Type I N [A] Fuse [A] Mains cable Cu [AWG] Terminal cable size (min/max) Main terminal [AWG] Ground terminal [AWG] Control terminal [AWG] Relay terminal [AWG] MI1 P25 - P75 1,7-3,7 10 2*15+15 15-11 15-11 20-15 20-15 MI2 1P1-1P5 4,8-7,0 20 2*13+13 15-11 15-11 20-15 20-15 MI3 2P2 11 32 2*9+9 15-9 15-9 20-15 20-15 Table 4.6 : Cable and fuse sizes for SmartVFD COMPACT, 208-240V 4

22 Installation Honeywell Frame Type I N [A] Fuse [A] Mains cable Cu [AWG] Terminal cable size (min/max) Main terminal [AWG] Ground terminal [AWG] Control terminal [AWG] Relay terminal [AWG] MI1 P37-1P1 1,9-3,3 6 3*15+15 15-11 15-11 20-15 20-15 MI2 1P5-2P2 4,3-5,6 10 3*15+15 15-11 15-11 20-15 20-15 MI3 3P0-5P5 7,6-12 20 3*13+13 15-9 15-9 20-15 20-15 Table 4.7 : Cable and fuse sizes for SmartVFD COMPACT, 380-480V Note! To fulfil standard EN61800-5-1, the protective conductor should be at least AWG 7 Cu or AWG 5 Al. Another possibility is to use an additional protective conductor of at least the same size as the original one. 4.2.4 General cabling rules 1 2 Before starting the installation, check that none of the components of the frequency converter is live. Place the motor cables sufficiently far from other cables: Avoid placing the motor cables in long parallel lines with other cables If the motor cable runs in parallel with other cables, the minimum distance between the motor cable and other cables is 11.8 inches. The given distance also applies between the motor cables and signal cables of other systems. The maximum length of the motor cables is 100 feet. The motor cables should cross other cables at an angle of 90 degrees. 3 If cable insulation checks are needed, see Chapter 4.2.7. Connecting the cables: Strip the motor and mains cables as advised in Figure 4.9. Connect the mains, motor and control cables into their respective terminals, see Figures 4.4-4.8. Note the tightening torques of power cables and control cables given in page 18 and page 20. For information on cable installation according to UL regulations see Chapter 4.2.6. 4 Make sure that the control cable wires do not come in contact with the electronic components of the unit If an external brake resistor (option) is used, connect its cable to the appropriate terminal. Check the connection of the ground cable to the motor and the frequency converter terminals marked with Connect the separate shield of the motor cable to the ground plate of the frequency converter, motor and the supply centre 4

Honeywell Installation 23 4.2.5 Stripping lengths of motor and mains cables Ground conductor 0.3 in 0.3 in 1.4 in 0.8 in Figure 4.9: Stripping of cables Note! Strip also the plastic cover of the cables for 360 degree grounding. See Figures 4.4, 4.5 and 4.8. 4.2.6 Cable installation and the UL standards To meet the UL (Underwriters Laboratories) regulations, a UL-approved copper cable with a minimum heat-resistance of 140/167 F (+60/75 C) must be used. Use Class 1 wire only. The units are suitable for use on a circuit capable of delivering not more than 50,000 rms symmetrical amperes, 600 V maximum, when protected by T and J Class fuses. Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electric Code and any additional local codes. Branch circuit protection provided by fuses only. Motor overload protection provided at 110% of full load current. 4

24 Installation Honeywell 4.2.7 Cable and motor insulation checks These checks can be performed as follows if motor or cable insulations are suspected to be faulty. 1. Motor cable insulation checks Disconnect the motor cable from terminals U/T1, V/T2 and W/T3 of the frequency converter and from the motor. Measure the insulation resistance of the motor cable between each phase conductor as well as between each phase conductor and the protective ground conductor. The insulation resistance must be >1MOhm. 2. Mains cable insulation checks Disconnect the mains cable from terminals L1, L2/N and L3 of the frequency converter and from the mains. Measure the insulation resistance of the mains cable between each phase conductor as well as between each phase conductor and the protective ground conductor.the insulation resistance must be >1MOhm. 3. Motor insulation checks Disconnect the motor cable from the motor and open the bridging connections in the motor connection box. Measure the insulation resistance of each motor winding. The measurement voltage must equal at least the motor nominal voltage but not exceed 1000 V. The insulation resistance must be >1MOhm. 4

Honeywell Commissioning 25 5 5. COMMISSIONING Before commissioning, note the warnings and instructions listed in Chapter 1! 5.1 COMMISSIONING STEPS OF SMARTVFD COMPACT 1 Read carefully the safety instructions in Chapter 1 and follow them. 2 After the installation, make sure that: both the frequency converter and the motor are grounded. the mains and motor cables comply with the requirements given in Chapter 4.2.3. the control cables are located as far as possible from the power cables (see Chapter 4.2.4, step 2) and the shields of the shielded cables are connected to protective ground. 3 Check the quality and quantity of cooling air (Chapter 4.1.2). 4 Check that all Start/Stop switches connected to the I/O terminals are in Stop-position. 5 Connect the frequency converter to mains. Note: The following steps are valid if you have API Full or API Limited Application Interface in your SmartVFD COMPACT. 6 Set the parameters of group 1 according to the requirements of your application. At least the following parameters should be set: motor nominal voltage (par. 1.1) motor nominal frequency (par. 1.2) motor nominal speed (par. 1.3) motor nominal current (par. 1.4) You will find the values needed for the parameters on the motor rating plate.

5 26 Commissioning Honeywell Perform test run without motor. Perform either Test A or Test B: 7 8 9 10 A) Control from the I/O terminals: Turn the Start/Stop switch to ON position. Change the frequency reference (potentiometer). Check in the Monitoring Menu that the value of Output frequency changes according to the change of frequency reference. Turn the Start/Stop switch to OFF position. B) Control from the keypad: Select the keypad as the control place with par 2.5. You can also move to keypad control by pressing the navigation wheel for 5 seconds. Push the Start button on the keypad. Check in the Monitoring Menu that the value of Output frequency changes according to the change of frequency reference. Push the Stop button on the keypad. Run the no-load tests without the motor being connected to the process, if possible. If this is not possible, secure the safety of each test prior to running it. Inform your co-workers of the tests. Switch off the supply voltage and wait up until the drive has stopped. Connect the motor cable to the motor and to the motor cable terminals of the frequency converter. See to that all Start/Stop switches are in Stop positions. Switch the mains ON. Repeat test 7A or 7B. Perform an identification run (see par. 1.18), especially if the application requires a high startup torque or a high torque with low speed. Connect the motor to the process (if the no-load test was run without the motor being connected) Before running the tests, make sure that this can be done safely. Inform your co-workers of the tests. Repeat test 7A or 7B.

Honeywell Fault Tracing 27 6. SMARTVFD COMPACTFAULT TRACING Note: The fault codes listed in this chapter are visible if the Application Interface has a display, like e.g. in API FULL or API LIMITED or if a personal computer has been connected to the drive. When a fault is detected by the frequency converter control electronics, the drive is stopped and the symbol F together with the ordinal number of the fault and the fault code appear on the display in the following format, e.g: F1 02 Fault code (02 = overvoltage) Fault ordinal number (F1 = latest fault) The fault can be reset by pressing the Stop button on the control keypad or via the I/ O terminal or fieldbus. The faults with time labels are stored in the Fault history menu which can be browsed. The different fault codes, their causes and correcting actions are presented in the table below. Fault code Fault name Possible cause Correcting actions 1 Overcurrent 2 Overvoltage 3 Earth fault Frequency converter has detected too high a current (>4*I N ) in the motor cable: Sudden heavy load increase Short circuit in motor cables Unsuitable motor The DC-link voltage has exceeded the internal safety limit: Too short a deceleration time High overvoltage spikes in mains Current measurement has detected extra leakage current at start: Insulation failure in cables or motor Check loading. Check motor size. Check cables. Increase the deceleration time (P.4.3). Check motor cables and motor. Table 6.1 : Fault codes 6

28 Fault Tracing Honeywell Fault code Fault name Possible cause Correcting actions 8 System fault 9 Undervoltage 11 13 14 Output phase supervision Frequency converter undertemperature Frequency converter overtemperature 15 Motor stalled 16 Motor overtemperature 17 Motor Underload Component failure Faulty operation The DC-link voltage has exceeded the internal safety limit: Most probable cause: too low a supply voltage Frequency converter internal fault Power outages Current measurement has detected that there is no current in one motor phase Heat sink temperature is under - 10 C Heat sink is overheated. Motor stall protection has tripped Motor overheating has been detected by frequency converter motor temperature model. Motor is overloaded Motor underload protection has tripped Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. NOTE! If fault F8 occurs, find out the subcode of the fault from the Fault History menu under M (minutes)! In case of temporary supply voltage break reset the fault and restart the frequency converter. Check the supply voltage. If it is adequate, an internal failure has occurred. Contact the distributor near to you. Check motor cable and motor. Check the ambient temperature. Check that the cooling air flow is not blocked. Check the ambient temperature. Make sure that the switching frequency is not too high in relation to ambient temperature and motor load. Check that the motor is able to rotate freely Decrease the motor load If no motor overload exists, check the temperature model parameters. Check motor and load, e.g. for broken belts or dry pumps Table 6.1 : Fault codes 6

Honeywell Fault Tracing 29 Fault code Fault name Possible cause Correcting actions 22 EEPROM checksum fault 25 Microcontroller watchdog fault 27 34 Back EMF protection Internal bus communication 35 Application fault 41 50 IGBT Overtemperature Analogue input I in < 4mA (selected signal range 4 to 20 ma) 51 External fault 53 Fieldbus fault Parameter save fault Faulty operation Component failure Faulty operation Component failure Drive has detected that the magnetized motor is running in start situation A rotating PM-motor Ambient interference or defective hardware Application is not working properly Overtemperature alarm is issued when the IGBT switch temperature exceeds 110 C Current at the analogue input is < 4mA Control cable is broken or loose Signal source has failed Digital input fault. Digital input has been programmed as external fault input and this input is active. The data connection between the fieldbus Master and the fieldbus of the drive broken 57 Identification fault Identification run has failed Table 6.1 : Fault codes Contact the distributor near to you. Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. Make sure that there is no rotating PM-motor when the start command is given. Should the fault re-occur, contact the distributor near to you. Contact the distributor near to you. Check loading. Check motor size. Make identification run. Check the current loop circuitry. Check installation. If installation is correct contact the nearest Honeywell distributor. Run command was removed before completion of identification run. Motor is not connected to inverter. There is load on motor shaft. 6

30 Fault Tracing Honeywell F08 SubCode Fault 60 Watchdog reset 61 SW stack overflow 62 HW stack overflow 63 Misalignment 64 Illegal op 65 PLL lost lock / Low CPU voltage 66 EEPROM Device 67 EEPROM Queue full 68 MPI communication (dead or CRC errors) 70 CPU load 71 External oscillator 72 Fault in Power triggered by user Table 6.2: Fault subcodes from power F08 SubCode Fault 82 Watchdog reset 84 MPI CRC 86 MPI2 CRC 87 MPI2 message bfault subcodes from poweruffer overflow 97 MPI off line error 98 MPI driver error 101 MODBUS out of buffer 115 DeviceProperty data format tree too deep exceed 3 Table 6.2: Fault subcodes from control API 6

Honeywell API 31 7 7. SMARTVFD COMPACT APPLICATION INTERFACE 7.1 INTRODUCTION There are three versions of Application Interfaces (API) available for the SmartVFD COMPACT drive: API Full API Limited API RS-485 (Modbus RTU) 6 Digital inputs 3 Digital inputs 1 Digital input 2 Analogue inputs 1 Analogue input 1 Relay output 1 Analogue output 1 Relay output RS-485 Interface 1 Digital output RS-485 Interface 2 Relay outputs RS-485 Interface Tableau 7.1 : Available Application Interfaces This section provides you with a description of the I/O-signals for these versions and instructions for using the SmartVFD COMPACT general purpose application. The frequency reference can be selected from the analogue inputs, fieldbus, preset speeds or keypad. Basic properties: Digital inputs DI1 DI6 are freely programmable. The user can assign a single input to many functions Digital-, relay- and analogue outputs are freely programmable Analogue input 1 can be programmed as current or voltage input in API Limited version Special features in all API versions: Programmable Start/Stop and Reverse signal logic Reference scaling Programmable start and stop functions DC-brake at start and stop Programmable U/f curve Adjustable switching frequency Autorestart function after fault

7 32 API Honeywell Protections and supervisions (all fully programmable; off, warning, fault): Current signal input fault External fault Undervoltage fault Earth fault Motor thermal, stall and underload protection Fieldbus communication Special features in API Full and API Limited: 8 preset speeds Analogue input range selection, signal scaling and filtering PI-controller

Honeywell API 33 7 7.2 CONTROL I/O Reference Potentiometer:1~ 10K +/- 5% API FULL Terminal Signal Factory preset Description 1 +10Vre Ref. voltage out Maximum load 10 ma 2 AI1 Analog signal in 1 Freq. reference P) 0 - +10 V Ri = 200 k (min) 3 GND I/O signal ground 6 24Vout 24V output for DI's ±20 %, max. load 50 ma 7 GND I/O signal ground ma 8 DI1 Digital input 1 Start forward P) 9 DI2 Digital input 2 Start reverse P) 0 - +30 V Ri = 12 k min 10 DI3 Digital input 3 Preset speed B0 P) A A RS485 signal A FB Communication Positive B B RS485 signal B FB Communication Negative 4 AI2 Analog signal in 2 PI actual value P) 0(4) - 20 ma, Ri = 200 5 GND I/O signal ground 13 GND I/O signal ground 15 DI5 Digital input 5 Fault reset P) 0 - +30V Ri=12 k min 14 DI4 Digital input 4 Preset speed B1 P) 16 DI6 Digital input 6 Disable PI contr. P) 18 AO Output frequency P) 0(4) - 20 ma, RL = 500 20 DO Digital signal out Active = READY P) Open collector, max. load 48V/50mA RO 13 22 Relay out 1 (NO) Active = RUN P) Max. switching load: RO 14 250Vac/2A or 250Vdc/0.4A 23 (NO) RO 22 24 (NO) Relay out 2 Active = FAULT P) Max. switching load: 25 RO 21 250Vac/2A or 250Vdc/0.4A 26 RO 24 (NC) Table 7.2 : SmartVFD COMPACT General purpose application default I/O configuration and connections for API FULL version P) = Programmable function, see parameter lists and descriptions, chapters 9 and 10.

7 34 API Honeywell API LIMITED Terminal Signal Factory preset Description 1 +10Vre Ref. voltage out Maximum load 10 ma Freq. reference P) Can be changed to 2 AI1 Analog signal in 1 0(4)mA - 20mA current input with the 0 - +10 V Ri = 200 k dip switch (see 10.12.1) 3 GND I/O signal ground 6 24Vout 24V output for DI's ±20 %, max. load 50 ma 7 GND I/O signal ground 8 DI1 Digital input 1 Start forward P) 0 - +30 V Ri = 12 k min 9 DI2 Digital input 2 Start reverse P) 10 DI3 Digital input 3 Preset speed B0 P) A A RS485 signal A FB Communication Positive B B RS485 signal B FB Communication Negative 24 RO 22 (NO) 25 RO 21 Relay out 2 ACTIVE (Relay opened) = FAULT P) Max. switching load: 250Vac/2A or 250Vdc/ 0.4A Table 7.3 : SmartVFD COMPACT General purpose application default I/O configuration and connections for API LIMITED version P) = Programmable function, parameter lists and descriptions, chapters 9 and 10. API RS-485 Terminal Signal Factory preset Description 3 GND I/O signal ground 6 24Vout 24V output for DI's ±20 %, max. load 50 ma 7 GND I/O signal ground 8 DI1 Digital input 1 1 = Start forward 0 - +30 V Ri = 12 k min A A RS485 signal A FB Communication Positive B B RS485 signal B FB Communication Negative RO 22 Relay out 2 Max. switching load: 24 ACTIVE (Relay (NO) opened) = FAULT P) 250Vac/2A or 250Vdc/ 25 RO 21 0.4A Tableau 7.4 : SmartVFD COMPACT General purpose application default I/O configuration and connections for API RS-485 version P) = Programmable function, parameter lists and descriptions, chapters 9 and 10.

Honeywell Control Panel 35 8. CONTROL PANEL 8.1 GENERAL The SmartVFD COMPACT API Full and API Limited versions have similar control panels. The panel is integrated to the drive consisting of corresponding application card and an overlay on the drive cover with status display and button clarifications. The Control panel consists of an LCD display with backlight and a keypad including a navigation wheel, a green START button and a red STOP button (see Figure 8.1). 8.2 DISPLAY The display includes 14-segment and 7-segment blocks, arrowheads and clear text unit symbols. The arrowheads, when visible, indicate some information about the drive, which is printed in clear text on the overlay (numbers 1 14 in the figure below). The arrowheads are grouped in 3 groups with the following meanings and English overlay texts (see Figure 8.1): Group 1-5; Drive status 1 = Drive is ready to start (READY) 2 = Drive is running (RUN) 3 = Drive has stopped (STOP) 4 = Alarm condition is active (ALARM) 5 = Drive has stopped due to a fault (FAULT) Group 6-10; Control selections 6 = Motor is rotating forward (FWD) 7 = Motor is rotating reverse (REV) 8 = I/O terminal block is the selected control place (I/O) 9 = Keypad is the selected control place (KEYPAD) 10 = Fieldbus is the selected control place (BUS) Group 11-14; Navigation main menu 11 = Reference main menu (REF) 12 = Monitoring main menu (MON) 13 = Parameter main menu (PAR) 14 = Fault history main menu (FLT) 8

36 Control Panel Honeywell 8.3 KEYPAD Stop button NOTE! Press 5 seconds to activate Start Up Wizard Navigation wheel NOTE! Press 5 seconds to change control place to manual (keypad control) from remote (I/O or fieldbus) and back Figure 8.1: SmartVFD COMPACT Control panel The keypad section of the control panel consists of a navigation wheel and START and STOP buttons (see Figure 8.1). The navigation wheel is used for navigating on the panel display, but it also works as a reference potentiometer when KEYPAD has been selected as the control place of the drive. The wheel has two separate functions; - rotating the wheel e.g. for changing parameter value (12 steps / round) - pressing the wheel e.g. for accepting the new value. The drive stops always, regardless of the selected control place, by pressing the keypad STOP button. The drive starts by pressing the keypad START button, but only if the selected control place is KEYPAD. NOTE! You can quickly change the active control place from remote (I/O or fieldbus) to local (keypad) by pressing the navigation wheel for about 5 seconds!s 8

Honeywell Control Panel 37 8.4 NAVIGATION ON THE SMARTVFD COMPACT CONTROL PANEL This chapter provides you with information on navigating the menus on SmartVFD COMPACT and editing the values of the parameters. 8.4.1 Main menu The menu structure of SmartVFD COMPACT control software consists of a main menu and several submenus. Navigation in the main menu is shown below: READY RUN STOP ALARM FAULT READY RUN STOP ALARM FAULT REFERENCE MENU REF REF Displays the MON keypad reference MON value regardless of the selected PAR FLT PUSH PAR FLT Hz Hz control place. FWD REV I/O KEYPAD BUS FWD REV I/O KEYPAD BUS ROTATE MONITORING MENU In this menu you can browse the monitoring values. REF MON PA R FLT READY RUN STOP ALARM FAULT FWD REV I/O KEYPAD BUS PUSH REF MON PAR FLT READY RUN STOP ALARM FAULT FWD REV I/O KEYPAD BUS ROTATE PARAMETER MENU In this menu you can browse and edit the parameters. REF MON PAR FLT READY RUN STOP ALARM FAULT FWD REV I/O KEYPAD BUS REF MON PAR PUSH FLT READY RUN STOP ALARM FAULT FWD REV I/O KEYPAD BUS ROTATE FAULT MENU REF Here you will MON be able to browse PAR through the faults occurred. FLT READY RUN STOP ALARM FAULT FWD REV I/O KEYPAD BUS REF MON PAR PUSH FLT READY RUN Figure 8.2: The main menu of SmartVFD COMPACT STOP ALARM FAU LT FWD REV I/O KEYPAD BUS 8

38 Control Panel Honeywell 8.4.2 Reference menu READY RUN STOP ALARM FAULT REF MON PAR FLT Hz FWD REV I/O KEYPAD BUS Push to enter edit mode Change value Figure 8.3: Reference menu display Push to confirm Move to the reference menu with the navigation wheel (see Figure 8.2). The reference value can be changed with the navigation wheel as shown in Figure 8.3. The reference value follows the rotation continuously (= without separate new value acceptance). 8.4.3 Monitoring menu Alternates in the display READY RUN STOP ALARM FAULT REF MON PAR FLT Hz FWD REV I/O KEYPAD BUS Browse M1.1 - M1.20 Figure 8.4: Monitoring menu display 8

Honeywell Control Panel 39 Monitoring values mean actual values of measured signals as well as statuses of some control settings. They are visible in API Full and Limited display, but they cannot be edited. The monitoring values are listed in Table 8.1. Pushing the navigation wheel once in this menu takes the user to the next level, where the monitoring value, e.g. M1.11 and value are visible (see Figure 8.2). The monitoring values can be browsed by rolling the navigation wheel clockwise, as shown in Figure 8.4. Code Monitoring signal Unit ID Description M1.1 Output frequency Hz 1 Frequency to the motor M1.2 Frequency reference Hz 25 M1.3 Motor shaft speed rpm 2 Calculated motor speed M1.4 Motor current A 3 Measured motor current M1.5 Motor torque % 4 Calculated actual/nominal torque of the motor M1.6 Motor power % 5 Calculated actual/nominal power of the motor M1.7 Motor voltage V 6 Motor voltage M1.8 DC-link voltage V 7 Measured DC-link voltage M1.9 Unit temperature C 8 Heat sink temperature M1.10 Motor temperature % Calculated motor temperature M1.11 Analogue input 1 % 13 AI1 value M1.12 Analogue input 2 % 14 AI2 value ONLY IN API FULL! M1.13 Analogue output % 26 AO1 ONLY IN API FULL! M1.14 DI1, DI2, DI3 15 Digital input statuses M1.15 DI4, DI5, DI6 16 Digital input statuses ONLY IN API FULL! M1.16 RO1, (also RO2, DO in API FULL) 17 Relay/digital output statuses M1.17 PI setpoint % 20 In percent of the maximum process reference M1.18 PI feedback % 21 In percent of the maximum actual value M1.19 PI error value % 22 In percent of the maximum error value M1.20 PI Output % 23 In percent of the maximum output value Table 8.1 : SmartVFD COMPACT monitoring signals 8

40 Control Panel Honeywell 8.4.4 Parameter menu In Parameter menu only the Quick setup parameter list is shown by default. By giving the right value 0 to the parameter 13.1 it is possible to open other advanced parameter groups. The parameter lists and descriptions can be found in chapters 9 and 10. The following figure shows the parameter menu view: Alternates in the display READY RUN STOP ALARM FAULT REF MON PAR Hz FLT FWD REV I/O KEYPAD BUS Browse P1.1 -> Push to enter edit mode Figure 8.5: Parameter menu Change value Push to confirm 8

Honeywell Control Panel 41 8.4.5 Fault history menu READY RUN STOP ALARM FAULT REF MON PAR FLT FWD REV I/O KEYPAD BUS Push READY RUN STOP ALARM FAULT REF MON PAR FLT FWD REV I/O KEYPAD BUS Browse faults 1-9 READY RUN STOP ALARM FAULT REF MON PAR FLT FWD REV I/O KEYPAD BUS Push READY RUN STOP ALARM FAULT REF MON PAR FLT FWD REV I/O KEYPAD BUS Figure 8.6: Fault history menu In Fault history menu you can browse through 9 latest faults (see Figure 7.16). If a fault is active, the relevant fault number (e.g. F1 02) alternates in the display with main menu. When you browse between the faults, the fault codes of active faults are blinking. The active faults can be reset by pressing the STOP button for 1 time. If the fault cannot be reset, the blinking continues. It is possible to navigate in the menu structure also when there are active faults present, but the display returns automatically to the fault menu if buttons or navigation wheel are not pressed or navigation is not rotated. The operating date, hour and minute values at the fault instant are shown in the value menu (operating hours = displayed reading). Note! The whole fault history can be cleared by pressing STOP button for 5 sec time when the drive is stopped and Fault history menu is selected in the display.. See Chapter 6 in for fault descriptions. Browse for hours (H), minutes (M) and seconds (S) 8

9 42 Parameters Honeywell 9. GENERAL PURPOSE APPLICATION PARAMETERS On the next pages you can find the lists of parameters within the respective parameter groups. The parameter descriptions are given in Chapter 10. NOTE: Parameters can only be changed when drive is in stop mode! Explanations: Code: Location indication on the keypad; Shows the operator the present Monitoring value number or Parameter number Parameter: Name of monitoring value or parameter Min: Minimum value of parameter Max: Maximum value of parameter Unit: Unit of parameter value; given if available Default: Factory preset value ID: ID number of the parameter (used with fieldbus control) More information on this parameter available in chapter 10: Parameter descriptions click on the parameter name.

Honeywell Parameters 43 9 9.1 QUICK SETUP PARAMETERS (VIRTUAL MENU, SHOWS WHEN PAR.13.1 = 1) Code Parameter Min Max Unit Default ID Note P1.1 P1.2 P1.3 P1.4 Motor nominal voltage Motor nominal frequency Motor nominal speed Motor nominal current 180 690 V 230 400 600 110 30 320 Hz 50,00 111 300 20000 rpm 1440 112 0,2 x I Nunit 2,0 x I Nunit A I Nunit 113 P1.5 Motor cos 0,30 1,00 0,85 120 P1.7 Current limit 0,2 x I Nunit 2 x I Nunit A 1,5 x I Nunit 107 P1.15 Torque boost 0 1 0 109 P2.1 Remote control place 1 2 1 172 P2.2 Start function 0 1 0 505 P2.3 Stop function 0 1 0 506 P3.1 Min frequency 0,00 P3.2 Hz 0,00 101 P3.2 Max frequency P3.1 320 Hz 50,00 102 P3.3 I/O reference 0 4 3 117 P3.4 Preset speed 0 0,00 P3.2 Hz 5,00 124 P3.5 Preset speed 1 0,00 P3.2 Hz 10,00 105 P3.6 Preset speed 2 0,00 P3.2 Hz 15,00 106 P3.7 Preset speed 3 0,00 P3.2 Hz 20,00 126 Table 9.1: Quick setup parameters Check rating plate on the motor Check rating plate on the motor Default applies for a 4- pole motor. Check rating plate on the motor Check rating plate on the motor 0 = Not used 1 = Used 1 = I/O terminal 2 = Fieldbus 0 = Ramp 1 = Flying start 0 = Coasting 1 = Ramp 0 = Preset Speeds (0-7) 1 = Keypad Reference 2 = Fieldbus Reference 3 = AI1 (API FULL & LIMITED) 4 = AI2 (API FULL) Activated by digital inputs Activated by digital inputs Activated by digital inputs Activated by digital inputs

9 44 Parameters Honeywell Code Parameter Min Max Unit Default ID Note P4.2 P4.3 P6.1 P6.5 Acceleration time Deceleration time AI1 Signal range AI2 Signal range (API Full only) 0,1 3000 s 1,0 103 0,1 3000 s 1,0 104 0 3 0 379 2 3 3 390 9.2 MOTOR SETTINGS (CONTROL PANEL: MENU PAR -> P1) Acceleration time from 0 Hz to maximum frequency Deceleration time from maximum frequency to 0 Hz. API FULL and LIM- ITED: 0 = Voltage 0 10 V 1 = Voltage 2 10 V API LIMITED ONLY: 2 = Current 0 20 ma 3 = Current 4 20 ma NOTE: When using API LIMITED, select the voltage/current range also with the dip switch 2 = Current 0 20 ma 3 = Current 4 20 ma P10.4 Fault autoreset 0 1 0 731 0 = Not used 1 = Used P13.1 Parameter conceal Table 9.1: Quick setup parameters 0 1 1 115 0 = All parameters visible 1 = Only quick setup parameter group visible Code Parameter Min Max Unit Default ID Note P1.1 P1.2 P1.3 P1.4 Motor nominal voltage Motor nominal frequency Motor nominal speed Motor nominal current 180 690 V 230 400 600 110 30 320 Hz 50,00 111 300 20000 rpm 1440 112 0,2 x I Nunit 2,0 x I Nunit A I Nunit 113 P1.5 Motor cos 0,30 1,00 0,85 120 0,2 x P1.7 Current limit I Nunit Table 9.2: Motor settings 2 x I Nunit A 1,5 x I Nunit 107 Check rating plate on the motor Check rating plate on the motor Default applies for a 4- pole motor. Check rating plate on the motor Check rating plate on the motor