Handheld Digital Storage Oscilloscopes 2510 Series

Similar documents
Divide. MHz models) waveform record

SHO800 Series Handheld Digital Oscilloscope

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Specifications for DS1000CA Series

U1604A Handheld Oscilloscopes, 40 MHz

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Agilent Technologies 3000 Series Oscilloscopes

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

DS1102E, DS1052E, DS1102D, DS1052D

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

Specifications. Specifications and Characteristics Specifications

DS1000B Series Digital Oscilloscopes

2-channel models. 4-channel models

Chapter 5 : Specifications

Agilent Technologies 3000 Series Oscilloscopes

Agilent Technologies 3000 Series Oscilloscopes

User Manual. SHS800 Series Handheld Digital Oscilloscope V1.2 SIGLENT TECHNOLOGIES CO,.LTD

User Manual. SHS1000 Series Handheld Digital Oscilloscope V1.0

DSO 3000 Series Oscilloscope

Agilent Technologies 3000 Series Oscilloscopes

U1600 Series Handheld Digital Oscilloscopes

Agilent U1610A/U1620A Handheld Digital Oscilloscope

WaveAce 1000 and 2000 Oscilloscopes

Tablet Oscilloscope Data Sheet

DS1052E, DS1102D, DS1052D

Data Sheet. Digital Storage Oscilloscope. Features & Benefits. Applications. Ease-of-Use Feature DSO5202BMT DSO5102BMT DSO5062BMT

Wider vertical range (500 uv/div~10 V/div), lower noise floor, better for small signal capturing. Built-in dual-channel 25 MHz source (MSO/DS2000A-S)

DS 6000 Specifications

120,000wfm/s. GDS-2000E, 200MHz/100MHz 70MHz 2 1GSa/s ;4 1GSa/s 8 800x480 TFT LCD 1mV/div, GDS-2000E VPO(Visual Persistence Oscilloscope), 120,000

Tablet Oscilloscope tbook Mini TO1000 Data Sheet

Retool your expectations in the world s first VGA display handheld oscilloscope with two isolated channels

Appendix A: Specifications

U1600 Series Handheld Digital Oscilloscopes

Group CHAUVIN ARNOUX 190, rue Championnet F PARIS Tel. +33 (0) Fax +33 (0) X03583A00 - Ed.

Mixed Signal Oscilloscopes 2540C Series

Product Channels Bandwidth Sampling Rate Memory Resolution

Portable Multi-Channel Recorder Model DAS240-BAT

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Digital Storage and Mixed Signal Oscilloscopes 2560 Series

GDS MHz Handheld Digital Oscilloscope New Product Announcement

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Keysight U1600 Series Handheld Digital Oscilloscopes

Digital Storage Oscilloscope

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator

HP-3310B 20M Colored Handheld Oscilloscope

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

Super Phosphor Oscilloscope Introducing the GPS-1000XS series

Product Catalogue

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Realizing Professional Functionalities with an Entry-Level Pricing

True RMS Bench Multimeters 2831E and 5491B

U1600 Series Handheld Digital Oscilloscopes

Agilent U1610A/U1620A Handheld Digital Oscilloscope

5.7-inch VGA display with 3 selectable viewing modes

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

True RMS Bench Multimeter 5492B

Agilent U1610A/U1620A Handheld Digital Oscilloscope

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Analog Arts SF990 SF880 SF830 Product Specifications

Analog Arts SF900 SF650 SF610 Product Specifications

Performance Characteristics

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Product Catalogue

Economical and Multi-Functional MSO

The Meter Structure The Figure 2-1 shows the Meter structure.

DS4000 Series Digital Oscilloscope

LeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s. Main Features

GDS-2000A 300/200/100/70 MHz DSO New Product Announcement

Arbitrary/Function Waveform Generators 4075B Series

Agilent 970-Series Handheld Multimeters Data Sheet

02 Keysight DSO1000A/B Series Portable Oscilloscopes - Data Sheet

True RMS Bench Multimeter 5492B

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

99 Washington Street Melrose, MA Phone Toll Free Visit us at

02 Keysight DSO1000A/B Series Portable Oscilloscopes - Data Sheet

True RMS Bench Multimeters 2831E and 5491B

LT224/LT322/LT342/LT344/LT364 Technical Specifications

Fluke 192/196/199. ScopeMeter. Users Manual

Digital 20MHz and 60MHz Oscilloscopes

Digital Storage Oscilloscope

Digital Storage Oscilloscope

WaveStation Function/Arbitrary Waveform Generators

Technical Specifications 190 Series

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

RIGOL. Service Guide. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Jun 2013 RIGOL Technologies, Inc.

Handheld Oscilloscopes THS3000 Series Datasheet

WaveStation Function/Arbitrary Waveform Generators

Keysight Technologies U1610A/U1620A Handheld Digital Oscilloscope. Data Sheet

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data

Agilent 1000 Series Oscilloscopes. User s Guide

Product Catalogue

Transcription:

Data Sheet Handheld Digital Storage Oscilloscopes The handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one portable and lightweight package. These versatile 60 MHz and 100 MHz bandwidth scopes offer 1 GSa/s sample rates, 2 Mpts waveform memory, 32 automatic measurements, and multiple recording functions to capture transient or long-term signal behavior. The built-in 6000-count multimeter allows users to quickly switch over from an oscilloscope to a DMM to measure DC/AC voltage and current, resistance, and capacitance, including diode and continuity tests. These handheld scopes feature many useful recording functions such as trend plot, which allows data logging from the scope or multimeter. Additionally, the scope recorder function offers users 7 Mpts record length on a single channel or 3.5 Mpts on dual channel. The handheld oscilloscopes are ideal for industrial applications, power systems, electronics design, and field test and service. Features and Benefits 60 MHz (2511/2515) and 100 MHz (2512/2516) bandwidth 1 GSa/s sample rate Deep waveform memory up to 2 Mpts 2 fully isolated and floating 1,000 V CAT II, 600 V CAT III rated inputs (isolated models 2515 and 2516) 300 V CAT II rated inputs (non-isolated models 2511 and 2512) Built-in 6000-count DMM with dedicated terminals for current measurement Scope and meter trend plot functions for data logging Bright 5.7 color display Compact and lightweight 3.4 lbs (1.54 kg) FFT including four additional math functions - Add, Subtract, Multiply, and Divide 32 automatic measurements USB host port for saving and recalling waveform setups, data, and screenshots on a USB flash drive Software provided for remote PC control Advanced tools include digital filters with adjustable limits, scope and waveform recorder mode Multi-language user interface Up to four hours of continuous battery operation Model 2511 2512 2515 2516 Bandwidth 60 MHz 100 MHz 60 MHz 100 MHz Channels 2 non-isolated 2 fully isolated Typical Applications General electronics Power electronics and industrial Technical data subject to change B&K Precision Corp. 2016

Front Panel Scope input terminals Á Top View 5.7 color display Durable rubber bezel Provides grip and protection against accidental bumps. Scope and meter mode buttons Auto setup Vertical, horizontal, and trigger controls are automatically adjusted for fast signal display. Recorder function button Use the scope recorder or trend plot functions to log oscilloscope or multimeter measurements. Trigger menu button CH2 selection button CH1 selection button CH1 vertical controls Horizontal controls USB ports Multimeter input terminals Dedicated terminals provided for current measurements. CH2 vertical controls Á Side View Mini USB device port Compensate your probe or enable remote control from a PC. USB host port Connect your USB flash drive to conveniently store and recall waveform data, setups, and screenshots. DC power adapter input 2

The tools you need 2 Mpts Deep Memory Built-in Digital Multimeter Scope and Meter Trend Plot Functions See more details in your waveform with deep memory. When enabled, waveforms can be captured in high resolution while maintaining a high sample rate over a wider period of time than other comparable scopes. Speed up troubleshooting with the built-in 6000-count multimeter. Measurement functions include AC/DC voltage and current, resistance, capacitance, diode, and continuity test. Scope Trend Plot Powerful Measurement Functions Scope and Waveform Recorder Modes Display and measure the input signal s frequency spectrum. Select one of the 4 FFT windows: Rectangular, Hanning, Hamming, and Blackman. Use cursors to measure the spectral component s magnitude and frequency. Monitor and analyze long-term signal behavior by recording data continuously over a period of time. These modes allow recorded data to be played back for post acquisition analysis. Capture intermittent errors in your system. The trend plot function can be used with the oscilloscope or built-in DMM to plot measurement values over time. Up to two voltage or time parameters can be selected by the scope, and any one of the multimeter s measurement functions can be graphed. These data points can then be exported to a CSV file for further analysis. PC Connectivity Meter Trend Plot Digital Filtering Portable Operation Filter out unwanted signal components such as various types of noise with built-in digital filters. Choose from Low-Pass, High-Pass, Band-Pass, and Band-Stop filters. 3 Quickly troubleshoot in the field using battery powered operation. Built for portability, the 2510 Series handheld digital oscilloscopes are rugged, compact, and lightweight. All models come standard with travel case for safe transport on the road. PC software provided (free download from ) for seamless integration between the oscilloscope and PC. Capture and transfer waveforms, screen images, setups and measurement results to a Windows PC via the USB device port on the side of the instrument. A USB host port is also available for quick and easy screen saving.

Floating and Differential Measurements Many industrial applications such as power electronics require measurements of high voltages and currents that are not referenced to ground. This poses an issue with traditional line-powered oscilloscopes, which typically have signal common connected to the chassis of the oscilloscope. This means all measurements must be made relative to earth ground, preventing users from making differential measurements where none of the test points are referenced to ground. Safety Rated High Bandwidth Oscilloscope Probes As a workaround, some people choose to float an oscilloscope by removing the connection between the instrument's chassis and power line ground. Floating a scope is not recommended as it can put the user at a safety risk. Parasitic capacitance is also induced in the measurement which can cause ringing and invalidate the measurement. The allows engineers and technicians to make accurate and safe measurements when the signal reference is floating. Fully Isolated Channel Design for Safe Measurements (models 2515/2516 only) Models 2515 and 2516 offer two CAT III 600 V input channels for floating measurements and feature an electrically isolated circuit design between inputs and the digital acquisition circuit. Isolating the ground references eliminate ground loops and help reduce channel noise and crosstalk. Probe Model PR250SA Probe Model PR150SA All models come standard with high bandwidth, safety certified passive probes (one per channel) to help you get the most out of your scope. 2515/2516 block diagram Model Included Probes 2511 Two 150 MHz bandwidth, x1/x10 probes rated for 300 V CATII 2512 measurements 2515 Two touch-protected 250 MHz bandwidth, x10 probes rated for 1000 V CATII, 2516 600 V CATIII measurements Input Signal and Float Voltage Safety Ratings Model 2511 / 2512 2515 / 2516 Maximum signal input safety rating with included probe 300 Vrms CAT II 1000 Vrms CAT II, 600 Vrms CAT III Maximum signal input safety rating without probe 300 Vrms CAT II 300 Vrms CAT II Maximum reference floating safety rating 30 Vrms 1000 Vrms CAT II, 600 Vrms CAT III 4

Digital Storage Oscilloscope Specifications Models 2511 2512 2515 2516 Performance Characteristics Bandwidth 60 MHz 100 MHz 60 MHz 100 MHz Real Time Sampling Rate 1 GSa/s (half-channel interleaved) (1), 500 MSa/s (per channel) Channels 2 non-isolated 2 isolated Rise Time < 5.8 ns < 3.5 ns < 5.8 ns < 3.5 ns Ch-to-Ch Isolation (both channels at same V/div setting) > 100:1 at 50 MHz Memory Depth 40 kpts (half-channel interleaved) (1)(2), 20 kpts (per channel) Deep Memory (3) 2 Mpts (half-channel interleaved) (1), 1 Mpts (per channel) Vertical Resolution 8 bits Vertical Sensitivity 2 mv/div 100 V/div (1-2-5 order) 5 mv/div 100 V/div (1-2-5 order) DC Gain Accuracy 5 mv/div-100 V/div: ± 4 % Max. BNC Input Voltage CATII 300 Vrms from BNC signal to BNC shell Max. Input Voltage for Probe PR150SA (4) : 1x/10x CAT II 300 V PR250SA (5)(6) : 10x CAT III 600 V, CATII 1000 V Channel Voltage Offset Range 2 mv - 200 mv : ±1.6 V 206 mv - 10 V : ±40 V 10.2 V - 100 V : ±400 V 5 mv - 200 mv : ±1.6 V 206 mv - 10 V : ±40 V 10.2 V - 100 V : ±400 V Bandwidth Limit 20 MHz (-3 db) Horizontal Scan Range 5.0 ns/div - 50 S/div 2.5 ns/div - 50 S/div 5.0 ns/div - 50 S/div 2.5 ns/div - 50 S/div Timebase Accuracy ± 50 ppm measured over 1 ms interval Input Coupling AC, DC, GND Input Impedance 1 MΩ +/- 2 % 18 pf ± 3 pf 1 MΩ +/- 2 % 16 pf ± 3 pf Probe Attenuation Selectable Factors 1X, 5X, 10X, 50X, 100X, 500X, 1000X Vertical and Horizontal Zoom Vertically or horizontally expand or compress a live or stopped waveform I/O Interface USB USB host port support USB flash drives (FAT format) mini-usb device port for PC connectivity and probe compensation Acquisition Modes Sampling Display sample data only Peak Detect Capture the maximum and minimum values of a signal Average Waveform averaged, selectable from 4, 16, 32, 64, 128, 256 Trigger System Edge, Pulse Width, Video*, Slope, Alternative Trigger Types Trigger Modes Trigger Coupling Trigger Source Trigger Level Range Trigger Displacement Pulse Width Trigger Slope Trigger Alternate Trigger *Support signal formats: PAL/SECAM, NTSC Trigger condition: odd field, even field, all lines, or line number Auto, Normal, Single AC, DC, LF reject, HF reject CH1, CH2 ± 6 divisions from center of display Pre-trigger: Memory depth / 2* sampling Delay Trigger: 268.04 div Positive slope (>, <, =), Negative slope (>, <, =), Time: 20 ns - 10 s Positive slope (>, <, =), Negative slope (>, <, =), Time: 20 ns - 10 s CH1 trigger type: Edge, Pulse, Video, Slope CH2 trigger type: Edge, Pulse, Video, Slope 5

Digital Storage Oscilloscope Specifications (cont.) Hardware Frequency Counter Reading Resolution Range Signal Types Model 2511 2512 2515 2516 1 Hz DC couple, 10 Hz to MAX bandwidth Satisfying all trigger signals (except pulse width trigger and video trigger) Waveform Math and Measure Math Operation Add, Subtract, Multiply, Divide, FFT FFT Window mode: Hanning, Hamming, Blackman, Rectangular Sampling points: 1024 Measure Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Rise, Fall, Freq, Prd, +Wid, -Wid, +Dut, -Dut, BWid, Phas, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF Cursors Types Voltage, Time Measurements V, T, 1/ T (frequency) Display System Display 5.7 Color TFT, 320 x 234 resolution, 64K color Display Contrast (Typical) 150:1 Backlight Intensity (Typical) 300 nits Wave Display Range 8 x 12 div Wave Display Mode Dots, Vector Persistence Off, 1 sec, 2 sec, 5 sec, Infinite Menu Display 2 sec, 5 sec, 10 sec, 20 sec, Infinite Screen-Saver Off, 1 min., 2 min., 5 min., 10 min., 15 min., 30 min., 1 hr, 2 hr, 5 hr Waveform Interpolation Sin(x)/x, Linear Measure Display Modes Main, Window zoom, Scan, X-Y X-Y Sampling Frequency Support 25 ksa/s - 250 MSa/s sampling rate (1-2.5-5 order) Color Mode Normal, Invert Environmental and Safety Temperature Operating: 32 F to 104 F (0 C to +40 C) Not operating: -4 F to 158 F (-20 C to +70 C) Humidity Operating: 85% RH, 104 F (40 C), 24 hours Altitude Operating: 9,842.5 ft (3,000 m) Electromagnetic Compatibility EMC Directive 2004/108/EC, EN61326:2006 Safety Low voltage directive 2006/95/EC, EN61010-1:2001 General Storage Memory AC Adapter Power Requirements Battery Rating Battery Charge Time Battery Operating Time Dimensions (W x H x D) Weight (1) Half channel operation means that only Ch1 or Ch2 is active. (2) When sampling rate is 1 GSa/s. For sampling rate 500 MSa/s, the maximum memory depth is 20 kpts. (3) When sampling rate is < 500 MSa/s and maximum data depth mode is enabled. (4) Probe included with models 2511 and 2512 only. (5) Probe included with models 2515 and 2516 only. (6) Refer to respective probe s manual for more information on the specification. 2 reference waveforms, 20 setups, 10 waveforms Input: 100-240 VAC, 50/60 Hz Output: 9V DC, 4 A 5000 mah, 7.4 VDC Approx. 4 hrs Approx. 4 hrs 6.42 x 10.21 x 2.10 (163.2 x 259.5 x 53.3 mm) Approx. 3.4 lbs (1.54 kg) including battery Three-Year Warranty 6

Multimeter and Recorder Specifications All specifications are based on operating at temperatures 23 ± 5 C and relative humidity < 75%. Accuracy is based on ± (% of reading + offset). Multimeter Display Resolution Measurement Function Max. Input Voltage Max. Input Current (1) Input Impedance Max. Input Voltage Between Multimeter Input Reference and Ground DC Voltage 6000 counts DC voltage, AC voltage, resistance, diode, continuity, capacitance, DC current, AC current AC: 750 V (30 Hz - 1 khz) DC: 1000 V AC: 10 A (30 Hz - 1 khz) DC: 10 A 10 MΩ CAT II 600 V CAT III 300 V 60.00 mv 10 µv ± (1 % + 15 digits) 600.0 mv 100 µv 6.000 V 1 mv 60.00 V 10 mv ± (1 % + 5 digits) 600.0 V 100 mv 1000 V 1 V AC Voltage (2) 60.00 mv 10 µv ± (1 % + 15 digits) 600.0 mv 100 µv 6.000 V 1 mv 60.00 V 10 mv ± (1 % + 5 digits) 600.0 V 100 mv 750 V 1 V DC and AC Current (3)(4) Resistance 60.00 ma 10 µa 600.0 ma 100 µa ± (1.5 % + 5 digits) 6.000 A 1 ma 10.00 A 10 ma ± (2.5 % + 5 digits) 600.0 Ω 0.1 Ω 6.000 kω 1 Ω 60.00 kω 10 Ω ± (1 % + 5 digits) 600.0 kω 100 Ω 6.000 MΩ 1 kω 60.00 MΩ 10 kω ± (3 % + 5 digits) Multimeter (cont.) Capacitance 40.00 nf 10 pf ± (3 % + 10 digits) 400.0 nf 100 pf 4.000 µf 1 nf 40.00 µf 10 nf ± (4 % + 5 digits) 400.0 µf 100 nf Diode and Continuity Measure Diode Continuity Recorder 0 2 V < 50 Ω alarm (1) Current input terminals protected with internal 250 V rated fuse. (2) For frequency range 30 Hz to 1 khz. (3) For 10 A terminal, > 6 A DC or AC rms for 10 seconds ON and 15 minutes OFF. (4) For AC current ranges, frequency is verified for 30 Hz to 1 khz. Scope Trend Plot Display Mode Full view, Normal Record Length 800k points, > 24 hours Number of Channels 2 Multimeter Trend Plot Display Mode Full view, Normal Record Length 1.2M dots, > 24 hours Number of Channels 1 Scope Recorder Display Mode Full view, Normal Max. Record Length Single Channel: 7 M pts Dual Channel: 3.5 M pts Number of Channels 2 Maximum Record Size to External Storage 4 GB, 3000 hours Included Accessories User manual, passive probes (one per channel), pair of DMM test leads, 7.4 V Li-ion battery BP2510, USB cable, probe compensation connector, AC power adapter, travel case LC2510B and certificate of calibration 7 v032416